Centrifugal Constant Pressure Control

Similar documents
Centrifugal Constant Pressure Control

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

Commander Pro Variable Speed Controller System Instructions

Commander Pro Variable Speed Controller System Instructions

Electronic Products ELECTRONIC MAINTENANCE

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

STAR STOP SHALLOW WELL JET PUMP

SHALLOW WELL JET PUMP

END SUCTION CENTRIFUGAL PUMPS

2 Wire Plus Ground 3 Wire Plus Ground IL0655

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PRE-PLUMBED SEWAGE SYSTEM

GARDEN HOSE UTILITY PUMP

STEP-BY-STEP INSTALLATION GUIDE

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

AUTOMATIC SUBMERSIBLE UTILITY PUMP

LAWN SPRINKLER, IRRIGATION PUMP

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Owner's/Installation Manual

M-3025CB-AV Fuel Pump

END SUCTION CENTRIFUGAL PUMPS

FHOTON Drive. Installation Guide

COPYRIGHT INFORMATION

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

HALLMARK INDUSTRIES INC

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

CALTRAP INSTALLATION AND OPERATIONS MANUAL

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

High Frequency SineWave Guardian TM

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

SUBMERSIBLE SUMP PUMPS

Material required for drilled well application (indoor use only)

Installation & Operating Manual

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

SUBMERSIBLE SUMP PUMPS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Installation and Operating Instructions

Technical Manual. DLM Module. This manual should remain with the unit.

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

MODEL SS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

PL Submersible, Semi-Vortex, Water Feature Pump

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

AeroVironment Universal Solar Pump Controllers

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Submersible Effluent Pump

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

PI1500X Power Inverter User s Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Installation and Operating Instructions

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

ProFlo FatBoy

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

Owners Manual: - Pumps

USER MANUAL MODEL: 3SPC3.3/106-D72/1100

MODEL 233P/111P/233P-1.5

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

6L Oil-less Air Compressor 53103

AIR COMPRESSOR IDENTIFICATION

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Model &

SS/SSH Submersible Pump. Owner s Manual

Installation & Operating Manual

The Da-Lite Difference.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

AIR COMPRESSOR IDENTIFICATION

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

SOLAR SUBMERSIBLE PUMP CONTROLLER. SubDrive Solar. Installation Manual

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

ADVANCED PID TROUBLESHOOTING

Model (Circuit Tester) Model (GFCI Tester)

The POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.

Pneumatic Isolation Module

Inverter User Manual

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

ESE Series Cast Iron Sewage Pumps

Transcription:

Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage Retain instructions for future reference. FW1135 0711 Supersedes 1008 Centrifugal Constant Control Models AD155145, AD220210, AD280280 Descriptions and Features The F&W Artesian Drive is a dependable water system Variable Frequency Drive (VFD) that uses custom programming to enhance the performance of standard centrifugal pumps. When applied correctly to three phase motor driven pumps, the Artesian Drive eliminates pressure cycling associated with conventional pressure switch controlled water pumping systems and provides a constant output pressure. Key features of the Artesian Drive include: Constant water pressure with a wide range of settings (30-80 psi) (Note: The maximum obtainable system pressure is limited by the performance of the pump installed) Smaller pressure tank can be used Fits the pump to the application pump speed is controlled to provide the optimum performance without overloading the motor Flexibility you can use this unit with standard off-theshelf pumps and 3-Phase motors No in-rush (power-on transient) current Low motor start-up current (soft-starting) Active Power Factor Correction minimizes input RMS current Protection features -- Dry run conditions using intelligent load monitoring (see Page 8) -- Bound pump with auto-reversing torque -- High voltage / lightning surge -- Low line voltage (For AD155145, AD220210 & AD280280 drives, 3-Phase supply power needs to be available.) -- Short circuit Unpacking When unpacking the unit, inspect carefully for any damage that may have occurred during transit. Included Items: A. Controller Unit F. Drive Accessory Kit B. Strain Relief Fitting G. Memory Stick & Retainer C. and Boot H. Warranty Card D. Adjustment Tools I. Installation Guide E. Cable J. Installation Manual 1 (022693 / FW1135) A Figure 1 G B D C E General Safety Information Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. Replace missing or damaged safety labels. This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump or in the manual, look for one of the following signal words and be alert to the potential for personal injury or property damage. Warns of hazards that WILL cause serious personal injury, death or major property damage if ignored. Warns of hazards that CAN cause serious personal injury or death, if ignored. Warns of hazards that MAY cause minor personal injury, product or property damage if ignored. IMPORTANT: Indicates factors concerned with operation, installation, assembly or maintenance which could result in damage to the machine or equipment if ignored. NOTE: Indicates special instructions which are important but are not related to hazards. Read these warnings and instructions carefully. Failure to follow could result in serious bodily injury and/or property damage. F J IL0755 I H 022693

Capacitors inside the Artesian Drive controller can still hold a lethal voltage even after power has been removed. Allow 10 minutes for dangerous internal voltage to discharge before opening the unit. Do not use power factor correction capacitors with the Artesian Drive. Damage will result to both motor and drive. Electrical installations shall be in accordance with National Electric Code (NEC) and all applicable local codes and ordinances. A licensed electrician should perform installation. Be sure system is connected to a circuit equipped with a fuse or circuit breaker of the correct rating. This unit not tested for use in swimming pool areas. How it Works The F&W Artesian Drive is designed to be part of a system that consists of only four major components: A. Standard Pump and Three Phase. B. Artesian Drive Controller. C. Small Tank (for tank size, see Table 2). D. (provided). Relief Valve Tank Inlet Pump Outlet Leads Always disconnect power source before performing any work on or near the controller, motor or its connected load. If the power disconnect point is out-of-sight, lock it in the open position and/or tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock or bodily injury. Power Supply from Circuit Breaker Power to Leads Constant Diagram IL0759 DO NOT handle pump with wet hands or when standing in water as fatal electrical shock could occur. Disconnect main power supply before handling system for any reason. Protect the power cable from coming in contact with sharp objects, oil, grease, hot surfaces or chemicals. DO NOT kink the power cable. If damaged replace immediately. NEVER leave the control box, fused disconnect switch, or covers open (either partially or completely) when not being worked on by a competent electrician or repairman. Always use caution when operating electrical controls in damp areas. If possible, avoid all contact with electrical equipment during thunderstorms or extreme damp conditions. Figure 2a - Constant Diagram for booster pumps Power Supply from Circuit Breaker Outlet Inlet Leads Power to Relief Valve Pump Tank Leads IL1200 Figure 2b - Constant Diagram for centrifugal pumps Install all electrical equipment in protected area to prevent mechanical damage which could produce serious electrical shock and/ or equipment failure. DO NOT use this system to pump flammable liquids such as gasoline, fuel oil, kerosene, etc. Failure to follow the above warning could result in property damage and/or personal injury. This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Do not pump water above 140 degrees Fahrenheit. 2 (022693 / FW1135) Constant The F&W Artesian Drive provides consistent pressure regulation using custom programming to run a standard motor and pump according to the pressure demands indicated by a heavy duty pressure switch. By adjusting the motor/pump speed, the Artesian Drive can deliver consistent pressure dependably, even as water demand changes. For example, a small demand on the system, such as a kitchen faucet, results in the motor/pump running at a relatively low speed. As greater demands are placed on the water system, such as opening additional faucets or using appliances, the motor/ pump speed increases accordingly to maintain the desired system pressure. Soft Start Whenever the Artesian Drive detects that water is being used, the controller always ramps up the motor speed at the

same time as gradually increasing voltage, resulting in a cooler running motor and lower in-rush current compared to a motor being used on conventional water systems. If the water demand is very low, the system may cycle on and off at very low speeds, but due to the drive s soft-start feature and pressure switch s dependable design, this will not harm the motor or the pressure sensor. System Diagnostics In addition to regulating system pressure and accurately controlling motor operation, the Artesian Drive continuously scans the system and can detect a variety of abnormal conditions. If there is elevated risk of damage to a part of the system, the drive will protect the system and display a code for the fault. If possible, the drive will try to restart itself when the fault condition passes. Pump Sizing Artesian Drive (Centrifugal) The Artesian Drive is configured at the factory for use with standard 3-phase motors and pumps. NOTE: The Artesian Drives are factory programmed to F&W pumps to provide optimum performance and motor protection. The Artesian Drive can be used with other pumps, but the maximum motor amperage needs to be compared to the factory programmed current value (refer to the Specifications section under the appropriate model). If the maximum motor current varies more than 5% from the programmed value, the motor current value in the drive needs to be changed for motor protection and optimum performance. For details on how to change this value in the drive, please contact Technical Support at 1-800-345-9422. The rated current must be set correctly to avoid a risk of fire in the event of a motor overload. Drive Configuration When sized correctly, the Artesian Drive systems are ready to go right out of the box and need no configuration. Under certain circumstances there are several programming parameters that can be changed to accommodate non standard systems. For further information to change these parameters, please call Technical Support at 1-800-345-9422 Serious or fatal electrical shock may result from contact with internal electrical components. DO NOT, under any circumstances, attempt to modify connections to the drive until power has been removed and 10 minutes have passed for internal voltages to discharge Underload Sensitivity The Artesian Drive controller is configured at the factory to ensure detection of Underload faults in a wide variety of pumping applications including dead head and run dry conditions. In very rare cases (as with certain pumps in shallow wells) this trip level may result in nuisance faults. If the pump is installed in a shallow well, activate the controller and observe system behavior. Once the controller begins to regulate pressure, check operation at several flow rates to make sure the default sensitivity does not induce nuisance Underload trips. If it becomes necessary to desensitize the Underload trip level, please call of Technical Support at 1-800- 345-9422 for further details. Before Getting Started Serious or fatal electrical shock may result from failure to connect the ground terminal to the motor, Artesian Drive controller, metal plumbing, or other metal near the motor or cable, using wire no smaller than motor cable wires. To minimize risk of electrical shock, disconnect power before working on or around the Artesian Drive system. CAPACITORS INSIDE THE ARTESIAN DRIVE CONTROLLER CAN STILL HOLD LETHAL VOLTAGE EVEN AFTER POWER HAS BEEN DISCONNECTED. ALLOW 10 MINUTES FOR DANGEROUS INTERNAL VOLTAGE TO DISCHARGE BEFORE REMOVING ARTESIAN DRIVE COVER. Do not use motor or system in swimming areas. IMPORTANT: This equipment should be installed by technically qualified personnel. Failure to install it in compliance with national and local electrical codes and within F&W recommendations may result in electrical shock hazard, fire hazard, unsatisfactory performance, or equipment failure. Installation information is available directly from F&W at our toll-free number 1-800-345-9422. Use Artesian Drive only with properly sized three phase motors. Use of this unit with improperly sized motors may result in damage to both motor and electronics. Controller Location Selection The drive s enclosure is NEMA 1 rated and is intended for indoor use only. It should be mounted in a location that provides protection from water spray/drips and only be accessed by trained and authorized personnel. The Artesian Drive controller is intended for operation in ambient temperatures up to 122 F (50 C) at 230 VAC input. The following recommendations will help in selection of the proper location of the Artesian Drive unit: 1. A tank tee is recommended for mounting the tank, pressure sensor, pressure gauge, and pressure relief valve at one junction. If a tank tee is not used, the pressure sensor should be located within 6 feet (1.8 meters) downstream of the pressure tank to minimize pressure fluctuations. NOTE: There should be no elbows between the tank and pressure sensor and the tank should be between the the pump and pressure sensor. 2. The unit should be mounted on a sturdy supporting structure such as a wall or supporting post. Please take into account the weight of the unit (refer to the Specifications section under the appropriate model). 3. The electronics inside the Artesian Drive are air-cooled. As a result, there should be at least 4 inches of clearance on each side and below the unit to allow room for air flow. There should be at least 4 inches of clearance on each side and below the unit to allow room for air flow. Serious or fatal electrical shock may result from contact with internal electrical components. DO NOT, under any circumstances, attempt to modify connections to the drive until power has been removed and 10 minutes have passed for internal voltages to discharge 3 (022693 / FW1135)

4 4 Power Supply from Circuit Breaker 4 4 Power to Relief Valve Inlet Pump Leads Outlet Tank Leads Tank to Mounting Clearance 6 Ft. or Less IL0756 Figure 3a - Mounting Clearance for booster pumps 4 4 Power Supply from Circuit Breaker 4 4 Outlet Inlet Power to Relief Valve Pump Tank Figure 3b - Mounting Clearance - Centrifiugal Pumps Leads 6 Ft. or Less Tank to 4. Do not expose a Artesian Drive to rain or water spray. For outdoor installations, place the drive inside a NEMA 3R enclosure. Note: Please reference maxim temperature ratings listed above. Power Supply from Circuit Breaker Correct Power to Leads Power to Leads Figure 4 - Mounting Orientation Power Supply from Circuit Breaker IL0757 Incorrect 5. The Artesian Drive should only be mounted with the wiring end oriented downward. The controller should not be placed in direct sunlight or other locations subject to extreme temperatures or humidity (mounting location should not be subjected to freezing conditions or condensation). IL1201 6. The mounting location should have access to 230 VAC 3-Phase electrical supply and to the pump motor wiring. To avoid possible interference with other appliances, please refer to the enclosed Installation Guide and observe all precautions regarding power cable routing. Circuit Breaker and Wire Sizing The minimum circuit breaker size and maximum allowable wire lengths for connection of motor to the Artesian Drive are given in the following table: Table 1: imum Breaker Size and Maximum Cable Length (in Feet) Drive Model Recommended Input Cable Recommended Cable Maximum Cable Length to Recommended (Ft.) Breaker Maximum Continuous Current AD155145 12 14 655 20 15.5 AD220210 10 10 655 25 22.0 AD280280 8 8 655 30 28.0 A 10-foot section of cable is provided with the Artesian Drive to connect the pressure sensor. NOTE: Maximum allowable wire lengths are measured between the controller and motor. Aluminum wires should not be used with the Artesian Drive. Wire sizing between the service entrance and the controller must be sufficient to provide the required maximum input amps to the controller while conforming to local standards and codes. Artesian Drive minimum breaker amps may appear to exceed specifications for the three-phase motor because Artesian Drive controllers are supplied from a single-phase service rather than three-phase. Tank The Artesian Drive needs only a small pressure tank to maintain constant pressure (see table below for recommended tank size). The Artesian Drive can also use a bigger tank with a much larger capacity if available. Table 2: imum Tank Rated Pump Flow Tank Size (Total Volume) Pump Capacity less than 12 GPM 4 Gallon (AT15) Pump Capacity greater than 12 but 8 Gallon (AT25) less than 25 GPM Pump Capacity greater than 25 GPM 14 Gallon (AT44) The pressure tank pre-charge setting should be 70% of the system pressure sensor setting as indicated in the following table. Table 3: Tank Air Precharge (PSI) System (at ) Tank Precharge Setting (± 2 PSI) 30 21 35 25 40 28 45 32 50 35 55 39 60 42 65 46 70 49 75 53 80* 56 4 (022693 / FW1135)

*NOTE: High pressure applications above 80 PSI should be addressed through the Tech Support group at Flint & Walling (1-800-345-9422). Installation Procedure 1. Disconnect electrical power at the main breaker. 2. Drain the system of water (if applicable). 3. Install the pressure sensor (threaded connection down) at the pressure tank tee downstream of the pressure tank (the pressure tank should be between the pressure sensor and the pump). The pressure sensor has a 1/4-18 National Pipe Thread (NPT) connection. NOTE: The pressure sensor should not be installed in an inverted orientation (threaded connection up). Make sure the pressure sensor and tank are not located more than 3 feet off the main piping. 4. The unit should be mounted on a sturdy supporting structure such as a wall or supporting post. Please take into account the weight of the unit (refer to the Specifications section under the appropriate model). Install the unit to the wall using four mounting screws (not included) as shown in Figure 5. 6.1 in 14.5 in 8.6 in 14.6 in 4.2 in 1.0 in 13.3 in appropriate model) when installing in a through-panel configuration. Install the unit to the panel using three mounting screws (not included) as shown Figure 6. Wiring Serious or fatal electrical shock may result from failure to connect the motor, the Artesian Drive, metal plumbing and all other metal near the motor, or cable to the power supply ground terminal, using wire no smaller than motor cable wires. To reduce risk of electrical shock, disconnect power before working on or around the water system. To avoid a fire hazard and maintain validity of the UL listing, torque the power terminal screws to 13.2 lb.-in. (1.5 N-m). areas. Do not use motor or system in swimming Before beginning wiring 1. Verify that the power has been shut off at the main breaker. 2. Verify that the dedicated branch circuit for the Artesian Drive is equipped with a properly-sized circuit breaker. Refer to Table 2 (Page 8) for minimum breaker size. 3. Remove the Artesian Drive cover and bottom plate. Line up the alignment notches and slip the memory stick into the slot on the front of the controller. Note: Do not force the stick into place; it should slip into the slot and protrude about 3/4 from the face of the controller with the cover off when fully seated. (See Detail Figure 9). 4. Remove knock-outs as required on bottom plate. Install strain relief fitting (included) for the pressure sensor wire and strain relief fittings (not supplied) for the motor supply cable and power supply leads. 0.8 in Figure 5 IL0764 5. The unit can also be mounted in a through-panel configuration by using the through-panel mounting bracket, mounting gasket and appropriately cut hole in the panel as depicted below. Please take into account the weight of the unit (refer to the Specifications section under the 6.1 in 8.6 in 5.5 in 3.2 in 1.4±0.1 in 2.8±0.1 in 2.6±0.2 in 5.8±0.2 in 14.5 in 15.4 in 11.5 in 14.5±0.4 in 11.6±0.2 in IL0763 0.4±0.2 in 4.0±0.2 in Figure 6 5 (022693 / FW1135)

1 2 Remove knockouts as needed B4 B2 B5 2 1 V W U L1 L2 L3 Power Supply IL0761 GND Figure 7 5. Snap green plug-in terminal block into receptacle at the bottom of the drive. L1 L1 L2 L3 L1 L2 L3 L2 L3 U V W IL0776 Figure 10 To avoid a fire hazard and maintain validity of the UL listing, torque the Plug-in Terminal Block screws to 1.1 lb.-ft. (1.5 N-m) and Ground terminal nuts to 2.9 lb-ft. (4.0 N-m). 8. Install ground cable bridge and attached ground cables as shown. U V W U V W IL0777 Figure 8 6. Feed the motor supply cable through appropriate strain relief fitting on bottom plate and connect them to the terminal block positions marked U, V and W. IL0762 Proper motor rotation must be checked after the system has been initially started. If motor is running in the wrong direction, connection U & V should be switched at the drive for proper motor rotation and performance. Figure 11 9. Feed the pressure sensor leads through appropriate strain relief on the bottom of the Artesian Drive unit and connect the red and black leads to the terminals marked B2 and B5 (interchangeable) with a small screwdriver (provided). Make sure to not disconnect the factory installed jumper wire that is already connected to terminal B2. Note: A 10-foot section of pressure sensor cable is provided with the controller, but it is possible to use similar 20 AWG wire for distances up to 100 feet from the pressure sensor. V L1 L2 L3 W 10. Press the memory stick guard into the slot in the front cover as shown; do not press fully into position. Replace the controller bottom plate and cover. Do not over-tighten the screw. L1 L2 L3 U V W U MOTOR LEAD CONNECTIONS IL0775 Figure 9 7. Feed the 230 VAC power leads through appropriate strain relief fitting on bottom plate and connect them to the terminals marked L1, L2 and L3 IL0780 Figure 12 11. Connect the other end of the pressure sensor cable with the two spade terminals to the pressure sensor. The connections are interchangeable. 6 (022693 / FW1135)

Remove Rubber End Cap to Adjust with 7/32 Allen Wrench Boot Figure 13 12. Set the pressure tank pre-charge at 70% of the desired water pressure setting. To check the tank s pre-charge, depressurize the water system by opening a tap. Measure the tank pre-charge with a pressure gauge at its inflation valve and make the necessary adjustments. 13. The pressure sensor communicates the system pressure to IL0730 the Artesian Drive controller. The sensor is preset at the factory to 50 psi, but can be adjusted by the installer using the following procedure: a. Remove the rubber end-cap. b. Using a 7/32 Allen wrench (provided), turn the adjusting screw clockwise to increase pressure and counterclockwise to decrease pressure. The adjustment range is between 30 and 80 psi (1/4 turn = approximately 3 psi). c. Replace the rubber end cap. d. Reset the pressure tank pre-charge to the appropriate pressure. e. Cover the pressure sensor terminals with the rubber boot provided. When increasing the pressure, do not exceed the mechanical stop on the pressure sensor or 80 psi. The pressure sensor may be damaged. Diagnostic Fault Codes Should an application or system problem occur, built-in diagnostics will protect the system. The display will change to indicate the nature of the fault. In some cases, the system will shut itself off until corrective action has been taken. Fault codes and the recommended corrective action for each are listed in the following chart. Do not attempt to carry out internal repairs. Return a faulty drive to the supplier for repair. Table 4: DIAGNOSTIC FAULT CODES Display Code Fault Possible Cause Corrective Action Underload Air-locked pump. Overpumped or dry well. Worn pump. Damaged shaft or coupling. Pump deadhead. Blocked pump or screen. Undervoltage Low line voltage. Misconnected input leads.. Locked Pump /pump misaligned. Abrasive/Sand-bound pump. Dragging pump or motor.. Short Circuit When fault is indicated immediately after power-up, short circuit due to loose connection, defective cable, splice or motor.. Over Current When fault is indicated while motor is running, over current due to loose debris trapped in pump, or water demand is exceeding pump & motor s capability.. (Number other than 0.0 & motor is not running) Open Circuit Loose connection. Defective motor or cable... Overheated Controller High ambient temperature. Direct sunlight. Obstruction of air-flow. 7 (022693 / FW1135) Wait for well to recover and automatic restart timer to time out. If the problem does not correct, check motor and pump. See description of Intelligent Reset on Page 18. Check for loose connections. Check line voltage. Report low voltage to the power company. Unit will start automatically when the proper power is supplied. Unit will attempt to free a locked pump. If unsuccessful, check the motor and pump. Check motor wiring. Turn power off till display darkens then apply power again to reset. Check pump. With power off, check motor, motor wiring and splices. Make certain all connections are tight. Apply power again to reset. This fault automatically resets when the temperature returns to a safe level.. Controller Stopped Loose jumper wire Re-insert jumper wire into control terminals B2 & B4.

table 6 System Troubleshooting Guide Symptom Possible Cause Corrective Action /Pump is running backwards. Reverse connection of motor cable wires at connection point U & V. Pump capacity cannot supply the demand. Use pump with higher flow rating (if head requirement is still satisfied). Water flow rate is not as high as expected. Excessive pressure fluctuations. runs continuously with no flow demand. Temperature in the controller is too high. If the controller s heat exchanger becomes too hot, the controller will reduce the switching frequency to the motor to lower the power consumption. Disconnected or broken wire feeding motor. Waterlogged tank. tank is too small for flow rating of the pump. Leak in the household or outdoor plumbing. Leak in the pitless adapter. NOTE: Ensure that the system is properly grounded all the way to the service entrance panel. Improper grounding may result in the loss of voltage surge protection and interference filtering. Special Instructions for Outdoor Installation To install the Artesian Drive in an outdoor installation, the drive must be placed inside NEMA 3R enclosure (Not Included). Start-Up and Operation Apply power to the controller. As long as the display is lit up the system has power. When the display shows. or flashes PLC as shown, the system is active, but the pump is not running. The display will show. as shown (where the numbers may be fluctuating) when the pump is running. Figure 14 IL0748 8 (022693 / FW1135) Make sure there is at least 4 inches of room around the controller for movement of air. Avoid direct sunlight. Reduce ambient temperature below 104 F (40 C). Increase input voltage if below 230 VAC. Check motor, motor wiring and splices. Make certain all connections are tight. Check tank for bladder damage. Replace if necessary. Reset the tank pre-charge pressure (should be 70% of pressure sensor setting). Use larger tank (refer to Table 3 on Page 4 for minimum Tank size). Check for leaky faucets, valves and/or pipe fittings and repair. Re-seat the pitless adapter. Replace seal as needed. Leaky Systems Leaky water systems might keep the controller running due to the accurate pressure sensing capability of the pressure sensor. Continuous running or starts and stops do not hurt the controller, pump or motor. However, to reduce the on-time of the controller/pump/motor, a Bump-Mode procedure has been programmed into the drive. During very low flow (or leaky) conditions this feature periodically increases the speed of the pump several PSI above the set point and shuts off the pump. This adds some time to bleed off before the system starts up again. This Bump-Mode can be turned off if desired. Please call Technical Support at 1-800-345-9422 for further details. NOTE: Artesian Drive maintains a constant pressure at the pressure sensor. Although the pressure is constant at the pressure sensor, pressure drops may be noticeable in other areas of the system when additional taps are opened. This is due to restrictions in the plumbing and will be more pronounced the farther the taps are from the pressure sensor. This would be true of any system, and if observed, should not be interpreted as a failure in the performance of the Artesian Drive. Although the pressure sensor can be adjusted up to 80 PSI, the maximum obtainable pressure in the system is dependent upon the full load capability of the pump at a given flow. For example, a pump is only capable of producing a pressure of 60 PSI at the flow demand. Increasing the pressure setting of the pressure sensor to 75PSI would only result in the pump running at full speed and producing a pressure of 60 PSI. Underload Intelligent Reset (Display showing ) If a motor Underload fault condition occurs, the most likely cause is an overpumped well (dry well) or loss of incoming feed water to the pump. In a dry well situation to allow the well to recover, the Artesian Drive controller will wait 30 seconds to 5 minutes, determined by the amount of time the motor had been running before sensing the underload, before restarting the motor. For example, the first time the fault occurs and the pump has been running 6 minutes, the controller stops the motor and will wait 30 seconds before attempting to restart the pump. If the system would then run for 2 minutes and an underload fault recurs, the controller will wait 3 minutes before attempting to restart the pump. This schedule allows for the minimum off-time possible based on the recovery time of the well or water feed supply. If there is an obstruction (such as a closed valve) between the pump and the pressure sensor, the controller will also sense an underload is this dead head condition stopping the motor to avoid damaging the pump.

Off Time (.) 6.0 5.0 4.0 3.0 2.0 1.0 0.0 0 1 2 3 4 5 6 7 8 Run Time (.) Figure 15 IL0750 Over-Temperature The Artesian Drive controller is designed for full power operation in ambient temperatures up to 104 F (40 C) as long as the input voltage is kept at 230 VAC. Under extreme thermal conditions, the controller will reduce the switching frequency in an attempt to avoid shutdown. If the temperature of the controller is still too hot the controller will shut itself off to avoid causing damage to itself. Full pump output is restored when the controller temperature cools to a safe level. NOTE: The Artesian Drives are factory programmed to F&W pumps to provide optimum performance and motor protection. The Artesian Drive can be used with other pumps, but the maximum motor amperage needs to be compared to the factory programmed current value (refer to the Specifications section under the appropriate model). If the maximum motor current varies more than 5% from the programmed value, the motor current value in the drive needs to be changed for motor protection and optimum performance. For details on how to change this value in the drive, please contact Technical Support at 1-800-345-9422. DRIVE SPECIFICATIONS AND DIMENSIONS Model Number AD155145 AD220210 AD280280 Input from power source Voltage Frequency 180-264 AC (Three Phase) 50/60 Hz Current (Max) - RMS 18.1 Amps 22.6 Amps 28.3 Amps Power Factor 1.0 ( constant ) Voltage Frequency Range Voltage Automatically Adjust with Frequency (0 thru 230 Volts) 15-60 Hz Output to (Three Phase ) Current, Factory Programmed* (RMS, Each Phase) 14.5 Amps 20.0 Amps 28.0 Amps Current (Max) (RMS, Each Phase) 15.5 Amps 21.0 Amps 28.0 Amps For Use With Standard 60 Hz. Pump & 230 Volt 3 Phase Combination Reference HP Rating* 5 7.5 10 Setting Factory preset 50 PSI Adjustable Range 30-80 PSI Temperature Operating Conditions (@ 230 VAC input) 0 to 50 C (32 to 122 F. ) Relative Humidity Max 95% Non-condensing Controller Size NEMA 1 ( indoor ) 14.5 H x 6.1 W x8.6 D Weight 15.4 lbs. 15.4 lbs. 15.4 lbs. RMS = ROOT MEAN SQUARED * The electrical characteristics of motors vary slightly. See Amp draw on motor nameplate. If the maximum motor current value (Amp draw) is more than 5% of the programmed value of the Drive, the Drive will need to be set to the current value of the motor to provide proper protection.. 9 (022693 / FW1135)

B2 B4 B5 Quick Reference Guide to Controller Installation (Item not to scale) of passing full pump flow at 100 psi. Install the pressure relief valve between the pump and pressure tank. Many pumps can develop excessive pressure resulting in equipment and property damage as well as possible injury. Always install a pressure relief valve capable L1 L2 L3 U V W Power Supply Lead GND Figure 16 - Quick Reference Guide to Controller Installation - Booster Pumps 10 (022693 / FW1135)

Table 2: imum Tank Rated Pump Flow Tank Size (Total Volume) Pump Capacity less than 12 4 Gallon (AT15) GPM Pump Capacity greater than 8 Gallon (AT25) 12 but less than 25 GPM Pump Capacity greater than 14 Gallon (AT44) 25 GPM The pressure tank pre-charge setting should be 70% of the system pressure sensor setting as indicated in the following table. Table 3: Tank Air Precharge (PSI) System (at ) Tank Precharge Setting (± 2 PSI) 30 21 35 25 40 28 45 32 50 35 55 39 60 42 65 46 70 49 75 53 80 56 *NOTE: High pressure applications above 80 PSI should be addressed through the Tech Support group at Flint & Walling (1-800-345-9422). Cable (Included) Tank Precharge Inflation Valve Check Valve Gauge Tank From Municipal Isolation Valves Check Valve Relief Valve Discharge into drain rated for max pump output at relief pressure Drain Valve To Service Inlet GND Pump IL0758 Outlet BOOSTER PUMP 11 (022693 / FW1135)

B2 B4 B5 Power Supply Lead L1 L2 L3 U V W GND Figure 16 - Quick Reference Guide to Controller Installation - Centrifugal Pumps 12 (022693 / FW1135)

Cable (Included) Tank Precharge Inflation Valve Check Valve Gauge Tank From Municipal Isolation Valves Check Valve Outlet Relief Valve Discharge into drain rated for max pump output at relief pressure Drain Valve To Service Inlet Pump GND CENTRIFUGAL PUMP IL1202 13 (022693 / FW1135)