Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

Similar documents
Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]

MCF3 25CT Inrush-withstand

MCF3 DC86V11CT Inrush-withstand

CGA Series Automotive Grade Capacitors

Electromagnetic Buzzers

No. P-KAB-001 DATE PRODUCTS DATA SHEET MICRO FUSE. Type KAB. UL/cUL approved File No.E17021 RoHS COMPLIANT LEAD FREE

Refer to CATALOG NUMBERS AND RATING. Fusing within 1 min if the current is 200% of rated current. K A B N A

Technical Report No D Dated

Electromagnetic Buzzers

Technical Report No C Dated

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Refer to CATALOG NUMBERS AND RATING. Fusing within 1 min if the current is 200% of rated current. K A B N A

Technical Report No A Dated

LITHIUM MANGANESE DIOXIDE

C Series Mid Voltage Application

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Technical Report No A Dated

Contact: Customer Service Phone: Fax: esales.electrocube.com Website:

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Installation Manual Type DDR DIN rail power supply Series DDR-120, DDR-240

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Features. Figure 1. Block Diagram. Figure 2. Input - Output DC Voltage

Technical Report No B Dated

PRODUCT SAFETY DATA SHEET

PP017/PP018 Passive Probe Instruction Manual

DC-DC Converter Specification MPD6S022S

Features. Isolation PFM. Block Diagram

Technical Report No Rev. 00 Dated

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Engineering Product Specification C310T-SC Series Ceramic tube, Time delay

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Technical Report No A Dated

Lumitester PD-20 Control Kit

High-power Solid State Relays G3PH

FRENIC-Mega Series of High-performance Multi-function Inverters

Filterpack FR-BFP2-(H)0.4K to (H)15K

NIDEC COPAL ELECTRONICS CORP.

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

Approved: Date : Customer acceptance. Lithium Manganese Dioxide Battery CR2450. Typed : Date : Checked : Date : Approved : Customer admit signature:


RX 3 M.C.B A up to 63 A

RP Instruction Manual

BEFORE USING THE PRODUCT

TURQUOISE STROKE SWITCHES

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

SA Series Breaker (Surface Mount Thermal Cutoff Device)

Inductors for Power Circuits

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

COMPACT FLAT SIZE FOR AUTOMOTIVE

up to 63 A (1 module per pole)

Certificate of Compliance of RoHS

RX 3 M.C.B A up to 63 A

DX³ RCCBs - ID 4P up to 100 A

COMPACT FLAT SIZE FOR AUTOMOTIVE

MEMS Gauge Pressure Sensor

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

MATERIAL SAFETY DATA SHEET & IATA T1 T8 CERTIFICATE. Model(s): AM

New material declaration documents and other engineering documents are available upon request.

Technical Report No A Dated

EVS RP6020. Instruction Manual

(1,5 modules per pole)

SA Series Breaker (Surface Mount Thermal Cutoff Device)

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

TDK Corporation Power Systems Business Group

Thermal Cutoffs (TCO)/ Thermal-Links

PRODUCT SAFETY DATA SHEET

Specification Approval Sheet

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Surface Mount Fuses 1206 Size >Fast Acting>S1206-FA-8A~15A. General

TX³ RCCBs 2P up to 100 A

SAFETY DATA SHEET. 1. Company Identification. 2. Product Information

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

High-power Solid State Relays G3PH

User s Manual Power Supply IM E. 5th Edition

PRODUCT SAFETY DATA SHEET

Product Title Abstract

Product Information Sheet

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

TYPE EDL Electric Double Layer Supercapacitors

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

FrelTec GmbH. Multilayer Ceramic Chip Inductors SMD

Surface Mount Fuses 0603Size> Slow Blow> S0603-S Series

Lithium Ion Battery Specifications

Differential Pressure Transmitter

VSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool.

Platinum-chip Temperature Sensors in SMD Design Type According to DIN EN 60751

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

PRODUCT SAFETY DATA SHEET

Datasheet / Product specification Model: Solar AAA

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

Pressure Sensor/PS-A (ADP5)

July terminal Filters. For Large-current Power Line. YFF-HC Series [1206 inch]* Feed through filter. * Dimensions Code JIS[EIA]

Handling Precautions, Prohibitions and General Supply Notices for VARTA Microbattery GmbH CoinPower Lithium-Ion Batteries

S505SCH 5 x 20 mm Time-delay, high I 2 t, axial lead, ceramic tube fuses

Transcription:

* 1 RoHS Dimensions and construction: Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu (mm) Marking: Pb87.5-Sn10-Ag2.5* 1 100 ma less than 1 A 1 A 15 A SOC [rated current] SOC [rated current] 125V 125V * 1 High melting temperature type solders, containing 85 wt% or more lead, that are exempted from the EU RoHS Directive for hazardous substances are used. Electrical characteristics: Rated voltage Certification Rated current (I N ) Rated breaking current Temperature rise Current carrying capacity Overload operation AC 125 V * 2 100 ma 15 A 500 A PF 0.7 0.8 * 3 Until constant temperature is obtained on each part at 1.1 I N *4 * 2 Fuses with rated currents below 1 A are not covered under the Electrical Appliance and Material Safety Law. * 3 140 K or less at the center of the insulating tube and 60 K or less at the contact while the fuse is carrying 1.1 I N. * 4 Rated current 1.35 I N 2.0 I N 100 ma 3 A Over 3 A 15 A Within 60 min 5 s 2 min 12 s 2 min Typical cold resistance: Agency approval information: Rated current Cold resistance Agency/Standard Ratings covered 8 A 13 mω 10 A 11 mω 15 A 6.2 mω Note: These values are for reference only and are not intended to infer any guaranteed values. Conformity Certificate Specified in Clause 9 of the Electrical Appliance and Material Safety Law (EAMSL) of Japan has been issued by JET (Japan Electrical Safety & Environment Technology Laboratories) 1 A 15 A

Pre-arcing I-t characteristic: These I-t curve plots are of the average values of the measurements obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values. Characteristics of the fuse may vary depending on the usage conditions. Always test the fuse under the actual circuit conditions. Control No.: 060316 1000A Current 100A 10A 15 A 10 A 8 AA 10ms 100ms 1s 10s 100s Pre-arcing time Pre-arcing I 2 t-t characteristic: These I 2 t-t curve plots are of the average values of the measurements obtained under the conditions specified by our company. These data are for reference only and are not intended to infer any guaranteed values. Characteristics of the fuse may vary depending on the usage conditions. Always test the fuse under the actual circuit conditions. Control No.: 060316 10000A 2 s 15 A 10 A 8 A 1000A 2 s I 2 t 100A 2 s 10A 2 s 1ms 10ms 100ms 1s Time

Influence of ambient temperature-the re-rating of the rated current: This chart is a plot of the measurements obtained at the ambient temperatures of 40 C, 25 C, and 85 C under conditions specified by our company. The conditions of your actual application are not considered in this chart. These data are for reference purposes only and are not intended to infer any guaranteed values. Fuse characteristics may vary depending on the usage conditions. Always test the fuse under the actual circuit conditions. 140 Control No.: 170401 130 Factor of rated current (%) 120 110 100 90 80 8 A 70 10 A 15 A 60-60 -40-20 0 20 40 60 80 100 Ambient temperature ( C)

Usage conditions: * Ambient temperature: 40 C +85 C * Ambient humidity: 85% RH or less Note: Current carrying capacity of the fuse may vary depending on the ambient temperature. Storage conditions and storage period: Products packaged as delivered can be stored for one year from our shipment under the following conditions. * Ambient temperature: 30 C +40 C (no condensation) * Ambient humidity: 85% RH or less * Ambient atmosphere: Not exposed to corrosive gas or sea breeze No visible dust Not exposed to direct sunlight * Load: No application of load that may cause deformation or degradation of the product. Environmental information: This product conforms to the EU RoHS Directive 2011/65/EU. The six hazardous substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls [PBB], and polybrominated diphenyl ethers [PBDE]) specified in the EU RoHS Directive are not used intentionally in this product. However, when lead is used in applications exempted from the requirements of the Directive, this will be indicated in the Dimensions and Construction section of the corresponding product specification. Packaging: 1. 400 fuses are packed into a colorless transparent polyethylene bag. 2. An identification label is attached to each bag. 3. A bag of 400 fuses is packed into the cardboard case shown in the figure below. If the number of fuses is less than the fixed number, the fuses are still packed into the cardboard case in the same manner. 4. The following are indicated on the surface of the cardboard case: * Your part number (by request) * Quantity of fuses * Packaged date * Country of origin * Manufacturer * Production facilities * Indications required by the applicable standards (mm) Lot number: The lot number indicates the following: Example: 17012371 170123: Date manufactured 71: Process code

Ordering specifications: SOC product name: ASDLNC [rated current] Contact information: SOC is a global ISO9001 and IATF16949 registered company headquartered in Japan with subsidiaries in Asia, Europe, and North America. SOC Corporation Marketing Division: 3-16-17, Takanawa, Minato-ku, Tokyo 108-0074, Japan TEL +81-3-5420-1011 FAX +81-3-5420-6699 http://www.socfuse.com/contact/index.html SOC America Inc.: 3505 Veterans Memorial Highway, Suite K-1, Ronkonkoma, NY 11779, USA TEL +1-631-472-6666 FAX +1-631-472-6777 http://www.socamericainc.com info@socamericainc.com SOC Asia Pte. Ltd.: 15 Jalan Kilang Barat, #07-02 Frontech Centre, Singapore 159357 TEL +65-6376-4115 http://www.socfuse.com/contact/index.html socjp@pacific.net.sg SOC Europe B.V.: Databankweg 1, 3821 AL Amersfoort, the Netherlands TEL +31-33-450-4000 http://www.soceurope.nl info@soceurope.nl

Safety Precautions for Fuse Selection and Use: WARNING Read and follow these precautions before selecting and using fuses and protectors (hereafter fuses ). Failure to properly select, install, and use fuses can result in not only property damage, but also serious injury or death. Use fuses within their specification requirements. Exposing fuses to conditions that exceed or are outside specifications can lead to, for example, non-operation, nuisance operations, disconnection of the fuse-element, or explosions, and may cause injuries and/or property damage. Please note that breaking conditions for currents below the minimum breaking current and which exceed the rated breaking current are outside the range of the specification conditions. Please use this product after ensuring that the actual breaking conditions in the application are not included in this range. Fuse performance can vary greatly due to the actual conditions fuses are operated under (ambient temperature, pulse currents, heat shock, mechanical stress, etc.). Please consider all conditions a fuse will be exposed to when making a selection. Depending on the conditions, non-operation, nuisance operations, disconnection of the fuse-element, explosions, or other accidents may occur, and these may cause injuries and/or property damage. The breaking ability of a fuse will differ between AC and DC circuits. Use fuses with AC voltage ratings in AC circuits and fuses with DC voltage ratings in DC circuits. When using fuses with both AC and DC voltage ratings, attention should be given to any differences in breaking ability. A fuse s breaking ability indicates the fuse s ability in an AC or DC circuit. For example, if a fuse with an AC voltage rating is used in a DC circuit, the fuse s breaking ability will decrease, and injuries and/or property damage may occur. Check if the circuit voltage is large enough for the fuse s operation. When the circuit voltage is too small, the decrease in current caused by an increase in the fuse s resistance may prevent the fuse from operating even for abnormal currents. Do not use fuses in environments with high humidity or corrosive or flammable gases. Doing so may result in nuisance operations, disconnection of the fuse-element, or an explosion. Do not use ultrasonic waves to clean fuses. Ultrasonic cleaning may cause disconnection of the fuse-element. Do not form a fuse s leads when the fuse is at a temperature of 40 C or greater. Doing so may result in disconnection of the fuse-element because of the applied stress. Do not apply coating or potting to any fuses except sealed fuses, such as the MCFA, or their equivalents, including the MCF3. Doing so may cause disconnection of the fuse-element or a change in the fuse s characteristics. Please be aware that even sealed fuses or the equivalent are not hermetically sealed, and therefore make sure to confirm no coating or potting material has penetrated the interior or any other location of the fuse before use. As coating or potting a fuse will changes its characteristics, make sure to confirm that a coated or potted fuse still satisfies all requirements under actual usage conditions. Avoid applying excessive force when inserting a fuse into a fuse holder. Doing so may result in the fuse cracking or in contact failure, and this may significantly reduce its ability to work properly or may shorten its life. When a fuse is used in equipment that directly affects human life or that requires a high degree of reliability, more closely examine and evaluate the fuse in actual circuit conditions than is necessary for use in other general electronic equipment. Do not touch fuses when they are carrying a current. Doing so may result in electrocution or serious burns. Fuses obtained as samples should only be used for evaluation. Do not reuse fuses, but instead properly dispose of them. For final fuse selection, make sure to install the fuse in the actual application in order to confirm the selected fuse satisfies all requirements.