TTXLSERIES. Technical Reference Guide

Similar documents
TTXL SERIES FEATURES: Unique Design Features Include:

TTXR SERIES FEATURES: Unique Design Features Include: Fully Enclosed Flow-Thru Basin Variable-Flow Rotary Spray Nozzle Water Collection System

Counter Flow Cooling Towers

SERIES COOLING TOWER SINGLE-CELL UP TO 1500HRT COOLING CAPACITY

All-Fiberglass. Cooling Towers. The. HFC Series. High Performance & Quality with Maximum Durability CLOSED CIRCUIT FLUID COOLER

PROVEN PERFORMANCE RELIABILITY EASY INSTALLATION

SERIES COOLING TOWER SINGLE-CELL UP TO 1700HRT COOLING CAPACITY

SERIES COOLING TOWER. High Performance Counterflow Type SINGLE-CELL UP TO 1500HRT COOLING CAPACITY ENERGY CONSERVATION SPACE SAVING DESIGN FLEXIBILITY

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

SERIES COOLING TOWER SINGLE-CELL UP TO 1500HRT COOLING CAPACITY

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

SERIES COOLING TOWER. MULTI-CELL HRT COOLING CAPACITY Modular Design Crossflow Type LOW NOISE SUPER LOW NOISE ENERGY SAVING SUPER LOW NOISE

LITERS PER MINUTE GALLONS PER MINUTE

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

Climas y Proyectos Leyco, S.A. de C.V.

Recold JW Series. Lenntech. Tel Fax ENGINEERING DATA AND SPECIFICATIONS

EC-S SERIES COOLING TOWER. High Performance Counterflow Type SINGLE-CELL UP TO 1250HRT COOLING CAPACITY

GPC SERIES CROSSFLOW FRP COOLING TOWER

Pump Specifications FL100 Series Submersible Effluent Pump

Pump Specifications FL150 Series Submersible Effluent Pump

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Engineering Brochure. T-Model Cooling Towers A Manufacturer for 40 Years! The MEMBER

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

GD/GDS SERIES COUNTERFLOW COOLING TOWER MEMBER

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

Engineering Brochure. T-Model Cooling Towers A Manufacturer for 42 Years MEMBER

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

SECTION HVAC AIR CLEANING DEVICES

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

4400JF (120V) Aerating Fountain Specifications

Z-TECH FAN Z-TECH FAN WITH Z-CHILL. Features & SPECIFICATIONS

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Introduction to Johnson Controls Dampers

FreezeFree TM Nitro Anti-Icing System GENERAL SPECIFICATIONS

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

Self-Operating Temperature Regulators

Z-Tech Fan. Features & specifications. page 1 of 13.

NH 3. Evaporator. Ammonia Applications Tons MANP

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Engineering Data. Series V Closed Circuit Cooling Towers. VFL Engineering Data...1. VF1 Engineering Data...3

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SINGLE DUCT TERMINAL UNITS

Section J Air Control Nozzles

Square Inline Fans with Multi-Directional Discharge

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

High Performance Axial Fans

Centrifugal Filtered Supply Roof Blowers

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

DC MOTORS NEMA FRAME SCR RATED

Series: GA6-1½, GA6-2, GA7-1¼, GA7-1½

TYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15

M-B Companies, Inc. Specification. Model 245. Self Propelled Intermediate Striper. High Pressure Airless. Options. Revised September 27, 2006

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

IDCF Evaporative Condensers

SECTION AIR TERMINAL UNITS

Low Silhouette Power Roof Ventilator Propeller

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

ROGERS MACHINERY COMPANY, INC

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

BACnet MS/TP Networking Flow Balancing Control Valves

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

8400JF (240V Single Phase) Aerating Fountain Specifications

WAC Air Curtains Technical Guide

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

VXI Closed circuit cooling towers

Built For Work. THREE-PHASE PUMPS

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Heating Cable. Description

BYV Series Butterfly Valve Product Guide FLOW CONTROL

SECTION AXIAL HVAC FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Transcription:

TTXLSERIES Technical Reference Guide

TTXL SERIES FEATURES: The TTXL Series forced-draft, counter-flow cooling tower delivers reliable thermal performance in both constant and variable heat load applications. Its modular design enables easy interconnectability to create virtually any size cooling tower and quickly accommodates future expansion of cooling tower capacity. Unique Design Features Include: Fully Enclosed Flow-Thru Basin Variable-Flow Rotary Spray Nozzle Water Collection System Bottom Mounted s 2

Water Collection System TTXL s patented Water Collection System serves as an efficient collection chamber and conduit for channeling waterflow into the tower s Flow-Thru Basin. Its unique shape aerodynamically moves inlet air into the fill media while effectively providing a leak free barrier protecting tower mechanicals. Variable-Flow Rotary Spray Nozzle The patented Variable-Flow Rotary Spray Nozzle delivers even fill coverage across a broad range of system flows from 0 to 300 gpm per nozzle (.3 to 1.9 lps) at low pressures from.5 to 1.5 psi (3.5 to.3 kpa). The nozzle requires less pressure to operate than a conventional nozzle, is virtually maintenance free, and dramatically improves tower performance. Flow-Thru Basin Unlike the low velocity cold-water settling basins common to conventional cooling tower designs, the TTXL tower incorporates a patented perimeter box beam which uniquely serves as both the cold water reservoir and provides the base structural component of the module. High water velocities in the basin beams continually scrub the walls and floor of the basin to eliminate the build-up of sediment and potentially bio-hazardous material a common problem in conventional designs. Four access ports are provided for easy inspection. Use of a lateral spray pattern allows the nozzle to be positioned just one inch off the fill material, saving several feet of pump head. The nozzle s turbine-driven rotor spins on a water bearing that keeps the nozzle parts from wearing, as well as provides the needed agitation to ensure virtually clog-free service. The rotary turbine produces a larger water droplet than conventional nozzles and thereby reduces drift loading on the drift eliminators for the lowest drift loss coefficient of any cooling tower. NOZZLE SPRAY DISTANCE VERSUS FLOW % DESIGN SPRAY DISTANCE 0 0 0 0 0 20 0 Tower Tech Rotary Spray Nozzle Fixed Orifice Nozzle 02 0 0 0 0 0 0 The chart demonstrates the constancy in spray pattern coverage at varying flow rates using the Rotary Spray Nozzle. The nozzle orifice is shaped to provide an even square spray pattern, thereby uniformly wetting the entire tower s fill. This improves tower performance and reduces the likelihood of scaling due to the occurrence of dry regions within the fill. Variable-flow capability stems from the unique spring-actuated orifice which allows the nozzle to automatically adjust its pattern to changes in the flow rate, significantly reducing the down turn in performance observed with conventional nozzle designs. While conventional towers require a reduction in cell usage when system flow decreases, TTXL technology permits this reduced flow to be evenly distributed over all available fill area. This results in maximizing cooling capacity and energy efficiency under partial load duties. % NOZZLE DESIGN FLOW 3

Fill & Drift Eliminators Motors / s / Shrouds TTXL Series Modular Cooling Towers shipped after October 20 have Baldor direct-drive motors. 0Hz 0oC motors are available in various voltages at 3.0HP, 5.0HP and 7.5HP. 0Hz 50oC and 50Hz 0oC motors are available in various voltages at 2.2kW (3.0HP), 3.7kW (5.0HP) and 5.kW (7.5HP). 50Hz 50oC motors are available in various voltages at 2.9kW (.0HP) and.5kw (.0HP). All standard Baldor motors have a 2T Series size frame, are TEAO (Totally Enclosed Air Over), L (0,000 hour) sealed bearings, and are inverter ready. 0 Hz motors have a nominal RPM of 0. 50 Hz motors have a nominal RPM of 715. Tower Tech fans use high-efficiency, molded thermoplastic blades with a unique airfoil design resulting in uniform airflow, minimal turbulence, and maximized system efficiency. Adjustable-pitch blades along with lightweight, high-strength cast aluminum-silicon alloy hubs simplify field adjustments. Blade tip tolerances are quality control validated in order to ensure maximum system efficiencies. Tower Tech s stainless steel tubular motor mount provides minimum air turbulence, reduced fan noise, and long life for support of mechanical equipment. The TTXL Series precision molded fan shroud is manufactured using hand-laid fiberglass techniques. It is engineered to provide a smooth air entry (optimized r/d) and approach velocity. The heavy-duty fiberglass shroud is lightweight and will resist corrosion indefinitely. TTXL Series cooling towers are equipped with rigid cross-corrugated, high-efficiency PVC film fill media ( mil thickness). This fill media is resistant to biological degradation and to most chemicals (inorganic alkalis or acids, as well as organics) common to cooling tower systems. Its high surface area to volume ratio provides optimum heat exchange efficiency. The TTXL tower shell may be equipped with configurations to meet any water quality demand alternative thermal capacity ratings are available from your Tower Tech design engineer. In addition to PVC, TTXL Series towers may be optionally equipped with HPVC fill suitable for use in hot water applications within a working range of 130o to 155oF (5.o to 0oC). Alternative 15 mil thickness material is also available as a specified option. TTXL Series cooling towers are equipped with low-pressure sinusoidal-wave shaped PVC drift eliminators (15 mil finished thickness). These high-efficiency cells (drift loss guaranteed not to exceed 0.000%) force the exiting airstream to make three distinct directional changes causing exiting moisture droplets to impinge and coalesce on its high surface areas. The PVC material used in the construction is virtually impervious to rot, decay, or biological attack. An ultraviolet inhibitor manufactured into the product extends the life expectancy. Materials of Construction The Tower Tech TTXL Series cooling tower structure is factory-assembled and constructed entirely of fiberglass and stainless steel hardware, which together provide a rigid shell and framework for the tower that will resist deterioration and corrosion indefinitely. There are no galvanized or wood components which may leak potentially hazardous chemicals into the environment. Walls are joined together by tongue and groove joints and are sealed by a polyurethane sealant to prevent leaks. Stainless steel fasteners employing coated threads (in wetted areas) are used to bolt the walls together and ensure leak-free operation under pressurized operating conditions.

Component Material Component Material Corner Enclosures FRP (pultruded) Sub-structure Legs FRP (pultruded) Shell/Casing FRP (pultruded) Windwall Partitions ABS (extruded) Fill Media mil PVC Modular Base Support Nylon (injection molded) Drift Eliminators 15 mil PVC Shroud Hand-laid Fiberglass Rotary Spray Nozzle HDPE & Stainless Steel Sump Box PP (rotational mold) (injection molded) Lateral Distribution ABS Inspection Ports Nylon (injection molded) Water Collection ABS (injection molded Hardware 30 Stainless Steel System & extruded) Header Inlet PVC (injection molded) Support 30 Stainless Steel Where FRP = Fiber-glass Reinforced, plastic Pultrusion; PVC = Poly Vinyl Chloride; HDPE = High Density Poly-Ethylene; ABS=Acrylonitrile, 1,3 Butadiene, and Styrene Copolymer, Flame Retardant; PP = Poly-Propylene. Weights and Dimensions TTXL Model Weights in Lbs. (kg) Dimensions per Illustration Below a Shipping Operating A B C D E F G H (cm) i219xx 5,25 (2,379) 9,09 (,30) 7'-00" (213.) 3'-0 (.7) '-01" (307.3) 1'-0" (0.) '-00" (1.9) '-00" (.9) 17'-00" (51.2) 13'-0 (11.5) i319xx 7,00 (3,19) 13, (5,95) 7'-00" (213.) 3'-0 (.7) '-01" (307.3) 1'-0" (0.) '-00" (1.9) '-00" (.9) 17'-00" (51.2) 19'-03" (5.7) i19xx,35 (,00) 1,1 (7,550) 7'-00" (213.) 3'-0 (.7) '-01" (307.3) 1'-0" (0.) '-00" (1.9) '-00" (.9) 17'-00" (51.2) 25'-00" (72.0) 019xx 7,9 (3,590) 13,75 (,22) '-00" (35.) '-00" (.9) 9'-11" (302.3) 1'-0" (0.) '-00" (.9) '-00" (.9) 17'-00" (51.2) 13'-0 (11.5) i519xx,30 (,23) 20,13 (9,1) 7'-00" (213. ) 3'-0 (.7) '-01" (307.3) 1'-0" (0.) '-00" (1.9) '-00" (.9) 17'-00" (51.2) 30'-09" (937.3) 019xx 11,2 (5,291) 19,727 (,950) '-00" (35.) '-00" (.9) 9'-11" (302.3) 1'-0" (0.) '-00" (.9) '-00" (.9) 17'-00" (51.2) 19'-03" (5.7) 019xx 15, (,993) 25,95 (11,5) '-00" (35.) '-00" (.9) 9'-11" (302.3) 1'-0" (0.) '-00" (.9) '-00" (.9) 17'-00" (51.2) 25'-00" (72.0) 19xx 19, (,9) 31,55 (1,32) '-00" (35.) '-00" (.9) 9'-11" (302.3) 1'-0" (0.) '-00" (.9) '-00" (.9) 17'-00" (51.2) 30'-09" (937.3) 19xx 22,9 (,395) 37,23 (17,070) '-00" (35.) '-00" (.9) 9'-11" (302.3) 1'-0" (0.) b '-00" (.9) 17'-00" (51.2) 3'-0 (1,1.5) a b Dimensions are approximate and should not be used for construction purposes. Dimension F may be 1'-00" (30.5 cm), '-00" (1.9 cm), '-00" (.9 cm), '-00" (23. cm), '-00" (30. cm), or '-00" (35. cm) depending on project requirements. '-00" (35. cm) may be specified with prior approval of Tower Tech engineeing manager only. Dimension F on drawing below is '-00" (.9 cm). TTXL-19xx requires two sumps. See TTXL-19xx drawings on Tower Tech website. 5

Engineering Data 0 Hz, 0º C. Model TTXL i21930 i21950 i21975 No. s 2 2.2. 3.0 3.7 7. 5.0.0 5. 11.2 7.5 15.0 i31930 2.2. 3.0.0 9.0 i31950 3 3.7 11.1 5.0 15.0 Volts 200.1 2.2 13.3 2. 230 11.2 22..2 2.3 0 5. 11.2.2.3 575.5 9.0 5.2. 200 20.0 0.0 22.0.0 230 1. 33.2 1.3 3.5 0.3 1. 9.2 1. 575.7 13. 7.7 15. 200 30.0 0.0 33.0.0 230 2. 9.2 27.7 55.3 0.3 2. 13. 27.5 575.3 20. 11. 22. 200.1 3.3 13.3 39.9 230 11.2 33..2 3.5 0 5. 1..2 1.3 575.5 13.5 5.2 15.5 200 20.0 0.0 22.0.0 230 1. 9. 1.3 5. 0.3 2.9 9.2 27. 575.7 20.1 7.7 23.1 200 30.0 90.0 33.0 99.0 SFA (MMC) / a SFA (MMC) / a Eff'y b RPM S.F. 230 2. 73. 27.7 2.9 i31975 5. 1. 7.5 22.5 1.5% 50 0.3 3.9 13. 1.3 i1930 2.2. 3.0 i1950 3.7 1. 5.0 i1975 5. 01930 2.2 01950 22.. 3.7 1. 5.0 575.3 30.9 11. 3.2 200.1. 13.3 53.2 230 11.2..2. 0 5. 22..2 2. 575.5 1.0 5.2 20.7 200 20.0 0.0 22.0.0 230 1.. 1.3 73.0 0.3 33.2 9.2 3.7 575.7 2. 7.7 30. 200 30.0 0.0 33.0 132.0 230 2. 9. 27.7 1.5 7.5 30.0 1.5% 0.3 9.2 13. 55.1 575.3 1.2 11. 5. 200.1. 13.3 53.2 230 11.2..2. 3.0.0.0% 0 5. 22..2 2. 575.5 1.0 5.2 20.7 200 20.0 0.0 22.0.0 230 1.. 1.3 73.0 0.3 33.2 9.2 3.7 575.7 2. 7.7 30. 200 30.0 0.0 33.0 132.0 230 2. 9. 27.7 1.5 01975 5. 22. 7.5 30.0 1.5% 50 0.3 9.2 13. 55.1 i51930 2.2 11 3.0 i51950 5 3.7 1.5 5.0 i51975 5. 2 7.5.0 20.0 20.0 15.0 25.0 37.5 575.3 1.2 11. 5. 200.1 0.5 13.3 9.5 230 11.2 5.0.2 0. 0 5. 2.0.2 31.9 575.5 22.5 5.2 25.0 200 20.0 92.5 22.0. 230 1. 3.0 1.3 91.3 0.3 1.5 9.2 5. 575.7 33.5 7.7 3.5 200 30.0 132.5 33.0 152. 230 2. 3.0 27.7 13.1 0.3 1.5 13.. 575.3 51.5 11. 57.0.0% 5 5.5% 55 1.5% 50.0%.0% 5 5.5% 55 5.5% 5.5% 5.5% 1.5% 5 55 50 5 55.0% 5 55 50 Inlet " " " " Connections c Outlet " " " " " Makeup 1" FNPT (25mm) 1" FNPT (25mm) Overflow " (0mm) " (0mm) Engineering Data 0 Hz, 0º C. Continued on Page

Engineering Data 0 Hz, 0º C. Model TTXL No. s 01930 2.2 13.2 3.0 1.0 Volts 200.1 72. 13.3 79.9 230 11.2 7.2.2 73.0 0 5. 33..2 37.0 575.5 27.0 5.2 31.0 SFA (MMC) / a SFA (MMC) / a Eff'y b RPM S.F. 200 20.0 0.0 22.0 132.0 230 1. 99. 1.3 9.5 01950 3.7 22.2 5.0 30.0 5.5% 55 0.3 9. 9.2 55.1 01975 575.7 0.2 7.7.2 200 30.0.0 33.0 19.0 230 2. 17. 27.7 15. 0.3 73. 13. 2.1 575.3 1. 11.. 200.1 9. 13.3.5 230 11.2 9..2 97.3 01930 2.2 17. 3.0 2.0.0% 0 5...2 9.3 01950 3.7 29. 5.0 01975 5. 1930 2.2 575.5 3.0 5.2 1. 200 20.0 10.0 22.0 17.0 230 1. 132. 1.3 1.0 0.3. 9.2 73.5 575.7 53. 7.7 1. 200 30.0 20.0 33.0 2.0 230 2. 19. 27.7 221.0 7.5 0.0 1.5% 50 0.3 9. 13. 1.1 575.3 2. 11. 91.2 200.1 1.0 13.3 133.1 230 11.2 1.0.2 1. 3.0 30.0.0% 0 5. 5.0.2 1. 575.5 5.0 5.2 51. 200 20.0 200.0 22.0 220.0 230 1. 1.0 1.3.5 1950 3.7 37 5.0 50.0 5.5% 0.3 3.0 9.2 91. 575.7 7.0 7.7 77.1 200 30.0 25.0 33.0 30. 230 2. 2.0 27.7 27.3 1975 5. 5 7.5 75.0 1.5% 50 0.3 3.0 13. 137. 1930 2.2 575.3 3.0 11. 11.0 200.1 15.2 13.3 17.0 230 11.2 13..2 15.9 0 5. 7.2.2 7.1 575.5 5.0 5.2 2.1 200 20.0 220.0 22.0 255.3 230 1. 199.2 1.3 219.0 1950 3.7. 5.0 0.0 5.5% 0.3 99. 9.2.9 1975 5. 33. 7.5 5.0. 22 2. 3.0 0.0 3.0 5. 7.2 7.5 90.0 575.7 0. 7.7 92.5 200 30.0 31.0 33.0 35.7 230 2. 295.2 27.7 331.5 0.3 17. 13. 15.2 575.3 3. 11. 13..0% 5 1.5% 50 5.5%.0% 5 55 5 55 5 55 1.5% 50 Inlet " " " " Connections c Outlet " 1" (350mm) 1" (350mm) " x 2 d (300mm x 2) Makeup Overflow a b c d Baldor motor data. SFA (MMC) refers to Service Factor Amps (Maximum Motor Current). VFD should be sized for SFA (MMC). Rating is NEMA nominal efficiency. Standard motors, TEAO severe duty, direct drive, with L 0,000 hour sealed bearings, inverter ready, with quantum shield wiring, class "H" insulation (minimum). Metric dimensions approximate. TTXL- requires two sump containers. See TTXL- drawings for details. 7

Engineering Data Model TTXL No. s Volts SFA (MMC) / a SFA (MMC) / a Eff'y b RPM S.F. i21930 2.2. 3.0.0 30.7 13. 7.3 1..0% 5 0 5. 11.2.2.3 i21950 2 3.7 7. 5.0.0 30.1 20.2 11.3 22. 5.5% 0.3 1. 9.2 1. i21975 i31930 i31950 3 5. 11.2 11.1 7.5 30 15.0 30.0 1.7 33. 0.3 2. 13. 27.5 30.7 20.1 7.3 21.9 0 5. 1..2 1.3 30.1 30.3 11.3 33.9 0.3 2.9 9.2 27. i31975 5. 1. 7.5 22.5 30 15.0 5.0 1.7 50.1 1.5% 0.3 3.9 13. 1. i1930. 30.7 2. 7.3 29.2 0 5. 22..2 2. i1950 3.7 1. 5.0 20.0 30.1 0. 11.3 5.2 5.5% 55 0.3 33.2 9.2 3. i1975 22. 30 15.0 0.0 1.7. 0.3 9.2 13. 55.2 01930 2.2. 3.0.0 30.7 2. 7.3 29.2.0% 5 0 5. 22..2 2. 01950 01975 i51930 i51950 i51975 01950 5 3.7 1. 5.0 20.0 5. 2.2 3.7 01930 2.2 13.2 2.2 3.7 2.2 5. 7.5 3.0 5. 2.0 7.5 37.5 3.7. 22. 11.0 1.5 22.2 3.0 5.0 3.0 7.5 5.0 3.0 5.0 15.0 9.0 15.0.0 30.0 30.0 15.0 25.0 1.0 30.0 30.1 0. 11.3 5.2 0.3 33.2 9.2 3. 30 15.0 0.0 1.7. 0.3 9.2 13. 55.2 30.7 33.5 7.3 3.5 0 5. 2.0.2 32.5 30.1 50.5 11.3 5.5 0.3 1.5 9.2 30 15.0 75.0 1.7 3.5 0.3 1.5 13. 9.0 30.7 0.2 7.3 3. 0 5. 33..2 37.2 30.1 0. 11.3 7. 0.3 9. 9.2 55.2 1.5% 01975 5. 33. 7.5 5.0 30 15.0 90.0 1.7 0.2 1.5% 50 0.3 73. 13. 2. 01930 2.2 17. 3.0 2.0 30.7 53. 7.3 5..0% 5 0 5...2 9. 01950 3.7 29. 5.0 0.0 30.1 0. 11.3 90. 5.5% 55 0.3. 9.2 73. 01975 5.. 7.5 0.0 30 15.0 0.0 1.7 133. 1.5% 50 0.3 9. 13. 1. 55 50.0% 5 5.5% 55 50.0% 5 1.5% 50 5.5% 55 1.5% 50.0% 5 5.5% 55 1.5% 50.0% 5 5.5% 55 Inlet " " " " " " Connections c Outlet " " " " " " 1" (350mm) 0 Hz, 50º C. Makeup 1" FNPT (25mm) 1" FNPT (25mm) Overflow " (0mm) " (0mm) Engineering Data 0 Hz, 50º C. Continued on Page

Engineering Data 0 Hz, 50º C. Model TTXL 1930 No. s 2.2 22.0 3.0 30.0 Volts 30.7 7.0 7.3 73.0 0 5. 5.0.2 2.0 SFA (MMC) / a SFA (MMC) / a Eff'y b RPM S.F..0% 5 Inlet Connections c Outlet Makeup Overflow 1950 3.7 37.0 5.0 50.0 30.1 1.0 11.3 113.0 0.3 3.0 9.2 92.0 5.5% 55 " 1" (350mm) 1975 5. 5.0 7.5 75.0 30 15.0 150.0 1.7 17.0 0.3 3.0 13. 13.0 1.5% 50 1930 2.2 2. 3.0 3.0 30.7 0. 7.3 7. 0 5. 7.2.2 7..0% 5 1950 3.7. 5.0 0.0 30.1 1.2 11.3 135. 0.3 99. 9.2 1. 5.5% 55 " " x 2 d (300mm x 2) 1975 5. 7.2 7.5 90.0 30 15.0.0 1.7 200. 0.3 17. 13. 15. 1.5% 50 a b c d Baldor motor data. SFA (MMC) refers to Service Factor Amps (Maximum Motor Current). VFD should be sized for SFA (MMC). Rating is NEMA nominal efficiency. Standard motors, TEAO severe duty, direct drive, with L 0,000 hour sealed bearings, inverter ready, with quantum shield wiring, class "H" insulation (minimum). Metric dimensions approximate. TTXL- requires two sump containers. See TTXL- drawings for details. 9

Engineering Data Model TTXL No. s i21922 2.2. 3.0.0 i21937 2 3.7 i2195 5. i31922 2.2 i31937 3 7. 5.0 11.2 7.5 15.0 3.0 9.0 Volts SFA (MMC) / a 190. 2. 13. 27.2 30.2.. 13. 190 1. 37. 20.3 0. 30 9. 1..1 20.2 190 2. 57.2 33. 7.2 30 1.3 2. 1.3 32. 190. 37.2 13. 0. 30.2 1.. 20. SFA (MMC) / a Eff'y b RPM S.F. 3.7 11.1 5.0 15.0 190 1. 5. 20.3 0.9 5.5% 1. 30 9. 2.2.1 30.3 i3195 5. 1. 7.5 22.5 i1922 2.2. 3.0.0 190 2. 5. 33. 0. 30 1.3 2.9 1.3.9 190. 9. 13. 5. 30.2 2.. 27.2 i1937 3.7 1. 5.0 20.0 190 1. 75.2 20.3 1.2 5.5% 1. 30 9. 37..1 0. i195 01922 5. 22. 7.5 30.0 2.2. 3.0.0 190 2. 11. 33. 13. 30 1.3 57.2 1.3 5.2 190. 9. 13. 5. 30.2 2.. 27.2 01937 3.7 1. 5.0 20.0 190 1. 75.2 20.3 1.2 5.5% 1. 30 9. 37..1 0. 0195 5. 22. 7.5 30.0 i51922 2.2 11.0 3.0 15.0 190 2. 11. 33. 13. 30 1.3 57.2 1.3 5.2 190. 2.0 13..0 30.2 31.0. 3.0 i51937 5 3.7 1.5 5.0 25.0 190 1. 9.0 20.3 1.5 5.5% 1. 30 9. 7.0.1 50.5 i5195 5. 2.0 7.5 37.5 01922 2.2 13.2 3.0 1.0 01937 3.7 22.2 5.0 30.0 0195 5. 33. 01937 0195 5.. Motors. 01922 2.2 17. 3.0 3.7 29. 5.0 7.5 5.0 7.5.0 2.0 190 2. 13.0 33. 1.0 30 1.3 71.5 1.3 1.5 190. 7. 13. 1. 30.2 37.2. 0. 190 1. 1. 20.3 1. 30 9. 5..1 0. 190 2. 171. 33. 201. 30 1.3 5. 1.3 97. 190. 99.2 13.. 30.2 9.. 5. 0.0 190 1. 150. 20.3. 5.5% 1. 30 9. 75.2.1 0. 0.0 3 Phase, 50 Hz, 0 C., 190V or 30V 190 2. 22. 33. 2. 30 1.3 11. 1.3 130..0% 5.5% 1.5%.0% 1.5%.0% 1.5%.0% 1.5%.0% 1.5%.0% 5.5% 1.5%.0% 1.5% 720 720 720 720 720 720 720 1. 1. Inlet " " " " " " Outlet 50 Hz, 0º C. Connections c " " " " " " 1" (350mm) Makeup 1" FNPT (25mm) 1" FNPT (25mm) Overflow " (0mm) " (0mm) Engineering Data 50 Hz, 0º C. Continued on Page

Engineering Data 50 Hz, 0º C. a b c d Model TTXL No. s 1922 2.2 22.0 3.0 30.0 1937 3.7 37.0 195 5. 5.0 7.5 75.0 1922 2.2 2. 3.0 3.0 1937 3.7 Volts 190..0 13. 13.0 30.2 2.0..0 SFA (MMC) / a SFA (MMC) / a Eff'y b RPM S.F. 5.0 50.0 190 1. 1.0 20.3 203.0 5.5% 30 9. 9.0.1 1.0 190 2. 2.0 33. 33.0 30 1.3 13.0 1.3 13.0 190. 1. 13. 13.2 30.2 7.. 1. 190 1. 225. 20.3 23. 30 9. 1..1 1.2 190 2. 33.2 33. 03.2 30 1.3 171. 1.3 195. Baldor motor data. SFA (MMC) refers to Service Factor Amps (Maximum Motor Current). VFD should be sized for SFA (MMC). Rating is NEMA nominal efficiency. Standard motors, TEAO severe duty, direct drive, with L 0,000 hour sealed bearings, inverter ready, with quantum shield wiring, class "H" insulation (minimum). Metric dimensions approximate. Motors. 5.0.0 195 5. 7.2 7.5 90.0 3 Phase, 50 Hz, 0 C., 190V or 30V TTXL- requires two sump containers. See TTXL- drawings for details..0% 1.5%.0% 5.5% 1.5% 720 720 1. 1. Inlet " " Connections c Outlet 1" (350mm) " x 2 d (300mm x 2) Makeup Overflow 11

Engineering Data Model TTXL No. s i21929 2.9 5..0.0 i2195 i195 01929 i51929 i5195 Volts 190 1.2 32. 17. 35. 30.1 1.2.9 17. 190 2.0.0 2.9 53. 30.0 2.0 13. 2. 190 1.2. 17. 53. 30.1 2.3.9 2.7 190 2.0 72.0 2.9 0.7 30.0 3.0 13. 0.2 190 1.2. 17. 71.2 30.1 32..9 35. 190 2.0 9.0 2.9 7. 30.0.0 13. 53. 190 1.2. 17. 71.2 30.1 32..9 35. 190 2.0 9.0 2.9 7. 30.0.0 13. 53. 190 1.2 1.0 17. 9.0 30.1 0.5.9.5 190 2.0 0.0 2.9 13.5 30.0 0.0 13. 7.0 SFA (MMC) / a SFA (MMC) / a Eff'y b RPM S.F. 01929 2.9 17..0 2.0 190 1.2 97.2 17.. 5.5% 7 30.1..9 53. 0195.5 27.0.0 3.0 190 2.0 1.0 2.9 11. 1.5% 715 30.0 72.0 13. 0. 01929 195.5 5.0.0 0.0 1929 2 3 5 1929 2.9.5 9.0.0 i31929 2.9.7.5 2.9 2.9.5 2.9 1.0 11. 1.5 22.5 23.2 29.0.0.0.0.0.0.0.0.0 i3195.5 13.5.0 1.0 i1929 2.9 11..0 1.0 2.0 1.0 0195.5 1.0.0 2.0 20.0 30.0 32.0 0195.5 3.0.0.0.0 0.0 2.9 3..0.0 195.5 5.0.0 72.0 190 1.2 9. 17.. 30.1..9 71.2 190 2.0 192.0 2.9 215.2 30.0 9.0 13. 7.2 190 1.2.0 17. 17.0 30.1 1.0.9 9.0 190 2.0 20.0 2.9 29.0 30.0 0.0 13. 13.0 190 1.2 19. 17. 213. 30.1 97.2.9. 190 2.0 2.0 2.9 322. 30.0 1.0 13. 10. 5.5% 1.5% 5.5% 1.5% 5.5% 7 1.5% 5.5% 1.5% 5.5% 1.5% 5.5% 5.5% 1.5% 7 715 7 715 715 7 715 7 715 7 1.5% 715 7 715 5.5% 7 1.5% 715 Inlet " " " " " " " " Connections c Outlet " " " " " " 1" (350mm) 1" (350mm) " x 2 d (300mm x 2) Makeup 1" FNPT (25mm) 1" FNPT (25mm) Overflow " (0mm) " (0mm) a b c d Baldor motor data. SFA (MMC) refers to Service Factor Amps (Maximum Motor Current). VFD should be sized for SFA (MMC). Rating is NEMA nominal efficiency. Standard motors, TEAO severe duty, direct drive, with L 0,000 hour sealed bearings, inverter ready, with quantum shield wiring, class "H" insulation (minimum). Metric dimensions approximate. TTXL- requires two sump containers. See TTXL- drawings for details.

13

1

15

Sub-Structure/Multiple s % Capability Correction (3 2.2 kw Models) Inlet Ht (ft) i21930 i31930 i1930 01930 % Capability Correction Number of s 1 2 3 5 7 9 0.99 0.993 0.9 0.9 0.91 0.97 0.97 0.973 0.972 0.970 1.000 0.99 0.99 0.99 0.993 0.991 0.990 0.990 0.99 0.9 1.000 1.000 0.99 0.997 0.997 0.99 0.995 0.995 0.99 0.99 1.001 1.001 0.999 0.999 0.99 0.99 0.99 0.997 0.997 0.997 1.002 1.001 1.001 1.000 0.999 0.999 0.999 0.999 0.99 0.99 0.99 0.991 0.95 0.97 0.973 0.97 0.972 0.959 0.95 0.953 1.000 0.997 0.99 0.992 0.99 0.9 0.95 0.93 0.91 0.90 1.000 0.999 0.997 0.995 0.995 0.993 0.992 0.991 0.990 0.990 1.001 1.000 0.999 0.99 0.997 0.99 0.995 0.995 0.99 0.99 1.001 1.001 0.999 0.999 0.99 0.99 0.997 0.997 0.997 0.99 0.997 0.991 0.97 0.95 0.93 0.92 0.91 0.90 0.979 0.97 1.000 0.99 0.99 0.995 0.99 0.993 0.993 0.992 0.992 0.992 1.001 1.000 0.999 0.99 0.99 0.99 0.997 0.997 0.997 0.997 1.002 1.001 1.001 1.000 0.999 0.999 0.999 0.999 0.999 0.999 1.002 1.002 1.001 1.001 1.001 1.001 1.001 1.001 1.000 1.000 0.997 0.991 0.97 0.95 0.93 0.92 0.91 0.90 0.979 0.97 1.000 0.99 0.99 0.995 0.99 0.993 0.993 0.992 0.992 0.992 1.001 1.000 0.999 0.99 0.99 0.99 0.997 0.997 0.997 0.997 1.002 1.001 1.001 1.000 0.999 0.999 0.999 0.999 0.999 0.999 1.002 1.002 1.001 1.001 1.001 1.001 1.001 1.001 1.000 1.000 i51930 01930 01930 0.99 0.99 0.97 0.9 0.95 0.9 0.97 0.932 0.92 0.919 1.000 0.99 0.992 0.97 0.92 0.97 0.97 0.970 0.9 0.9 1.001 1.999 0.99 0.99 0.991 0.9 0.9 0.9 0.92 0.90 1.002 1.000 0.99 0.99 0.995 0.993 0.992 0.991 0.99 0.9 1.002 1.000 1.000 0.99 0.997 0.99 0.995 0.99 0.993 0.992 0.99 0.97 0.90 0.975 0.971 0.9 0.9 0.9 0.92 0.91 1.000 0.99 0.993 0.991 0.99 0.9 0.97 0.9 0.95 0.9 1.001 0.999 0.997 0.99 0.99 0.995 0.99 0.99 0.993 0.993 1.002 1.001 1.000 0.999 0.99 0.99 0.99 0.997 0.997 0.997 1.003 1.002 1.001 1.001 1.000 0.999 0.999 0.999 0.999 0.999 0.995 0.93 0.97 0.9 0.90 0.955 0.951 0.97 0.9 0.92 1.000 0.99 0.990 0.9 0.9 0.91 0.979 0.97 0.97 0.975 1.002 0.99 0.99 0.99 0.992 0.991 0.990 0.99 0.9 0.97 1.002 1.001 0.999 0.99 0.99 0.99 0.995 0.99 0.99 0.99 1.003 1.002 1.001 0.999 0.999 0.99 0.99 0.997 0.997 0.99 1930 1930 0.995 0.91 0.9 0.95 0.99 0.92 0.93 0.931 0.927 0.923 1.000 0.99 0.9 0.93 0.979 0.975 0.973 0.970 0.9 0.9 1.002 0.99 0.995 0.992 0.990 0.9 0.9 0.95 0.93 0.92 1.003 1.001 0.99 0.99 0.995 0.993 0.992 0.992 0.990 0.990 1.00 1.002 1.000 0.999 0.99 0.997 0.99 0.995 0.995 0.99 0.99 0.97 0.92 0.99 0.93 0.929 0.21 0.915 0.909 0.90 1.000 0.992 0.95 0.979 0.973 0.99 0.95 0.91 0.959 0.95 1.002 0.99 0.99 0.990 0.97 0.9 0.92 0.90 0.979 0.97 1.003 1.000 0.997 0.995 0.993 0.991 0.990 0.9 0.97 0.9 1.003 1.001 0.999 0.99 0.99 0.995 0.99 0.993 0.992 0.992 1

Sub-Structure/Multiple s % Capability Correction ( & 5 2.9 & 3.7 kw Models) Inlet Ht (ft) i21950 i31950 i1950 01950 % Capability Correction Number of s 1 2 3 5 7 9 0.99 0.993 0.99 0.95 0.91 0.979 0.97 0.97 0.973 0.971 1.000 0.99 0.99 0.99 0.993 0.992 0.991 0.990 0.99 0.99 1.001 0.999 0.99 0.99 0.997 0.99 0.995 0.995 0.995 0.99 1.001 1.000 1.000 0.999 0.999 0.99 0.99 0.997 0.997 0.997 1.001 1.001 1.000 1.000 1.000 0.999 0.999 0.999 0.999 0.999 0.99 0.992 0.95 0.979 0.973 0.99 0.95 0.91 0.95 0.95 1.000 0.997 0.99 0.992 0.99 0.97 0.95 0.9 0.92 0.91 1.000 0.999 0.997 0.99 0.995 0.993 0.992 0.992 0.991 0.990 1.001 1.000 0.999 0.99 0.997 0.99 0.99 0.995 0.995 0.99 1.001 1.001 1.000 1.000 0.999 0.99 0.99 0.997 0.997 0.997 0.997 0.991 0.9 0.95 0.93 0.92 0.91 0.90 0.979 0.979 1.000 0.99 0.99 0.995 0.99 0.993 0.993 0.993 0.992 0.992 1.001 1.000 0.999 0.99 0.99 0.99 0.997 0.997 0.997 0.997 1.002 1.001 1.000 1.000 1.000 1.000 1.000 1.000 0.999 0.999 1.002 1.001 1.001 1.001 1.001 1.000 1.000 1.000 1.000 1.000 0.997 0.991 0.9 0.95 0.93 0.92 0.91 0.90 0.979 0.979 1.000 0.99 0.99 0.995 0.99 0.993 0.993 0.993 0.992 0.992 1.001 1.000 0.999 0.99 0.99 0.99 0.997 0.997 0.997 0.997 1.002 1.001 1.000 1.000 1.000 1.000 1.000 1.000 0.999 0.999 1.002 1.001 1.001 1.001 1.001 1.000 1.000 1.000 1.000 1.000 i51950 0.99 0.99 0.979 0.99 0.959 0.950 0.92 0.93 0.92 0.922 1.000 0.99 0.991 0.97 0.93 0.97 0.97 0.971 0.9 0.95 1.001 0.999 0.99 0.99 0.991 0.99 0.97 0.9 0.93 0.91 1.002 1.000 0.99 0.99 0.995 0.993 0.992 0.991 0.99 0.9 1.002 1.000 1.000 0.99 0.997 0.99 0.995 0.99 0.993 0.992 01950 01950 0.99 0.9 0.91 0.97 0.972 0.99 0.97 0.95 0.93 0.93 1.000 0.99 0.99 0.991 0.99 0.9 0.97 0.9 0.95 0.95 1.001 1.000 0.99 0.99 0.995 0.99 0.99 0.99 0.993 0.993 1.003 1.001 1.000 0.999 0.99 0.99 0.997 0.997 0.997 0.997 1.003 1.002 1.001 1.001 1.000 1.000 0.999 0.999 0.999 0.999 0.99 0.9 0.975 0.97 0.91 0.95 0.952 0.99 0.9 0.9 1.000 0.995 0.990 0.97 0.9 0.92 0.90 0.979 0.977 0.97 1.002 0.999 0.99 0.99 0.993 0.991 0.990 0.99 0.99 0.9 1.003 1.001 0.999 0.997 0.99 0.99 0.995 0.99 0.99 0.99 1.003 1.002 1.001 0.999 0.999 0.99 0.99 0.997 0.997 0.997 1950 1950 0.99 0.91 0.99 0.959 0.950 0.9 0.93 0.933 0.929 0.92 1.000 0.99 0.99 0.9 0.90 0.97 0.973 0.971 0.99 0.97 1.002 0.99 0.99 0.992 0.990 0.99 0.97 0.95 0.9 0.93 1.003 1.001 0.99 0.99 0.995 0.993 0.992 0.992 0.991 0.990 1.003 1.002 1.000 0.99 0.997 0.997 0.99 0.995 0.995 0.99 0.99 0.97 0.93 0.950 0.93 0.930 0.922 0.915 0.9 0.905 1.000 0.992 0.95 0.979 0.97 0.99 0.95 0.92 0.959 0.95 1.002 0.997 0.99 0.990 0.97 0.9 0.91 0.979 0.97 0.97 1.003 1.000 0.997 0.995 0.993 0.991 0.990 0.9 0.97 0.9 1.003 1.001 0.999 0.99 0.99 0.995 0.99 0.993 0.992 0.992 17

Sub-Structure/Multiple s % Capability Correction ( & 7.5.5 & 5. kw Models) Inlet Ht (ft) % Capability Correction Number of s 1 2 3 5 7 9 i21975 i31975 i1975 01975 0.99 0.99 0.99 0.95 0.92 0.979 0.977 0.97 0.973 0.972 1.000 0.99 0.99 0.99 0.993 0.992 0.991 0.990 0.99 0.99 1.000 1.000 0.99 0.99 0.997 0.99 0.99 0.995 0.995 0.99 1.001 1.000 0.999 0.999 0.99 0.99 0.99 0.99 0.997 0.997 1.001 1.001 1.000 1.000 0.999 0.999 0.999 0.999 0.99 0.99 0.99 0.992 0.95 0.979 0.97 0.99 0.95 0.91 0.95 0.95 1.000 0.99 0.995 0.992 0.990 0.9 0.95 0.9 0.93 0.91 1.000 0.999 0.99 0.99 0.995 0.99 0.993 0.91 0.991 0.990 1.001 1.000 0.999 0.99 0.997 0.997 0.99 0.995 0.995 0.995 1.001 1.000 1.000 0.999 0.999 0.99 0.99 0.997 0.997 0.997 0.997 0.991 0.9 0.9 0.9 0.93 0.91 0.90 0.90 0.979 1.000 0.99 0.99 0.995 0.99 0.99 0.993 0.993 0.993 0.992 1.001 1.000 0.999 0.99 0.99 0.997 0.997 0.997 0.997 0.997 1.002 1.001 1.000 1.000 1.000 1.000 0.57 0.999 0.999 0.999 1.002 1.002 1.001 1.001 1.001 1.001 1.001 1.000 1.000 1.000 0.997 0.991 0.9 0.9 0.9 0.93 0.91 0.90 0.90 0.979 1.000 0.99 0.99 0.995 0.99 0.99 0.993 0.993 0.993 0.992 1.001 1.000 0.999 0.99 0.99 0.997 0.997 0.997 0.997 0.997 1.002 1.001 1.000 1.000 1.000 1.000 0.57 0.999 0.999 0.999 1.002 1.002 1.001 1.001 1.001 1.001 1.001 1.000 1.000 1.000 i51975 0.99 0.99 0.979 0.99 0.90 0.951 0.92 0.935 0.929 0.923 1.000 0.99 0.992 0.97 0.93 0.979 0.975 0.972 0.9 0.95 1.001 0.999 0.99 0.993 0.991 0.99 0.97 0.95 0.93 0.91 1.002 1.000 0.99 0.99 0.995 0.993 0.992 0.991 0.99 0.9 1.002 1.000 1.000 0.99 0.997 0.99 0.995 0.99 0.993 0.992 01975 01975 0.99 0.9 0.91 0.977 0.973 0.971 0.9 0.9 0.9 0.9 1.000 0.997 0.99 0.991 0.990 0.9 0.9 0.97 0.9 0.95 1.002 1.000 0.99 0.997 0.99 0.995 0.995 0.99 0.99 0.993 1.002 1.001 1.000 0.999 0.99 0.99 0.997 0.997 0.997 0.997 1.003 1.002 1.001 1.000 1.000 1.000 0.999 0.999 0.999 0.999 0.995 0.9 0.975 0.9 0.92 0.957 0.953 0.950 0.97 0.95 1.000 0.995 0.991 0.97 0.9 0.92 0.90 0.979 0.977 0.97 1.002 0.99 0.99 0.995 0.993 0.991 0.991 0.99 0.99 0.9 1.002 1.000 0.999 0.99 0.997 0.99 0.995 0.99 0.99 0.99 1.003 1.001 1.000 1.000 0.999 0.99 0.99 0.99 0.997 0.997 1975 0.995 0.92 0.970 0.90 0.952 0.9 0.939 0.93 0.930 0.927 1.000 0.99 0.9 0.93 0.979 0.97 0.973 0.971 0.99 0.97 1.002 0.99 0.995 0.992 0.990 0.9 0.97 0.95 0.9 0.93 1.003 1.000 0.999 0.997 0.995 0.99 0.993 0.992 0.991 0.991 1.003 1.002 1.000 0.999 0.99 0.997 0.99 0.99 0.995 0.995 1975 0.995 0.979 0.9 0.951 0.90 0.932 0.92 0.91 0.913 0.90 1.000 0.993 0.9 0.90 0.97 0.970 0.9 0.93 0.900 0.95 1.002 0.99 0.99 0.990 0.97 0.9 0.92 0.90 0.970 0.977 1.003 1.000 0.997 0.995 0.993 0.991 0.990 0.9 0.97 0.9 1.003 1.001 0.999 0.99 0.99 0.995 0.99 0.993 0.992 0.992 1

OPTIONAL EQUIPMENT Motor Pre-Wire TTXL Series Modular Cooling Towers are shipped with motors factory pre-wired to a central junction box (NEMA-X). Motors can be factory pre-wired to individual lock-out/tag-out rotary disconnect switches. Motor wiring used is Alpha brand shielded - AWG (- AWG used where Maximum Motor Current is 30 amps or higher), VFD compatible, liquid tight flexible cable. Sub-Structure Kits Each Modular Cooling Tower has a 1-foot (30.5 cm) high stub leg kit for mounting on customer furnished support structure. As an option, towers can be furnished with leg kits from feet to feet (1.9 cm to 35. cm) in height. The most common configuration uses -foot (. cm) high legs to allow convenient access to the fan inlet of the tower for inspections and maintenance. Sub-structure kits include FRP legs with integrated footpads (Nylon), angle braces (FRP), and stainless steel assembly hardware; and are shipped loose for installation at the time of delivery and tower installation. Control Panels Panels are high quality, UL rated, NEMA enclosures (epoxy painted steel) equipped for single-point wiring to a manual disconnect. Each control panel includes power distribution to individual motor starters with lockout disconnect, magnetic overload protection, and solid-state adjustable thermal overload protection. There is a door mounted H-O-A switch and RUN pilot light for each motor starter. Auxiliary motor starter contacts can be provided. A solid-state PLC is provided for supply water temperature control with a doormounted operator interface display panel and an RTD temperature sensor for remote mounting in the customer s tower discharge piping. Standard water temperature control is done with fan staging through the pre-programmed PLC. Variable Frequency Drives Optional water temperature control can be done with a remote mounted variable frequency drive (VFD) suitable for multiple motor operation. The VFD output is wired to the control panel disconnect switch. The output frequency of the VFD can be controlled through the pre-programmed PLC by means of a -20 ma or 0-2V analog output. If the VFD is bypassed for any reason, the PLC returns to fan staging control. Operating Tower Tech cooling tower fans through a VFD provides the tightest temperature control possible at the very lowest energy consumption. When operated with variable water flow, the combination of the VFD and the variable flow Rotary Spray Nozzle provide energy saving opportunities that no other cooling tower can match. Contact your Tower Tech sales representative for details. Basin Heaters Stainless steel electric immersion heaters are recommended when operating in low ambient temperature conditions in order to protect against basin freezing when the tower is shut down. A NEMA X control panel is provided to control up to four individual elements ( kw each). A remote temperature sensor is provided for mounting in the tower basin and the controller is preset to 5ºF (7.2ºC). All heating elements must be located within the same tower water basin as the sensing element. Threaded flanges are installed in the tower s cold water basin for mounting each heating element and the temperature sensor. The control panel must be field mounted and wired to each heating element and the temperature sensor. A power source separate from the cooling tower fans is recommended. Level Control When water level control is needed in the TTXL tower module, the standard level controller is a mechanical valve actuated through a float mounted on a short rod located in the external sump container which is attached to the terminal end of each tower module. To function correctly, the mechanical float valve requires inlet water pressure of 25 psi (or less) applied at the valve inlet. The use of a pressure reducing valve is necessary when the inlet water supply exceeds 25 psi. If a non-contact water level control is desired, a pre-engineered, self-contained ultrasonic liquid level control package is optionally available. The package consists of a continuous measuring ultrasonic device combined with a controlling relay, an LCD screen, and a stilling well mounting pipe. The stilling well pipe is mounted in the tower s equalization/overflow piping. The ultrasonic device operates on an analog -20ma circuit to the relay/lcd which sends command signals to the solenoid valve (solenoid valve not supplied). The LCD screen shows the water level and the indicator lights show whether the solenoid valve is commanded ON or OFF. 19

Seawater Applications Tower Tech modules are the best solution available for cooling with seawater. All of the structural and internal components are inert in the presence of seawater. Even 30 Stainless Steel is aggressively attacked and corroded by the chlorides in seawater. Tower Tech offers a wide selection of fouling resistant fills and a 31 Stainless Steel hardware option to assure long life and low maintenance for your operations. There will be a 5-15% thermal capacity (gpm/lps) derate depending on the salinity content of the cooling water. Contact your Tower Tech representative for solutions to match your specific application. Engineering Certifications Certified calculations are available for all models with substructures up to feet (23. cm) for seismic and wind loading in accordance with the International Building Code s most severe requirements. Sustained wind loading at 150 MPH/1 psf (21. KPH/200 KSM) for hurricane exposure and IBC seismic force factor Cs=0. x weight, category D (Ss=200, S1=150, soil class E). Tower Tech has performed extensive acoustic testing in accordance with CTI Standard ATC- using licensed Acoustical Engineers. Sound data for all Tower Tech models is available. Computer simulated site specific 3D sound modeling is also available through your Tower Tech representative. 20

The thermal performance of the TTXL Series cooling towers is certified by the Cooling Technology Institute in accordance with its standard STD-201 and has been assigned CTI certification validation number 0-17-0. This certification is your assurance that the proposed capacities accurately reflect actual cooling tower performance. CTI certification under STD-201 is limited to thermal operating conditions with entering wet bulbs between 55 F and 90 F (. C and 32.2 C), a maximum process fluid temperature of 5 F (51.7 C), a cooling range of F (2.2 C) or greater, and a cooling approach of 5 F (2. C) or greater.