Applicable bore size. CC-Link. EtherNet/IP. Decentralized Serial Wiring. EtherCAT I/O. Serial unit: EX600 IP67 compliant. Serial unit: EX500

Similar documents
F Kit. D-sub. connector. D-sub. connector) Compatible network DeviceNet PROFIBUS DP. CC-Link. Compatible D-sub connector. Output

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

5 Port Solenoid Valve

5 Port Solenoid Valve

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

5 Port Solenoid Valve

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

VQ1000. How to Order Manifold. Kit type

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

Fieldbus System (Output device for driving 5 port solenoid valves)

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

How to Order Manifold. Kit type L8 B4 B6 B8 LM

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VQ Port Solenoid Valve

5 Port Solenoid Valve

5 Port Solenoid Valve

5 Port Solenoid Valve

3 Port Solenoid Valve

Pilot Operated 2 Port Solenoid Valve for Dry Air

5 Port Solenoid Valve

SS5Y 3 05 U C6. Series SY3000/5000 Base Mounted Monifold Stacking Type/DIN Rail Mounted Individual Wiring

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Fieldbus System (Gateway Decentralized Type)

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Series SY3000/5000/7000

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

Series SV1000/2000/3000/4000

SMC guide to ATEX compliant products

New Concept Connector Type Manifold

5 Port Solenoid Valve

Base Mounted Plug-in Unit

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Series SY3000/5000 How to Order Manifold

5 Port Solenoid Valve

Base Mounted Plug-in/Plug Lead: Single Unit

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Series SY3000/5000/7000

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

5 Port Solenoid Valve Plug Lead Type

4/5 Port Solenoid Valve

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

3 Port Solenoid Valve

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VQZ1000/2000/3000 Single Unit

Series SY3000/5000 Base Mounted Manifold Stacking Type/DIN Rail Mounted Connector Box 24V. D side D. Blanking plate assembly SX A

4 Port Solenoid Valve

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Specifications. Fluid Ambient and fluid temperature ( C)

4 Port Solenoid Valve

Series VP3145/3165/3185

Plug Lead Unit: Flip Type

Non-Contact Sensor for Workpiece Placement Verification

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

0.35 W (Without light)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Gateway Type Serial Transmission System

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Pilot Operated 2 Port Solenoid Valve for Dry Air

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

Series PCW. PC Wiring System

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

4/5 Port Solenoid Valve

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Example. U side. Stations SY5000

How to Order Manifold. Option Symbol

3 Port Solenoid Valve

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

1 station. 3 Port Solenoid Valve. VV100 Series. Highly Integrated Unit Manifold

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

5 Port Solenoid Valve

3 Port 3 Position Valve

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

3 Port Solenoid Valve

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Transcription:

5 Port Solenoid Valve Series C000 Metal Seal Rubber Seal Compact and large flow Type (Series) Manifold pitch (mm) C000 5 6. 0.7.7 7. 0..0 to ø Note) Flow characteristics: position single, / 5/ (/ R/R) IP67 enclosure compatible Dusttight and immersible type (ased on IEC605) (For kits S, T, L and M) Connector type manifold pplicable to EX600 (Input/Output) serial transmission system (Fieldbus system) vailable for DeviceNet, PROFIUS DP, CC-Link, EtherNet/IP and EtherCT Fieldbus protocols Max. units Note) can be connected in any order. The unit to connect input device such as an auto switch, pressure switch and flow switch, and the unit to connect output device such as a solenoid valve, relay and indicator light can be connected in any order. Note) Except SI unit wide variety of prepackaged wiring configurations F Kit Kit Kit (D-sub connector) P Kit T L M S Kit (Serial transmission) Flow characteristics Note) Metal seal Rubber seal C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv nalogue Input Unit can be connected with analogue input device. s well as a Digital (switch) Input/Output Unit, a unit applicable to analogue signal is provided, and can be connected with various device for control. Self-diagnosis function It is possible to ascertain the maintenance period and identify the parts that require maintenance, by an input (sensor) open circuit detecting function and an input/output signal of ON/OFF counter function. lso, the monitoring of input/output signal and the setting of parameters can be performed with a Handheld Terminal. (Flat ribbon cable) pplicable cylinder size (mm) Outstanding response times and long service life (Metal seal: Single type with light/surge voltage suppressor) C0: 7 ms ± ms; 0 million cycles The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. ll kits use multi-pin connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. ccommodates gateway-type serial wiring Gateway unit types include DeviceNet, PROFIUS DP, CC-Link, and EtherNet/IP. ecause just one gateway unit controls up to branch lines, it offers much more freedom in choosing valve mounting locations in comparison to other serial units. Manifolds and input blocks can be mounted near the actuator, allowing for use of short air piping or electric wiring. The package wiring with connector cable reduces the potential for incorrect wiring and improves wiring efficiency. single cable from the gateway provides both signal and power to each branch, thus eliminating the need for separate power connections for each manifold valve and input block. The input block also employs a multi-pin connector so that the number of stations can be changed easily, as with the manifold. (Terminal block box) (Lead wire) Kit (Circular connector) SJ J VF VP S0700 5 C C Z VFS VFR 7 5 core cable 6 pins Protective enclosure conforms to IP 67 5 pins 6 pins, 0 pins Protective enclosure conforms to IP 67 Protective enclosure conforms to IP 67 Protective enclosure conforms to IP 67 Our six standard wiring packages bring a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards. The S Kit is compatible with a combined I/O unit. (Not applicable to Gateway unit) 7

Series C000 ase Mounted: Variations Sonic Conductance C[dm /(s bar)] Values: CYL EXH / 5/ Single/Double position (Closed center) pplicable bore size Compatible network DeviceNet PROFIUS DP CC-Link EtherNet/IP EtherCT I/O Serial unit: EX600 IP67 compliant Gateway application Compatible network DeviceNet PROFIUS DP EtherNet/IP Decentralized Serial Wiring Gateway application requires a gateway unit and communication cable separately. Please contact for more details. Serial unit: EX500 IP67 compliant S Kit Serial transmission Compatible network DeviceNet PROFIUS DP CC-Link EtherCT PROFINET Output Compatible network DeviceNet PROFIUS DP CC-Link S-Interface CNopen EtherNet/IP I/O Serial unit: EX60 IP0 compliant IP67 compliant Serial unit: EX50 IP67 compliant Compatible network CC-Link Output Serial unit: EX6 IP67 compliant Series C000 Metal seal Rubber seal C00 C0 6. 6. 7. 6. to ø Cylinder verage Speed Series C000 verage speed (mm/s) 00 700 600 500 00 00 00 0 0 Series CJ Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CM Pressure 0.5 MPa Load ratio 50% Stroke 00 mm This chart is provided as guidelines only. For performance under various conditions, use 's Model Selection Program before making a judgment. ore size Series M, C Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open. The average speed of the cylinder is obtained by dividing the stroke by the total stroke time. The load ratio is obtained by the following formula: ((Load mass x.)/theoretical output) x 0% Series CS/CS Pressure 0.5 MPa Load ratio 50% Stroke 00 mm ø6 ø ø6 ø0 ø5 ø ø0 ø0 ø50 ø6 ø0 ø0 ø5 ø ø60 Vertically upward Horizontal

5 Port Solenoid Valve Series C000 F Kit D-sub connector D-sub connector Compatible D-sub connector ( that complies with) MIL standard. 5pins Conditions P Kit Flat ribbon cable Flat ribbon cable Compatible with ribbon cable (flat that complies connector) with MIL standard. 6pins/0pins T Kit Terminal block box Terminal block box (Terminal blocks) Terminals are concentrated in compact clusters within the terminal block box. ase mounted Series CJ Series CM Series M, C Series CS/CS Tube x Length T060 x m T75 x m T x m C000 Speed controller S00F-06 S00F- S00F- Silencer N0-0 N0-0 ( L Kit Electrical entry Lead wire IP67 enclosure with use of multiple wire cable with sheath and waterproof connector ) M Kit Circular connector Circular connector IP67 enclosure ( ) with use of waterproof multiple connector IP67 compliant IP67 compliant IP67 compliant SUP port EXH, (P, R) Port size Cylinder port, (, ) <SUP port> C (For ø) C (For ø) Rc / C (For ø) N7 (ø/") (NPT, NPTF, G) N (ø5/6") N (ø/") <EXH port> Rc / Rc / Rc / Rc / (ottom ported) (NPT, NPTF, G) (NPT, NPTF, G) SJ J VF VP S0700 5 C C Z VFS VFR 7 Conditions (With SGP (Stainless steel gas piping)) ody ported Tube x Length C000 Speed controller Silencer Series M, C Series CS/CS SGP x m S0-0 N0-0

ase Mounted Plug-in Unit Series C000 How to Order Manifold VV5QC 0 0 TD0 q w e r! F P L T Kit M VV5QC 6 0 SDQW Series C000 ase mounted plug-in Enter EX600-compliant Enter only for S kit y t u i o!0 S Kit Enter EX50-compliant Enter only for S kit q Stations 0 station 6 6 stations The minimum or maximum number of stations differs depending on the electrical entry. (Refer to r) Note) In the case of compatibility with the S kit/s Interface the maximum number of solenoids is as shown below, so please be careful of the number of stations. in/ out: Maximum solenoids in/ out: Maximum solenoids D side stations 5 6 7 n U side Stations are counted from station on the D-side. w Cylinder port size C With ø One-touch fitting C With ø One-touch fitting C With ø One-touch fitting 0 Rc / Note) 0 Rc / Note) ottom ported Rc / Note) CM Mixed Note) esides Rc, also compatible with G, NPT/NPTF. Part number displayed is as shown below. e Thread type Nil Rc F G T NPT/NPTF t End plate type (Enter EX600-compliant S kit only.) Nil Without end plate M connector power supply (Max. supply current ) 7/ inch connector power supply (Max. supply current ) Note) Without SI unit, the symbol is nil. y SI unit output polarity SI unit output polarity EX50 integrated-type (for I/O) serial transmission system DeviceNet PROFIUS DP CC-Link S-Interface CNopen EtherNet/IP Nil + COM N COM SI unit output polarity Nil N + COM COM SI unit output polarity Nil N DeviceNet EX60 integrated-type (for output) serial transmission system PROFIUS DP CC-Link SI unit output polarity Nil N + COM COM DeviceNet PROFIUS DP CC-Link Note) Leave the box blank for the SI unit COM without SI unit (SDO). u I/O unit stations (Enter EX600-compliant S kit only.) Nil i Symbol Nil 0 + COM COM EX500 gateway-type serial transmission system DeviceNet EtherCT PROFINET EtherNet/IP EX600 integrated-type (for I/O) serial transmission system (Fieldbus system) With input block With input blocks No. of blocks Without SI unit (SD0) Without input block With input block With input blocks With input blocks PROFIUS DP Note ) Without SI unit, the symbol is nil. Note ) SI unit is not included in I/O unit stations. Note ) When I/O unit is selected, it is shipped separately, and assembled by customer. Refer to the attached operation manual for mounting method. Note ) Refer to page 50 for details of the enclosure. Number of input blocks (Enter only for S kit compliant with EX50) EtherNet/IP o Nil!0 EtherNet/IP Without input block M, inputs M, inputs M, inputs EtherCT Input block COM (Enter only for S kit compliant with EX50) Nil PNP sensor input or without input block N NPN sensor input! Option Nil K N Number of input blocks (Enter only for S kit compliant with EX50) Special wiring specifications (except for double wiring) With name plate (available for T kit only)

ase Mounted Series Plug-in Unit C000 SJ r Kit Designation/Electrical Entry/Cable Length S Kit (Serial transmission kit (Fieldbus system) : EX600 integrated-type) S Numbers in parentheses represent the maximum number of solenoids in the case of mixed single and double wiring. The total number of solenoids determines the maximum number of stations. When ordering mixed wiring, please add the option symbol -K. Kit (Serial transmission kit: EX500 gateway-type) S Kit (Serial transmission kit: EX60 integrated-type (I/O)) J IP0 compliant SI unit: EX60 Symbol SI unit: EX600 IP67 compliant IP67 compliant SI unit: EX500 Serial kit without SI unit SD60 Serial kit for DeviceNetTM SD6Q Serial kit for PROFIUS-DP to 6 stations SD6N () Serial kit for CC-LINK SD0 Serial kit without SI unit SD6V Device Net, PROFIUS DP, SD6ZE EtherNet/IP SD EtherCT EtherNet/IP SD6D Kit TM S (Serial transmission kit: EX50 integrated-type (for I/O)) SI unit: EX50 S to 6 stations (6) IP67 compliant SD0 SDQ SDN SDV SDT SDT SDTC Note ) SDTD Note ) SDY SDZEN Kit (Serial transmission kit: EX6 integrated-type (for output)) SD0 SN SN SNC SND SD SD SF SF SE SE IP67 compliant Protocol Number of outputs Communication connector Serial kit without SI unit M DeviceNet 6 M 6 PROFIUS DP D-subNote ) 6 M CC-Link 6 M EtherCT 6 M PROFINET 6 M EtherNet/IP 6 Serial kit without SI unit Serial kit for DeviceNetTM Serial kit for PROFIUS-DP Serial kit for CC-LINK S-i, in/out, slave modes, power supply systems S-i, in/out, slave modes, power supply systems S-i, in/out, slave modes, power supply systems S-i, in/out, slave modes, power supply systems to 6 stations () to stations () to stations () to stations () to stations () For CNopen For EtherNet/IP P Stations to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () to 6 stations (6) to 6 stations () Kit (Flat ribbon cable kit) VF VP S0700 5 C C Z VFS VFR 7 IP0 compliant Note) For a 0P flat ribbon cable, the cable assembly must be ordered separately. SI unit: EX6 to 6 stations (6) SDV Serial kit for CC-LINK F Kit (D-sub connector kit) M D-sub connector kit (5P) without cable D-sub connector kit (5P) with.5 m cable to 6 stations () D-sub connector kit (5P) with.0 m cable D-sub connector kit (5P) with 5.0 m cable Kit (Circular connector kit) PDC T Flat ribbon cable kit (6P) without cable Flat ribbon cable kit (6P) with.5 m cable Flat ribbon cable kit (6P) with.0 m cable Flat ribbon cable kit (6P) with 5.0 m cable MD0 MD MD MD Circular connector kit (6P) without cable Circular connector kit (6P) with.5 m cable to 6 stations () Circular connector kit (6P) with.0 m cable Circular connector kit (6P) with 5.0 m cable to 6 stations () to 6 stations () Flat ribbon cable kit (0P) without cable () Kit (Terminal block box kit) IP67 compliant IP0 compliant FD0 FD FD FD IP67 compliant PD0 PD PD PD IP67 compliant TD0 Terminal block box kit to 6 stations (0) L Kit (Lead wire kit) IP67 compliant LD0 Lead wire kit (5 core) 0.6 m lead wire LD Lead wire kit (5 core).5 m lead wire LD Lead wire kit (5 core).0 m lead wire to 6 stations () The maximum number of solenoids displayed in parentheses is applied to the special wiring specification (Option -K ). Note ) When selecting SI units with SDTC or SDTD specifications, there are limits to the supply current from the SI unit to the input block or valve. Refer to page 077 for details. Note ) When selecting D-sub S kit specifications only, IP0 is compatible. (ll other SI units are IP67 compliant.) Note ) For the SI unit part no., refer to page.

Series C000 How to Order Valves C 0 0 5 Series C000 C D E F Type of actuation SI unit Part No. Table EX600 Symbol position single () () Protocol type SD6Q DeviceNet TM SD6N PROFIUS DP SD6V CC-Link SD6ZE EtherNet/IP TM SD6D EtherCT EX60 Protocol Symbol type 5 (R) (P)(R) position double (metal) () () 5 (R) (P) (R) position double (rubber) () () 5 (R) (P) (R) position closed center () () 5 (R)(P)(R) Number of outputs Serial unit No. COM. (PNP) + COM. (NPN) EX600-SDN EX600-SDN EX600-SMJ EX600-SMJ EX600-SPR EX600-SPR EX600-SEN EX600-SEN EX600-SEC EX600-SEC Serial unit No. COM. (PNP) + COM. (NPN) EX60-SDN EX60-SDN DeviceNet TM 6 EX60-SDN EX60-SDN SN EX60-SPR EX60-SPR SN 6 EX60-SPR EX60-SPR PROFIUS DP SNC EX60-SPR5 EX60-SPR6 SND 6 EX60-SPR7 EX60-SPR EX60-SMJ EX60-SMJ CC-Link 6 EX60-SMJ EX60-SMJ SD EX60-SEC EX60-SEC EtherCT SD 6 EX60-SEC EX60-SEC SF EX60-SPN EX60-SPN PROFINET SF 6 EX60-SPN EX60-SPN SE EX60-SEN EX60-SEN EtherNet/IP SE 6 EX60-SEN EX60-SEN EX6 Symbol Protocol type SDV CC-Link (+ COM.) (NPN) 5 6 Serial unit No. EX6D-SMJ position exhaust center () () 5 (R) (P)(R) position pressure center () () 5 (R) (P) (R) position perfect () () 5 (R)(P)(R) Communication connector M D-sub M M M M Page P. Page P. Page P. Seal type 0 Metal seal Rubber seal C Function Nil R Y D Coil voltage 5 VDC Note) 6 VDC Note) S kit is only available for VDC. EX500 Symbol SD Standard type ( W) External pilot Low wattage type (0.5 W) Note ) When specifying more than one option, enter symbols in alphabetical order. Note ) Please select when you expect to energize the unit for extended periods of time. Refer to page for details. E Light/Surge voltage suppressor Nil With Without light, E with surge voltage supressor Protocol type DeviceNet TM PROFIUS DP EtherNet/IP TM Serial unit No. + COM. (NPN) COM. (PNP) EX500-Q00 F Manual override Nil: Non-locking push type (Tool required) : Locking type (Tool required) EX500-Q Page P. EX50 Symbol Protocol type Serial unit No. Page SDQ SDN SDV DeviceNet TM ( COM.) (PNP) PROFIUS DP ( COM.) (PNP) CC-Link (+ COM.) (NPN) EX50-SDN EX50-SPR EX50-SMJ S-Interface ( COM.) (PNP), ( in/ out, SDT EX50-SS slave modes, power supply systems) S-Interface ( COM.) (PNP), ( in/ out, SDT EX50-SS5 slave modes, power supply systems) P. S-Interface ( COM.) (PNP), ( in/ out, SDTC EX50-SS7 slave modes, power supply systems) S-Interface ( COM.) (PNP), ( in/ out, SDTD EX50-SS slave modes, power supply systems) SDY CNopen ( COM.) (PNP) EX50-SC SDZEN EtherNet/IP TM ( COM.) (PNP) EX50-SEN Refer to page 07 and Operation Manual, for details on the EX600 integrated-type (I/O). Refer to pages, 07, and 055 and Operation Manual for details on the EX500 gateway-type serial transmission system, EX50 integrated-type (I/O) serial transmission system and EX6 integrated-type (for output) serial transmission system respectively. For details about EX60 integrated type (for output), refer to page 06 and Operation Manual. Please download the Operation Manual via 's website, http://www.smcworld.com

ase Mounted Plug-in Unit Series C000 Manifold Options Refer to the catalog of series 000 for further information of options. lanking plate assembly V000-- Individual SUP spacer Individual EXH spacer V000-P-- 0 0 V000-R-- 0 0 SUP/EXH block plate V000-6 Throttle valve spacer V000-0- Residual pressure release valve perfect spacer V000-5- Note ) SUP stop valve spacer V000-7- Note ) Perfect spacers with residual pressure release valve cannot be combined with external pilot specifications. <EXH block plate> <SUP block plate> Interface regulator RQ000-00- - P SJ J VF VP S0700 5 C C Z VFS VFR 7

Series C000 Plug-in Unit Model ase Mounted Symbol position single () () 5 (R) (P)(R) position double (metal) () () 5 (R) (P) (R) position double (rubber) () () 5 (R) (P)(R) position closed center () () 5 (R) (P)(R) position exhaust center () () 5 (R) (P)(R) position pressure center () () 5 (R) (P)(R) position perfect () () 5 (R) (P)(R) Manifold Specifications Series C000 No. of solenoids position position Model Metal seal Single Rubber seal Metal seal Double Rubber seal Closed Metal seal center Rubber seal Exhaust Metal seal center Rubber seal Pressure Metal seal center Rubber seal Metal seal Perfect Rubber seal C0 C C00 C0 C00 C0 C00 C0 C500 C50 C600 C60, (P, ) Flow characteristics Note ) Response time (ms), 5, (, R, R) Standard: W 6. 0.7.7 0 or less 7. 0..0 5 or less 6. 0.7.7 or less 7. 0..0 5 or less 6. 0..6 5 or less 6. 0.. 50 or less 6. 0.7.7 5 or less 7. 0..0 50 or less 6. 0..6 5 or less 7. 0..0 50 or less.7 55 or less. 6 or less C[dm /(s bar)] b Cv C[dm /(s bar)] b Cv 6. 0..5 7. 0.. 6. 0..5 7. 0.. 5. 0..5 7.0 0.. 6. 0..5 7.0 0.. 6. 0.. 7.0 0...7. Weight (g) Low wattage or less 0 7 or less or less 60 5 or less 7 or less 5 or less 7 or less 0 5 or less 7 or less 5 or less 57 or less 500 6 or less Note ) C000: Cylinder port size Rc / Note ) Values represented in this column are based on JIS 75- (operating with clean air and a supply pressure of 0.5 MPa. Equipped with light/surge voltage suppressor. Values vary depending on the pressure as well as the air quality.) Values for double types are when the switch is ON. Standard Specifications Valve specifications Electrical specifications Valve Configuration Fluid Max. operating pressure Note ).0 Min. operating pressure Single Double position Proof pressure mbient and fluid temperature Lubrication Manual override Impact/Vibration resistance Enclosure Rated coil voltage llowable voltage fluctuation Coil insulation type Power consumption VDC (Current) VDC Metal seal Rubber seal ir MPa (0.7 MPa) 0.5 MPa 0. MPa 0.5 MPa 0.5 MPa 0. MPa.5 MPa to 50 C Note ) Not required Push type/locking type (tool required) option 50/0 m/s Note ) Dust proof (IP67 compliant) VDC ±% of rated voltage Equivalent to type W DC ( m), 0.5 W DC ( m) W DC ( m), 0.5 W DC ( m) Note ) Use dry air to prevent condensation at low temperatures. Note ) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. Vibration resistance: No malfunction occurred in a one-sweep test between 5 and 000Hz. Test was performed in the axial and right angle directions of the main valve and armature for both energized and de-energized states. Note ) Values in ( ) are for the low wattage (0.5 W) specification. Series ase model Connection type C000 VV5QC- F Kit: D-sub connector P Kit: Flat cable T Kit: Terminal block box S Kit: Serial transmission L Kit: Lead wire M Kit: Circular connector Piping specifications Port Port size Note ) direction, (P, R), (, ) C (For ø) C (For ø) Side P: Rc / C (For ø) R: Rc / Rc / Rc / ottom Note ) One-touch fittings in inch sizes are also available. Note ) n optional specification for special wiring is available to increase the maximum number of stations. Rc / Note ) pplicable stations F, L, M and P kits to 6 stations T kit to 6 stations S kit to 6 stations: EX50 to 6 stations: EX500 pplicable solenoid valves C00-5 C0-5 5 station weight (g) 50 S kit (without unit) Solenoid weight is not included.

S C000 kit (Serial transmission): For EX600 Integrated-type (I/O) Serial Transmission System VV5QC S Kit (Serial transmission kit: EX50) Power supply with M connector (6) 7.5 Digital input unit Input connector Power connector FE terminal 6 0 x M Mounting hole End plate 56.6 0.5 5.5 6 Output connector Marker groove 7 m + 66 Digital output unit Communication connector SI unit 7 m 7 / [ (R) port] /: /" Female thread (Rc, G, NPT/NPTF) / [ (P) port] /: /" Female thread (Rc, G, NPT/NPTF) / (External pilot port) /: /" Female thread (Rc, G, NPT/NPTF) ase Mounted L Valve plate L (n ) x 5 Indicator light Manual override Connector for handheld terminal D-side Stations 0.6 / (Pilot EXH port) /: /" Female thread (Rc, G, NPT/NPTF).5 Plug-in Unit 5 6 Series C000 7 5 65.5 n R.5 5 65.5 U-side 7.7 6.5.5 (6.5) 5.7 / / C C C [(), () port] 6.7 IP67 compliant.5 /: /" Female thread (Rc, G, NPT/NPTF) /: /" Female thread (Rc, G, NPT/NPTF) C: ø One-touch fitting C: ø One-touch fitting C: ø One-touch fitting 7 77. 5.5. SJ J VF VP S0700 5 C C Z VFS VFR 7 Formulas L = 5n + 6 L = 5n + L dimension: Without I/O unit For additional I/O unit, add 7 mm. m: I/O unit stations Dimensions L n L 56 L 0 n: Stations (Maximum 6 stations) 5 6 7 5 6 06 5 0 56 06 5 56 0 5 06 56 50 5 506 55 5 5

Series C000 S C000 kit (Serial transmission): For EX600 Integrated-type (I/O) Serial Transmission System VV5QC S Kit (Serial transmission kit: EX600) Power supply with M connector 6.5 5.5 Digital input unit Input connector Digital output unit Output connector 7 m + 66 Communication connector SI unit L L (n ) x 5 Indicator light Manual override 5 65.5 6.5 IP67 compliant 7.5 (6) 6 0 6 7 m 7 R.5 6 Marker groove Power connector Valve plate FE terminal Connector for handheld terminal x M Mounting hole End plate / [ (R) port] /: /" Female thread (Rc, G, NPT/NPTF) / [ (P) port] /: /" Female thread (Rc, G, NPT/NPTF) D-side Stations 5 6 7 n U-side 56.6 5.7.7.5 7 77. 5.5..5 / (External pilot port) /: /" Female thread (Rc, G, NPT/NPTF) / (Pilot EXH port) /: /" Female thread (Rc, G, NPT/NPTF) 0.6.5 7.7 5 65.5.5 (6.5) / / C C C [(), () port] /: /" Female thread (Rc, G, NPT/NPTF) /: /" Female thread (Rc, G, NPT/NPTF) C: ø One-touch fitting C: ø One-touch fitting C: ø One-touch fitting Formulas L = 5n + 6 L = 5n + L dimension: Without I/O unit For additional I/O unit, add 7 mm. m: I/O unit stations Dimensions L L L n 0 56 n: Stations (Maximum 6 stations) 5 6 7 5 6 06 5 0 56 06 5 56 0 5 06 56 50 5 506 55 5 6

series VV5QC S Kit (Serial transmission kit: EX500) L L L n SI unit M -pin socket 60.7 5.7 M -pin plug.5 PWR COM EX500 D-side x Rc / External pilot port 0 ase Mounted Stations L L Manual Indicator light override x Rc/ Pilot EXH port Formulas: L = 5n + 6, L = 5n + 5 n: Stations (Maximum 6 stations) 5 6 7 5 6 77 56 0 7 06 5 77 56 0 7 06 5 77 56 0 7 06 5 77 56 50 57 506 55 P=5 5 6 7 n x Rc /, /, C, C, C Rc /:/" Female thread Rc /: /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit Series C000 S C000 kit (Serial transmission kit): For EX500 Gateway-type Serial Transmission System IP67 compliant.5 65.5 n 7.7 P=5 65.5 U-side (6.5) 0.5.5 (6.5) 6 x Rc / (R) port x Rc / (P) port.5 77.5 5.5 SJ J VF VP S0700 5 C C Z VFS VFR 7 7

Series C000 C000 IP0 compliant S kit (Serial transmission): For EX60 Integrated-type (I/O) Serial Transmission System IP67 compliant VV5QC S Kit (Serial transmission kit: EX60).5 L L (n ) x 5 (6.5) Indicator light Manual override 5 65.5 76.7.7 5.7.5 77.5 5.5 6 SI unit D-side Stations 5 6 7 n U-side <Communication connector D-sub> x Rc/ (R) port x Rc/ (P) port 76.7.7 5.7 x Rc/ External pilot port x Rc/ Pilot EXH port.5.5 0.5 (6.5) 7 n x Rc/, /, C, C, C (), () port.7 5 65.5 L L L n 77 56 0 7 06 5 5 77 6 56 0 7 7 06 5 77 56 0 7 06 5 n: Stations (Maximum 6 stations) 77 56 50 5 57 6 506 55

ase Mounted Plug-in Unit Series C000 S C000 kit (Serial transmission kit): For EX50 Integrated-type (I/O) Serial Transmission System IP67 compliant VV5QC S Kit (Serial transmission kit: EX50) 60.7 5.5 66.5 Input block x M 5.7 x M x M 0 6 SI unit M x Rc / External pilot port 0 US PWR Indicator light x Rc / Pilot EXH port L n x C, C6, C C: ø One-touch fitting C6: ø6 One-touch fitting C: ø One-touch fitting C: ø One-touch fitting C: ø One-touch fitting (), () port L P=5.5 65.5 D-side Stations 5 6 7 n U-side 7.7 P=5 65.5 (6.5) Manual override 6 x Rc / (R) port x Rc / (P) port 0.5.5 (6.5).5 77.5 5.5 SJ J VF VP S0700 5 C C Z VFS VFR 7 Formulas: L = 5n + 6, L = 5n + 05 (For one input block. dd mm for each additional input block.) n: Stations (Maximum 6 stations) L n 5 6 7 5 6 L L 0 56 55 0 06 05 0 56 55 0 06 05 0 56 55 0 06 505 50 56 555 50 506 605

Series C000 S C000 kit (Serial transmission kit): For EX6 Integrated-type (Output) Serial Transmission System VV5QC S Kit (Serial transmission kit: EX6) IP67 compliant x M5 Mounting hole 7.5 7 6 L Indicator light Manual override L P=5 65.5 6.5 R.5 6.5 0 R.5 55.5 SI unit Please use drip proof plug assembly (XT0-0) with unused conduit port (G/). x G / Conduit port 0.7.6 55.5.7 D-side Stations 5 6 7 n U-side x Rc / (R) port x Rc / (P) port 0.5.5 7 77.5 5.5 5.7.5 x Rc / External pilot port x Rc / Pilot EXH port n x Rc /, /, C, C, C Rc /: /" Female thread Rc /: /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port.5.5 7.7 (6.5) L L L n Formulas: L = 5n + 6, L = 5n + n: Stations (Maximum 6 stations) 5 6 7 5 6 56 06 7 67 56 06 7 67 7 56 06 56 67 57 5 506 567 5 0

SJ J VF VP S0700 5 C C Z VFS VFR 7

Series C000 F C000 kit (D-sub connector kit) IP0 compliant Using our D-sub connector for electrical connections greatly reduces labor, while it also minimizes wiring and saves space. We use a D-sub connector (5P) that conforms to MIL standards and is therefore widely compatible with many standard commercial models. Top or side entry for the connector can be changed freely, allowing for changes even after mounting, to meet any changing needs for space. Electrical Wiring Specifications D-sub connector 5 6 7 0 5 5 6 7 Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station (For 5P) Standard wiring s the standard electrical wiring specification used is for stations or less, double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications (options) below. Lead wire colors for D-sub connector assemblies Connector terminal no. 05 (XT0-DS5-00 ) 5 6 7 0 5 SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. COM. 5 6 7 Terminal no. 5 6 7 5 6 7 0 5 Lead wire color lack Yellow rown Pink lue Orange Purple Yellow Gray Pink Orange lue Purple rown Gray Pink Gray lack Yellow Orange Dot marking lack lack lack lack lack Special Wiring Specifications (Options) 050 Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed. Cable ssembly XT0-DS5-05 00 050 D-sub connector cable assemblies can be ordered with manifolds. Refer to manifold ordering. Lead wire colors for D-sub connector cable assembly terminal numbers L 6 (.).5 m m 5 m 05 55 5 7.0 XT0-DS5-05 XT0-DS5-00 XT0-DS5-050 Cable 0. mm x 5 core O.D. ø. pprox. ø Seal (length indication) Molded cover x M.6 x 0.5 Connector D-5SF-N manufactured by Japan viation Electronics Industry, Ltd. Socket side Terminal no. D-sub connector cable assemblies Cable length (L) Part no. Note Cable 0. mm x 5 cores When using a standard commercial connector, use a type 5P female connector conforming to MIL-C-0. Cannot be used for transfer wiring. Lengths other than the above is also available. Please contact for details. Terminal no. 5 6 7 5 6 7 0 5 Lead wire color lack rown Orange Yellow Pink lue Purple Gray Yellow Orange Yellow Pink lue Purple Gray Orange rown Pink Gray lack Dot marking lack lack lack lack lack Electrical characteristics Some connector manufacturers: Item Characteristic Fujitsu, Ltd. Conductor resistance 65 or less Japan viation Electronics Industry, Ltd. Ω/km, 0 C J.S.T. Mfg. Co., Ltd. Voltage limit HIROSE ELECTRIC CO., LTD. 00 V, minute, C Insulation resistance 5 or more MΩ/km, 0 C Note) The minimum bending radius for D-sub connector cables is 0 mm. COM

F C000 kit (D-sub connector kit) VV5QC pplicable connector: D-sub connector (5P) (Conforms to MIL-C-0) 60.7 5.7 D-sub connector cable assembly (5P) XT0-DS5-05:.5 m XT0-DS5-00: m XT0-DS5-050: 5 m Formulas: L = 5n + 6, L = 5n +.5 n: Stations (Maximum 6 stations) L n 5 6 7 5 6 L L 6.5 56.5.5 06.5 6.5 56.5.5 06.5 6.5 56.5.5 06.5 6.5 56.5 5.5 506 5.5 7.5 R0(Min. bending inner radius) IP0 compliant 67 ase Mounted 7 x Rc / Pilot EXH port x Rc / External pilot port Indicator light n x Rc /, /, C, C, C Rc /: /" Female threa Rc /: /" Female threa C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit L L P=5 Manual release for switching connector direction 65.5 D-side Stations 5 6 7 n U-side Series C000 (6.5) 6.5 (6.5) 7.7 P=5 65.5.5 Manual override x Rc / (R) port x Rc / (P) port 0.5.5 77.5 5.5 SJ J VF VP S0700 5 C C Z VFS VFR 7

Series C000 P C000 kit (Flat ribbon cable kit) Using our flat ribbon cable for electrical connections greatly reduces labour, while it also minimizes wiring and saves space. We use flat ribbon cables whose connectors (6P and 0P) conform to MIL standards, and are therefore widely compatible with many standard commercial models. Top or side entry for the connector can be changed freely, allowing for changes even after mounting, to meet any changing needs for space. Electrical Wiring Specifications Flat ribbon cable connector 6 0 6 6 5 7 5 7 5 Connector terminal number Double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications (options) below. Triangle mark indicator position IP0 compliant Cable ssembly 0 XT0-FC - 6 Type 6P flat ribbon cable connector assemblies can be ordered with manifolds. Refer to manifold ordering. 0 (0P) 7.5 (6P) 6 6 5 Terminal no. WG Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station <6P> SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. Terminal no. 5 6 7 5 6 7 0 Station Station Station Station Station 5 Station 6 Station 7 Station Station <0P> Terminal no. SOL. SOL. SOL. 5 6 SOL. 7 SOL. SOL. SOL. SOL. 5 6 SOL. 7 COM. COM. 0 Cable length (L).5 m m 5 m (5.6) Flat ribbon cable connector assemblies 6P XT0-FC6- XT0-FC6- XT0-FC6- L Part no. 0P XT0-FC0- XT0-FC0- XT0-FC0- When using a standard commercial connector, use a type 6P connector conforming to MIL-C-50 or a type 0P with strain relief. Cannot be used for transfer wiring. Lengths other than the above is also available. Please contact for details. Connector Manufacturers Example: Hirose Electric CO., Ltd. Sumitomo/M Limited Fujitsu, Ltd. Japan viation Electronics Industry, Ltd. J.S.T. Mfg. Co., Ltd. Oki Electric Cable Co., Ltd. COM. COM. 5 6 COM Special Wiring Specifications (Option) COM 6 5 COM 0 0 7 7 6 5 6 5 7 7 6 5 6 5 (For 6P) (For 0P) COM Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed.

P C000 kit (Flat ribbon cable kit) VV5QC pplicable connector: Flat ribbon cable connector (6P) (Conforms to MIL-C-50) Flat ribbon cable connector assembly (6P) XT0-FC6-:.5 m XT0-FC6-: m XT0-FC6-: 5 m 60.7 5.7 7.5 x Rc / External pilot port 67 IP0 compliant Formulas: L = 5n + 6, L = 5n +.5 n: Stations (Maximum 6 stations) L n 5 6 7 5 6 L L 6.5 56.5.5 06.5 6.5 56.5.5 06.5 6.5 56.5.5 06.5 6.5 56.5 5.5 506 5.5 7 ase Mounted Indicator light x Rc / Pilot EXH port n x Rc /, /, C, C, C Rc /: /" Female thread Rc /: /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit L L Manual release for switching connector direction P=5.5 65.5 D-side Stations 5 6 7 n U-side P=5 65.5 Series C000 7.7 (6.5) 6 x Rc / (R) port x Rc / (P) port 0.5.5.5 (6.5) Manual override 77.5 5.5 SJ J VF VP S0700 5 C C Z VFS VFR 7 5

Series C000 T C000 kit (Terminal block box kit) IP67 compliant This kit has a small terminal block inside a junction box. The provision of a G / electrical entry allows connection of conduit fittings. Terminal lock Connection Step. How to remove terminal block cover Loosen the mounting screws (M) and remove the terminal block cover. Mounting screw (M) Terminal block cover Step. The diagram below shows the terminal block wiring. ll stations are provided with double wiring regardless of the valves which are mounted. Connect each wire to the power supply side, according to the markings provided inside the terminal block. M screw Gasket Electrical entry x G / 6 mm Step. How to replace the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly. Proper tightening torque (N m) 0.7 to. pplicable crimped terminal:.5-s,.5y-,.5y-n,.5y-.5 Name plate: V5000-N-T Drip proof plug assembly (for G /): XT0-06 Electrical Wiring Specifications (Conforms to IP67) 5 5 6 6 7 7 COM 5 6 7 COM The internal wiring is double (connected to SOL. and SOL. ) for all stations regardless of the type of valve or options. Mixed single and double wiring are available as options. 5 6 7 Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Standard wiring Terminal no. SOL. SOL. SOL. SOL. SOL. 5 5 SOL. 6 6 SOL. 7 7 SOL. SOL. SOL. COM. COM Special Wiring Specifications (Option) Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed 0.. How to order Indicate option symbol "-K" in the manifold part number and be sure to specify station positions for single or double wiring on the manifold specification sheet.. Wiring specifications Connector terminal numbers are connected from solenoid station on the side in the order indicated by the arrows without skipping any terminal numbers. 5 5 6 6 7 7 COM 5 6 7 COM 5 6 7 6

VV5QC ase Mounted T C000 kit (Terminal block box kit) IP67 compliant Plug-in Unit Series C000 77.5 0.5 Mounting hole for x M5 x G / Conduit port 5.5.7 5.7 L 7.5 L 6.5 7 Indicator light P=5 65.5 Manual override D-side x Rc / External pilot port x Rc / Pilot EXH port n x Rc /, /, C, C, C Rc / : /" Female thread Rc / : /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Stations 5 6 7.5 n.5 7.7 U-side 0.5 (6.5) 6 x Rc / (R) port x Rc / (P) port.5 77.5 5.5 SJ J VF VP S0700 5 C C Z VFS VFR 7 L L L n Formulas: L = 5n + 6, L = 5n + n: Stations (Maximum 6 stations) 5 6 7 5 6 56 06 7 67 56 7 67 06 56 7 06 67 57 56 506 5 567 5 7

Series C000 L C000 kit (Lead wire kit) IP67 compliant Direct electrical entry type. IP67 enclosure is available with use of cables with sheath and waterproof connectors. Electrical Wiring Specifications Lead wire specifications Lead wire 0. mm x 5 core Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station Sheath Colour: Urban white SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. COM. s the standard electrical wiring specification used is for stations or less, double wiring (connected to SOL. and SOL. ) is used for the internal wiring of each station regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications (options) below. Terminal no. Lead wire colour Dot marking lack Yellow lack rown 5 Pink lack 6 lue Orange 7 Purple 5 Yellow Grey 6 Pink Orange lack 7 lue 0 Purple rown Grey lack Pink lack Grey lack Yellow 5 Orange Lead wire length VV5QC 0 C LD 0 Electrical characteristics Item Characteristic Conductor resistance 65 or less Ω/km, 0 C Withstand pressure 00 V, minute, C Insulation resistance 5 or more MΩ/km, 0 C Note) Cannot be used for transfer wiring. The minimum bending radius for cables is 0 mm. Lead wire length 0 0.6 m.5 m.0 m Special Wiring Specifications (Option) Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed.

L C000 kit (Lead wire kit) IP67 compliant VV5QC 60.7 7.5 x Rc/ External pilot port Lead wire length 0.6 m,.5 m, m 5.7 L L Formulas: L = 5n + 6, L = 5n + 60.5 n: Stations (Maximum 6 stations) L n 5 6 7 5 6 L L 5.5 56.5 5.5 06 60.5 5.5 56.5 5.5 06 60.5 5.5 56.5 5.5 06 60.5 5.5 56 5.5 55.5 506 560.5 ase Mounted Indicator light P=5.5 65.5.7 P=5 65.5.5 7 (6.5) D-side Stations 5 6 7 n U-side x Rc / (R) port x Rc / (P) port x Rc/ Pilot EXH port n x Rc /, /, C, C, C Rc / : /" Female thread Rc / : /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit Series C000 Manual override 0.5 (6.5).5 6 77.5 5.5 SJ J VF VP S0700 5 C C Z VFS VFR 7

Series C000 M C000 kit (Circular connector kit) IP67 compliant Use of circular connectors helps streamline wiring procedure to save labor. IP67 enclosure is available with use of waterproof multiple connectors. Electrical Wiring Specifications Multiple connector!5 q!!6 w! @!7 e! @! @!0 @ @5 @6! r! t @0 y o i u Station Station Station Station Station 5 Station 6 Station 7 Station Station Station Station Station Double wiring(connected to SOL. and ) is used for the internal wiring of each staion regardless of valve and option types. Mixed single and double wiring are available as options. Refer to special wiring specifications(options) below. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. SOL. COM. COM. Terminal no. 5 6 7 5 6 7 0 5 6 Special Wiring Specifications (Option) Mixed single and double wiring are available as an option. The maximum number of manifold stations is determined by the number of solenoids. Count one point for a single solenoid type and two points for a double solenoid type. The total number of solenoids (points) must not exceed. Cable ssembly XT0-MC6-05 00 050 Type 6P circular connector cable assemblies can be ordered with manifolds. Refer to manifolds ordering. L 60 5 6 7 assemblies Cable length (L).5 m m 5 m 05 ø0 7 6 0 5 6 5 Cable 0.mm x 5C O.D. ø. pprox. ø Seal (Length) Circular connector cable Plug ssembly no. 6P XT0-MC6-05 XT0-MC6-00 XT0-MC6-050 Cannot be used for transfer wiring. Lengths other than the above is also available. Please contact for details. Terminal no. M7 female thread Lead wire colors for circular connector cable assembly terminal numbers Terminal no. 5 6 7 5 6 7 0 5 6 Lead wire color lack rown Orange Yellow Pink lue Purple Gray Yellow Orange Yellow Pink lue Purple Gray Orange rown Pink Gray lack Dot marking lack lack lack lack lack Electric characteristics Item Property Conductor resistance 65 or less Ω/km, 0 C Voltage limit 00 V, minute, C Insulation resistance 5 or more MΩ/km, 0 C Note) The minimum bending radius of the multiple connector cable is 0 mm.

M C000 kit (Circular connector kit) IP67 compliant VV5QC L L L 7.5 Circular connector cable assembly XT0-MC6-05:.5 m XT0-MC6-00: m XT0-MC6-050: 5 m M7 male screw 60.7 5.7 x Rc / External pilot port ase Mounted L L (6.5) Indicator light x Rc / Pilot EXH port P=5 Stations 5 6 7 Circular connectors (6 pins) C made by CONINVERS Formulas: L = 5n + 6, L = 5n + 50.5 n: Stations (Maximum 6 stations) n 5 6 7 5 6 56 06 56 06 56 06 56 506 5.5.5 5.5 60.5 5.5.5 5.5 60.5 5.5.5 5.5 60.5 5.5 5.5 55.5 560.5 D-side n x Rc /, /, C, C, C Rc / : /" Female thread Rc / : /" Female thread C : ø One-touch fitting C : ø One-touch fitting C : ø One-touch fitting (), () port Plug-in Unit.5 65.5 n.7 P=5 65.5 Series C000 7 U-side x Rc / (R) port x Rc / (P) port 0.5.5 (6.5) Manual override.5 6 77.5 5.5 SJ J VF VP S0700 5 C C Z VFS VFR 7

C000 Series Exploded View of Manifold Housing assembly and SI unit D-side end plate assembly Manifold block assembly U-side end plate assembly EX600 w r q e EX60 y Corresponding kit S(EX600, EX50, EX6).F.P.T @0!7 EX50 S Kit (Serial) EX500 t u i o! EX6!0! (Flat ribbon cable) F Kit P Kit!!!!7!! (Terminal block) T Kit S Kit (Serial) (D-sub connector)! Corresponding kit L Kit (Lead wire) S(EX500, EX60).L.M!5 Note) There are two kinds of manifold blocks available, stations integrated type and station type. stations integrated type is used for even stations while stations integrated type and station type are combined for odd stations. D side U side M Kit (Multiple connector) 5 6 5 stations (Odd number) stations stations station 6 stations (Even number) stations stations stations!6

ase Mounted Plug-in Unit Series C000 Manifold ssembly Part No. Housing ssembly and SI Unit/Input lock No. SI unit Digital Input Unit Description Digital Output Unit Digital Input/Output End plate Valve Plate 5 SI unit 6 nalog Input Unit nalog Output Unit nalog Input/Output Unit SI unit Part no. EX600-SDN EX600-SDN EX600-SMJ EX600-SMJ EX600-SPR EX600-SPR EX600-SEN EX600-SEN EX600-SEC EX600-SEC EX600-DXN EX600-DXP EX600-DXNC EX600-DXNC EX600-DXPC EX600-DXPC EX600-DXND EX600-DXPD EX600-DXNE EX600-DXPE EX600-DXNF EX600-DXPF EX600-DYN EX600-DYP EX600-DYNE EX600-DYPE EX600-DYNF EX600-DYPF EX600-DMNE EX600-DMPE EX600-DMNF EX600-DMPF EX600-X EX600-Y EX600-M EX600-ED EX600-ED- EX600-ED EX600-ED- EX600-ZMV EX500-Q00 EX500-Q EX60-SDN EX60-SDN EX60-SDN EX60-SDN EX60-SRP EX60-SRP EX60-SRP EX60-SRP EX60-SRP5 EX60-SRP6 EX60-SRP7 EX60-SRP EX60-SMJ EX60-SMJ EX60-SMJ EX60-SMJ EX60-SEC EX60-SEC EX60-SEC EX60-SEC EX60-SPN EX60-SPN EX60-SPN EX60-SPN EX60-SEN EX60-SEN EX60-SEN EX60-SEN Note DeviceNet PNP (Negative common) DeviceNet NPN (Positive common) CC-Link PNP (Negative common) CC-Link NPN (Positive common) PROFIUS DP (Negative common) PROFIUS DP (Positive common) EtherNet/IP (Negative common) EtherNet/IP (Positive common) EtherCT PNP (Negative common) EtherCT NPN (Positive common) NPN input, M connector, 5 pins ( pcs.), inputs PNP input, M connector, 5 pins ( pcs.), inputs NPN input, M connector, pins ( pcs.), inputs NPN input, M connector, pins ( pcs.), inputs, with open circuit detection PNP input, M connector, pins ( pcs.), inputs PNP input, M connector, pins ( pcs.), inputs, with open circuit detection NPN input, M connector, 5 pins ( pcs.), 6 inputs PNP input, M connector, 5 pins ( pcs.), 6 inputs NPN input, D-sub connector, 5 pins, 6 inputs PNP input, D-sub connector, 5 pins, 6 inputs NPN input, Spring type terminal box, pins, 6 inputs PNP input, Spring type terminal box, pins, 6 inputs NPN output, M connector, 5 pins ( pcs.), outputs PNP output, M connector, 5 pins ( pcs.), outputs NPN output, D-sub connector, 5 pins, 6 outputs PNP output, D-sub connector, 5 pins, 6 outputs NPN output, Spring type terminal box, pins, 6 outputs NPN output, Spring type terminal box, pins, 6 outputs NPN input/output, D-sub connector, 5 pins, inputs/outputs PNP input/output, D-sub connector, 5 pins, inputs/outputs NPN input/output, Spring type terminal box, pins, inputs/outputs PNP input/output, Spring type terminal box, pins, inputs/outputs M connector, 5 pins ( pcs.), -channel input M connector, 5 pins ( pcs.), -channel output M connector, 5 pins ( pcs.), -channel inputs/outputs M connector, 5 pins, Max. supply current M connector, 5 pins, Max. supply current, with DIN rail mounting bracket 7/ inch connector, 5 pins, Max. supply current 7/ inch connector, 5 pins, Max. supply current, with DIN rail mounting bracket Enclosed parts: round head screws (M x 6) pcs., round head screws (M x ) pcs. EX500 NPN (Positive common) EX500 PNP (Negative common) DeviceNet, M connector, outputs PNP (Negative common) DeviceNet, M connector, outputs NPN (Positive common) DeviceNet, M connector, 6 outputs PNP (Negative common) DeviceNet, M connector, 6 outputs NPN (Positive common) PROFIUS DP, M connector, outputs PNP (Negative common) PROFIUS DP, M connector, outputs NPN (Positive common) PROFIUS DP, M connector, 6 outputs PNP (Negative common) PROFIUS DP, M connector, 6 outputs NPN (Positive common) PROFIUS DP, D-sub connector, outputs PNP (Negative common) PROFIUS DP, D-sub connector, outputs NPN (Positive common) PROFIUS DP, D-sub connector, 6 outputs PNP (Negative common) PROFIUS DP, D-sub connector, 6 outputs NPN (Positive common) CC-Link, M connector, outputs PNP (Negative common) CC-Link, M connector, outputs NPN (Positive common) CC-Link, M connector, 6 outputs PNP (Negative common) CC-Link, M connector, 6 outputs NPN (Positive common) EtherCT, M connector, outputs PNP (Negative common) EtherCT, M connector, outputs NPN (Positive common) EtherCT, M connector, 6 outputs PNP (Negative common) EtherCT, M connector, 6 outputs NPN (Positive common) PROFINET, M connector, outputs PNP (Negative common) PROFINET, M connector, outputs NPN (Positive common) PROFINET, M connector, 6 outputs PNP (Negative common) PROFINET, M connector, 6 outputs NPN (Positive common) EtherNet/IP, outputs PNP (Negative common) EtherNet/IP, outputs NPN (Positive common) EtherNet/IP, 6 outputs PNP (Negative common) EtherNet/IP, 6 outputs NPN (Positive common) SJ J VF VP S0700 5 C C Z VFS VFR 7

Series C000 Manifold ssembly Part No. Housing ssembly and SI Unit/Input lock No. Description Part no. EX50-SPR EX50-SMJ EX50-SS EX50-SS5 EX50-SS7 7 SI Unit EX50-SS EX50-SC EX50-SDN EX50-SEN EX50-IE Input block EX50-IE EX50-IE EX50-E End plate assembly EX50-E SI unit EX6D-SMJ Terminal plate VC00-7- D-sub connector housing assembly VC00-F5- Flat ribbon cable housing assembly VC00-P6- VC00-P0- Terminal block box housing assembly VC00-T0- VC00-L5-0- 5 Lead wire housing assembly VC00-L5-- VC00-L5-- 6 Multiple connector housing assembly VC00-M6- Note PROFIUS DP PNP (Negative common) CC-LinkNPN (Positive common) S-Interface, in/ out, slave modes, power supply systems PNP (Negative common) S-Interface, in/ out, slave modes, power supply systems PNP (Negative common) S-Interface, in/ out, slave modes, power supply system PNP (Negative common) S-Interface, in/ out, slave modes, power supply system PNP (Negative common) CNopen PNP (Negative common) DeviceNet PNP (Negative common) EtherNet/IP PNP (Negative common) M, inputs M, inputs M, inputs Direct mounting DIN rail mounting CC-Link NPN (Positive common) For EX6 SI unit mounting F kit, 5 pins P kit, 6 pins P kit, 0 pins T kit L kit with 0.6 m lead wire L kit with.5 m lead wire L kit with.0 m lead wire M kit 6 pins

ase Mounted Plug-in Unit Series C000 Manifold ssembly Part No. D-side end plate assembly!7d-side end plate assembly part no. VC000- Thread type Nil F T Kit type F, P, T, S (EX6, EX50, EX600) kit L, M, S (EX60, EX500) kit U-side end plate assembly @0U-side end plate assembly part no. VC000--- Thread type Nil F T Rc G NPT/NPTF Rc G NPT/NPTF Manifold block assembly!manifold block assembly part no. VC000- D C6 C Type For station For stations Note ) Note ) Tie-rods ( pcs.) for additional stations included. Note ) ottom ported type is available only for station. Wiring Specifications D Double wiring S Single wiring Replacement parts Pilot valve assembly C000 ZP--!Tie-rod assembly part no. ( units) C000 VC000-TR- Note ) Please order when reducing the number of manifold stations. When increasing the number of stations, additional orders are not required since they are included in the manifold block assembly. Note ) Number of stations, 0 to 6 Thread type (Thread port only) Nil Rc F G T NPT/NPTF Port size Symbol Port size C For ø C For ø C For ø N7 For ø/" N For ø5/6" N For ø/" 0 Rc /" 0 Rc /" Rc /" bottom ported : side (Indicator light: Orange) : side (Indicator light: Green) E: Without indicator light (In common for side and side) 5: VDC 6: VDC Nil: standard ( W) Y : Low wattage (0.5 W) SJ J VF VP S0700 5 C C Z VFS VFR 7 5

Series C000 Specific Product Precautions e sure to read this before handling. Refer to front matter 5 for Safety Instructions and pages to for //5 Port Solenoid Valve Precautions. Warning Since connected equipment will operate when the manual override is activated, confirm that conditions are safe prior to activation. Push type (tool required) is standard, and locking type (tool required) is optional. C000 Push type (Tool required) ore ø5 Manual Override Push down the manual override button with a small screwdriver, etc., until it stops. The manual override will return when released. Replacing One-touch Fittings Cylinder port fittings are available in cassette type and can be replaced easily. Fittings are secured with a retaining clip that is inserted from the top side of the valve. fter removing the valve,remove the clip with a flat head screw driver to replace the fittings. To mount a fitting, insert the fitting assembly until it stops and reinsert the retaining clip to its designated position. Clip Locking type (Tool required) <Option> ore ø5 Push down the manual override button with a small flat head screwdriver or with your finger until it stops, and turn it clockwise 0 to lock it. Turn it counterclockwise to release it. Fitting ssembly Valve Mounting Proper tightening torque (N m) 0. to. PUSH TURN LOCK fter confirming that the gasket is installed correctly, securely tighten the mounting screws according to the tightening torque shown below. Mounting screw (M) pplicable tube O.D. ø ø ø ø/" ø5/6" ø/" Fitting assembly part no. C000 V000-50-C V000-50-C V000-50-C V000-50-N7 V000-50-N V000-50-N Installation and Removal of Light Cover Installation/Removal of light cover Removal Open the cover by inserting a small flat head screwdriver into the slot on the side of the pilot assembly (see drawing below), lift the cover out about mm and then pull off. If it is pulled off at an angle, the pilot valve may be damaged or the protective O-ring may be scratched. Installation Place the cover straight over the pilot O-ring assenmbly so that the pilot valve is not Light cover touched,and push it until the cover hook locks without twisting the protective O-ring. (When pushed in, the hook opens and locks automatically.) 6