Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Similar documents
Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

Ampgard The name motor applications rely on

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

W-VACi MV circuit breakers

Powering business worldwide

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Eaton Corporation An Overview Eaton Corporation. All rights reserved.

XIRIA Green, Smart, Compact solution

Unitole UP kv Primary substations Motor control centres

Dry-Type Transformers Mini-Power Centers

Unitole UP kv Primary substations Motor control centres

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Innovac SVS/08 - SVS/ kv modular switchgear

E-VAC Series Medium Voltage Vacuum Circuit Breaker

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

Xiria 24 kv Ring Main Unit

Capabilities Brochure

Motorpact Medium Voltage Motor Controller. Innovative solutions that deliver high performance and reliability

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Xiria 12 kv Ring Main Unit in IEC and ENATS design

Tradition. Technology. Innovation.

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

MP-4000 Motor Protection

Pow-R-Flex low ampere busway

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Horizontal Circuit Switchers

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

EATON Corporation David May J.C. Moots

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers

T300MVi JK OEM POWER CELLS MEDIUM VOLTAGE VACUUM CONTACTOR. Reliability in motion. Reliability in motion

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Electrical safety and reliability: Selective coordination. Protect with selective coordination

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

Eaton vacuum interruption (EVI) technology. Proven vacuum interruption technology Environmentally focused circuit protection for global innovation

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

Metal-enclosed medium-voltage power factor correction system

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Horizontal Circuit Switchers

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Critical Power Switchboards. Selection and Application Guide

Power System Solutions (PSS)

IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv Product Guide. W-VACi. for safety, reliability and performance

Flexible. Intelligent. Trendsetting.

Grounding Systems. Resistance. Resistance Grounding Systems Contents

Medium Voltage Fuses. Industry s most comprehensive medium voltage circuit protection

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION MOTOR CONTROL

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Power Break II Switchboard

Advance 27 ANSI 27 kv switchgear

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Product Guide. enclosed NEMA STARTERS

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

Metal-enclosed medium voltage power factor correction system

C1000 Series Automatic Cap Bank

Product guide. Enclosed NEMA starters. Answers for industry.

Padmount Solid Dielectric Switchgear Catalog

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

B kv T&D GAS INSULATED SWITCHGEAR

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

This small footprint makes a BIG impact

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Complete Range of Soft Start / Motor Control, Motor Protection & Control Solutions

Gas Insulated Metal-clad Switchgear, HMGS!

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Magnum IEC Low Voltage Air Circuit Breakers

Selection Guide Motor Control Device Solutions

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

SWITCHGEAR DIVISION PRODUCT PROFILES

University of Houston Master Construction Specifications Insert Project Name

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

Transcription:

Overview Brochure Integrated Power Distribution Medium Voltage Assembly Solutions

Medium voltage assembly solutions Eaton, a premier leader in manufacturing power distribution and power protection equipment in the electrical industry, offers a wide range of innovative, medium voltage assembly solutions that provide flexible options. From products that feature cutting-edge design that allow for easy access, maintenance and space-savings, to arc-resistant products that enhance safety and are environmentally responsible, Eaton s medium voltage assembly solutions provide a variety of products for every need. 2 eaton corporation Medium Voltage Assembly Solutions

Eaton offers a comprehensive range of medium voltage assembly solutions to meet the needs of virtually every application. As one of the only completely vertically integrated, diversified industrial manufacturers, Eaton designs not only the structure, but all of the components that comprise this MV equipment from steel housing and breaker compartments, to vacuum interrupters and circuit breakers, to bus systems and fuses. No other manufacturer provides such an extensive range of technologically advanced medium voltage assembly products than Eaton. Part of our complete electrical PowerChain Managemente solutions which help businesses minimize risks while realizing greater reliability, cost efficiencies, capital utilization and safety Eaton s medium voltage equipment meets all applicable standards and certifications, including: NEMA cul ANSI UBC IEC UL IEEE CSA KEMA For more than 60 years, Eaton has manufactured electrical products under brand names that include Powerware, Cutler-Hammer, Durant, Heinemann, Holec and MEM, serving the industrial, utility, light commercial, residential, IT and OEM markets worldwide. When it comes to medium voltage assembly solutions, you can trust the one name with a long history of proven performance: Eaton. eaton corporation Medium Voltage Assembly Solutions 3

Medium voltage motor control products 4 eaton corporation Medium Voltage Assembly Solutions

AMPGARD Starters As the industry leader in medium voltage motor control, Eaton s Cutler-Hammer AMPGARD starter family delivers unsurpassed flexibility, features and capabilities. With an innovative design that enables easier installation, maintenance, and long life, AMPGARD starters are ideal for a variety of industrial process applications where proper control and protection of motors and systems are paramount. AMPGARD is the first starter designed as an integrated, complete unit precisely matched to motor ratings and engineered to provide component-to-component circuitry and front accessibility of all components and terminals. Rated at 2.3 kv to 15.0 kv and up to 8000 Hp Features state-of-the-art MP3000 Microprocessor-based motor protective relay Isolated cable entry enhances safety Lighter weight contactor eases handling and maintenance Provides highest short circuit ratings in industry (8500 A for the 400 A model and 12,500 A for the 800 A model) Full coordination between fuse and contactor provides seamless protection Component-to-component design cuts the number of electrical connections in half Also available: Squirrel Cage Motor Starters Available in full or reduced voltage designs in all ratings Synchronous Motor Starters Reliable, automatic starting of synchronous motors provided by field frequency circuitry to assure application of the field at proper motor speed Motor Operator for Isolation Switch The Motor Operator allows the user to open or close the Isolation Switch at a distance of up to 25 feet from the front of the starter. One operator can be utilized for an entire lineup of Ampgard Starters, helping to ensure personnel safety eaton corporation Medium Voltage Assembly Solutions 5

AMPGARDT 7.2 kv Lineup SL Medium Voltage Vacuum Contactor AMPGARD 15 kv Starter with Incoming Cable Section Application The Cutler-Hammer AMPGARD medium voltage metal-enclosed control family from Eaton s electrical business provides control and protection of medium voltage motors and equipment rated 2300 to 13800 volts nominal/15000 volts maximum. AMPGARD control has a complete metal-enclosed offering: Full and reduced voltage starting of medium voltage motors up to 8000 hp. Reduced voltage starters include reactor, autotransformer, and soft start types SC9000 Adjustable Frequency Drive Main breaker metal-enclosed switchgear, a smaller footprint, single integrated assembly direct coupled to the AMPGARD starters and drives Integral LBS load break available as main, tie or feeder. The LBS can be supplied as fused or un-fused AMPGARD Remote Operator Available as an option for AMPGARD medium voltage motor starters, the ARO enables users to open or close the motor starter s isolation switch through the use of a pendant pushbutton station operated up to 30 feet away. Users can mount the ARO on the front of the starter, plug it into any available 120 Vac source, then easily and conveniently operate the isolation switch from outside the arc flash boundary. SL Series of Contactors Eaton s SL Series of contactors incorporate world-class Cutler-Hammer vacuum interrupters for increased safety and reliability, improved performance and reduced maintenance. The medium voltage contactors combine the highest ratings available in a cost-saving, reduced-size package that is lighter in weight and easy to install. Available in 7200 V and 15000 V models, up to 800 amperes Field adjustable coil voltages and drop-out times Longest life of any MV contactor Highest interrupt ratings in the industry Increased safety, reliability and production Improved performance, especially in dusty and corrosive environments Reduce maintenance, downtime and unit weight Quiet operation Less wattage loss High quality and long life AMPGARD 15 kv The innovative AMPGARD 15 kv medium voltage motor starter features an enhanced design that offers longer life, reduced maintenance and a smaller footprint than traditional methods. Front-accessible design can be installed against a wall Conduit area easily accommodates two 350 kcmil cables per phase Large, easily accessible low voltage panel is completely isolated from medium voltage department For motors with up to 200 full load amps 6 eaton corporation Medium Voltage Assembly Solutions

Ampgard 7.2 kv AMPGARD SC 9000 Medium Voltage Adjustable Frequency Drive Arc-Resistant Arc-Resistant AMPGARD AR Long recognized as the industry leader in medium voltage motor control, Eaton s AMPGARD product line is now available in arc-resistant models (30 ka and 50 ka) for applications requiring increased operator protection. Extensively tested and verified to meet IEEE C37.20.7 requirements for Type 2B Accessibility, AMPGARD AR incorporates the key features of traditional models, including Type SL Vacuum Contactors, complete front accessibility and top-mounted main bus. Rear arc chamber, roof flaps and plenum allow arc gasses to flow away from the operator Strengthened front doors and latches to ensure closure during a fault Insulated main bus minimizes risk of bus fault Low voltage control compartment verified to meet arc resistant requirements Adjustable Frequency Drives AMPGARD SC 9000 Offering the ultimate in reliable and flexible motor drive technology, Eaton s AMPGARD SC 9000 combines innovative technology with the proven design and construction inherent in traditional AMPGARD products. Designed for use with induction or synchronous motors at 2400 to 4160 V up to 5000 hp Smallest footprint per hp in the industry requires less space Clean and quiet operation assures minimum component usage while reducing noise pollution Modular roll-in, roll-out inverter design reduces Mean Time to Repair (MTTR) for maximum uptime and time/cost savings Encapsulated draw-out inverter with patented insulation system reduces potential for environmental contamination eaton corporation Medium Voltage Assembly Solutions 7

Medium voltage distribution products 8 eaton corporation Medium Voltage Assembly Solutions

5/15 kv Type VacClad-W Arc-Resistant Switchgear Arc-Resistant Arc-Resistant Metal-Clad Switchgear As the first manufacturer to design, test and implement arc-resistant metal-clad switchgear, Eaton is proud to offer Type 2 arc-resistant switchgear assemblies with Type VCP-W drawout vacuum circuit breakers. Configured in a variety of combinations to meet diverse application requirements, these switchgear products provide additional protection for personnel performing normal operating duties in close proximity to equipment. Available in 5/15 kv, 27 kv and 38 kv models Enclosure designed to withstand effects of internal arcing faults, with formed steel compartment design that seals joints under fault conditions, preventing gas and smoke from escaping the switchgear on any of the 4 external sides Testing performed per ANSI C37.20.7 4000 A main bus and main breakers available 63 ka arc resistant ratings available Direct Roll in breakers available Type 2-B ratings available Switchgear is designed to divert pressure and burning from an internal arc fault up and out of the equipment protecting any personnel in the vicinity of the switchgear Circuit breaker compartments include through the door racking mechanism to prevent exposure to potential arc flash Type 2-B ratings available providing control compartment doors that can be opened for access to control wiring without losing the arc resistant protection of the enclosure Easy access and viewing ports on door allow standard functions to be completed without exposure to potential arc flash 2-high configurations coupled with the ability to mount relays on circuit breaker compartment door allow for the most compact switchgear arrangements available on the market eaton corporation Medium Voltage Assembly Solutions 9

Front Accessible MV Switchgear Medium Voltage Solutions Front Accessible MV Switchgear The most flexible, cost-effective, high-performance switchgear available, Eaton s Cutler-Hammer Front Accessible MV Switchgear (MEF) offers a space savings of more than 50 percent within a complete package that can be transported using a fork truck or pallet jack, eliminating the need for cranes or other construction in retrofit applications. Even more, MEF s design can significantly reduce a project s overall cost with a wide variety of configurations, standard drawing packages, intelligent integrated trip units and reduced clearance installation. Available in ratings of 5 and 15 kv with 600, 1200 and 2000 A breakers Eaton s VCP-TL breaker s integral self-powering trip unit eliminates the need for an external power source in addition to a linear actuator that boasts 100,000 mechanical operations Truly front accessible construction eases installation, maintenance, and saves space in an electrical room 30" wide circuit breaker compartments minimize width to help save electrical room space Flexible configurations and standard building blocks provide easy scalability 10 eaton corporation Medium Voltage Assembly Solutions

High Resistance Grounding Eaton s high resistance grounding enhances the safety of a grounded system while minimizing the risk of service interruptions. By providing a path for ground current via a resistance that limits the current magnitude as well as a monitor to determine when an abnormal condition exists these products facilitate maximum continuity of service, since no tripping occurs for the resistance-limited ground fault. Ground current path is provided at the point where the service begins by placing resistance in the connection from system neutral to ground Control equipment continuously measures ground current, while a relay detects when the current exceeds a predetermined level Built-in fault tracing assists in finding the source of the ground, and an alarm alerts building personnel that a ground exists Product Offering Rated maximum voltage: 2.4 kv, 3.3 kv, 4.16 kv Ungrounded wye or delta systems Rated voltage withstand (BIL): 60 kv peak Maximum primary ground fault current: selectable 3, 4, 5 or 6 A Type of ground detection: current or voltage Standards IEEE C37.20.2 Product Applications Indoor and outdoor installations Ground fault detection and control of transient overvoltages during a single-phase to ground fault on an ungrounded system, and minimize possibility of insulation failure in motors, transformers, power cables and electronic equipment eaton corporation Medium Voltage Assembly Solutions 11

Unitized Power Center Integrated Unit Substationtant Unitized Power Center Control, protect and convert primary medium voltage power to utilization voltage at or near the load with the Unitized Substation. This is also an ideal solution for controlling, protecting and distributing low voltage power. Product offering includes: Primary switch: 600 A continuous and load break (non-fused or fused) Transformer: 3-phase kva 112.5 through 1000 Primary voltage 2.4 kv, 5 kv, 15 kv Secondary voltage 208-120 V four-wire, 240 V three-wire 480-277 V four-wire, 480 V three-wire Voltage withstand (BIL) Primary: 2.4 kv Class 20 kv peak 5 kv Class 30 kv peak 15 kv Class 60 kv peak Secondary 10 kv peak Secondary distribution section Main bus 250 to 2500 A Molded case breakers 15 to 2500 A Fusible switches 30 to 1200 A IUS (Integrated Unit Substation) Eaton s Cutler-Hammer IUS combines transformer primary and secondary protective devices in a single section. Eaton s IUS offers a significant floorspace reduction compared to other substation designs. The IUS primary/secondary breaker section is UL listed. The IUS complies with ANSI C37.20.1 and ANSI C37.51 for the low voltage compartment, and ANSI C37.20.3 for the medium voltage compartment. Low voltage power switchgear distribution sections are UL 1558 listed and comply with ANSI C37.20.1. Transformer sections are UL 1562 listed and comply with ANSI C37.30. 12 eaton corporation Medium Voltage Assembly Solutions

Medium Voltage Fusible Switches Medium Voltage Switch (MVS) Eaton s Cutler-Hammer MVS Load Interrupter switchgear is an integrated assembly of switches, bus and fuses that are coordinated electrically and mechanically for medium voltage circuit protection. The metal-enclosed switchgear provides safe, reliable and cost-effective switching and fault protection for medium voltage circuits rated from 2.4 kv through 38 kv. Ideal for applications in lower-duty cycle operation environments Quick-make, quick-break mechanism provides full-load current interrupting capability. Fuses provide accurate, permanently calibrated, shortcircuit detecting and interrupting capabilities Visibility of actual blade position improves safety by providing positive assurance of circuit de-energization Metal-to-metal direct drive mechanism eliminates chains or cables that may break or need adjusting Mini-MVS Space-optimized 26-inch wide design rated at 200 amperes available at 5 kv. For use in power distribution, transformer primary connections and isolation applications requiring a stand-alone assembly, cable in/cable out terminations and manual operation. The switch comes standard with built-in interlocks and safety features and is available fused or non-fused, with an option for an outdoor enclosure. Duplex Switch Configuration Two MVS load interrupter switch sections can be utilized to provide cost-effective source selectivity with a common load side bus feeding one load, fused or non-fused. Key interlocks are a standard feature provided to permit only one switch to be closed at a time and prevent any switch door from opening unless both switches are open. Two-Position, No-Load Selector Switch The MVS load interrupter switch is designed to provide the most cost-effective source selectivity in a single compact structure. It features a two-position non-load-break selector switch in series with the load break MVS switch, which is mechanically interlocked so operation can be performed only when the load interrupter switch is in the open position. Motor Operated MVS Switches The MVS Pow-R-Drive motor operator which provides the safety, convenience and coordination inherent in remote switch operation is a standard, manually operated switch in combination with a heavy-duty electric motor-driven linear actuator that charges the spring. The linear actuator, located in a separate isolated low voltage compartment, smoothly and quietly extends or retracts the proper distance to cause the switch mechanism to operate. Standard motor operators are mounted in the switch enclosure, eliminating the separate motor compartment to conserve floor space. eaton corporation Medium Voltage Assembly Solutions 13

Sustainability It's a part of everything Eaton does geothermal power plant Recycling Solar panels Wind power Biofuel from sunflowers 14 eaton corporation Medium Voltage Assembly Solutions

...SF 6 free design is Eaton's solution to a better planet Environmentally responsible Eaton offers a variety of MV switchgear solutions that utilize environmentally responsible and safety conscious medium-voltage insulation materials. These alternative solutions include air-insulated and solid-insulated switchgear designs that avoid the use of SF 6 gas and can offer a lower total cost of ownership over the complete life cycle of the equipment. While MV switchgear requires an insulation medium to provide electrical insulation between internal components, insulation types can vary among applications, and several can be harmful to the environment, particularly the gas insulated switchgear (GIS) designed by some manufacturers. Conversely, Eaton s MV air-insulated switchgear relies on air and/or solid insulation materials. Installing medium-voltage, SF 6 insulated switchgear is not consistent with the sustainability principles and greenhouse gas reduction goals of many leading-edge corporations and institutions. The safety and special handling concerns can also raise issues with internal Environmental Health & Safety policies. Furthermore, the installation, operation and maintenance, and end of life/recycling concerns associated with medium-voltage GIS switchgear can dramatically raise the total cost of ownership. Finding the solution for you Eaton s medium voltage assembly products encompass a wide range of innovative electrical products that are an important part of our PowerChain Management solutions helping businesses to minimize risk, increase reliability and maximize savings. Eaton offers a full line-up of arc resistant products engineered to meet your specific needs. The expansion of this product line further extends Eaton s reputation as an industry leader in safetyrelated products. To learn more about Eaton s wide array of electrical products, visit our Web site: eaton.com/electrical Or, call to locate your nearest Eaton representative: 877-ETN-CARE (877-386-2273) eaton corporation Medium Voltage Assembly Solutions 15

Eaton s electrical business is a global leader in power distribution, power quality, control and industrial automation products and services. Eaton s global electrical product lines, including Cutler-HammerT, MoellerT, PowerwareT, HolecT, MEMT, SantakT, and MGE Office Protection SystemsE provide customer-driven PowerChain ManagementT solutions to serve the power system needs of the data center, industrial, institutional, government, utility, commercial, residential, and OEM markets worldwide. PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle. With Eaton s distribution, control and automation and power quality equipment; full-scale engineering services; and information management systems, the power system is positioned to deliver powerful results: greater reliability, operating cost efficiencies, effective use of capital, enhanced safety, and risk mitigation. Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) Eaton.com 2009 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR02200001E / MSC June 2009 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.