COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

Similar documents
COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE Terminal Dome Closure 6.5" x 22"

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE LCC (Low Count Closure)

COYOTE STP (Service Termination Point)

COYOTE STP (Service Termination Point)

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

Section 1 COYOTE Closure Series

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Section 1 COYOTE Closure Series

Section 1 COYOTE Closure Series

CS Fiber Optic Splice Case. Instruction

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

Section 3 FIBERLIGN Closure Series

INSTALLATION INSTRUCTIONS

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

INSTALLATION INSTRUCTIONS

Closure End Plates and Accessories

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

Environmental Distribution Center (EDC-06P-NH)

3000SC Fiber Optic Splice Closure

8400 Series Fiber Distribution System

Section 1 COYOTE Closure Series

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Fiber Splice Panel Rack Mount User Manual

Opti-Guard Splice Enclosure

INSTALLATION INSTRUCTIONS

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

INSTALLATION & OWNER S MANUAL

SPORTSTER SADDLEBAG KIT. i i02212

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Fiber optic splice closure

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

3M Fiber Dome Closure FDC 10

YOURx-Aerial Terminal Installation Manual

UNPACK AND IDENTIFY THE FOLLOWING PARTS.

One- Touch Installation Instructions

INSTALLATION & OWNER S MANUAL

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

FOSC-400A4 INSTALLATION INSTRUCTION

OPTICAL FIBER CLOSURE

INSTALLATION & OWNER S MANUAL

FIBER CONNECTOR SAFETY WARNINGS

Installation Guide Current Ford F-250 & Ford F-350 Super Duty. Product Code: 109 & 119

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

3M Closure System 2-Type Cover (505)

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

INSTALLATION & OWNER S MANUAL

LPE C5 Battery Relocation Kit

Wildcat System Instructions

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

INSTALLATION & OWNER S MANUAL

Universal Splice Tray Installation Instructions

H15P. Toyota Hilux A-DECK Dual Cab

Instructions for Use - Opt-X 1000i Enclosure

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

FL2000 Termination/Splice Panels User Manual

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Installation Instructions INDY SHIFTER Fits: Mustang Fastback & Convertible with MT-82 Transmission Catalog #

155 CARTRIDGE SINGLE SEAL

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

INSTALLATION & OWNER S MANUAL

Section 10 ARMADILLO Stainless Series

Installation Instructions

#GL18006-L2 Honda Gold Wing 1800 & F6B models - All Years Lower Cowl LED Driving Lights INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE STANDARD PRODUCT CODES:

PONTIAC FIREBIRD

Installation Instructions

4400 TwinHybrid Gas Seal

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor

C15C C15C. Page 1 of 20

Subaru Front Mount Intercooler Kit STI Subaru Front Mount Intercooler Kit STI

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

WAVETRAX USER MANUAL

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

FARM MODEL INSTALLATION INSTRUCTIONS

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

INSTALLATION & OWNER S MANUAL

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

Service Manual Air Plus Second Stage

FOG LAMPS INSTALL KIT

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

Stowe Cargo Management System

Q15P. Mitsubishi MQ Triton Dual Cab

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

INSTALLATION MANUAL. Thunderstone Manufacturing LLC 3400 West O Street Lincoln, NE (Fax)

INSTALLATION INSTRUCTIONS

Bag 1. Bag 1. Center Pivot. Center Pivot

Transcription:

FEBRUARY 2015 COYOTE Dome Cross-Connect Closure 6-1/2" x 22" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1 2 3 8 9 10 11 *5 6 7 *4 12 13 NOMENCLATURE 1. Dome cover (1) 2. Organizer with 4-port end plate assembly (1) 3. *Splice Tray (Small LITE-GRIP tray shown) 4. *Adapter panel 5. *Fiber pigtail kit 6. Plastic organizer clip (8) *Customer Selected Items 7. Adapter plate brackets (2) 8. Dome collar (1) 9. Dome gasket (1) 10. Cable grommet (2) 11. Hose clamp (4) 12. Silicone lubricant (4-five gram packets) 13. Disposable glove (1) TOOLS REQUIRED 3/8" & 7/16" can wrench or socket 1/4" nut driver or screwdriver Snips Fiber optic cable opening tools COYOTE Dome Cross-Connect Closure Kits 6.5" x 17" and 6.5" x 22" Catalog Number Description 800012185 COYOTE Dome Cross-Connect Closure 6.5" x 17" Includes: (2) Grommets, (1) Cross Connect Organizer Assembly with 4-Port End Plate Assembly, (1) Dome, (1) Collar Assembly, (1) Gasket, (8) Plastic Organizer Clips, (2) Adapter Plate Brackets, (1) Disposable Glove, (1) Silicone Lubricant Packet, & (4) Hose Clamps 800012184 COYOTE Dome Cross-Connect Closure 6.5" x 22" Includes: (2) Grommets, (1) Cross Connect Organizer Assembly with 4-Port End Plate Assembly, (1) Dome, (1) Collar Assembly, (1) Gasket, (8) Plastic Organizer Clips, (2) Adapter Plate Brackets, (1) Disposable Glove, (1) Silicone Lubricant Packet, & (4) Hose Clamps Catalog Number Accessory Kits 80808456 COYOTE Dome End Plate Fixture Catalog Number 8003716 Aerial Mounting Bracket (End Plate Mount) 8003831 Aerial Mounting Bracket (Dome Mount) Mounting Brackets 8003833 Aerial Mounting Bracket for ADSS Applications (Dome Mount) 8003702 Pole/Wall Mounting Bracket 8003835 Universal Mounting Bracket Kit for Hand Hole Applications 8003707 Swing Arm for Hand Hole Applications 1

COYOTE Dome Cross-Connect CAccessories Catalog Number Description Catalog Number Description Adapter Plate / Connector Kits 6SMSC Adapter Plate Module, 6 port, SC, SM, ceramic sleeve 6SMFC Adapter Plate Module, 6 port, FC, SM, ceramic sleeve 6SCAPC Adapter Plate Module, 6 port, SC, SM, APC, ceramic sleeve 8SMFC Adapter Plate Module, 8 port, FC, SM, ceramic sleeve 12SMDSC Adapter Plate Module, 12 port, six dual SC, SM, ceramic Adapter Plate Module, 6 port, FC, SM, APC, ceramic sleeve 6FCAPC sleeve 12MMDSC Adapter Plate Module, 12 port, six dual SC, MM, metal Adapter Plate Module, 6 port, LC, SM, ceramic sleeve 6SMLC sleeve 8SMSC Adapter Plate Module, 8 port, SC, SM, ceramic sleeve Adapter Plate Module, 12 port, six dual LC, SM, ceramic 12SMLC sleeve 8SCAPC Adapter Plate Module, 8 port, SCAPC, SM, ceramic sleeve 6MMST Adapter Plate Module, 6 port, ST, MM, metal sleeve 6SMST Adapter Plate Module, 6 port, ST, SM, ceramic sleeve 600 Blank Filler Panel 8SMST Adapter Plate Module, 8 port, ST, SM, ceramic sleeve Pigtail Accessory Kits P6SCU3 6 Simplex, 900 Micron, Color Coded, SC, SM, 3 meter P6FC3 6 Simplex, 900 Micron, Color Coded, FC, SM, 3 meter P12SCU3 12 Simplex, 900 Micron, Color Coded, SC, SM, 3 meter P12FC3 12 Simplex, 900 Micron, Color Coded, FC, SM, 3 meter P6SCA3 6 Simplex, 900 Micron, Color Coded, SC, SM, APC, 3 meter P12FC5 12 Simplex, 900 Micron, Color Coded, FC, SM, 5 meter P12SCA3 12 Simplex, 900 Micron, Color Coded, SC, SM, APC, 3 meter P12FCA3 12 Simplex, 900 Micron, Color Coded, FCAPC, SM, 3 meter P12SCA5 12 Simplex, 900 Micron, Color Coded, SC, SM, APC, 5 meter P6LC3 6 Simplex, 900 Micron, Color Coded, LC, SM, 3 meter R12SCU3 Ribbon, 12 Fiber, Color Coded, SC, SM, LC, APC, 3 meter P12LC3 12 Simplex, 900 Micron, Color Coded, LC, SM, 3 meter R12SCA3 Ribbon, 12 Fiber, Color Coded, SC, SM, APC, 3 meter P6STM3 6 Simplex, 900 Micron, Color Coded, ST, MM, 3 meter P6ST3 6 Simplex, 900 Micron, Color Coded, ST, SM, 3 meter P12SCM3 12 Simplex, 900 Micron, Color Coded, SC, 62.5, 3 meter P12ST3 12 Simplex, 900 Micron, Color Coded, ST, SM, 3 meter Splice Trays for COYOTE Dome Cross-Connect Closure 6.5" x 17" and 6.5" x 22" Kits 80807701 Low Profile Splice Tray with plastic splice blocks (12 splice count) 80807531 Low Profile Splice Tray (blank) no splice blocks (12 splice count) 8003468 24 Count Low Profile Splice Tray with plastic splice blocks (36 splice count) 80806033 Standard Splice Tray with elastomeric splice blocks (12 splice count) 80806182 Standard Splice Tray (blank) no splice blocks (12 splice count) 80807114 Ribbon Splice Tray with elastomeric splice blocks (72 splice count) 80808160 Ribbon Splice Tray (blank) no splice blocks (72 splice count) LGSTS16 LITE-GRIP Splice Tray with Yellow 8-Hole LITE-GRIP splice blocks single fusion splices (Splice tray is provided wth splice blocks to support 16 splices but has the capacity for 40 splices). Splice Block Kit (Cat. # LGSBS8-5) is required to achieve maximum tray capacity. LGSTR144 LITE-GRIP Splice Tray with Purple 3-Hole LITE-GRIP splice blocks mass fusion/ribbon splices (144 splice count) Splice Tray/Closure Capacities for Cross-Connect Splice Tray Depth Description Trays per Closure 6.5" x 17" 6.5" x 22" Closure Splice Capacity Trays per Closure Closure Splice Capacity Low Profile Single Fusion 4 48 4 48 24 Count Low Profile Single Fusion N/A N/A 3 72 Standard Single Fusion or Mechanical 3 36 3 36 Ribbon Mass Fusion 2 144 2 144 LITE-GRIP Single Fusion 2 80 2 80 LITE-GRIP Mass Fusion 2 360 2 360 2 2015 Preformed Line Products Company. All rights reserved.

COYOTE Grommet Chart For use in COYOTE ONE Dome, Dome, GLC, In-Line RUNT, Terminal, Taut, LCC, & Aerial Drop Closures PLP Catalog Number Cable Range Inches (mm) Description Splitting Location 8003701.42 -.60 (11-15 mm) &.60 -.85 (15-22 mm) 2-entry grommet 8003691.42 -.60 (11-15 mm) 1-entry grommet 8003692.60 -.85 (15-22 mm) 1-entry grommet 8003693.85-1.0 (22-25 mm) 1-entry grommet 8003694 1.0-1.25 (25-32 mm) 1-entry grommet 8003663.42 -.60 (11-15 mm) 2-entry grommet 8003990.50 -.60 (12.7-15.2).125 -.25 (3.2-6.4) and flat drop 4-entry grommet 8003664.30 -.43 (8-11 mm) 4-entry grommet 8004065.250 -.312 (6.4 mm - 7.9 mm) 4-entry grommet 8003665.125 -.25 (3-6 mm) and flat drop cable 6-entry grommet 8003676.42 -.60 (11-15 mm),.125 -.25 (3-6 mm), and flat drop cable 7-entry grommet 8003677.125 -.25 (3-6 mm) and flat drop cable 8-entry grommet NOTE: Grommet Kit contains (1) Grommet, (1) Cable Measure Tape, (2) Silicone Lubricant Packs, (1) Set of Plugs (Multi-Entry Grommets only) 3

End Plate Preparation Step #3a Optional Step Install support bracket onto base. Step #1a Remove end plate from organizer assembly. Loosen wing nut so slotted tab of support bracket can slide behind wing nut. Position support bracket onto base and secure with wing nuts. Base can be secured to work surface with either clamps or with bolts. Note: Do not tighten wing nut until end plate is installed. Step #1b Remove the end plate caps from the selected cable ports and break out the tabs. Step #3b Optional Step Seat the end plate onto the cushion wedges and secure the support bracket to the stud of the end plate. The outside surface of the end plate must rest against the support bracket. Support Bracket PLP Tip: Scoring edges of tabs with knife makes them break out easier. Break out entrance ports 3 and 4 for expressed feeder fiber. Step #1c Break out entrance port 2 for local fiber. Step #2 Optional Step For better stability during cable installation and fiber splicing, install the end plate onto the COYOTE Dome End Plate Fixure (see Steps 3a-b for installation details). Hand tighten any loose wing nuts to secure end plate to fixture. Step #4 Grommet location Lay cable into entry point and mark for grommet and sheath opening locations. 1.75" (45 mm) 4 Mark for sheath opening PLP Tip: Hole in strength member bracket is a guide for sheath opening.

Step #5 Measure cable to determine diameter and hole location to use in grommet. Step #7 Grommet Slitting If slitting is required, lay grommet on a stable flat surface. Position utility knife with the cutting edge against the top surface and cut through grommet. Consult grommet chart on page 3 for slitting locations of all grommets. Step #6a Diameter range top hole Step #6b If using cut cable, insert cable through grommet. If your application requires express/balloon/ring cut cables, see Step 7 for grommet slitting procedure. Diameter range bottom hole Install plug in unused port Installing Figure 8 Style Cables and Cables with Tracer Wires Remove tracer wire or ground wire from the portion of the cable that will be positioned in the grommet and insert the cable into the grommet. Cable with Tracer Wire PLP Tip: Use a pen to sketch slitting lines on top surface of grommet prior to cutting. Slit Step #8a Not Correct Slitting Angle Buffer (Loose) Tube Cable Slit Correct Slitting Angle Trim strength members to length. Prepare feeder and local cable(s) for cut applications. Strength Member Minimum Sheath Opening for Cut Cable Applications 82" 2.1 m 2.5" (6.4 cm) Step #8b Prepare cable(s) for mid sheath applications. (Express/Balloon/Ring Cut). Not Correct Installation Correct Installation 82" (2.1 m) OFFICE/C.O. Buffer (Loose) Tube Cable Figure 8 Style Cable XA For Applications Where Fiber is Dedicated to the Splice Point Sheath Opening 82" (2.1 m) Not Correct Installation Correct Installation Fiber/Buffer Tube Cut Location A (see image above) 5

Step #8c Prepare cable for expressed fiber (buffer tube window cut) applications. Buffer Tube Opening C Locations for Window Cut X C X 106" (2.7 m) OFFICE/C.O. Step #10b For Wide Range 2-Hole Grommets, make sure arrows are pointing down when inserting grommet(s). Position grommet in end plate slot. For Applications Where Fiber is Expressed through the Buffer Tube Sheath Opening 106" (2.7 m) Buffer Tube Opening Location C (see image above) Do not align grommet slit with end plate seam. Step #9 If shielded cable is being used, install shield connector on shielded cables. See Step #16 for recommended bonding practice. Step #11 Install cable cap and secure with hex bolts. Tighten bolts by hand evenly until cable cap is fully seated. (DO NOT USE POWER TOOLS TO TIGHTEN BOLTS). Follow standard company practices. Step #10a Lubricate the outer surface of the grommet. PLP Tip: To start cable cap bolts, apply pressure with thumb and line up bolts with inserts. Engage 1 or 2 threads on one of the bolts. Repeat the process on opposite bolt. Alternate tightening until fully seated. Lubricate sealing surface of grommet with silicone lubricant provided. Step #12 Important Note: Tighten all unused cable caps. Complete end plate assembly. 6

Step #13 Secure organizer assembly to end plate with 1/4 hex bolt and hex nut. Step #16 Attach bonding device between the cable and ground stud in the end plate and ground per your accepted company practice. Step #14 Trim cable strength member(s) even with the edge of the cable restraint bracket. Secure strength member(s) and **KEVLAR under clip and tighten screw. Step #17 Organizer Preparation Properly orient brackets. Secure adapter plate(s) to brackets. Brackets Adapter plate Step #15 Secure cable sheath with hose clamp. Step #18 Select adapter plate assembly location. PLP Tip: Use locations A and C only when 2 adapter plate assemblies are required. PLP Tip: Avoid contact between hose clamp and shield connector to maintain isolation of each cable ground. **KEVLAR is a registered trademark of the DuPont Company. 7

X Step #19 Secure adapter plate assembly to mainframe with fasteners provided. Step #22 Determine feeder and local pigtail length based upon adapter plate location. See charts below. Step #20 Route and store buffer tubes in storage brackets. Plate Location Feeder Pigtail Length Local Pigtail Length A 57" (145 cm) 50" (127 cm) B 63" (160 cm) 47" (119 cm) C 64" (163 cm) 44" (112 cm) Critical Step: Position assembly according to image in Step 21a to insure selected fiber is cut at the proper location. Step #21a Select feeder fiber to be spliced. Cut fiber to be spliced here Plate Location Step #23 Yellow Braid Length Feeder Pigtails Yellow Braid Length Local Pigtails A 23-1/2" (60 cm) 14-1/2" (37 cm) B 25-3/4" (65 cm) 11-1/2" (29 cm) C 29" (74 cm) 8-1/2" (22 cm) Route incoming fibers and outgoing pigtails, and splice per standard company practices. Cut fiber INCOMING FIBER OUTGOING PIGTAILS Step #21b Measure and mark buffer tube 51" from cable sheath opening. Remove buffer tube beyond this mark to expose fiber to be spliced. Step #24 Install tray(s) onto mounting studs and secure with nuts. Do not over tighten nuts. 8 51 (130 cm)

Step #25 Install storage bracket bar and secure with nuts. Step #29 Slide prelubricated end plate gasket onto end plate and press into groove. Make sure gasket is seated in groove of end plate Step #26 Install organizer clips into desired holes. Organizer clips. Step #30 Re-tighten all cable cap bolts (step #11) to assure that the cable caps are fully seated. When using a can wrench or nut driver, the installed torque is 35 to 40 in-lbs. Step #27a Route and install feeder pigtails to adapter plate. Step #31 Work the gasket into the groove. Step #27b Route and install local pigtails to adapter plate. Step #32 Position the dome over end plate. Dome & Collar Installation Step #28 Lubricate all inner surfaces of the gasket. Lubricate all surfaces around gasket with silicone lubricant to assure easy assembly and closure re-entry. Lubricate all outer surfaces of the gasket. 9

Step #33 Position the collar flat on the work surface in front of the closure as shown below. Step #36 Check to make sure the lip of the dome is captured within the collar half. Front Side Lip of dome is captured within collar. Back Side Step #34 Step #35 10 While holding the collar in place, compress a portion of the end plate into the dome and insert them in the groove of the collar near the latch, as shown below. While holding the collar in place, push against the end of the dome and slightly lift and push the other half of the dome up and over the lip of the collar with your fingers to fully install the dome in the collar half. Lip of dome is captured within collar. Step #37 Install the other collar half onto the closure. Step #38 Secure the collar with the latch and pin.

Step #39 Flash Test Procedure Remove cap from air valve of end plate. Step #41 Spray all sealing surfaces of the dome end-plate with soapy water to determine if there are any leaks. Step #40 Pressurize closure up to a max of 10 psi. Step #42 Release the pressure in the closure using the bump on the top of the air valve cap. 11

Common End Plate Leaks During Flash Testing 17.85" (453 mm) Leak occurring at the corner of the cable port due to the cap of the cable port not being fully tightened. 8.57" (218 mm) 10.04" (256 mm) Leak occurring at the corner of the cable port To resolve, remove collar, remove End Plate/ Organizer Assembly from the Dome, and tighten bolts on end cap where leak occurred. Reassemble and flash test to confirm that the leak has stopped. 8.57" (218 mm) 22.60" (574 mm) Leak occurring at the cable entry of the grommet due to the cable not being within the stated cable diameter range of the grommet Leak occurring at the cable entry of the grommet To resolve, remove collar and remove End Plate/Organizer Assembly from the Dome. Remove end cap where leak occurred, remove grommet, remeasure cable with measure tape provided and select proper grommet. Reassemble the components and flash test the closure to confirm that the leak has stopped. 12

Step #43a Aerial Mounting Options For 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Assemble each bug nut or ADSS clamp to each top aerial offset bracket as shown below. Step #43c For 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). For Taller Spacing. Align the top aerial offset bracket with the bottom aerial offset bracket in either Position 1 or Position 2 as shown below. Secure the top aerial offset bracket to the bottom aerial offset bracket with the bolts and keps nuts provided. Strand Clamp Position 1 Strand Clamp Shown ADSS Clamp Position 2 Strand Clamp Shown Step #44 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Insert hose clamp through slots in each of the bottom aerial offset brackets. Step #43b For 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). For Shorter Spacing. Align the top aerial offset bracket with the bottom aerial offset bracket in either Position 1 or Position 2 as shown below. Secure the top aerial offset bracket to the bottom aerial offset bracket with the bolts and keps nuts provided. Step #45 Slots 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Tighten each hose clamp around the dome. Position 1 ADSS Clamp Shown Position 2 ADSS Clamp Shown 13

Step #46 Strand Aerial Offset Bracket shown secured on a 6.5" Dome 6.5" Dome Strand Mount Aerial Offset Bracket Kit (P/N: 8004035) and 6.5" Dome ADSS Mount Aerial Offset Bracket Kit (P/N: 8004036). Bracket installed on dome closure. Step #49 COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Position the brackets in the banding channels of the dome. Tighten the banding until the brackets are secure. Step #47 Hand Hole Mounting Option COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Secure the Universal Mounting Bracket to the inner wall of the hand hole using 2 screws. Step #50 COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Slide the hanger brackets into the proper slots of the Universal Mounting Bracket and snap the hinged lid into place to secure the hanger brackets. Step #48 COYOTE Universal Mounting Bracket for Hand Hole Applications (P/N: 8003835). Insert banding (plastic or metal) through the slots of the hanger brackets. 14

Step #51 Pole/Wall Mounting Option The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Position the bolts through the stud mount plate as shown, and install lock nuts on bolts until there is a 1/8" (3 mm) gap between the nut and the stud mount plate. Step #53 The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Attach the dome pole/wall mount bracket to a pole or wall with either 5/8" through bolts, 1/4" lag screws, or banding straps. 1/4" Lag Screw Hole Stud Mount Plate Banding Slots 1/4" Lag Screw Hole 5/8" Through Bolt Holes Step #52 1/8" (3mm) The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Slide the bolts of stud mount plate into the slots of the pole/wall mount bracket as shown and tighten the lock nuts until the plates are secure. Step #54 The 6.5" COYOTE Dome Pole/Wall Mount Bracket (P/N: 8003702). Attach the COYOTE Dome closure to the pole/ wall mount bracket by inserting the studs of the dome closure end plate through the stud holes of the stud mount plate and securing with the lock nuts provided. Stud Mount Plate Pole/Wall Mount Bracket Secure Lock Nuts Secure Lock Nuts 15

Step #55a Dome Aerial Mounting Bracket Dome Mount for 6.5" x 17" or 22" Dome Closures. The COYOTE Dome Mount Aerial Bracket Kit (Cat. No. 8003831) can be used to suspend the COYOTE Dome closure from the messenger wire. To install the dome mount aerial brackets, position the brackets in the banding channels of the dome and insert banding (plastic or metal) through the slots of the brackets. Tighten the banding until the brackets are secure before mounting the closure to the messenger wire with the bug nuts of the brackets. Bug Nut Dome Aerial Hanger Bracket Strap Dome Mount Aerial Brackets Banding Channels Step #55b The COYOTE Dome Mount Aerial Bracket Kit for ADSS (Cat. No. 8003833) can be used to suspend the 6.5" x 17" or 6.5" x 22" COYOTE Dome closure from ADSS cable. To install the dome mount aerial brackets, position the brackets in the banding channels of the dome and insert banding (plastic or metal) through the slots of the brackets. Tighten the banding until the brackets are secure before mounting the closure to the ADSS cable with the ADSS clamp. ADSS Clamp Dome Aerial Hanger Bracket Strap Dome Mount Aerial Brackets Banding Channels SAFETY CONSIDERATIONS This application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual. FAILURE TO FOLLOW THESE PROCEDURES MAY RESULT IN PERSONAL INJURY OR DEATH. Do not modify this product under any circumstances. This product is intended for use by trained technicians only. This product should not be used by anyone who is not familiar with, and not trained to use it. When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. For proper performance and personal safety, be sure to select the proper size PREFORMED product before application. PREFORMED products are precision devices. To insure proper performance, they should be stored in cartons under cover and handled carefully. P.O. Box 91129, Cleveland, Ohio 44101 440.461.5200 www.preformed.com e-mail: inquiries@preformed.com SP2979-3 16 **KEVLAR is a registered trademark of the DuPont Company.