HYDRAULIC HW APPLICATION» Conveyors» Feeding mechanism of robots and manipulators» Metal working machines» Textile machines» Machines for agriculture» Food industries» Grass cutting machinery etc. CONTENTS Specification data...4 Permissible shaft Seal Pressure... Dimensions and mounting... 6 Permissible shaft loads... Shaft extensions... 7 Order code... 9 OPTIONS» Model- Spool valve, roll-gerotor» Wheel mount» Shafts- straight, splined and tapered» BSPP ports» Other special features GENERAL Displacement, [cm /rev.] Max. Speed, Max. Torque, Max. Output, [kw] Max. Pressure Drop, [bar] Max. Oil Flow, [l/min] Min. Speed, Pressure fluid O Temperature range, [C] Optimal Viscosity range, [mm /s] Filtration 16 0 16 0 96 9 17,6 1 0 4 Mineral based- HLP(DIN 14) or HM(ISO 674/4) -0 0 ISO code 0/16 (Min. recommended fluid filtration of micron) Oil flow in drain line Pressure Losses Pressure drop (bar) 0 140 Viscosity (mm /s) 0 0 Oil flow in drain line (l/min), 1,,,
SPECIFICATION DATA Type Displacement, [cm /rev.] Max. Speed, Max. Torque Max. Output, [kw] Max. Pressure Drop, [bar] Max. Oil Flow [l/min] Max. Inlet Pressure, [bar] Max. Starting Pressure with Unloaded Shaft, [bar] Min. Starting Torque drop drop Min. Speed**, Weight, avg. [kg] HW 1 160 00 00 1 16 7 476, 16, 19, 0 4 60,7 1, 14, 17, 0 4 44 4 17,6 1,6 0 60 6 9, 14,6 01, 4 4 60 17,4 19,6 0 70 41, 49, 1,, 9 61 64, 70 17 19, 0 70, 7,4 1,7 9 7 69 16, 1,7 0 6, 61, 1,9 00 00 1 9 16, 1,7 0 66,4 7,9 16, 14,9 6 9 16,4 1,7 0 69,7 76, 16, * Intermittent operation: the permissible values may occur for max. % of every minute. ** For speeds of RPM or lower, consult factory or your regional manager. 1. Intermittent speed and intermittent pressure drop must not occur simultaneously!. Recommended filtration is per ISO cleanliness code 0/16. A nominal filtration of micron or better.. Recommended using a premium quality, anti-wear type mineral based hydraulic oil HLP(DIN14) or HM (ISO 674/4). If using synthetic fluids consult the factory for alternative seal materials. 4. Recommended minimum oil viscosity 1 mm²/s at operating temperatures.. Recommended maximum system operating temperature - ºC. 6. To assure optimum motor life fill with fluid prior to loading and run at moderate load and speed for -1 min. 4
SPECIFICATION DATA Type Displacement, [cm /rev.] Max. Speed, Max. Torque Max. Output, [kw] Max. Pressure Drop, [bar] Max. Oil Flow [l/min] Max. Inlet Pressure, [bar] Max. Starting Pressure with Unloaded Shaft, [bar] Min. Starting Torque drop drop Min. Speed**, Weight, avg. [kg] HW 0 70 400 470 00 0 47, 16 9 94 16, 1,7 0 77,6 16,9 69, 0 44 96 1, 17, 00 79, 6 17,1 96, 19 7 96 9 1, 16,7 1 1 7,7 0, 17, 470,6 19 191 9 1,6 1,6 10 16,4, 1, 0,4 149 179 91 1, 1,9 140 1 74,6, 1,6 0 140 16 16 164 9 4 9,4 9,0 1, 1,4 10 1 10 14 7, 7,9, 4,4 19,0 19,1 * Intermittent operation: the permissible values may occur for max. % of every minute. ** For speeds of RPM or lower, consult factory or your regional manager. 1. Intermittent speed and intermittent pressure drop must not occur simultaneously!. Recommended filtration is per ISO cleanliness code 0/16. A nominal filtration of micron or better.. Recommended using a premium quality, anti-wear type mineral based hydraulic oil HLP(DIN14) or HM (ISO 674/4). If using synthetic fluids consult the factory for alternative seal materials. 4. Recommended minimum oil viscosity 1 mm²/s at operating temperatures.. Recommended maximum system operating temperature - ºC. 6. To assure optimum motor life fill with fluid prior to loading and run at moderate load and speed for -1 min.
DIMENSIONS AND MOUNTING DATA Port A Port B P (A,B) T - Motor Mounting Surface Standard Rotation Viewed from Shaft End Port A Pressurized - CW Port B Pressurized - CCW Reverse Rotation Viewed from Shaft End Port A Pressurized - CCW Port B Pressurized - CW Type HW 1 HW 160 HW 00 HW HW HW 00 HW 1 HW 0 HW 70 HW 400 HW 470 HW 00 HW HW 0 L, mm L 1, mm 140, 17,4 14,0 1, 11,0 7, 1,, 1,0 4, 164, 41,4 166, 4, 171,0 4,0 174,0 1,0 17,0 4, 1,0 6,0 19, 69,4 197,0 74,1 199,0 76,0 P T (A,B) Versions 4 7 x -14UNF, xg½ O-ring 7 16-0UNF, G¼ O-ring / / 6
SHAFT EXTENSIONS K - 1 1/4" straight, Parallel key "x 16 16 "x1 ½" BS46 M - ø straight, Parallel key Axx DIN 6 max. max. L -ø1¼" splined 14T, DP1/4 ANSI B9.1-1976 Norm KB - ø tapered 1:, Parallel key "x 16 16 "x1¼" BS46 Max. Torque 9 danm T -1½" tapered 1:, Parallel key 16 "x 16 "x1 ¼" BS46 Max. Torque 10 danm R -1¼" tapered 1:, Parallel key 16 "x 16 "x1" BS46 7,9-0,06,64-0, max. 116 - Motor Mounting Surface 7
PERMISSIBLE SHAFT LOADS Pr dan 7000 6000 000 00 dan 00 dan 4000 000 000 00 1 0-60 -40-0 0 0 40 60 0 0 10 mm 1 - Bearing curve: The curve applies to a B bearing life of 000 hours at 0 RPM. - Shaft curve: The curve represents Max. permissible radial shaft load with safety factor :1. MAX. PERMISSIBLE SHAFT SEAL PRESSURE HW... motors with drain connection: The shaft seal pressure equals the pressure in the drain line. P bar 00 10 0 0 - continuous operations - intermittent operations 0 70 0 00 00 400 00 600 n, min -1
ORDER CODE HW 1 4 Pos.1 - Displacement code 1-16,00 [cm /rev] 160-1,00 [cm /rev] 00-01,0 [cm /rev] -,00 [cm /rev] -,00 [cm /rev] 00-00,00 [cm /rev] 1-14, [cm /rev] 0-47,0 [cm /rev] 70-69,00 [cm /rev] 400-96,0 [cm /rev] 470-470,60 [cm /rev] 00-0,40 [cm /rev] - 6,00 [cm /rev] 0-0,00 [cm /rev] Pos. - Ports - BSPP (ISO ) 4 - SAE (ANSI B1.1-19) Pos. 4 - Special Features (see page ) Pos. - Design Series omit - Factory specified Pos. - Shaft Extensions* K - 1¼"[1,] straight, Parallel key / "x 16 / 16 "x1½" BS46 KB - ø tapered 1:, Parallel key / "x 16 / 16 "x1¼" BS46 L - 1¼"[1,] splined 14T, ANSI B9.1-1976 M - ø straight, Parallel key Axx DIN 6 R - 1¼"[1,] Tapered 1:, Parallel key / "x 16 / 16 "x1 BS46 T - 1½"[,1] Tapered 1:, Parallel key / 16 ''x / 16 ''x1¼" BS46 NOTE: * The permissible output torque for shafts must not be exceeded! The hydraulic motors are mangano-phosphatized as standard. 9