Appendix D: ADA Self- Assessment

Similar documents
BILLERICA OPEN SPACE AND RECREATION PLAN

ADA Checklist RESTAURANTS AND CAFETERIAS

ACCESSIBILITY SELF-EVALUATION CHECKLIST

FORM A: ACCESSIBILITY CHECKLIST. Questions. Possible Solutions A. PARKING. Location Name Location Address: (street address) (city) (state) (zip)

Location: Fraser Fort George, Prince George, Northern BC - Municipal : Trail (Great Northern Circle Route)

ACCESSIBLE COMMUNITY BUILDER CHECKLIST

The Moscone Center Facility Accessibility Information

Shelter: Primary Shelter Secondary Shelter Respite Site Only Client Service Center Pet Shelter

Surveyor Information

Chapter 8 - Special Rooms and Spaces

REAR +/- 94' 20' 10' 10'-4" 9'-6" 10'-3" 10' 20' 13'-2" Private Office 25. Private Office 23 Private Office 24 7'-1" Open Space 3 14'-7"

CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES

Chapter 6. Plumbing Elements and Facilities

Public Health Services San Joaquin Co.

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE MARKHAM CAMPUS MARKHAM, ONTARIO

th Edition Florida Accessibility Code for Building Construction

Accessibility Survey Techniques. John Salmen, AIA Andrew Yarrish, AIA Universal Designers & Consultants, Inc.

DIVISION 6: PLUMBING ELEMENTS AND FACILITIES

(2) For mounting heights suitable in schools and other facilities used primarily by children see section

Accessible Routes. Chapter 1. Accessible Routes & Clearances. General Notes

Oregon Conventi Center

Chapter 5. General Site and Building Elements

ACCESSIBILITY GUIDE REVISED

CITY OF LEMOORE AMERICAN WITH DISABILITIES ACT TRANSITION PLAN FINAL

Accessibility facts and tips for key locations in Kingston & Area

CHAPTER 4: ACCESSIBLE ROUTES

Adult Elementary Preferred Standard Approved Standard Standard for New or Relocated Blanket Range Range Fixtures, Grab Bars, etc.

ADA Design Guide Washrooms & Showers

APPENDIX B TRAINING MANUAL

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS

Amusement Rides. ADA Checklist for Existing Facilities. Amusement rides should be accessible to everyone, including people with disabilities.

Barrier Free Design Guide

Standards for Barrier-Free Campus Office for Students with Disabilities University Planning Office June 2004

Designing Pedestrian Facilities for Accessibility. Module 7 Street Furniture and On-Street Parking

ADA Entrance Accessibility

GOVERNOR S OFFICE of PLANNING AND RESEARCH

GENERAL REQUIREMENTS FOR ACCESS

MOBILITY AND ACCESSIBILITY IN OUR COMMUNITY

t e l e s c o p i c s e a t i n g p r i m e r Performance by Design

Accessibility facts and tips for key locations in Kingston & Area

Ontario Regulation. Accessibility for Ontarians with Disabilities Act, (Integrated Accessibility Standards)

BUS STOP DESIGN & PLANNING GUIDE

County of Fresno. South Annex Jail ADA Transition Plan LARS ANDERSEN & ASSOCIATES, INC. Prepared by:

Appendix "A" Transit Bus Stop Accessibility Criteria & Guidelines

Roof and Wall Specialties and Accessories

Enhanced Accessibility in the ICC/A Pacific ADA Update Conference Presented by: Kermit Robinson, CBO International Code Council

ChapterS ACCESSIBLE BUILDINGS & FACILITIES Code References 1.) Plumbing fixtures conforming to "Accessible Buildings & Facilities"

LSU University Safety Manual Section IV, Part C Stairs and Ladders. C. Stairs & Ladders

INTRODUCTION. 2 Advanced Construction Technology

02 BUILDING ACCESSIBILITY STATEMENT

Georgia-Pacific Compliance Guide for Title III of the Americans with Disabilities Act

ADA Became Law In 1990

Appendix C. Cost Estimates

SECTION B Parks System Budgeting

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 5 GROUP B AND GROUP M OCCUPANCIES

Service Bulletin No. 2905

Exam Room Group (shown) 8010 (reversed) W: 43", 46", 49" H : Wall: 30", Desk: 30" D : Wall: 14.25", Desk: 24.25" Cabinet group consists of:

HAUSMANN MOST POPULAR

Dubai Universal Design Code

Appendix G Aquilla Lake Pool Rise Recreational Resources

ACCESSIBILITY. for Public Charging Stations. Plug-In Electric Vehicle Planning Toolbox

ACCESSIBILITY REVIEW

Also below is a limited list of the proposals which will be included in the first draft of the revised ICC/ANSI A117.1 standard for accessibility.

PACIFIC FAIR ACCESS STATEMENT. Using this document. Facility Summary. Facility details

ACCESSIBILITY REVIEW

BROOKS STAIRLIFTS SUPERGLIDE 120

We're In The Game! Grandstands Press Boxes Stadium Seating Bleachers

29CFR 1910 Subpart D Walking-Working Surfaces Ladders

285 PILOT STANDARD EQUIPMENT TECHNICAL SPECIFICATIONS

Economic and Social Council

Easy as QUICK REFERENCE SLOPE GUIDE CHART

Spring Bathroom Safety

AlumiRamp WE MAKE IT POSSIBLE

The Rifton Seating System

Development of a Wheelchair with Access for Most Users and Places

East Allen County Schools Facilities History Calendar Years October 5, 2015

190/195 Tilt Shower Commode User Manual

, (New), (New)

Table Station Elements

Bruno VPL-3300B Series

ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS

Bruno VPL-3300B Series

Setting a new standard in powered wheelchairs

ZONING ORDINANCE, ARTICLE 15: OFF-STREET PARKING REQUIREMENTS PAGE

ACCESSIBILITY DETAILS FOR PARKING

Rehab Shower Commodes

IL500 Sierra Inclined Platform Lift

Electric Vehicle Charging System Guidelines for Residential Buildings

D. Motor vehicle parking, bicycle parking, and loading areas shall be separated from one another.

GENESIS OPAL PLANNING GUIDE. Unenclosed Platform Lift for commercial applications of up to 5 feet lifting height. Creating An Accessible World

Presentation Overview. Stop, Station, and Terminal Capacity

Accessible Bus Services

Stairways and Ladders

Taylors Ferry on Bankhead Lake Off the Grid Cabins

EW-52. Owner s Manual. (888) Customer Service (888) Service

RIVERSIDE 300 RIVERSIDE DR. AUSTIN, TEXAS REVISION TABLE OF CONTENTS WIFI/ FITNESS DECORATIVE LIGHTING PLAN

SEATING SOLUTIONS.COM

Creating An Accessible World. genesis. Enclosure or shaftway vertical platform lift for lifting heights up to 14 feet.

NAU DESIGN GUIDELINES FOR DISABLED ACCESS PARKING AND ACCESSIBLE ROUTE AT VEHICULAR TRAFFIC AREAS

SECTION EDITION - REVISION 2

Transcription:

Appendi D: ADA Self- Assessment 2014 Palmer Open Space and Recreation Plan Page 232

ADA Transition Plan Facility Name Jurisdiction Location Endelson Playground Recreation Department & Parks Department Main Street Total Acreage 1.60 Activity Site Amenities (equipment) Basketball, Playground Swings, Slide, Basketball Hoop Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking Could be River access, area needs to be cleared Playground old and in disrepair Locate and Install ADA accessible parking spaces Design and construct accessible path to River Replace with ADA accessible play equiptment 2015 2015 2015 Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department & Parks Department Facility Name Jurisdiction Location Bondsville Grammar Park Recreation Department & Parks Department Main Street Total Acreage 1.07 Activity Site Amenities (equipment) Play Area, Green, Monument, Path of Travel Benches, small path, small open grassy area, passive park Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking - On street parking only Locate and Install ADA accessible parking spaces 2019 Recreation Department & Parks Department Path of Travel not wheel chair accessible Widen current path to meet ADA requirements 2019 Recreation Department & Parks Department

ADA Transition Plan Facility Name Jurisdiction Location Burleigh Park/Burleigh Brook Recreation Area Recreation Department & Parks Department Old Warren Road Total Acreage 156.81 Activity Site Amenities (equipment) Sports, Hiking, Picnicking Soccer, Baseball, Basketball, Horseshoes, Trail Network Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking - On street parking only No accessible path of travel. Trails are inaccessible due to slope, grade, materials No accessible restrooms Trash cans not on path No accessible seating/benches/picnic area Locate and Install ADA accessible parking spaces Design and construct accessible path Design and construct accessible trail system Add ADA accessible facilities Relocate trash can to accessible location Add ADA accessible seating & Picnic shelters 2015 2015 2018 2017 2015 2015 Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department &Conservation Commission Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department & Parks Department Facility Name Jurisdiction Location Water Street Field Recreation Department & Parks Department Water Street Total Acreage 7.23 Activity Site Amenities (equipment) Soccer Open Field Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking - On street parking only Locate and Install ADA accessible parking spaces 2019 Recreation Department & Parks Department

ADA Transition Plan Facility Name Jurisdiction Location Eager Playground/Legion Field Recreation Department & Parks Department Rathbone Street Total Acreage 23.00 Activity Site Amenities (equipment) Sports, Picnic, Wadding Pool Playground for K-3, Playground for 5-12, Tennis Courts, Wading Pool Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking - On street parking only Locate and Install ADA accessible parking spaces 2014 Recreation Department & Parks Department No accessible path of travel. Out of date playground equipment Trash cans not accessible No accessible seating/benches/picnic area Design and construct accessible path Upgrade playground equipment, add padding under equipment Relocate trash can to accessible location Add ADA accessible seating & Picnic shelters 2015 2014 2018 2019 Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department & Parks Department Facility Name Hryniewicz Park Jurisdiction Location Recreation Department & Parks Department Main Street, Three Rivers Total Acreage 1.02 Activity Site Amenities (equipment) Picnicking, playgrounds, concerts, events Benches, playground, gazebo, ADA Parking Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority None Site is very ADA accessible

ADA Transition Plan Facility Name Jurisdiction Location Walter Bebe Chase Memorial Field Recreation Department & Parks Department Shaw Street Total Acreage 24.02 Activity Site Amenities (equipment) Sports Soccer Field, Open Space Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking No path of travel, site has 1%-2% slopes Trash cans not on path No accessible seating/benches/picnic area Locate and Install ADA two accessible parking spaces & signage Add ADA accessible path of travel Relocate trash can to accessible location Add ADA accessible seating & Picnic shelters 2019 2018 2018 2019 Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department & Parks Department Facility Name Jurisdiction Location Parks Department, Town of Palmer Church Street/River Road Veterans Monument Total Acreage 0.19 Activity Site Amenities (equipment) Site Seeing, Passive Monument, Memorials Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking - On street parking only Locate and Install ADA accessible parking spaces 2020 DPW

ADA Transition Plan Facility Name Jurisdiction Location Parks Department, Town of Palmer Park Street & Converse Street Memorial Park (WWI Monument) Total Acreage 0.28 Activity Site Amenities (equipment) Monument, Memorial Benches, Sidewalk Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No designated ADA parking Locate and Install ADA accessible parking spaces 2020 Parks Department & DPW Facility Name Three Rivers Well Field Jurisdiction Location Parks Department, Town of Palmer Oak Street Total Acreage 44.42 Activity Site Amenities (equipment) None Open field/open Space Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority Not Applicable Not Accessible to Public

ADA Transition Plan Facility Name Jurisdiction Location Lavoliette Field Recreation Department & Parks Department 2015 Main Street Total Acreage 15.81 Activity Site Amenities (equipment) Sports Baseball Fields, Soccer Fields, Restrooms Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No ADA accessible or Public Parking - On street parking only No accessible path of travel. Trails are inaccessible due to slope, grade, materials No accessible restrooms No accessible seating/benches/picnic area Locate and Install ADA accessible parking spaces. Design and construct accessible path Design and construct accessible trail system Add ADA accessible facilities Add ADA accessible seating & Picnic shelters 2015 2015 2018 2017 2015 Recreation Department & Parks Department Recreation Department & Parks Department Recreation Department &Conservation Commission Recreation Department & Parks Department Recreation Department & Parks Department Facility Name Jurisdiction Location Conservation Commission Old Warren Road Midura Family Conservation Lands Total Acreage 219.00 Activity Site Amenities (equipment) Hiking, Biking, Nature Study/Observation, Wildlife Management Trail Network Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No Designated Handicapped Parking Trails are inaccessible due to slope, grade and surfacing Accessible Trail to be provided at another location Conservation Commission Conservation Commission

ADA Transition Plan Facility Name Jurisdiction Location Total Acreage Activity Site Amenities (equipment) Conservation Commission Mountain Roads Trail System Onley Rd, Mountain Rd, St Johns Rd, McMasters Rd, Bacon Rd, Rondeau Rd, Browns Rd, Tavern Rd 128.65 (8 miles of old roads) Hiking, Biking, Nature Study/Observation, Wildlife Management Trail Network Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No Parking for Anyone Trails are inaccessible due to slope, grade and surfacing Allow authorized ATV/ORV access to Mountain Road System to people with disabilities Conservation Commission Facility Name Ware River Waterfront Jurisdiction Location Town of Palmer Main Street Total Acreage 13.01 Activity Site Amenities (equipment) Fishing, Boating, Swimming None Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority Land Locked/No Access Public Use not Applicable

ADA Transition Plan Facility Name Red Bridge Connection Jurisdiction Location Town of Palmer Springfield Street Total Acreage 8.08 Activity Site Amenities (equipment) Fishing, Boating, Swimming None Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority Land Locked/No Access Public Use not Applicable Facility Name Swift River Greenbelt Jurisdiction Location Conservation Commission River Road Total Acreage 15.01 Activity Site Amenities (equipment) Fishing, Boating, Swimming None Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No Accessible Path of Travel No Designated Parking

ADA Transition Plan Facility Name Jurisdiction Location Conservation Commission Second Street Industrial Park Green Belt Total Acreage 24.8 Activity Site Amenities (equipment) Fishing, Boating, Swimming None Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority No Accessible Path of Travel No Designated Parking Facility Name Shaw District Jurisdiction Location Conservation Commission Tavern Rd, Brown Rd, West Ware Rd, Bacon Rd Total Acreage 240.60 Activity Site Amenities (equipment) None, Public Use Not Applicable None Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority Land Locked/No Access Public Use not Applicable

ADA Transition Plan Facility Name Old B&A Railroad Bed Jurisdiction Location Conservation Commission Barker Street Total Acreage 6.50 Activity Site Amenities (equipment) Possible Trail Connectivity, but currently No Public Access None Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority Land Locked/No Access Public Use not Applicable Facility Name Jurisdiction Location Conservation Commission River Road Grand Trunk Railroad Bed Total Acreage 2.40 Activity Site Amenities (equipment) Possible Trail Connectivity, but currently No Public Access None Transition Plan Barriers to Access Corrective Actions Scheduled Changes Authority Land Locked/No Access Public Use not Applicable

Facility Inventory LOCATION: Water Street Field ACTIVITY EQUIPMENT Tables & Benches NOTES Access to Open Spaces Back and Arm Rests Adequate Number Picnic Facilities Height of Cooking Surface Grills Trash Cans Picnic Shelters Located near accessible water fountains, trash can, restroom, parking, etc Surface material Trails Dimensions Rails Signage (for visually impaired) Entrance Pools Location from accessible parking Safety features i.e. warning for visually impaired Swimming Facilities Location from accessible path into water Beaches Location from accessible parking Shade provided All Play Equipment i.e. swings, slides Same eperience provided to all Play Areas (tot lots) Enough space between equipment for wheelchair Game Areas: Berm cuts onto courts *ballfield Height *basketball Equipment Dimensions *tennis Spectator Seating Boat Docks Arm Rests Fishing Facilities Bait Shelves Equipment Fish Cleaning Tables Programming Learn-to-Swim Are special programs at your Guided Hikes facilities accessible? Interpretive Programs Services and Technical Assistance Information available in alternative formats i.e. for visually impaired Process to request interpretive services (i.e. sign language interpreter) for meetings

LOCATION: Water Street Field PARKING Total Spaces 5 Spaces Required Accessible Spaces Up to 25 1 Space 26-50 2 Spaces 51-75 3 Spaces 76-100 4 Spaces 101-150 5 Spaces 151-200 6 Spaces 201-300 7 Spaces 301-400 8 Spaces 401-500 9 Spaces Specification for Accessible Spaces Yes No Comments/ Transition Notes Accessible space located closest to accessible entrance Where spaces cannot be located within 200 ft of accessible entrance, drop-off area is provided within 100 ft Minimum width of 13 ft includes 8 ft space plus 5 ft access aisle Van Space- minimum of 1 van space for every accessible space, 8 ft wide plus 8 ft aisle. Alternative is to make all accessible spaces 11 ft wide with 5 ft aisle. Sign with international symbol of accessibility at each space or pair of spaces Sign minimum 5ft, maimum 8ft to top of sign Surface evenly paved or hard-packed (no cracks) Surface slope less than 1:20, 5% Curbcut to pathway from parking lot at each space or pair of spaces, if sidewalk (curb) is present N/A Curbcut is a minimum width of 3 ft, ecluding sloped sides, has sloped sides, all slopes not to eceed 1:12, and tetured or painted yellow N/A RAMPS NONE Slope Maimum 1:12 Minimum width 4 ft between hand rails on both sides if ramp is longer than 6 ft at 34" and 19" from ramp surface etend 12" beyond top and bottom Handgrip oval or round Handgrip smooth surface Handgrip diameter between 1 1/4" and 2" Clearance of 1 1/2" between wall and wall rail Non-slip surface Level platforms (4 ft 4 ft) at every 30 ft, at top, at bottom, at change of direction NOTES: Gravel Parking lot to Conservation Land

LOCATION: Water Street Field SITE ACCESS, PATH OF TRAVEL, ENTRANCES Site Access Accessible path of travel from passenger disembarking area and parking area to accessible entrance Disembarking area at accessible entrance Surface evenly paved or hard-packed No ponding water Path of Travel Path does not require the use of stairs Path is stable, firm, and slip resistant 3 ft wide minimum Slope maimum 1:20 (5%) and maimum cross pitch is 2% (1:50). Continuous common surface, no changes in level greater than 1/2 inch Any objects protruding onto the pathway must be detected by a person with a visual disability using a cane Objects protruding more than 4" from the wall must be within 27" of the ground, or higher than 80" Curb on the pathway must have curb cuts at drives, parking, and drop-offs Entrances Primary public entrances accessible to person using wheelchair, must be signed, gotten to independently, and not be the service entrance Level space etending 5 ft from the door, interior and eterior of entrance doors Minimum 32" clear width opening (i.e. 36" door with standard hinge) At least 18" clear floor area on latch, pull side of door Door handle no higher than 48" and operable with a closed fist Vestibule is 4 ft plus the width of the door swinging into the space Entrance(s) on a level that makes elevators accessible Door mats less than 1/2" thick are securely fastened Door mats more than 1/2" thick are recessed Grates in path of travel have openings of 1/2" maimum Signs at non-accessible entrance(s) indicate direction to accessible entrance Emergency egress- alarms with flashing lights and audible signals, sufficiently lighted NOTES: Small parking area with foot path trails

LOCATION: Water Street Field STAIRS and DOORS Stairs No open risers Nosings not projecting Treads no less than 11" wide on both sides 34"-38" above tread Handrail etends a minimum of 1 ft beyond top and bottom rise (if no safety hazard and space permits) Handgrip oval or round Handgrip has a smooth surface Handgrip diameter between 1 1/4" and 1 1/2" 1 1/2" clearance between wall and handrail Doors Minimum 32" clear opening At least 18" clear floor space on pull side of door Closing speed minimum 3 seconds to within 3" of the latch Maimum pressure 5 pounds interior doors Threshold maimum 1/2" high, beveled on both sides Hardware operable with a closed fist (no conventional door knobs or thumb latch devices) Hardware minimum 36", maimum 48" above the floor Clear, level floor space etends out 5 ft from both sides of the door Door adjacent to revolving door is accessible and unlocked Doors opening into hazardous area have hardware that is knurled or roughened NOTES: No built structures

LOCATION: Water Street Field RESTROOMS- also see Doors and Vestibules 5 ft turning space measured 12" from the floor At least one Sink: Clear floor space of 30" by 48" to allow a forward approach Mounted without pedestal or legs, height 34" to top of rim Etends at least 22" from the wall Open knee space a minimum 19" deep, 30" width, and 27" high Cover eposed pipes with insulation Faucets operable with closed fist (lever or spring activated handle) At least one Stall: Accessible to person using wheelchair at 60" wide by 72" deep Stall door is 36" wide Stall door swings out Stall door is self closing Stall door has a pull latch Lock on stall door is operable with a closed fist and 32" above the floor Coat hook is 54" high Toilet 18" from center to nearest side wall 42" minimum clear space from center to farthest wall or fiture Top of seat 17"-19" above the floor Grab Bars On back and side wall closest to toilet 1 1/4" diameter 1 1/2" clearance to wall Located 30" above and parallel to the floor Acid-etched or roughened surface 42" long Fitures Toilet paper dispenser is 24" above floor One mirror set a maimum 38" to bottom (if tilted, 42") Dispensers (towel, soap, etc) at least one of each a maimum 42" above the floor NOTES: No built structures

LOCATION: Water Street Field FLOORS, DRINKING FOUNTAINS, TELEPHONES Floors Non-slip surface Carpeting is high-density, low pile, non-absorbent, stretched taut, securely anchored Corridor width minimum is 3 ft Objects (signs, ceiling lights, fitures) can only protrude 4" into the path of travel from a height of 27" to 80" above the floor Drinking Fountains Spouts no higher than 36" from floor to outlet Hand operated push button or level controls Spouts located near front with stream of water as parallel to front as possible If recessed, recess a minimum 30" width, and no deeper than depth of fountain If no clear knee space underneath, clear floor space 30" 48" to allow parallel approach Telephones Highest operating part a maimum 54" above the floor Access within 12" of phone, 30" high by 30" wide Adjustable volume control on headset so identified SIGNS, SIGNALS, AND SWITCHES Switches, Controls, and Signs Switches and controls for light, heat, ventilation, windows, fire alarms, thermostats, etc, must be a minimum of 36" and a maimum of 48" above the floor for a forward reach, a maimum of 54" for a side reach Electrical outlets centered no lower than 18" above the floor Warning signals must be visual as well as audible Signs Mounting height must be 60" to centerline of the sign Within 18" of door jamb or recessed Letters and numbers at least 1 1/4" high Letters and numbers raised.03" Letters and numbers contrast with the background color NOTES: No built structures

LOCATION: Water Street Field SWIMMING POOLS- accessibility can be via ramp, lifting device, or transfer area Ramp at least 34" wide with a non-slip surface etending into the shallow end, slope not eceeding 1:6 with handrails on both sides Lifting device Transfer area 18" above the path of travel and a minimum of 18" wide Unobstructed path of travel not less than 48" wide around pool Non-slip surface LOCATION: Water Street Field SHOWER ROOMS- Showers must accommodate both wheel-in and transfer use Stalls 36" by 60" minimum, with a 36" door opening Floors are pitched to drain the stall at the corner farthest from the entrance Floors are non-slip surface Controls operate by a single lever with a pressure balance miing valve Controls are located on the center wall adjacent to the hinged seat Shower heads attached to a fleible metal hose Shower heads attached to wall mounting adjustable from 42" to 72" above the floor Seat is hinged and padded and at least 16" deep, folds upward, securely attached to side wall, height is 18" to the top of the seat, and at least 24" long Soap trays without handhold features unless they can support 250 pounds 2 grab bars are provided, one 30" and one 48" long, or one continuous L shaped bar Grab bars are placed horizontally at 36" above the floor line LOCATION: Water Street Field PICNICKING A minimum of 5% of the total tables must be accessible with clear space under the table top not less than 30" wide and 19" deep per seating space and not less than 27" clear from the ground to the underside of the table. An additional 29" clear space (totaling 48") must etend beyond the 19" clear space under the table to provide access For tables without toe clearance, the knee space under the table must be at least 28" high, 30" wide, and 24" deep. Top of table no higher than 32" above ground Surface of the clear ground space under and around the table must be stable, firm and slip-resistant, and evenly graded with a maimum slope of 2% in all directions Accessible tables, grills, and fire rings must have clear ground space of at least 36" around the perimeter NOTES: No built structures

Facility Inventory LOCATION: Ware River Waterfront ACTIVITY EQUIPMENT Tables & Benches NOTES Access to Open Spaces Back and Arm Rests Adequate Number Picnic Facilities Height of Cooking Surface Grills Trash Cans Picnic Shelters Located near accessible water fountains, trash can, restroom, parking, etc Surface material Trails Dimensions Rails Signage (for visually impaired) Entrance Pools Location from accessible parking Safety features i.e. warning for visually impaired Swimming Facilities Location from accessible path into water Beaches Location from accessible parking Shade provided All Play Equipment i.e. swings, slides Same eperience provided to all Play Areas (tot lots) Enough space between equipment for wheelchair Game Areas: Berm cuts onto courts *ballfield Height *basketball Equipment Dimensions *tennis Spectator Seating Boat Docks Arm Rests Fishing Facilities Bait Shelves Equipment Fish Cleaning Tables Programming Learn-to-Swim Are special programs at your Guided Hikes facilities accessible? Interpretive Programs Services and Technical Assistance Information available in alternative formats i.e. for visually impaired Process to request interpretive services (i.e. sign language interpreter) for meetings

LOCATION: Ware River Waterfront PARKING Total Spaces 5 Spaces Required Accessible Spaces Up to 25 1 Space 26-50 2 Spaces 51-75 3 Spaces 76-100 4 Spaces 101-150 5 Spaces 151-200 6 Spaces 201-300 7 Spaces 301-400 8 Spaces 401-500 9 Spaces Specification for Accessible Spaces Yes No Comments/ Transition Notes Accessible space located closest to accessible entrance Where spaces cannot be located within 200 ft of accessible entrance, drop-off area is provided within 100 ft Minimum width of 13 ft includes 8 ft space plus 5 ft access aisle Van Space- minimum of 1 van space for every accessible space, 8 ft wide plus 8 ft aisle. Alternative is to make all accessible spaces 11 ft wide with 5 ft aisle. Sign with international symbol of accessibility at each space or pair of spaces Sign minimum 5ft, maimum 8ft to top of sign Surface evenly paved or hard-packed (no cracks) Surface slope less than 1:20, 5% Curbcut to pathway from parking lot at each space or pair of spaces, if sidewalk (curb) is present N/A Curbcut is a minimum width of 3 ft, ecluding sloped sides, has sloped sides, all slopes not to eceed 1:12, and tetured or painted yellow N/A RAMPS NONE Slope Maimum 1:12 Minimum width 4 ft between hand rails on both sides if ramp is longer than 6 ft at 34" and 19" from ramp surface etend 12" beyond top and bottom Handgrip oval or round Handgrip smooth surface Handgrip diameter between 1 1/4" and 2" Clearance of 1 1/2" between wall and wall rail Non-slip surface Level platforms (4 ft 4 ft) at every 30 ft, at top, at bottom, at change of direction NOTES: Gravel Parking lot to Conservation Land

LOCATION: Ware River Waterfront SITE ACCESS, PATH OF TRAVEL, ENTRANCES Site Access Accessible path of travel from passenger disembarking area and parking area to accessible entrance Disembarking area at accessible entrance Surface evenly paved or hard-packed No ponding water Path of Travel Path does not require the use of stairs Path is stable, firm, and slip resistant 3 ft wide minimum Slope maimum 1:20 (5%) and maimum cross pitch is 2% (1:50). Continuous common surface, no changes in level greater than 1/2 inch Any objects protruding onto the pathway must be detected by a person with a visual disability using a cane Objects protruding more than 4" from the wall must be within 27" of the ground, or higher than 80" Curb on the pathway must have curb cuts at drives, parking, and drop-offs Entrances Primary public entrances accessible to person using wheelchair, must be signed, gotten to independently, and not be the service entrance Level space etending 5 ft from the door, interior and eterior of entrance doors Minimum 32" clear width opening (i.e. 36" door with standard hinge) At least 18" clear floor area on latch, pull side of door Door handle no higher than 48" and operable with a closed fist Vestibule is 4 ft plus the width of the door swinging into the space Entrance(s) on a level that makes elevators accessible Door mats less than 1/2" thick are securely fastened Door mats more than 1/2" thick are recessed Grates in path of travel have openings of 1/2" maimum Signs at non-accessible entrance(s) indicate direction to accessible entrance Emergency egress- alarms with flashing lights and audible signals, sufficiently lighted NOTES: Small parking area with foot path trails

LOCATION: Ware River Waterfront STAIRS and DOORS Stairs No open risers Nosings not projecting Treads no less than 11" wide on both sides 34"-38" above tread Handrail etends a minimum of 1 ft beyond top and bottom rise (if no safety hazard and space permits) Handgrip oval or round Handgrip has a smooth surface Handgrip diameter between 1 1/4" and 1 1/2" 1 1/2" clearance between wall and handrail Doors Minimum 32" clear opening At least 18" clear floor space on pull side of door Closing speed minimum 3 seconds to within 3" of the latch Maimum pressure 5 pounds interior doors Threshold maimum 1/2" high, beveled on both sides Hardware operable with a closed fist (no conventional door knobs or thumb latch devices) Hardware minimum 36", maimum 48" above the floor Clear, level floor space etends out 5 ft from both sides of the door Door adjacent to revolving door is accessible and unlocked Doors opening into hazardous area have hardware that is knurled or roughened NOTES: No built structures

LOCATION: Ware River Waterfront RESTROOMS- also see Doors and Vestibules 5 ft turning space measured 12" from the floor At least one Sink: Clear floor space of 30" by 48" to allow a forward approach Mounted without pedestal or legs, height 34" to top of rim Etends at least 22" from the wall Open knee space a minimum 19" deep, 30" width, and 27" high Cover eposed pipes with insulation Faucets operable with closed fist (lever or spring activated handle) At least one Stall: Accessible to person using wheelchair at 60" wide by 72" deep Stall door is 36" wide Stall door swings out Stall door is self closing Stall door has a pull latch Lock on stall door is operable with a closed fist and 32" above the floor Coat hook is 54" high Toilet 18" from center to nearest side wall 42" minimum clear space from center to farthest wall or fiture Top of seat 17"-19" above the floor Grab Bars On back and side wall closest to toilet 1 1/4" diameter 1 1/2" clearance to wall Located 30" above and parallel to the floor Acid-etched or roughened surface 42" long Fitures Toilet paper dispenser is 24" above floor One mirror set a maimum 38" to bottom (if tilted, 42") Dispensers (towel, soap, etc) at least one of each a maimum 42" above the floor NOTES: No built structures

LOCATION: Ware River Waterfront FLOORS, DRINKING FOUNTAINS, TELEPHONES Floors Non-slip surface Carpeting is high-density, low pile, non-absorbent, stretched taut, securely anchored Corridor width minimum is 3 ft Objects (signs, ceiling lights, fitures) can only protrude 4" into the path of travel from a height of 27" to 80" above the floor Drinking Fountains Spouts no higher than 36" from floor to outlet Hand operated push button or level controls Spouts located near front with stream of water as parallel to front as possible If recessed, recess a minimum 30" width, and no deeper than depth of fountain If no clear knee space underneath, clear floor space 30" 48" to allow parallel approach Telephones Highest operating part a maimum 54" above the floor Access within 12" of phone, 30" high by 30" wide Adjustable volume control on headset so identified SIGNS, SIGNALS, AND SWITCHES Switches, Controls, and Signs Switches and controls for light, heat, ventilation, windows, fire alarms, thermostats, etc, must be a minimum of 36" and a maimum of 48" above the floor for a forward reach, a maimum of 54" for a side reach Electrical outlets centered no lower than 18" above the floor Warning signals must be visual as well as audible Signs Mounting height must be 60" to centerline of the sign Within 18" of door jamb or recessed Letters and numbers at least 1 1/4" high Letters and numbers raised.03" Letters and numbers contrast with the background color NOTES: No built structures

LOCATION: Ware River Waterfront SWIMMING POOLS- accessibility can be via ramp, lifting device, or transfer area Ramp at least 34" wide with a non-slip surface etending into the shallow end, slope not eceeding 1:6 with handrails on both sides Lifting device Transfer area 18" above the path of travel and a minimum of 18" wide Unobstructed path of travel not less than 48" wide around pool Non-slip surface LOCATION: Ware River Waterfront SHOWER ROOMS- Showers must accommodate both wheel-in and transfer use Stalls 36" by 60" minimum, with a 36" door opening Floors are pitched to drain the stall at the corner farthest from the entrance Floors are non-slip surface Controls operate by a single lever with a pressure balance miing valve Controls are located on the center wall adjacent to the hinged seat Shower heads attached to a fleible metal hose Shower heads attached to wall mounting adjustable from 42" to 72" above the floor Seat is hinged and padded and at least 16" deep, folds upward, securely attached to side wall, height is 18" to the top of the seat, and at least 24" long Soap trays without handhold features unless they can support 250 pounds 2 grab bars are provided, one 30" and one 48" long, or one continuous L shaped bar Grab bars are placed horizontally at 36" above the floor line LOCATION: Ware River Waterfront PICNICKING A minimum of 5% of the total tables must be accessible with clear space under the table top not less than 30" wide and 19" deep per seating space and not less than 27" clear from the ground to the underside of the table. An additional 29" clear space (totaling 48") must etend beyond the 19" clear space under the table to provide access For tables without toe clearance, the knee space under the table must be at least 28" high, 30" wide, and 24" deep. Top of table no higher than 32" above ground Surface of the clear ground space under and around the table must be stable, firm and slip-resistant, and evenly graded with a maimum slope of 2% in all directions Accessible tables, grills, and fire rings must have clear ground space of at least 36" around the perimeter NOTES: No built structures

Facility Inventory LOCATION: Veterans Monument ACTIVITY EQUIPMENT Tables & Benches NOTES Access to Open Spaces Back and Arm Rests Adequate Number Picnic Facilities Height of Cooking Surface Grills Trash Cans Picnic Shelters Located near accessible water fountains, trash can, restroom, parking, etc Surface material Trails Dimensions Rails Signage (for visually impaired) Entrance Pools Location from accessible parking Safety features i.e. warning for visually impaired Swimming Facilities Location from accessible path into water Beaches Location from accessible parking Shade provided All Play Equipment i.e. swings, slides Same eperience provided to all Play Areas (tot lots) Enough space between equipment for wheelchair Game Areas: Berm cuts onto courts *ballfield Height *basketball Equipment Dimensions *tennis Spectator Seating Boat Docks Arm Rests Fishing Facilities Bait Shelves Equipment Fish Cleaning Tables Programming Learn-to-Swim Are special programs at your Guided Hikes facilities accessible? Interpretive Programs Services and Technical Assistance Information available in alternative formats i.e. for visually impaired Process to request interpretive services (i.e. sign language interpreter) for meetings

LOCATION: Veterans Monument PARKING Total Spaces 5 Spaces Required Accessible Spaces Up to 25 1 Space 26-50 2 Spaces 51-75 3 Spaces 76-100 4 Spaces 101-150 5 Spaces 151-200 6 Spaces 201-300 7 Spaces 301-400 8 Spaces 401-500 9 Spaces Specification for Accessible Spaces Yes No Comments/ Transition Notes Accessible space located closest to accessible entrance Where spaces cannot be located within 200 ft of accessible entrance, drop-off area is provided within 100 ft Minimum width of 13 ft includes 8 ft space plus 5 ft access aisle Van Space- minimum of 1 van space for every accessible space, 8 ft wide plus 8 ft aisle. Alternative is to make all accessible spaces 11 ft wide with 5 ft aisle. Sign with international symbol of accessibility at each space or pair of spaces Sign minimum 5ft, maimum 8ft to top of sign Surface evenly paved or hard-packed (no cracks) Surface slope less than 1:20, 5% Curbcut to pathway from parking lot at each space or pair of spaces, if sidewalk (curb) is present N/A Curbcut is a minimum width of 3 ft, ecluding sloped sides, has sloped sides, all slopes not to eceed 1:12, and tetured or painted yellow N/A RAMPS NONE Slope Maimum 1:12 Minimum width 4 ft between hand rails on both sides if ramp is longer than 6 ft at 34" and 19" from ramp surface etend 12" beyond top and bottom Handgrip oval or round Handgrip smooth surface Handgrip diameter between 1 1/4" and 2" Clearance of 1 1/2" between wall and wall rail Non-slip surface Level platforms (4 ft 4 ft) at every 30 ft, at top, at bottom, at change of direction NOTES: Gravel Parking lot to Conservation Land

LOCATION: Veterans Monument SITE ACCESS, PATH OF TRAVEL, ENTRANCES Site Access Accessible path of travel from passenger disembarking area and parking area to accessible entrance Disembarking area at accessible entrance Surface evenly paved or hard-packed No ponding water Path of Travel Path does not require the use of stairs Path is stable, firm, and slip resistant 3 ft wide minimum Slope maimum 1:20 (5%) and maimum cross pitch is 2% (1:50). Continuous common surface, no changes in level greater than 1/2 inch Any objects protruding onto the pathway must be detected by a person with a visual disability using a cane Objects protruding more than 4" from the wall must be within 27" of the ground, or higher than 80" Curb on the pathway must have curb cuts at drives, parking, and drop-offs Entrances Primary public entrances accessible to person using wheelchair, must be signed, gotten to independently, and not be the service entrance Level space etending 5 ft from the door, interior and eterior of entrance doors Minimum 32" clear width opening (i.e. 36" door with standard hinge) At least 18" clear floor area on latch, pull side of door Door handle no higher than 48" and operable with a closed fist Vestibule is 4 ft plus the width of the door swinging into the space Entrance(s) on a level that makes elevators accessible Door mats less than 1/2" thick are securely fastened Door mats more than 1/2" thick are recessed Grates in path of travel have openings of 1/2" maimum Signs at non-accessible entrance(s) indicate direction to accessible entrance Emergency egress- alarms with flashing lights and audible signals, sufficiently lighted NOTES: Small parking area with foot path trails

LOCATION: Veterans Monument STAIRS and DOORS Stairs No open risers Nosings not projecting Treads no less than 11" wide on both sides 34"-38" above tread Handrail etends a minimum of 1 ft beyond top and bottom rise (if no safety hazard and space permits) Handgrip oval or round Handgrip has a smooth surface Handgrip diameter between 1 1/4" and 1 1/2" 1 1/2" clearance between wall and handrail Doors Minimum 32" clear opening At least 18" clear floor space on pull side of door Closing speed minimum 3 seconds to within 3" of the latch Maimum pressure 5 pounds interior doors Threshold maimum 1/2" high, beveled on both sides Hardware operable with a closed fist (no conventional door knobs or thumb latch devices) Hardware minimum 36", maimum 48" above the floor Clear, level floor space etends out 5 ft from both sides of the door Door adjacent to revolving door is accessible and unlocked Doors opening into hazardous area have hardware that is knurled or roughened NOTES: No built structures

LOCATION: Veterans Monument RESTROOMS- also see Doors and Vestibules 5 ft turning space measured 12" from the floor At least one Sink: Clear floor space of 30" by 48" to allow a forward approach Mounted without pedestal or legs, height 34" to top of rim Etends at least 22" from the wall Open knee space a minimum 19" deep, 30" width, and 27" high Cover eposed pipes with insulation Faucets operable with closed fist (lever or spring activated handle) At least one Stall: Accessible to person using wheelchair at 60" wide by 72" deep Stall door is 36" wide Stall door swings out Stall door is self closing Stall door has a pull latch Lock on stall door is operable with a closed fist and 32" above the floor Coat hook is 54" high Toilet 18" from center to nearest side wall 42" minimum clear space from center to farthest wall or fiture Top of seat 17"-19" above the floor Grab Bars On back and side wall closest to toilet 1 1/4" diameter 1 1/2" clearance to wall Located 30" above and parallel to the floor Acid-etched or roughened surface 42" long Fitures Toilet paper dispenser is 24" above floor One mirror set a maimum 38" to bottom (if tilted, 42") Dispensers (towel, soap, etc) at least one of each a maimum 42" above the floor NOTES: No built structures

LOCATION: Veterans Monument FLOORS, DRINKING FOUNTAINS, TELEPHONES Floors Non-slip surface Carpeting is high-density, low pile, non-absorbent, stretched taut, securely anchored Corridor width minimum is 3 ft Objects (signs, ceiling lights, fitures) can only protrude 4" into the path of travel from a height of 27" to 80" above the floor Drinking Fountains Spouts no higher than 36" from floor to outlet Hand operated push button or level controls Spouts located near front with stream of water as parallel to front as possible If recessed, recess a minimum 30" width, and no deeper than depth of fountain If no clear knee space underneath, clear floor space 30" 48" to allow parallel approach Telephones Highest operating part a maimum 54" above the floor Access within 12" of phone, 30" high by 30" wide Adjustable volume control on headset so identified SIGNS, SIGNALS, AND SWITCHES Switches, Controls, and Signs Switches and controls for light, heat, ventilation, windows, fire alarms, thermostats, etc, must be a minimum of 36" and a maimum of 48" above the floor for a forward reach, a maimum of 54" for a side reach Electrical outlets centered no lower than 18" above the floor Warning signals must be visual as well as audible Signs Mounting height must be 60" to centerline of the sign Within 18" of door jamb or recessed Letters and numbers at least 1 1/4" high Letters and numbers raised.03" Letters and numbers contrast with the background color NOTES: No built structures

LOCATION: Veterans Monument SWIMMING POOLS- accessibility can be via ramp, lifting device, or transfer area Ramp at least 34" wide with a non-slip surface etending into the shallow end, slope not eceeding 1:6 with handrails on both sides Lifting device Transfer area 18" above the path of travel and a minimum of 18" wide Unobstructed path of travel not less than 48" wide around pool Non-slip surface LOCATION: Veterans Monument SHOWER ROOMS- Showers must accommodate both wheel-in and transfer use Stalls 36" by 60" minimum, with a 36" door opening Floors are pitched to drain the stall at the corner farthest from the entrance Floors are non-slip surface Controls operate by a single lever with a pressure balance miing valve Controls are located on the center wall adjacent to the hinged seat Shower heads attached to a fleible metal hose Shower heads attached to wall mounting adjustable from 42" to 72" above the floor Seat is hinged and padded and at least 16" deep, folds upward, securely attached to side wall, height is 18" to the top of the seat, and at least 24" long Soap trays without handhold features unless they can support 250 pounds 2 grab bars are provided, one 30" and one 48" long, or one continuous L shaped bar Grab bars are placed horizontally at 36" above the floor line LOCATION: Veterans Monument PICNICKING A minimum of 5% of the total tables must be accessible with clear space under the table top not less than 30" wide and 19" deep per seating space and not less than 27" clear from the ground to the underside of the table. An additional 29" clear space (totaling 48") must etend beyond the 19" clear space under the table to provide access For tables without toe clearance, the knee space under the table must be at least 28" high, 30" wide, and 24" deep. Top of table no higher than 32" above ground Surface of the clear ground space under and around the table must be stable, firm and slip-resistant, and evenly graded with a maimum slope of 2% in all directions Accessible tables, grills, and fire rings must have clear ground space of at least 36" around the perimeter NOTES: No built structures

Facility Inventory LOCATION: Three Rivers Well Field ACTIVITY EQUIPMENT Tables & Benches NOTES Access to Open Spaces Back and Arm Rests Adequate Number Picnic Facilities Height of Cooking Surface Grills Trash Cans Picnic Shelters Located near accessible water fountains, trash can, restroom, parking, etc Surface material Trails Dimensions Rails Signage (for visually impaired) Entrance Pools Location from accessible parking Safety features i.e. warning for visually impaired Swimming Facilities Location from accessible path into water Beaches Location from accessible parking Shade provided All Play Equipment i.e. swings, slides Same eperience provided to all Play Areas (tot lots) Enough space between equipment for wheelchair Game Areas: Berm cuts onto courts *ballfield Height *basketball Equipment Dimensions *tennis Spectator Seating Boat Docks Arm Rests Fishing Facilities Bait Shelves Equipment Fish Cleaning Tables Programming Learn-to-Swim Are special programs at your Guided Hikes facilities accessible? Interpretive Programs Services and Technical Assistance Information available in alternative formats i.e. for visually impaired Process to request interpretive services (i.e. sign language interpreter) for meetings NOTES: It is an open mown field that you can walk around on.

LOCATION: Three Rivers Well Field PARKING Total Spaces Required Accessible Spaces Up to 25 1 Space 26-50 2 Spaces 51-75 3 Spaces 76-100 4 Spaces 101-150 5 Spaces 151-200 6 Spaces 201-300 7 Spaces 301-400 8 Spaces 401-500 9 Spaces Specification for Accessible Spaces Yes No Comments/ Transition Notes Accessible space located closest to accessible entrance Where spaces cannot be located within 200 ft of accessible entrance, drop-off area is provided within 100 ft Minimum width of 13 ft includes 8 ft space plus 5 ft access aisle Van Space- minimum of 1 van space for every accessible space, 8 ft wide plus 8 ft aisle. Alternative is to make all accessible spaces 11 ft wide with 5 ft aisle. Sign with international symbol of accessibility at each space or pair of spaces Sign minimum 5ft, maimum 8ft to top of sign Surface evenly paved or hard-packed (no cracks) Surface slope less than 1:20, 5% Curbcut to pathway from parking lot at each space or pair of spaces, if sidewalk (curb) is present Curbcut is a minimum width of 3 ft, ecluding sloped sides, has sloped sides, all slopes not to eceed 1:12, and tetured or painted yellow RAMPS Slope Maimum 1:12 Minimum width 4 ft between hand rails on both sides if ramp is longer than 6 ft at 34" and 19" from ramp surface etend 12" beyond top and bottom Handgrip oval or round Handgrip smooth surface Handgrip diameter between 1 1/4" and 2" Clearance of 1 1/2" between wall and wall rail Non-slip surface Level platforms (4 ft 4 ft) at every 30 ft, at top, at bottom, at change of direction NOTES: No parking or Ramps

LOCATION: Three Rivers Well Field SITE ACCESS, PATH OF TRAVEL, ENTRANCES Site Access Accessible path of travel from passenger disembarking area and parking area to accessible entrance Disembarking area at accessible entrance Surface evenly paved or hard-packed No ponding water Path of Travel Path does not require the use of stairs Path is stable, firm, and slip resistant 3 ft wide minimum Slope maimum 1:20 (5%) and maimum cross pitch is 2% (1:50). Continuous common surface, no changes in level greater than 1/2 inch no paths just open field Any objects protruding onto the pathway must be detected by a person with a visual disability using a cane Objects protruding more than 4" from the wall must be within 27" of the ground, or higher than 80" Curb on the pathway must have curb cuts at drives, parking, and drop-offs Primary public entrances accessible to person using wheelchair, must be signed, gotten to independently, and not be the service entrance Level space etending 5 ft from the door, interior and eterior of entrance doors Minimum 32" clear width opening (i.e. 36" door with standard hinge) At least 18" clear floor area on latch, pull side of door Door handle no higher than 48" and operable with a closed fist Vestibule is 4 ft plus the width of the door swinging into the space Entrance(s) on a level that makes elevators accessible Door mats less than 1/2" thick are securely fastened Door mats more than 1/2" thick are recessed Grates in path of travel have openings of 1/2" maimum Signs at non-accessible entrance(s) indicate direction to accessible entrance Emergency egress- alarms with flashing lights and audible signals, sufficiently lighted NOTES: no grates, signage or usable structures

LOCATION: Three Rivers Well Field STAIRS and DOORS Stairs No open risers Nosings not projecting Treads no less than 11" wide on both sides 34"-38" above tread Handrail etends a minimum of 1 ft beyond top and bottom rise (if no safety hazard and space permits) Handgrip oval or round Handgrip has a smooth surface Handgrip diameter between 1 1/4" and 1 1/2" 1 1/2" clearance between wall and handrail Doors Minimum 32" clear opening At least 18" clear floor space on pull side of door Closing speed minimum 3 seconds to within 3" of the latch Maimum pressure 5 pounds interior doors Threshold maimum 1/2" high, beveled on both sides Hardware operable with a closed fist (no conventional door knobs or thumb latch devices) Hardware minimum 36", maimum 48" above the floor Clear, level floor space etends out 5 ft from both sides of the door Door adjacent to revolving door is accessible and unlocked Doors opening into hazardous area have hardware that is knurled or roughened NOTES: No stairs, doors, usable structure

LOCATION: Three Rivers Well Field RESTROOMS- also see Doors and Vestibules 5 ft turning space measured 12" from the floor At least one Sink: Clear floor space of 30" by 48" to allow a forward approach Mounted without pedestal or legs, height 34" to top of rim Etends at least 22" from the wall Open knee space a minimum 19" deep, 30" width, and 27" high Cover eposed pipes with insulation Faucets operable with closed fist (lever or spring activated handle) At least one Stall: Accessible to person using wheelchair at 60" wide by 72" deep Stall door is 36" wide Stall door swings out Stall door is self closing Stall door has a pull latch Lock on stall door is operable with a closed fist and 32" above the floor Coat hook is 54" high Toilet 18" from center to nearest side wall 42" minimum clear space from center to farthest wall or fiture Top of seat 17"-19" above the floor Grab Bars On back and side wall closest to toilet 1 1/4" diameter 1 1/2" clearance to wall Located 30" above and parallel to the floor Acid-etched or roughened surface 42" long Fitures Toilet paper dispenser is 24" above floor One mirror set a maimum 38" to bottom (if tilted, 42") Dispensers (towel, soap, etc) at least one of each a maimum 42" above the floor NOTES: One ADA approved 'Port-o-Potty' with broken door

LOCATION: Three Rivers Well Field FLOORS, DRINKING FOUNTAINS, TELEPHONES Floors Non-slip surface Carpeting is high-density, low pile, non-absorbent, stretched taut, securely anchored Corridor width minimum is 3 ft Objects (signs, ceiling lights, fitures) can only protrude 4" into the path of travel from a height of 27" to 80" above the floor Drinking Fountains Spouts no higher than 36" from floor to outlet Hand operated push button or level controls Spouts located near front with stream of water as parallel to front as possible If recessed, recess a minimum 30" width, and no deeper than depth of fountain If no clear knee space underneath, clear floor space 30" 48" to allow parallel approach Telephones Highest operating part a maimum 54" above the floor Access within 12" of phone, 30" high by 30" wide Adjustable volume control on headset so identified SIGNS, SIGNALS, AND SWITCHES Switches, Controls, and Signs Switches and controls for light, heat, ventilation, windows, fire alarms, thermostats, etc, must be a minimum of 36" and a maimum of 48" above the floor for a forward reach, a maimum of 54" for a side reach Electrical outlets centered no lower than 18" above the floor Warning signals must be visual as well as audible Signs Mounting height must be 60" to centerline of the sign Within 18" of door jamb or recessed Letters and numbers at least 1 1/4" high Letters and numbers raised.03" Letters and numbers contrast with the background color NOTES: Not Applicable, None of the Above