CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Similar documents
ECONOMIZERS. 1/2012 Supersedes

ECONOMIZERS. 5/2012 Supersedes

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

INSTALLATION INSTRUCTION

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Installation Instructions

Installation Instructions

Installation Instructions

Package Unit Modulating Economizer Installation Instructions

INSTALLATION INSTRUCTIONS

Package Unit Modulating Economizer Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

INSTALLATION INSTRUCTIONS

Installation Instructions DNECOMZR020A02, DNECOMZR021A03 (For 3 to 12.5 Ton Units) and DNECOMZR062A00 (For RHS 12.5 Ton Heat Pump Units)

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Installation Instructions

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

WARNING IMPORTANT

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

R81EAA Type Plug-In Electronic Circuit Board Kit For Series M100 Motor Actuators

IMPORTANT ATTENTION INSTALLERS:

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

LXIPEB33 505,038M MARCH 14, 2012 SUPERCEDES

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

R81EAA-2 Economizer Circuit Board

Installation Instructions

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

TOYOTA TUNDRA TVIP V4 Preparation

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

Installation Instructions

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

Installation Instructions

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

ECONOMIZER FAN. Receiving and Inspection

Installation Manual. Low Ambient Cooling Kit. ZLABKA01A Low Ambient Cooling Kit. ZLABKA02A Low Ambient Cooling Kit

WATER COOLED AIR CONDITIONING UNITS MODEL CVWSEK-060 WATER SIDE ECONOMIZER FOR CSV060B VERTICAL R-410A STYLE B R-410A

Installation Instructions

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA

INSTALLATION INSTRUCTIONS MODELS (-)XRD-MCCM3 & (-)XRD-MECM3/TECM3 CONVERTIBLE AIRFLOW ECONOMIZERS

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

LE MODELS: SHIPPING, RIGGING, LIFTING, ASSEMBLY MANUAL

INSTALLATION INSTRUCTION

TOYOTA TUNDRA TVIP V4 REMOTE ENGINE STARTER (RES)

AIR CONDITIONING KIT INSTALLATION MANUAL

MicroMetl. INSTALLATION INSTRUCTIONS Dual Stage Relief Economizer ECD-SRT12DR, ECD-SRT34DR, ECD-SRT5SDR & ECD-SRT5LDR

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes

INSTALLATION INSTRUCTIONS

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Safety & Installation Instructions

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Installation Instructions

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Installation Instructions

Model 8144NC Fresh Air Ventilator


Instruction Sheet Kit Number:

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

JODALE PERRY. Parts List & Mounting Instructions. Jacobsen HR9016 JDP BUILT FOR LIFE

Installation Instructions

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

Steering Column - Steering Column Removal and Installation

& 76 CHEVROLET NOVA HEATER ONLY

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

Induction Power Supplies

PS1201A00, PS1202A00 and PS2401A00 Replacement Power Supplies for Electronic Air Cleaners

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

P/N Rev. A. Proximity Sensor Add-On for SMART2 ProTrap on StrapTrap Hoppers

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

Rear Quick Attach System Kit For Groundsmaster 7200/7210 Series Mower

Transcription:

OUTDOOR AIR S Litho U.S.A. 507214-01 2014 12/2014 Supersedes 9/2013 OUTDOOR AIR S INSTALLATION INSTRUCTIONS FOR OUTDOOR AIR S AND OUTDOOR AIR USED WITH 156-300S UNITS Shipping and Packing List Package 1 of 1 contains: Outdoor Air Damper 1- Outdoor air damper (OAD) assembly 1- P4 wiring harness (58W62 only) 1- Economizer end plate 1- Bag assembly containing: #10 Sheet metal screws D2 Wiring diagram section Outdoor Air Hood 1- Hood top* 1- Hood top seal 2- Hood sides* 2- Top filter brackets* 1- Bottom filter bracket* 2- Side filter brackets* 3- Filters* 1- Hood top stiffener 1- Top seal stiffener *When economizer is factory-installed, hood sides, side filter brackets and filter are packaged separately and shipped in the blower compartment. The top and bottom filter brackets are secured to the hood top and the hood top is shipped in place on the unit. WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier Page 1 CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Application Optional outdoor air dampers provide fresh outdoor air. See table 1 for usage. K1DAMP20C-1 and E1DAMP20C-1 Motorized Dampers: Damper opens to a set position, as shown in the Determine Fresh Air Percentage section, when the blower is operating. To operate the dampers only during the occupied time period, an optional thermostat or energy management system must be installed when a unit is not equipped with a Unit Controller. Both blower operation AND an occupied signal are required for dampers to energize. See figure 1. C1DAMP10C-1 Manual Damper: Damper is manually operated; damper position is manually set at installation and remains in that position. See figure 2. Motorized Damper - K1DAMP20C-1 1- Disconnect all power to unit and open filter access panel. 2- Align bottom of damper assembly with support bracket and slide assembly into unit. See figure 1. Make sure flanges align as shown in figure 3. 3- Fit damper assembly end plate over end of assembly and secure with retained screws. 4- Remove P3 jumper plug from J3 unit jack and discard. 5- Connect damper motor plug P4 to unit jack J3. TABLE 1 Damper Type Unit Model # Part # Cat. # Manual 156-300S C1DAMP10C-1 604592-01 54W76 Motorized LGH/LCH156-300S E1DAMP20C-1 604592-02 54W74 Motorized KG/KC/KH 180-300S K1DAMP20C-1 604592-05 58W62

MOTORIZED OUTDOOR AIR MOTOR ASSEMBLY J3 UNIT JACK P4 ECONOMIZER PLUG END PLATE BOTTOM OF ASSEMBLY FIGURE 1 SUPPORT MANUAL OUTDOOR AIR 7- Affix wiring diagram section to inside of compressor access panel. Position to the right of the C1 control section diagram. 8- Replace filter access panel and apply power to unit. LOOSEN WING NUT AND ADJUST LEVER TO DESIRED SETTING. FIGURE 2 6- Connect three harness wires to OAD damper motor. See figure 4. Page 2

ALIGN FLANGES FILTER SECTION TO UNIT WIRING DISCONNECT P3 JUMPER PLUG FROM J3 UNIT JACK J3 P3 DISCARD P3 CONNECT P4 ECONOMIZER PLUG TO J3 UNIT JACK ASSEMBLY TO UNIT J3 P4 DIVISION PANEL B7-T B7-X SUPPORT ON UNIT FIGURE 3 9- When connecting a thermostat or energy management system occupied/unoccupied output, remove the jumper wire between TB1 terminals R and OC. Connect output signal wires to R and OC on TB1. FIGURE 4 B7-D Motorized Damper - E1DAMP20C-1 1- Disconnect all power to unit. 2- Release latches and open filter access panel. 3- Align bottom of damper assembly with support bracket and slide assembly into unit. See figure 1. 4- Fit damper assembly end plate over end of assembly and secure with retained screws. 5- Connect damper motor plug P3 to unit jack J3. Manual Damper - C1DAMP10C-1 1- Disconnect all power to unit. 2- Open filter access panel. 3- Align bottom of damper assembly with support bracket and slide assembly into unit. See figure 2. 4- Fit damper assembly end plate over end of assembly and secure with retained screws. 6- Loosen wing nut on damper adjustment lever on damper assembly end plate. Adjust to desired setting and tighten wing nut. See figure 2. Page 3

Prodigy Unit Controller Damper Settings Use the following procedure to enable motorize damper operations for both the M2 and M3 Unit Controllers. MOTORIZE S PRODIGY M2 UNIT CONTROLLER Use the following menu: Settings>Install>New M2> > Damper > MOAD To enable the motorized damper function on the M3 Unit Controller, go to SETUP > INSTALL and proceed through the various screens until CONFIGURATION ID 1 appears. To enable set position 3 to M (Motorized Outdoor Air Damper Only). Determine Fresh Air Percentage Fresh air percentage is determined in the same manner for both manual and motorized dampers. Measure fresh air percentage according to the following steps and adjust dampers to the specified amount. 1- Set damper to allow approximate amount of outdoor air into the unit. MANUAL S - Loosen screws on both sides of dampers and slide to open dampers. PRODIGY M2 UNIT CONTROLLER E1DAMP20C-1 Only - Locate the Unit Controller in the main control area. See figure 5. Set the DIP switch to DSET position as shown in figure 6. LED FLASHING GREEN HEARTBEAT LED INDICATES NORMAL OPERATION STEADY YELLOW OUTDOOR AIR SUITABLE LED INDICATES OUTDOOR AIR CAN BE USED FOR COOLING UNIT CONTROL M2 UNIT CONTROLLER ECONOMIZER DIP SWITCH 0-100% MINIMUM POSITION POTENTIOMETER FIGURE 5 DIP SWITCH SETTINGS DSET ( SET) NOTE - Damper set mode locks economizer into minimum position. FIGURE 6 E1DAMP20C-1 Only - Go to SETUP > TEST & BALANCE > MIN POSITION (BLOWER ON HIGH) and adjust Min Damper Position to desired air percentage. NOTE - If blower supports more than one speed, then the blower is running at high speed at this point. 2- Measure outdoor air temperature. Mark the point on the bottom line of chart 1 and label the point A (40 F, 4 C shown). 3- Measure return air temperature. Mark that point on the top line of chart 1 and label the point B (74 F, 23 C shown). 4- Measure mixed air (outdoor and return air) temperature. Mark that point on the top line of chart 1 and label point C (70 F, 21 C shown). Page 4

5- Draw a straight line between points A and B. 6- Draw a vertical line through point C. 7- Draw a horizontal line where the two lines meet. Read the percent of fresh air intake on the side. 8- K1DAMP20C-1 Only - Honeywell Actuator - If fresh air percentage is less than desired, adjust thumbwheel higher. If fresh air percentage is more than desired, adjust thumbwheel lower. Repeat steps 2 through 7 until calculation reads desired fresh air percentage. See figure 7. Siemens Actuator - Damper stops are factory-set at 100% outdoor air and are adjustable in five degree increments. To adjust fresh air percentage, remove retainer clip and adjust damper stop to desired air percentage. See figure 8. Replace retainer clip. Repeat steps 2 through 7 until calculation reads desired fresh air percentage. HONEYWELL MOTOR THUMBWHEEL FIGURE 7 100% CLOSED RETAINER CLIP SIEMENS MOTOR FIGURE 8 STOP 100% OPEN PRODIGY M2 UNIT CONTROLLER E1DAMP20C-1 Only - If fresh air percentage is less than desired, adjust MIN POS SET potentiometer higher. If fresh air percentage is more than desired, adjust MIN POS SET potentiometer lower. Repeat steps 2 through 7 until calculation reads desired fresh air percentage. NOTE - Manual damper fresh air intake percentage can be determined in the same manner. If fresh air percentage is less or more than desired, increase or decrease minimum damper position. Go to SETUP > TEST & BALANCE > MIN POSITION Repeat steps 2 through 7 until calculation reads desired fresh air percentage. Page 5

PRODIGY M2 UNIT CONTROLLER E1DAMP20C-1 Only - Set the DIP switch to GLO position as shown in figure 9. NOTE - E1DAMP20C-1 Only - In addition to the previous method, damper minimum position may also be remotely set using Unit Controller software (ECTO 5.24). A remote adjustment will override potentiometer adjustment. Refer to Unit Controller manual. Press SAVE to save the minimum damper position. At this point, if blower supports more than one speed, then the user interface prompts you to enter the min damper position when blower is running at low speed. Repeat steps 2 7 to determine the minimum damper position when blower is running at low speed and save the value. F C -20-29 0 10 FREE COOLING SETTINGS FIGURE 9 GLO (Global Enthalpy) CHART 1 CALCULATE MINIMUM FRESH AIR PERCENTAGE MIXED AND RETURN AIR TEMPERATURE 0 10 20 30 40 50 60 70 80 90-18 -12-7 -1 4 10 16 21 27 32 C B -10-23 100 38 F C 0 10 20 20 30 30 40 40 50 50 60 60 70 70 80 80 90 100 F -20 C -29-10 -23 0-18 A 10-12 20-7 30-1 40 4 50 10 60 16 70 21 OUTDOOR AIR TEMPERATURE 80 27 90 32 100 38 90 100 F C Page 6

Outdoor Air Hood The outdoor air hood is packaged separately but attached to the damper assembly crate. Use #10 self drilling screws to install hood unless noted otherwise. Refer to figures 10, 11, 12, 13, and 14. 1- Remove and retain screws securing unit top back panel; remove and discard panel. 2- Secure top seal stiffener to back side of hood top seal. See figures 10 and 11. 3- Slide hood top seal under unit cabinet top and secure using five retained top screws. Install, but do not tighten, the two screws on each end of the hood to seal. Refer to figure 11. 4- Remove and retain top three screws on the left mullion of the outdoor air section. See figure 11. 5- Secure hood top stiffener to unpainted side of the hood top with ten screws. See figures 10 and 12. 6- Position the hood top edge V-channel under the corresponding V-channel on the hood top seal and slide into place from right to left. See figure 10 and 11. 7- Tighten the two screws on each end of the hood top seal left loose in step 3. SIDE VIEW TOP SEAL TOP SEAL TOP FILTER ALIGN VERTICAL HOLES ON WITH VERTICAL HOLES ON SIDE OF FIGURE 10 TOP REMOVE FIVE SCREWS ON TOP PANEL FLANGE UNIT TOP PANEL TOP SEAL END SCREWS ALIGN TOP WITH TOP SEAL AT THIS END REMOVE THREE MULLION SCREWS TOP SEAL END SCREWS SECURE TOP SEAL HERE DIVISION PANEL OUTDOOR COIL BOTTOM PANEL RIGHT MULLION LEFT MULLION FIGURE 11 Page 7

8- Install L-shaped left side filter bracket to left hood side. See figure 12. 9- Secure left hood side to the hood top. See figure 13. Secure the left hood side to the unit using three screws removed in step 4. See figure 13. 10- Install the right side filter bracket to the right hood side. See figure 12. 11- Factory-Installed Economizers - Remove the bottom filter bracket from the hood top assembly panel. See figure 15. 12- Factory-Installed Economizers - Remove the short and long top filter brackets from the hood top assembly panel. See figure 15. 13- Secure the right hood side to the hood top. See figure 14. Do NOT secure the right hood side to unit. 14- Align the two holes on the left hood side with the two holes in the bottom filter bracket. See figures 10 and 13. Secure with screws. 15- Secure bottom filter bracket to right hood side in the same manner. See figures 10 and 14. 16- Secure the right hood side to the unit as shown in figure 14. 17- Secure the top filter bracket (long) to the hood top. See figures 10 and 12. Slide two filters into place. Note - Slide the filters to the left side of the hood. Make sure there are no air gaps between either two filters or the filter and the left hood side. 18- Insert the third filter into the bottom filter bracket. Position the top filter bracket (short) as shown in figures 10 and 12. Secure the bracket to the hood top with screws. 19- Make sure there are no gaps between the filters by sliding the filters to the left. 20- Caulk (field-provided) both ends of the top seal and hood top as shown in figures 13 and 14. TOP END SCREWS END VIEW TOP END SCREWS TOP TOP RIGHT SIDE END VIEW LEFT SIDE TOP FILTER (LONG) TOP FILTER (SHORT) RIGHT SIDE FILTER LEFT SIDE FILTER FILTERS FIGURE 12 Page 8

LEFT SIDE VIEW RIGHT SIDE VIEW SEAL WITH CAULK TOP SEAL TOP SEAL CORNER OF UNIT TOP TOP SEAL WITH CAULK HOLES FOR LEFT SIDE RIGHT SIDE LEFT MULLION HOLES FOR FIGURE 13 FIGURE 14 REMOVE S (FACTORY-INSTALLED ECONOMIZERS) TOP REMOVE TWO SCREWS REMOVE THREE SCREWS TOP FILTER (LONG) TOP FILTER (SHORT) FIGURE 15 Page 9