Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en

Similar documents
Drain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element

Weight (kg) Model L92C- P-ETN. N/en

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

BL68 - Olympian Plus plug-in system Filter/regulators and lubricators

F84G - Excelon Plus Modular System General purpose filter

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

T84T - Excelon Plus Modular System 3/2 shut-off valve

F84C - Excelon Plus Modular System Oil removal filter

F84V - Excelon Plus Modular System Oil vapour removal filters

FLEXIBILITY, VALUE AND EASE OF USE NO TOOLS REQUIRED

T84T - Excelon Plus Modular System 3/2 shut-off valve

L84M, L84C - Excelon Plus Modular System Micro- and oilfog lubricator

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.

P72F P74F P74F-AD P7 F- - 1/4" (72) 2 3/8" 3 1/2" (74) 4 3/4" (74) 6. ISO G parallel

F64C, F64H - Olympian Plus Plug-In System Puraire high efficiency coalescing filter

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Nugget 40, V08 series

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

Orders. Combination shut off valve, filter/regulator and lubricator. Models. BL92 ø 8 mm, G1/4. For further information

25000, 4/2 Direct solenoid actuated poppet valves

AIR PREPARATION PRODUCTS. Table of Contents

F64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

P64F - Olympian Plus plug-in system Soft start/dump valves

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

L84M, L84C - Excelon Plus Modular System Micro-Fog and Oil-Fog Lubricators

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat

AUTO STAR with central connector M12x1

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

N/** поставка оборудования для подготовки воздуха

Operating pressure (bar) kv factor (m 3 /h) *3)

60 series, 2/2 or 3/2 Ball valve

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

Brass ball valves 60 series

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

Air Preparation Products 652 Series Filter Regulator (FR) for Process Industry Applications

Installation Components AirCare Air Preparation Systems

LRM/55401/M, Roundline cylinder Magnetic piston, double acting

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

Weight (kg) Dimension No. G1/4 Exhausting None 0,2 1 T F2BG *1) Interface Exhausting None 0,4 3 T10-N10-D2BN

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

LPRA/182000/M, ISO cylinder Magnetic piston, double acting

, /2 Soft start ( soft clutch ) valve

M/1000, Heavy Duty Cylinders Double Acting

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

P3Y Series Air preparation system. 3/4 & 1 Body ported

PRA/842000/M, PRA/ Clean Line cylinder Magnetic or non-magnetic piston, double acting

M/44000/M. LINTRA Rodless cylinders Magnetic piston Double acting Ø 25 to 40 mm

97100 NAMUR. Technical data

Air Preparation Products

RM/900/M Heavy duty cylinders Ø 1 1/4... 4

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

LRA/8000/M/EX, LRA/8000/EX, ISO cylinder Magnetic & Non-magnetic piston, double acting

24010, 3/2 Direct solenoid actuated poppet valve

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

Our policy is one of continued research and development. We therefore reserve the right

Excel V03, V04 and V05 Series

AIR PREPARATION PRODUCTS

Accessories for Filters, Regulators, and Lubricators

EXCELON. PATENTED QUIKCLAMP CONNECTION SYSTEM Simple, speedy assembly of accessories and combination units

Air service units series X G1/4 to G3/4

C D J K N N/UK /02. Our policy is one of continued research and development. We therefore reserve the right

M/1525, M/1540. Fixed Range Positioner Cylinders Double Acting 2 1 /2", 4" bore. Robust and reliable for long, maintenance free life

NFPA Double acting imperial cylinders

82 series Brass compression fittings

83 series Brass compression fittings

Series IW. Filter Regulator

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS

97105 Inline. Ordering information. Technical data. Accessories See page 5

Air preparation units

Strokes (mm) N/en

Series AN /Series AMC

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted

Our policy is one of continued research and development. We therefore reserve the right to amend,

Installation Components AirCare Air Preparation Systems

Moduflex FRLs. Moduflex40 P3H Series 1/8 and 1/4 ported. Moduflex60 P3K Series 3/8 and 1/2 ported. Moduflex80 P3M Series 1/2, 3/4 and 1 ported

Filters, regulators, and lubricators

VR61, 3/2, 2 x 3/2, 5/2 or 5/3 Solenoid and pilot actuated spool valves

Valve Islands, V22 Series Sub-base Mounted 2 x 3/2, 5/2 and 5/3 Valves Solenoid Actuated with Wireway

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

F.R.L. unit modular type

LAP4, LAP8. Pneumatic linear drive sizes 4 and 8

Series Airplus Size 1

High pressure valves. 80 to 350 bar

Air preparation units

VP23. 3-way proportional pressure control valve Directly-controlled seat valve with μp-driven pressure control G 1/4 to G 3/4 Nominal diameter 8/16

3000 Series filters 3/4" and 1" Ports

R1000/R3000/R4000/R8000 Series

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

Parker Global Air Preparation System

SBM TECHNOLOGY Cooling / Air Recovery Valve

Transcription:

BG, BB Excelon Pro General Purpose filter/regulator ø... mm, G /...G / Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air Operating pressure: bar max. (Manual drain) bar max. (Automatic drain) Element: µm Fluid/Ambient temperature: - C... + C Air supply must be dry enough to avoid ice formation at temperatures below + C. Drain: Automatic drain operating conditions (float operated): Bowl pressure required to close drain: >, bar Bowl pressure required to open drain:, bar Minimum air flow required to close drain:, m /s ( l/min) Manual operation: depress pin inside drain outlet to drain bowl Materials Body: PBT Bonnet: PBT Valve elastomer: Geolast Diaphragm: Nitrile Transparent bowl: Polycarbonate Element: Sintered polypropylene Gauge: Brass boby, plastic face Elastomers: Bowl O-ring - Neoprene All others - Nitrile Technical data, standard model - relieving Symbol Port size Connector Pressure range (bar) Flow (dm /s) * Element (µm) Drain Gauge Weight (kg) G / With mounting bracket,... ( l/min) Manual Included, BG-GK-QT-RMG Model G / With mounting bracket,... ( l/min) Automatic Included, BG-GK-AT-RMG * Typical flow with bar inlet pressure,, bar set pressure and a bar drop from set. Options selector B - K- T-RMG Flow direction From left to right (standard) G From right to left B Connector with mounting bracket mm Push-in fitting D mm Push-in fitting D mm Push-in fitting AD mm Push-in fitting BD G / G G / G G / G Connector without mounting bracket G/ V Connector Without NN Drain Manual Automatic Q A / N/en...

BG, BB Flow characteristics Inlet pressure: bar, filter element: µm Port size: G/ bar Outlet pressure,,,,, dm /s l/min Air flow Service kit Service kit Automatic drain Gauge set bar/psi Gauge set bar/mpa Automatic drain bowl set Manuel drain bowl set BG-KITR -R KIT- *) KIT- *) KIT- KIT- *) Part number = five gauges, O-ring and screwdriver N/en... /

BG, BB Component parts and accessories Push-in fitting connector with mounting bracket with mounting bracket without mounting bracket Port size G/ - KIT-G - G/ - KIT-G KIT-V G/ - KIT-G - ø mm KIT-D - - ø mm KIT-D - - ø mm KIT-AD - - ø mm KIT-BD - - Wall mounting Quick connector Porting block Plugs not included Lockout/shut-off valve with exhaust port Locking plate Locking plate for gauge side only Silencer for shut-off valve Tamper resistant cover and seal wire - - - TT-NNN-BN -/X *) -/X *) TM - *) pieces Warning Locking plates MUST be in place before pressurizing any Excelon Pro unit. / N/en...

BG, BB Filter/regulator with wall mounting bracket,,,, #, / #,, /,, # Minimum clearance required to remove bowl Connector Dimensions / and / threaded connectors shown. See below for port-to-port dimensions for additional connectors. PIF Connector Port-to-port mm, mm mm, mm G/, G/, G/,, Filter/regulator without mounting bracket, G / port size, G /, N/en... /

BG, BB Wall mounting Porting block Lockable/shut off valve G /,, G / G /,, M exhaust port Lever lockable only in closed position. Lock slide accepts ø mm padlock/shackle. Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in pneumatic systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / N/en...