Flight Systems. Replacement for KASSEC DESCRIPTION

Similar documents
GENSET CONTROL MODULE A121A / A241A

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

DEEP SEA ELECTRONICS PLC

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

GCU-10. Automatic Engine Control Unit Operators Manual

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller.

DEEP SEA ELECTRONICS PLC

DKG-114 MANUAL AND REMOTE START UNIT

60 Series Engine Controls

DEEP SEA ELECTRONICS PLC

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

GSC300 Auto Start Engine Controller

DEEP SEA ELECTRONICS PLC

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

DSEULTRA DSE6000 Quick Start Guide Document Number



R-200A R-200B Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

Installation Instructions & Users Manual

PRODUCT SERIES: DPG-2100

DKG-705 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT WITH PARALLEL TO MAINS AND DUAL GENSET PARALLEL FEATURES

ENGINE PROTECTION BOARD PDM1

Application Engineering Europe

DEEP SEA ELECTRONICS PLC

Deep Sea Electronics Plc

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

TG350 User Manual. Manual Revision: Min. FW Revision: Date Released: 09/01/ DYNAGEN Technologies Inc

R-200A R-200C Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Deep Sea Electronics Plc

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

ANALOG CONTROL PANEL

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Generator Sets Controller 210. Operation Manual. Ver1.0

DKG-109 AUTOMATIC MAINS FAILURE UNIT

Generator Start Control Module

Model H30 Operation Manual

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

RVS-DN Digital Reduced Voltage Motor Starter

DKG-215 MANUAL AND REMOTE START UNIT

QUICK INSTALLATION GUIDE

GSC300 Auto Start Engine Controller

DGC-2020 DIGITAL GENSET CONTROLLER

Designed for ease of integration with automation systems

PowerView PV380-R2 Mechanical Configuration

WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR

Red #22 Power. Red #14. Brown #18. Ign/Acc/Start. White#14. Tachometer Foot-Brake Door Pin Pos Trunk/Hatch (open) (-) while running Lock Arm

EPM72 Engine Protection Module

Generator Start Control Module

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Lt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red

DEEP SEA ELECTRONICS PLC

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

System Programming Instructions

DEEP SEA ELECTRONICS PLC

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Three-Phase Soft Starters

i n s t r u c t i o n m a n u a l

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

R-100 Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

INSTALLATION GUIDE. FCC ID NOTICE

Generator Controller Manual

Quick Start Guide TS 910

Be2K-Plus AMF panel control wiring --

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

INSTALL GUIDE IDL-IDS(RS)-BZ2B-[ADS-BZ2]-EN

The measurements module provides the following engine features information:

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

HGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

RVS-DX Digital Reduced Voltage Motor Starter

Be-K3 OEM s Manual --

Alarms & Remote Start

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

PowerCommand. GenSet Controls

Transcription:

DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most LP, diesel, NG, and gas generators Easy to install with simple mounting and self learning option Added features for improved reliability and engine protection SPECIFICATIONS Compatible with KASSEC 1.5, 1 2 or 24 VDC (90353 / 90354) Adjustable cyclic engine cranking circuit (3 to 30 seconds) 4 crank disconnects available (Mag pickup, alternator, DC, and AC) Adjustable crank disconnect speed 1 0-85% of nominal speed Adjustable overspeed alarm 11 0-1 85% of nominal speed Adjustable low oil pressure delay and loss of speed sensor (3-30 seconds) Adjustable cooldown cycle (0-600 seconds) 8 amp relay contacts for fuel/ignition and start solenoid Overcrank, low oil pressure, overspeed, loss of speed sensor, and 4 auxiliary shutdown alarms 2 amp alarm outputs for external notification 2 amp common alarm output Diagnostic indicators for all outputs Optional self learning setup mode RS485 serial communications port

INSTALLATION The is a drop-in replacement for the 90353/90354. When replacing a failed control, mounting and connections are all compatible with the original 90353/90354. For new installations refer to the provided wiring diagrams and terminal descriptions. TERMINAL DESCRIPTIONS TERMINAL #1 Constant battery source for fuel/ignition output (#2), start solenoid output (#3), and fault indicator outputs (#1 3-1 8, #23). TERMINAL #2 Battery voltage output to fuel/ignition (MAX 8 AMPS). TERMINAL #3 Battery voltage output to start solenoid (MAX 8 AMPS). TERMINAL #4 Switched battery source for controller logic. The AUTO input will supply a minimum of 1 AMP at 6 VDC. Maximum voltage on TERMINAL #4 is 36VDC. TERMINAL #5 Magnetic pickup input. TERMINAL #6 Alternator R-terminal input. TERMINAL #7 DC disconnect input (6-36 VDC). TERMINAL #8 Positive voltage (6-36VDC) to initiate AUTO START. TERMINAL #9 Battery ground for controller logic. TERMINAL #1 0 Open. TERMINAL #11 Open. TERMINAL #1 2 AC disconnect (30-1 50 VAC). TERMINAL #1 3 Overcrank alarm output (2 AMPS). TERMINAL #1 4 Low oil pressure alarm output (2 AMPS). TERMINAL #1 5 Fault 1 alarm output (2 AMPS). TERMINAL #1 6 Fault 2 alarm output (2 AMPS). TERMINAL #1 7 Fault 3 alarm output (2 AMPS). TERMINAL #1 8 Fault 2 alarm input (switched to ground). TERMINAL #1 9 Fault 4 alarm input (switched to ground). TERMINAL #20 Fault 4 alarm output (2 AMPS). TERMINAL #21 Fault 3 alarm input (switched to ground). TERMINAL #22 Fault 1 alarm input (switched to ground). TERMINAL #23 Common alarm output (2 AMPS). TERMINAL #24 Low oil pressure alarm input (switched to ground).

LAYOUT FAULT LEDs POWER LEDs DELAY SETTINGS STATUS LED WIRING STOP START COMMON ALARM LED

LEARNING MODE In learning mode, the controller will look at all the crank disconnects being used and adjust the nominal speed of the controller accordingly. After the setup is complete, the nominal speed of the generator is saved and the controller will use these settings on startup. 1. Remove power from TERMINAL #4 (AUTO) and wait 5 sec for the controller to power down. Set all adjustments to mid-range. Press and hold STOP while switching the power on. Continue to hold STOP until the COMMON ALARM light turns on. Release STOP and wait until the COMMON ALARM light blinks rapidly to indicate that the controller is ready to learn. NOTE: Pressing STOP will cancel the setup and return the controller to the default settings. 2. Press and hold START to manually start the generator. Allow the generator to stabilize at rated speed. Verify that the oil pressure indicator has turned off indicating that the oil pressure switch has opened. NOTE: The oil pressure indicator will display the status of the oil pressure switch TERMINAL #24 for the duration of the test. Verify that the correct condition is being displayed. With the engine not running, the oil pressure indicator should be on. 3. Fault indicators 1-4 will display which, if any, crank disconnects are detected. FAULT 1 - Mag Pickup #5 FAULT 2 - Alternator R-Terminal #6 FAULT 3 - DC Disconnect #7 FAULT 4 - AC Disconnect #1 2 If none of the fault indicators 1-4 turn on, then a valid crank disconnect has not been detected. Disconnect power to shutdown and diagnose the problem.

LEARNING MODE CONT. 4. With the generator running at rated speed and the oil pressure indicator off, press STOP to save the settings to memory. Wait for all fault indicators to turn off and the STATUS LED to blink once per second to indicate that the controller is now in standby mode. To perform an auto start test you, can activate remote start externally on TERMINAL #8, or press and release the START button. ADJUSTMENTS CRANK DELAY Adjust the on and off cycle time of the cyclic engine crank output (3-30 sec). CRANK DISC Adjust the percentage of nominal speed at which the crank will disconnect (1 0-85%). The factory default is a nominal speed of 5khz on TERMINAL #5, 300Hz on TERMINAL #6, and 60Hz on TERMINAL #1 2. OVERSPEED Adjust the percentage of nominal speed at which the overspeed alarm will shut down the engine (11 0-1 85%). Turn the overspeed adjustment to maximum to disable. LOP DELAY Adjust the time delay before the low oil pressure delay and speed sensor loss alarm will activate (3-30 sec). COOLDOWN Adjust the time that the generator will continue to run after the remote start signal is removed from TERMINAL #8 (0-1 0 minutes). Turn the cooldown adjustment to minimum to disable. ON-BOARD MANUAL START You can perform an auto start test by pressing the START button anytime the controller is in standby mode. To shutdown from an on-board manual start, press the STOP button and the controller will resume standby mode.

OPERATION Standby With battery voltage applied to TERMINAL #4 and ground on TERMINAL #9, the will default to standby mode. The PWR indicator should be on and the STATUS LED should be blinking once per second. While in standby mode, the controller will draw approximately 34mA of current at 1 2 VDC and 20mA at 24VDC. Auto Start While in standby mode, applying battery voltage to TERMINAL #8 will place the controller in auto start mode and begin the cranking sequence. The STATUS LED will flash rapidly. During cranking, determined by the Crank Delay adjustment (0-30sec), constant battery voltage from TERMINAL #1 will be switched to TERMINAL #2 and #3. The status of the fuel/ignition and start solenoid relays can be determined by the fuel and crank indicators. During crank rest, also set by the Crank Delay adjustment, both the fuel/ignition and start solenoid relays will be off or open. If the controller does not receive a crank disconnect signal within 5 cycles, the controller will go into overcrank shutdown. Crank Disconnects Crank disconnect is determined by the CRANK DISC adjustment, 1 0-85% of nominal speed. The default nominal speed of the controller is 5kHz on TERMINAL #5, 300Hz on TERMINAL #6 and 60Hz on TERMINAL #1 2. This will provide crank disconnect with a range of 500-4250Hz on TERMINAL #5, 30-255Hz on TERMINAL #6, and 6-51 Hz on TERMINAL #1 2. To alter the nominal speed of the controller, follow procedures for the SELF LEARNING mode. Auto Run If the controller sees a crank disconnect signal on TERMINAL #5, #6, #7, or #1 2, the crank relay will be locked out and fuel will remain on. The controller is now in run mode. The STATUS LED will cycle once per second to indicate run mode. The low oil pressure delay, determined by the LOP DELAY (0-30sec), starts timing out. If the ground signal is not removed from TERMINAL #24 before the end of the low oil pressure delay, the controller will shut down. The OIL PRESSURE indicator will illuminate as well as the COMMON ALARM. Both fuel/ignition (TERMINAL #2) and start solenoid (TERMINAL #3) will be disabled until reset. Loss of Speed Sensor If the magnetic pickup input (TERMINAL #5) or DC disconnect (TERMINAL #7) was found in either auto start or auto run mode, the loss of speed sensor fault is enabled. If the signal on either of these 2 inputs is lost during auto run mode and no other crank disconnect is found the controller will go into speed sensor failure and shut down the generator. The COMMON ALARM indicator will illuminate and the OVERCRANK indicator will cycle once per second.

Overspeed Shutdown Optionally the OVERSPEED adjustment can be set from 11 0-1 85% of nominal speed. If the frequency of the magnetic pickup input, alternator input, or VAC input exceeds the value of the OVERSPEED adjustment, the controller will go into overspeed and shut down the generator. The COMMON ALARM indicator will illuminate and the OVERCRANK indicator will flash rapidly about twice per second. Both the fuel/ignition and start solenoid outputs will be disabled until reset. Faults If any of the 4 fault input terminals (#1 8, #1 9, #21, or #22) are grounded during auto start or auto run mode, the controller will shut down the generator. Both the fuel/ignition (TERMINAL #2) and start solenoid (TERMINAL #3) will be disabled until reset. The corresponding fault indicator will illuminate and battery voltage will be supplied on the terminal indicating that fault. The COMMON ALARM output will be enabled as well. Cooldown Mode Optionally, you can set the controller to run a cooldown cycle set by the COOLDOWN adjustment (0-600 sec or 0-1 0 min). While in RUN mode, removing battery voltage from AUTO START (TERMINAL #8) will put the controller in cooldown mode and the generator will continue to run until the time delay expires. To disable cooldown mode, turn the COOLDOWN adjustment to minimum. All alarms are monitored during the cooldown cycle.