VOLUME CONTROL DAMPER

Similar documents
LOW LEAKAGE VOLUME CONTROL DAMPER

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Model VCD-20 3V CONTROL DAMPER

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

VCD-23 Low Leakage CONTROL DAMPER

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

HCD-230 Industrial Control Damper

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

VCD-23. Flange Options. Size Limitations

VCD-23. Low Leakage CONTROL DAMPER

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Thermal Isolation. Break

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-43 Extruded Airfoil Blade Control Damper

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

INDEX. Chapter1 6. air master. Volume Control Dampers

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Motorized Fire Dampers

SD-1250 and SD-1600 Series Smoke Dampers

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

HVAC Control & Balancing Dampers

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-212. Combination FIRE SMOKE DAMPERS

AL-Maraj Central A/C Systems Accessories Mfg Co.

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Air Measuring Products AMD AMS IAQ

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

Introduction to Johnson Controls Dampers

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

When Time is Everything... We Manufacture in Days - Not Weeks!

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

DAMPERS WE CONTROL AIR

Zero Leakage Isolation Damper

ARROW UNITED INDUSTRIES

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

HVAC Control & Balancing Dampers

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

SECTION CONTROL DAMPERS

ARROW INDUSTRIAL PRODUCTS

Hison Axial Flow Fans

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Hison Axial Flow Fans

BC 08. Sand Trap Louvers STL-AB-11A LISTED

AD-1251 Probe with Differential Pressure Transducer

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

MOTORIZED VOLUME DAMPER

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Fire, Smoke, and Combination Fire Smoke Dampers

A Complete Line of Quality Products for Marine Applications

INLET BOXES AND INLET-BOX DAMPERS

FOR USE IN SOLUTION AIR HANDLING UNITS

Fan Efficiency Grades and System Effect and Their Effects on HVAC Systems

Propeller Hooded Roof Fans

AD-1250 Airflow Measuring Station

ID-141x 12-Gauge Hat Channel Industrial Damper

RD-2000 Round Control Dampers

Actionair Control and Shut Off Dampers

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

INDEX. Chapter2. air master. Grilles and Registers

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

FSD60/MFSD60 Multi-blade Fire Damper

SECTION AXIAL HVAC FANS

PC-125x Counter-Balanced Backdraft Damper

LOUVERED FACE GRILLES AND REGISTERS

VOLUME CONTROL DAMPERS

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

Transcription:

VOLUME CONTROL DAMPER On Time Delivery According to Standard Customization Quality Cooperation VCD CATALOG REV 00 APRIL 2018 2017_04_04

ABOUT US Sharqawi Air distribution systems Co. Factory, has been in the market since 1995, as one leading manufacturer in the kingdom of Saudi Arabia in the field of fabrication of HVAC duct and its Accessories. Upon whose satisfaction we have been allowed to grow and prosper in this highly competitive marketplace. As one of the leading HVAC ducts and its accessories manufacturers, our reason of being is a combination of our vision, mission, and values. Vision: We aspire making Sharqawi the most trusted manufacturer of HVAC ducts and its accessories in the Kingdom of Saudi Arabia, region and the world. Mission: To aim for design perfection and expanding our market-share by enhancing our marketing, satisfying customer requirements, complying with the international quality standards and consistently sustaining our improvement program. Values: Our values reflect who we are and our reason for being. Quality: We provide exquisite products that deliver exceptional values to our customer. Integrity: We boost the highest integrity in all of our activities and operations. Customer commitment: we develop positive relationships that make a beneficial influence on our client s business. Teamwork: We work together across boundaries to meet the expectations of our customers and support the company to win. A Will To Win: We exhibit a strong will to win in the marketplace and every aspect of our business. Respect for people: We value our people, encourage their development and reword their performance. Good residents: We are good residents in the communities in which we live and work. Personal Accountability: We are personally accountable for delivering on our commitment.

Volume Control Damper CONSTRUCTION Description Volume control damper Balancing/ Shut-off type are ruggedly designed to suit client individual requirements, for controlling airflow with motorized or manual operations applications, in low to high pressure and velocity ventilation systems. OPPOSE MECHANISM DAMPER Frame Specification Shaft Blades Galvanized Steel MATERIAL Black Steel Stainless Steel FRAME 1.5:3.0 mm BLADE 1.2:3.0 mm 3V Bearing Pin Section SHAFT Zinc Coated Steel Round Dia. 1/2 Inch, 12.6 mm PARALLEL MECHANISM DAMPER Square 3/8 Inch, 9.7 mm BEARINGS Self-Lubricating Bronze In flow/ Side Mechanism LINKAGE Oppose/ Parallel Size Limitations HEIGHT (H) HEIGHT + FLANGE WIDTH X HEIGHT SINGLE SECTION MIN MAX MULTIPLE SECTION MAX Shaft MM 100 x 100 914 x 1829 7620 x 3048 INCH 4 x 4 36 x 72 300 x 120 * Damper up to 300 mm height are single blade construction (If not otherwise specified) WIDTH (W) WIDTH + 2 x FLANGE Length 1

Volume Control Damper SINGLE / MULTIPLE SECTION CONFIGURATIONS Dimensions SECTION WIDTH DAMPER HEIGHT DAMPER HEIGHT SINGLE SEC. & SINGLE BLADE W 914 and H 300 SINGLE SEC. & MULTIPLE BLADE W 914 and H 1825 (HEIGHT SINGLE SEC.) X (WIDTH MULTIPLE SEC.) W> 914 and H 1825 SECTION WIDTH DAMPER HEIGHT SECTION HEIGHT (HEIGHT MULTIPLE SEC.) X (WIDTH SINGLE SEC.) W 914 and H 1825 (HEIGHT MULTIPLE SEC.) X (WIDTH MULTIPLE SEC.) W> 914 and H 1825 Notes: 1. All dimensions in millimeter (mm) 2. Multiple section number in the figures for indication only, for calculating the actual number check the following example for damper (W 2200 X H 2000) *Number of section in width = 2200/914= 2.4, roundup to nearest integer = 3 *Number of section in height = 1900/1825= 1.1, roundup to nearest integer = 2 2

Volume Control Damper AIR PERFORMANCE Pressure Drop DV Air Performance testing is performed in accordance withtest Method per ANSI / AMCA Standard 500-D-12 (Pressure Drop), Figure 5.3 Duct Upstream and Downstream. 1.00 Pressure Drop 305 mm x 305 mm 2515 0.16 2013 0.09 1501 0.05 1004 0.02 499 0.01 Static Pressure Drop in.wg 0.10 0.01 610 mm x 610 mm 2474 0.08 1981 0.05 1478 0.03 984 0.01 518 0.00 914 mm x 914 mm 2211 0.04 1771 0.02 1325 0.02 880 0.01 438 0.00 0.00 100 1000 10000 Face Area fpm 305 mm x 305 mm 610 mm x 610 mm 914 mm x 914 mm 305 mm x 1220 mm 1220 mm x 305 mm 305 mm x 1220 mm 2470 0.10 1977 0.07 1476 0.04 983 0.02 539 0.01 1220 mm x 305 mm 2470 0.16 1978 0.11 1476 0.06 980 0.03 539 0.01 3

Volume Control Damper AIR PERFORMANCE Air Leakage DV Air Leakage testing is performed in accordance with Test Method per ANSI / AMCA Standard 500-D-07 (Leakage), Figure 5.5 Alternate, Applied Torque 44 lb.inch (5 N.m) 10 AIR LEAKAGE 914 mm x 914 mm Pressure in.wg 1 1 10 100 1000 Leakage Though Face Area (cfm/ft^2) DAMPER W 914 mm X H 914 mm CLASS I CLASS II CLASS III * This Damper Certified for Air Performance Only (Pressure Drop) 4

(mm) DAMPER HEIGHT (mm) DAMPER LENGTH (mm) Volume Control Damper ORDERING CODE VOLUME CONTROL DAMPER B S 1 DV - G D 1 A 0-600 x 400 x 100 * All selection checkboxes highlighted in blue are the default selections (If not otherwise specified) 1 2 3 4 5 6 7 8 9 10 11 MODEL B BALANCING RECTANGULAR S SHUT OFF RECTANGULAR 1 WALL TYPE S SINGLE WALL K DOUBLE WALL 2" 24 AF E DOUBLE WALL 1" 24 AF L DOUBLE WALL 2" 24 KM F DOUBLE WALL 1" 24 KM M DOUBLE WALL 2" 48 AF G DOUBLE WALL 1" 48 AF N DOUBLE WALL 2" 48 KM H DOUBLE WALL 1" 48 KM 2 MECHANISM 1 OPPOSE -EXPOSE 2 PARALLEL-EXPOSE 3 OPPOSE -SIDE 4 PARALLEL-SIDE 3 MATERIAL G G90 V S316L/4 H G115 W S316L/2B J G90-JAPEN Z G90-ZERO SPANNLE S S304 B BS37 U S304/2B A ALUMINUM 4 THICKNESS 5 D DEFAULT U 1.6 mm W 2.0 mm X 2.4 mm Z 3.0 mm 1) Default value, based on designer specs. Often blade 1.2 mm and frame 1.5 mm. 2) Selction any other thickness blade and frame will have same selected thickness. CONNECTION 6 1 FLANGE 35 2 FLANGE 50 3 FLANGE 25 4 FLANGE 30 5 FLANGE 40 6 FLANGE 45 7 FLANGE 60 8 FLANGE 75 9 SLIP & DRIVE DRIVE TYPE 7 A MANUAL F WITHOUT B MOTORIZED 230V BELIMO D MOTORIZED 24V BELIMO C MOTORIZED 230V SIEMENS E MOTORIZED 24V SIEMENS FINISHING 8 0 NO PAINT NO PACKAGING 2 PACKAGING ONLY 1 PAINT ONLY 3 PAINT & PACKAGING Code Description Example DV-BS1G1A0-600x400x100 VOLUME CONTROL DAMPER, Rectangular Flanged Type, Balancing, Single Wall, Oppose-Expose Mechanism, Material Galvanized Steel (G90), Flange 35mm, Manual Drive, Without Packaging And Without Painting. Damper Width = 600 mm Damper Height = 400 mm Damper Length = 100 mm 5

008