Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Similar documents
Type VBII Visible Blade Disconnect Switches

SPEEDFAX TM 2011 Disconnect Switches Contents

POWER PRODUCT Disconnect Switches Contents

General and Heavy Duty Safety Switches

File E Vol. 3 Sec. Gen. Page 1 Issued: Revised: Type VBII enclosed switch components for OEM assembly.

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES

General and Heavy Duty Safety Switches Accessories

Product Specification Sheet #3LD2.1

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

FUSIBLE DISCONNECT SWITCHES

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Load Break Disconnect Switches FSLBS

footprint of traditional fusible switches

Low Voltage Products. Catalog. Flange Handle Operated Disconnect Switches. Non Fusible 30A A Fusible 30A - 800A

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

for Non-Fusible Disconnect Switches

GHN424NW HHN426N HUN361AW

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

T CLASS T FUSE BLOCKS

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Compact Circuit Protector

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

SD Series Non-Fused Load Switches

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

SECTION PANELBOARDS

Product Guide. NEMA pump controls.

Effective December 2015 Supersedes September 2013

Bussmann series Quik-Spec Coordination Panelboard

Safety and Disconnect Switches

Disconnect switches Non-fusible Fusible Enclosed

Heavy Duty Safety Switches

Safety Switches. c o n t e n t s SPEEDFAX TM 2017

SECTION MOTOR CONTROL

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Switches Safety and Disconnect Switches

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

Overview for Fusible Disconnect Switches

1.1. Switching Devices

Compact Circuit Protector (CCP)

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Compact Circuit Protector

UL 508 Non-Fusible Disconnect Switches

QMB Fusible Panelboards

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

+ + + OS400J03 + OXP12X280 + OHB145J12 + OZXA-24. UL general purpose amp rating. UL Fuse Type 600V Catalog number Catalog number Catalog number

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

UL 508 Non-Fusible Disconnect Switches

Section Contents. Disconnect Switches

Quik-Spec Coordination Panelboard Specifications

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

UL 98 Fusible Disconnect Switches

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Compact Circuit Protector (CCP)

Cable-Operated Disconnect Switches. Accessories

600V, Non-Fusible, (3-Pole, 3 Phase)

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible

Quik-Spec Electrical Gear

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600V. International acceptance. Disconnect switches. Non-fusible

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Contents. Volume 5 Motor Control and Protection CA E December

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

IN2 Enclosed Switches and Circuit Breakers

Selection and application guide

Gears & Fuse Gears. American General Purpose Fuses Cylindrical & Blade Fuse Blocks Class H, K & R CLASS H, K AND R FUSE BLOCKS. Ratings.

Enclosures. See Section Typical Description

F-Series. Circuit Breaker

Disconnect Switches and Operating Mechanisms. Section 7.

Multi-Pak Group Control

F-Series. Circuit Breaker

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

Control Circuit Protection

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Transcription:

Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies facilite installation Panel mounted switches are variable depth Short circuit rating of 10,000 AIC with class H fuse, and of 200,000 AIC with class R or J fuses Flange mounted handles are Type 1 and 12 rated and padlockable in the off position with up to (3) padlocks with 5/16 hasps Meets UL98 requirements and suitable for both main and branch circuit applications Features and Ordering Information A complete line of aux contacts are available Load break and horsepower rated Defeatable cover interlock standard with all handles Meets NFPA79 requirements VBFS361, VBLK1 & VBH1 VBFS363F VBNFS365, VBLK & VBH2 Ordering Information 1. Determine the ratings required (amps, volts, HP, Fusible, NF), the mounting needed (Panel or Flange), and select the appropriate switch. 2. For panel mounted switches with a rigid operating shaft (30-600A), order panel mounted switch flange mounted operating handle & rigid linkage kit based on depth required. 3. For panel mounted switches with a Max-Flex operator, order panel mounted switch, Max-Flex Handle & Adapter Kit and drive cable.. Select accessories if required. 30-200A handles are also rated Type 3R & X. -6

es Selection Horsepower Rating, es and 3-Phase Max. AC 600 Ampere Voltage 20 Volts AC 80 Volts AC 600 Volts AC Volts DC Rating Rating Number Standard Max. Standard Max. Standard Max. (max) Price $ Fusible Panel Mounted Variable Depth es - 3-Pole 30 20 VBFS321 3 7 1/2 582.00 60 20 VBFS322 7 1/2 15 670.00 30 600 VBFS361 5 15 7 1/2 20 15 605.00 60 600 VBFS362 15 30 15 50 30 710.00 100 600 VBFS363 25 60 30 75 50 1327.00 200 600 VBFS36 50 125 60 150 50 26.00 00 600 VBFS365 100 250 125 350 50 69.00 600 600 VBFS366 150 00 200 500 50 7098.00 Non-fusible Panel Mounted Variable Depth es - 3-Pole 30 600 VBNFS361 10 20 30 15 529.00 60 600 VBNFS362 20 50 60 30 605.00 100 600 VBNFS363 0 75 100 50 107.00 200 600 VBNFS36 60 125 150 50 1813.00 00 600 VBNFS365 125 250 300 50 36.00 600 600 VBNFS366 200 00 500 50 5261.00 Fusible Flange Mounted es - 3-Pole 30 20 VBFS321F 3 7 1/2 851.00 60 20 VBFS322F 7 1/2 15 90.00 30 600 VBFS361F 5 15 7 1/2 20 15 875.00 60 600 VBFS362F 15 30 15 50 30 981.00 100 600 VBFS363F 50 60 30 75 50 1597.00 200 600 VBFS36F 100 125 60 150 50 2718.00 Non-fusible Flange Mounted es - 3-Pole 30 600 VBNFS361F 10 20 30 15 798.00 60 600 VBNFS362F 20 50 60 30 875.00 100 600 VBNFS363F 0 75 100 50 13.00 200 600 VBNFS36F 60 125 150 50 208.00 Note: Fusible switches include fuse provisions for Class H Fuses. The load base can be moved to pre-drilled holes for Class J Fuses. If Class R Fuses are required add a Class R Fuse Clip Kit. Flange Mounted Operating Handles For use with Panel Mounted es. Included with Flange Mounted es as standard. Handle Assembly VBH1 30-200A Type 1, 3R & 12 20.00 VBH1X 30-200A Type X 399.00 VBH2 00 Type 1 & 12 76.00 VBH2R 00 & 600A Type 1, 3R & 12 560.00 VBH2X 00 & 600A Type X 760.00 Cable Kit For use with 30-200A panel mounted switches and Max-Flex handle and adapter kit. FHOEC036 36" long drive cable 153.00 FHOEC08 8" long drive cable 182.00 Rigid Linkage Kits For use with Panel Mounted es. Not required for Flange Mounted es. Ampere Enclosure Depth Number Rating Min Max. Price $ VBLK1 30-200 6.9 6.9 29.50 VBLK2 30-200 6.9 19.0 35.00 VBLK3 00 & 600 9.00 8.75 6.50 VBLK 00 & 600 9.00 19.0 5.00 Max-Flex TM Handle and Adapter Kit (Type 1, 12, 3R & X) Use with 30-200A panel mounted switches and cable kit. VBHM1 30-200A Max-Flex Adapter Kit 2.00 VBNFS361, VBHM1 & FHOEC036 Rated 5 HP at 250V DC. Rated 10 HP at 250V DC. 600V DC & 600V DC horsepower rating shown requires (2) poles to be connected in series. Std. - applies when non-time delay fuses are used. Max. - applies when time delay fuses are used. Includes line base, load base, operating mechanism and line and load lugs. Order operating handle and linkage kits from tables on this page. Includes line base, load base, operating mechanism line and load lugs operating handle and required linkage. Dimensions (min. & max.) from enclosure mounting pan to outside surface of enclosure handle mounting flange. 7.12 for 200A switches. -7

Accessories HR612 HT63 HN612 Class R Fuse Clip Kits These kits prevent the installation of Class H and K fuses (one kit required per switch). Class R Fuse Clip Kits Number Price $ Description HR21 83.00 30A, 20V Kit (HD only) HR612 83.00 30A, 600V Kit/60A, 20V Kit HR62 83.00 60A, 600V Kit HR63 5.00 100A Kit HR6 5.00 200A Kit HR656 137.00 00A/600A Kit Class T Fuse Adapter Kits 100-600A fusible switches are field convertible to accept Class T fuses. 00-600A switches are field convertible to accept Class T fuses by moving the load base to a pre-drilled T fuse position. Class T Fuse Adapter Kits Number Price $ Description HT23 76.00 100A, 20V Kit HT63 120.00 100A, 600V Kit HT2 102.00 200A, 20V Kit HT6 13.00 200A, 600V Kit 200% Neutral Kits UL listed 200% Neutrals are available on 60 & 100A switches. They are typically used with non-linear transformers or where increased neutral ampacity/lug capacity is required. 200% Neutral Kits Kit Wire Range Ampere Line & Load Rating Number Price $ Lugs (Cu/Al) 100 HN263 225.00 (2) #1-1/0 AWG Class J Fuse Provisions All 30-600A, 600V fusible switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. Internal Door Latch Kits For use with enclosures with door mounted latching bar. Required when a flange mounted switch is mounted in a Hoffmann or Rittal enclosure provided with an AB cutout. DKR2 2 point (for use with enclosures less than 0" high) 338.00 3 point (for use with DKR3 enclosures 0" or larger 377.00 in height) Neutral Kits Standard Neutral Kits can be field installed in 30-100A switches. Neutral Kits Kit Ampere Rating Number Price $ 30A 600V, 60A 20V HN612 97.00 60A, 600V & 100A HN623 186.00 Window Kits (Type 1, 12, 3R and x) Allows viewing of visible blades and of indicating fuses through 200A. VBWK1 30A Window Kit 109.00 VBWK2 60 & 100A Window Kit 118.00 VBWK3 200-600A Window Kit 123.00 Built to order. Allow 6 8 weeks for delivery. One kit per pole required. -8

HA16123 HA26123 HP61 Auxiliary Contacts Accessories The auxiliary contacts are available in 1 normally open and 1 normally closed or 2 normally open and 2 normally closed configurations. Siemens offers a PLC Auxiliary (30-200A) that has very low resistance for low voltage and current typical in PLC circuits. All auxiliary contacts make after and break before main switch contacts. Aux. Kit Ampere Rating Kit Horsepower Rating Ampere 125V AC 250V AC 28V DC 125V AC 250V AC 28V DC Rating Number Price $ Max. Max. Max. Max. Max. Max. With 1 NO & 1 NC Isolated Contacts 30-200 HA16123 239.00 10 10 1/2 3/ 00-600 HA165678 587.00 10 10 1/2 3/ With 2 NO & 2 NC Isolated Contacts 30-200 HA26123 266.00 10 10 7 1/2 3/ 00-600 HA265678 61.00 10 10 7 1/2 3/ Low Current PLC Type with 1 NO & 1 NC Gold Plated Contacts 30-200 HA36123 302.00 10 10 1/2 3/ 00-600 HA365678 63.00 10 10 1/2 3/ Fuse Puller Kits Fuse Puller Kits are field installable in 30-100A Type VBII Heavy Duty es (one kit required per 3-pole switch). Ampere Fuse Puller Kit Rating Number Price $ 030 HP61 21.00 060 HP62 21.00 100 HP63 21.00 Copper Lug Kits All switches are UL approved to accept field installed copper lug kits. Copper Lug Ampere Rating Number Price $ Description 30 60 HLC612 138.00 (9) Lugs/Kit #1- AWG Cu 100 HLC63 172.00 (9) Lugs/Kit #1-1/0 AWG Cu 200 HLC6 212.00 (9) Lugs/Kit #6 AWG-300 Kcmil Cu 00 600A HLC65678 37.50 (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu Equipment Ground Kits Equipment Ground Lug Kits are available for all switches. HLC612 Ampere Number of Wire Range Rating Number Price $ Terminals Per Terminal (Cu/Al) 30 200 HG6123 2.00 2 #1- AWG 00 & 600 HG656 123.00 #6 AWG-250 Kcmil Built to order. Allow 6 8 weeks for delivery. -9

Lugs 30 & 60A switches are suitable for use with 60 or 75 C wire. 100 600A switches are suitable for use with 75 C rated wire. All switches are supplied with factory installed line and load lugs. Lug Wire Ranges & Dimensions Wire Ranges (Line, Load and Standard Neutral) Ampere Rating UL Approved Wire Range Lug Wire Range 30 #1-6 AWG (Cu/AI) #1-2 AWG (Cu/Al) 60 #1-2 AWG (Cu/AI) #1-2 AWG (Cu/Al) 100 #1-1/0 AWG (Cu/Al) #1-1/0 AWG (Cu/Al) 200 #6 AWG-300 Kcmil (Cu/Al) #6 AWG-300 Kcmil (Cu/Al) 00 1/0 AWG-750 Kcmil (Cu/Al) or (1) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-250 Kcmil (Cu/Al) (2) 1/0 AWG-250 Kcmil (Cu/Al) 600 (2) 1/0 AWG-750 Kcmil (Cu/Al) or (2) 1/0 AWG-750 Kcmil (Cu/Al) or () 1/0-250 Kcmil (Cu/Al) () 1/0 AWG-250 Kcmil (Cu/Al) Approximate Dimensions Mounting bracket shown with handle installed is supplied with Flange Mounted es only. All Panel Mounted es have a L shaped mounting pan with a line base, load base (if fusible) and mechanism installed. Dimensions Number A B C D (min) D (max) Fusible, Panel Mounted VBFS321 11.88 N/A 6.62 6.81 19 VBFS322 13.12 N/A 8.50 6.81 19 VBFS361 11.88 N/A 6.62 6.81 19 VBFS362 13.12 N/A 8.50 6.81 19 VBFS363 13.12 N/A 8.50 6.81 19 VBFS36 17 N/A 12.33 7.05 19 VBFS365 26.25 N/A 16.50 8.63 19 VBFS366 26.25 N/A 16.50 8.63 19 Non-fusible, Panel Mounted VBNFS361 9.79 N/A 6.62 6.81 19 VBNFS362 9.79 N/A 8.50 6.81 19 VBNFS363 9.79 N/A 8.50 6.81 19 VBNFS36 10.77 N/A 12.33 7.05 19 VBNFS365 13 N/A 16.50 8.63 19 VBNFS366 13 N/A 16.50 8.63 19 Fusible, Flange Mounted VBFS321F 11.88 1.06 7.00 7.27 N/A VBFS322F 13.12 15.83 8.85 7.27 N/A VBFS361F 11.88 1.06 7.00 7.27 N/A VBFS362F 13.12 15.83 8.85 7.27 N/A VBFS363F 13.12 15.83 8.85 7.27 N/A VBFS36F 17 18.20 12.68 7.57 N/A Non-fusible, Flange Mounted VBNFS361F 9.79 11.78 7.00 7.27 N/A VBNFS362F 9.79 11.78 8.85 7.27 N/A VBNFS363F 9.79 11.78 8.85 7.27 N/A VBNFS36F 10.77 12.00 12.68 7.57 N/A B A D C Dimension C for panel mounted switches indicates the minimum width from the left hand edge of the switch mounting pan to the right hand inside surface of the enclosure. -10