M-5000TG/5700TG Steam and Cold Water Mixing Unit

Similar documents
M-5000TG/5700TG Steam and Cold Water Mixing Unit

M-5000/5700 Instant Hot Water Maker

Strahman. Since Strahman full line catalogue Hoses Nozzles Hot Water Makers Mixing Units & Accessories Accessories

PISTON DIVERTER VALVES

IN-LINE DISC & PISTON VALVES

WEDGE & SLAB GATE VALVES

ID & IP SERIES IN-LINE DISC AND PISTON VALVES

TRUNNION MOUNTED METAL SEATED BALL VALVES

VD SERIES VESSEL & REACTOR VALVES DISC VALVES

Setting the Standard. for Reliability. Since The Originator of Piston-Type Sampling Valves ISO 9001:2000. PED Compliant

SV SERIES THE ORIGINATOR OF PISTON-TYPE SAMPLING VALVES

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

TECHNICAL INSTRUCTIONS #11 REGULATOR Single Seat - Bronze Trim - Composition Disc

Technical Instructions

Before installation these instructions must be fully read and understood

WARNING Carefully Read These Instructions Before Use

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

CONTROL VALVES. Installation, Maintenance & Operating Instructions. Read these instructions carefully before installation or servicing.

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Baumann Way Control Valve

Double Offset High Performance Butterfly Valve

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Instructions for Installation, Operation, Care and Maintenance

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

INDUSTRIAL SPRAY NOZZLE GUN FOR GENERAL APPLICATIONS LIQUIDS. 143

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Fisher 657 Diaphragm Actuator Sizes and 87

Technical Data PRESSURE (PSI) DIMENSIONS inches AND WEIGHTS pounds

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

Insta-Valve 250 Patriot TM

Installation Guidelines

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

OPERATING AND MAINTENANCE MANUAL

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

A. This Section includes general duty valves common to several HVAC piping systems.

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

Fisher 3024C Diaphragm Actuator

1 - S-2251 Showerhead 6 - S-2288 Showerhead AP - Anchor Plate (S-2280 Showerhead Only)

TECHNICAL INSTRUCTIONS Heavy Duty Bronze Series

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Operating & Maintenance Manual For Steam Conditioning Valve

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

INSPECTION & MAINTENANCE BULLETIN ARI 1301/1302 1" Plug Type Angle Valves

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

INSTRUCTION MANUAL AND PARTS LIST FOR SERIES 8L-630J AND 630M WARNING

Installation Instructions

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

KOSO HAMMEL DAHL CONTROL VALVES

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

TECHNICAL SERVICE MANUAL

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

KOSO HAMMEL DAHL CONTROL VALVES. Installation, Maintenance & Operating Instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL AOP SERIES D TRUNNION BALL VALVE, 2 FP 6 RP

CONTROL VALVES SINGLE PORTED CLASSES DL, DDL, DOS, DDOS

Model DF233 Control Valve

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Crispin Valves Operating Guide. Crispin

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Model DFR 026 Rotary Actuator

I & M Mark 708. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & 14M Actuator and Motor Valve

IOM-CleanFLOW TM. CleanFLOW Series Ball Valves. SV F Flow Controls I N C O R P O R A T E D

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001

KLINGER Piston Valves KVN DN PN 16 I/III with valve ring KX-GT Modul

Service Handbook. High-Pressure Washer Pump

Sachs 48mm Closed Cartridge fork Service Manual

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

VP12 High Viscosity Piston Pump

250L Cartridge Dual Seal

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

Service Manual Air Tech Second Stage

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

LIL GATOR TYPE VLG CONTROL VALVE SIZES ½ THROUGH 2

Service Handbook HD /97

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

CV3000 Series Control Valves Model: AMT. User s Manual

Installation, Operation, and Maintenance Manual GENERAL VALVE GENERAL VALVE TRUSEAL / IOM-GEN-TRUSEAL. Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS D SERIES TABLE OF CONTENTS

Bray/McCannalok High Performance Butterfly Valve Operation and Maintenance Manual

Transcription:

M-5000TG/5700TG Steam and Cold Water Mixing Unit Installation, Operating and Maintenance Instructions Last Updated: August, 2014 Strahman Valves, Inc. USA Headquarters 2801 Baglyos Circle Bethlehem, PA 18020 Phone: (484) 893-5080 Fax: (484) 893-5099 www.strahmanvalves.com QMS12.004 ISO 9001 Management System Registered

Maintenance of Model M-5000TG/5700TG Steam and Cold Water Mixing Unit M-5000TG, M-5700TG SERIES FOR STEAM AND COLD WATER These units produce hot water instantly from a steady supply of steam and cold water. All mixing units-hose stations in the M-5000/M-5700 series are equipped with a dial-type gauge that indicates the wash water s exact temperature. Users can easily regulate the temperature by turning the unit s steam and coldwater valves. INSTALLATION INSTRUCTIONS Strahman Mixing Units are designed for wall mounting and are provided with necessary hexagonal spacers tapped for 3/8 bolts. They can be mounted on any type of wall by means of toggle bolts, expansion bolts or other conventional method, the only requirement being that from 5/8 to 1 of full thread be left projecting from the wall. ( See Figure 1) 1. Using the template provided (see attached drawing), layout and install mounting studs in wall. 2. Slide Wall plate (part 11) over stud and run on hex spacers and pulls up snug. 3. Insert short cap screw thru center mounting lug of unit and attach to corresponding spacer on wall, ALSO thru temperature gage holder on M5000 unit. 4. Complete assembly by inserting the two long cap screws thru hose rack connector (part 4), lock washer (part 3) and thru mounting lugs on unit. Pull up all cap screws tight and the unit is ready for necessary pipe ¾ NPT. It is important that the lock washer is placed in the proper place as this insures rigidity of installation. Figure 1: M-5000/M-5700 Installation. 1

OPERATING INSTRUCTIONS Follow your company safety precautions during mixing unit operation. If unit is not shut down the steam will boil the water in the unit and cause steam to come from nozzle when first turned on. To turn M-5000/M-5700 on, follow the steps listed below: 1. Strahman recommends steam traps are installed and functioning properly. 2. Turn on the water valve, located on the right side of the unit, counter clockwise. 3. Squeeze spray nozzle until you get full water flow. 4. Slowly turn on the steam valve, located on the left side of the unit, counter clockwise until you reach the desired water temperature outlet. 5. If unit will be idled for a long period of time the unit, along with the hose, should be drained. This will help avoid a build-up of deposits. The hose should be stored on the hose rack when not in use. See Table 1 for easy control valves identification. NOTE: If you do not get the desired water temperature outlet, turn the water valve handle clockwise until you reach the desire temperature. Figure 3: Turn Off control valves clockwise to turn M-5000/M-5700. COLOR STEAM WATER M-5000 RED BLACK M-5700 ORANGE BLUE Table 1: Control Valves Color Identification For more information, please contact your Strahman representative. MAINTENANCE INSTRUCTIONS Figure 2: Turn control valves counter clockwise to turn M-5000/M-5700 on. To turn M-5000/M-5700 off, follow the steps listed below: 1. Shut off the steam valve completely. 2. Shut off the water valve completely. 3. Relieve any pressure in the unit by opening the spray nozzle. CAUTION: If internal pressure is not relieved when shutting the unit off, steam will come out at the spray nozzle when first open. Shut M-5000/M-5700 down when unit is not being used. The Strahman Instant Hot Water Maker must be maintained properly in order to get the best results. The steam passing through the unit is controlled by a steam poppet (5), which should be replaced as soon as it becomes worn, This can easily be done by following the steps below. (See page 3 & Table 2) 1. First close the control valves, and allow the unit to cool. 2. Then remove the hex nut (21) on the left side of the unit. 3. Remove the poppet (5) guide assembly (parts 20, 26, 27 & 28) the assembly should easily slide out of the unit with little effort. 4. The poppet can now be removed using the special tool furnished in the M-5000 Service Kit. (See Page 3) 2

5. The new poppet can now be installed using the same tool, guide assembly, and guide nut (torque guide nut to 75 Ft- Lbs 100 Ft-Lbs Max.) 6. The unit is now ready for use. In extremely sever cases it may be necessary to replace the poppet seat, (7). This can be done with the poppet and guide assembly removed as in the previous steps. 1. Use the Poppet seat tool 2. Insert tool and turn counter clock-wise to loosen and remove the poppet seat. 3. Reinstall the poppet seat by turning the seat tool in clockwise until snug. PART NO. PARTS PART M-5700 MATERIAL M-5000 MATERIAL 1 BODY (includes parts 6 and 7) SST 316 BRONZE 2 HOSE RACK CAP SCREW (not shown) SST 304 SST NOTE: If leakage occurs at the poppet guide assembly, immediately turn off both control valves. Relieve any pressure in the unit by opening the spray nozzle. Allow the unit to cool down before removing the poppet guide nut. Remove poppet guide nut and poppet guide assembly (See Figure 4). Clean the area where the poppet guide seats in the M-5000 body. Clean the seating area of the poppet guide and apply pipe dope. Reinstall the poppet guide assembly and poppet guide nut. Torque the poppet guide nut to 75 ft-lbs. Do not exceed 100 ft-lbs. Follow this procedure whenever the poppet guide assembly is removed. 3 HOSE RACK LOCK WASHER (not shown) 4 HOSE RACK CONNECTOR (not shown) SST 410 SST 303 5 STEAM POPPET (L, M, H) SST 303 SST 6 STEAM JET SST 416 SST SST BRASS 7 POPPET SEAT SST 304 BRONZE 8 HOSE RACK (not shown) SST 302 SST 10 SPACER (not shown) SST 416 SST 11 WALL PLATE (not shown) SST 304 BRASS 12 BALL CHECK UNION NUT SST 304 BRASS 13 BALL CHECK VALVES (includes part 36) SST 303 18 WATER CHAMBER SST 303 SST 19 WATER CHAMBER HOUSING (includes part 35) SST 304 BRASS/SST ALUMINUM SILICONE BRONZE BRASS 20 POPPET GUIDE SST 304 BRASS 21 POPPET GUIDE NUT SST 303 BRASS 22 BODY NUT SST 303 BRONZE 25 SET SCREW SST 304 SST 26 POPPET SPRING SST 302 SST 27 GUIDE EXTENSION SST 416 SST 28 PUSHER SST 303 SST 31** TEMP GAUGE PLATED BRASS CHROME Figure 4: M-5000/M-5700 poppet guide seat assembly. 32 BLENDING CHAMBER SST Bronze (269) 35 0 SEALING RING FOR WATER CHAMBER HOUSING EPMD 36 BALL CHECK GASKET COPPER, PTFE COATED E5 15-80-2Q75 COPPER Sold as a complete unit. **Temperature gauge: 40-120 C/100-250 F. 3

Strahman Water-Saver Spray Nozzle Also available in stainless steel. S 8 S 31 8 29 32 18 22 30 18 30 24 22 24 6 28 20 6 21¾ Garden Hose Thread 21¾ Swivel Garden Hose Thread 21 ½, 5 /8, ¾ 21S ½, 5 /8, ¾ Instruction for Servicing (Caution: Not for use on steam hose) The entire working parts of the Strahman Water-Saver Spray Nozzle are contained in a single cartridge (F, J, M, S). This cartridge can be removed by: 1. Remove rubber cover (20) by slipping the rubber off the back of nozzle and pulling over front. 2. Remove lever arm screw and nut (24) and remove lever arm (6) 3. Unscrew lock screw (30) and extract the cartridge from back end of nozzle with cage (18). 4. To insert new cartridge, reverse above procedure. 5. Be sure when replacing cage (18) to place cut-away part of cage facing downward, so lever arm (6) can be inserted. 6. Be sure lever arm is placed ahead of stem guide (31) on cartridge unit. 7. To replace cover wipe body with detergent, insert nozzle end first then handle into cover. Use a round ended tool approx. 3/8 in diameter to stretch cover over back. Sharp tools can cut cover. 20B Black 20R Red 20W White Parts List F Renewable Cartridge Unit Model F-90 Series SF Renewable Cartridge Unit Model F-90 SS Series J Renewable Cartridge Unit Model S-80 Series SJ Renewable Cartridge Unit Model S-80 SS Series M-70 Renewable Cartridge Unit Model M Series (shown) S-70 Renewable Cartridge Unit Model S Series 6. Lever Arm 8-S. Stainless Steel Seat 18. Cage 20B. Renewable Rubber Cover (Black) 20R. Renewable Rubber Cover (Red) 20W. Renewable Rubber Cover (White) 21. Hose Adapter (½, 5 /8, ¾ ) (¾ Garden Hose Thread) 21S. Swivel Hose Adapter (½, 5 /8, ¾ ) (¾ Garden Hose Thread) 22. Lever Arm Bushing 24. Lever Arm Screw and Nut 28. Lock Rings 29. Body 30. Lock Screw 31. Stem Guide 32. Body Sealing O-ring 4

The Strahman Soft Seal Piston Valve V-14-U ¾ Globe (Shown) V-18 ¾ Angle, V-14S (Screwed End) V-65-SU ¾ Globe Stainless Steel V-18-S ¾ Angle Stainless Steel Note: Globe (Union Connection) Valve Shown. Angle Valve Not Shown. PART NO. PART PARTS 1 BODY SCREWED ENDS 1 BODY SCREWED ENDS SS 1 BODY UNION TYPE 3 VALVE RING 4 PISTON 5 SPLITNUT 6 STEM (includes part 7) 14 PACKING GLAND PACKING RING 9 13 6 STEM 10 BONNET SPRING HANDWHEEL NUT HANDWHEEL LOCK WASHER PRESSURE IDENTIFICATION TAG 3/4" SOFT SEAL PISTON VALVE 16 HANDWHEEL 15 PACKING NUT 12 RETAINING RING 7 STEM STOP 11 Spring to be installed in back of piston Large I.D. facing up 7 STEM STOP (set of 6) 8 BONNET NUT 8 LANTERN LANTERN 9 SPRING 10 BONNET Bronze 20 UNION GASKET 5 SPLIT NUT Ring Puller 10 BONNET SS 303 11 BONNET NUT 11 BONNET NUT SS 303 12 RETAINING RING (set of 6) 13 PACKING RING 21 UNION TAIL PIECE 22 1 BODY 4 PISTON 3 VALVE RING WITH O-RING Ring Seater 14 PACKING GLAND 15 PACKING NUT INLET UNION NUT MODEL SHOWN: V-14-U 3/4" GLOBE TYPE (UNION CONNECTION). MODELS AVAILABLE: V-14-S 3/4" GLOBE TYPE (SCREWED ENDS). V-18 3/4" ANGLE TYPE (SCREWED ENDS). SST MODELS: V-65-SU, V-65-SS AND V-18-SS 15 PACKING NUT SS 303 16 BLACK HANDWHEEL 16 RED HANDWHEEL 17 HANDWHEEL NUT (set of 6) 20 UNION GASKET (set of 6) C D C D 20 SPIRAL WOUND GASKET Graphite 21 UNION TAIL PIECE 22 UNION INLET NUT 23 ANGLE RECESSED GASKET A B Note: When installing new spring, splitnut no. 5 and piston no. 4 must be disassembled from stem no. 6. Install new spring over stem against bonnet. Reassemble splitnut and piston. Hold spring against bonnet. Instructions for Use of Tools with Soft Seal Piston Valve Extracting Valve Ring Fig. 1 Fig. 2 Fig. 3 First Remove bonnet and stem assembly by opening valve to To Insert New Valve Ring wide open position and removing bonnet nut and working First Place valve ring, including O-ring, on seating tool as assembly free of body. shown in Fig. 3 and drive into valve body as far as it will Second Insert pulling tool into ring pocket making sure that puller go keeping sealer tool as straight as possible. housing is located evenly on neck of valve body. Slotted Second Drop lantern into body with large I.D. and wider band cap A should rest on lantern as shown in Fig. 1. Rotate until facing up making sure lantern sits evenly on ring. pin B can be pressed into slot and hold while knurled nut C counter clockwise until refusal. Third Before installing bonnet assembly into body, fully retract stem making sure spring is located between Third With an adjustable wrench, turn hex nut D in a clockwise back of piston and bonnet. Install into body. Tighten direction until internal parts are fully extracted, as shown in down bonnet nut until refusal. Fig. 2. Precautions: Make sure ring pocket is free of scale, rust or Fourth Spin hex nut all the way back on so that withdrawn parts can other obstruction before replacing valve ring. Make sure be fully extended from puller housing, then turn knurled nut parts are replaced in same order as removed. C clockwise which will release parts from puller. Base ring no longer necessary (older valves only). 5

Maintenance of Model M-5000TG/5700TG Steam and Cold Water Mixing Unit TEMPLATE FOR MOUNTING M-5000 STRAHMAN INSTANT HOT WATER MAKER THREE 3/8 STUDS N.C. - STUDS MUST STICK OUT 5/8 TO 1 FROM WALL. NOTE: THESE UNITS HAVE SPACERS (10) AND LOCK WASHERS (3) ATTACHED. SPACER MUST BE DETACHED FOR MOUNTING. SPECIAL CARE IS ADVISED FOR THE CENTER SPACER WHICH HOLDS THE TEMPERATURE GAUGE IN PLACE.

The Strahman Family of Products Includes: Wash Down Equipment Strahman offers a full line of mixing units, hose stations, hoses, nozzles, and wash down accessories. Our wash down line is designed for industrial use and is used in a wide variety of industries including food, beverage, pharmaceutical, chemical and other applications. Pre-Rinse Equipment for Commercial Kitchens Strahman offers pre-rinse spray nozzles, handles, hoses, hose reels and Pivot Pro swivel connectors. Designed for use in restaurants, hotels, supermarkets, and all commercial kitchens, food serving and food preparation applications. Sampling Valves Strahman has a full line of sampling valves that produce live samples without exception. Our sampling valves unique design prevents failure caused by sediment or clogging. Drain Valves Strahman Drain Valves are designed to prevent clogging. They are ideal for use in liquid and gas service or with slurries, polymers, and high viscosity fluids that tend to solidify at room temperature. Last Updated: August, 2014 France Savoie Hexapole, F-73420 Mery, France Tel: 33 (0) 4 79 35 78 00 Fax: 33 (0) 4 79 35 78 20 USA Headquarters 2801 Baglyos Circle Bethlehem, PA 18020 Phone: (484) 893-5080 Fax: (484) 893-5099 Toll Free: (877) STRAHMAN www.strahmanvalves.com Germany Kirchstrasse 16, D-77855, Achern, Germany Tel: 49 (0) 7841 6846530 Fax: 49 (0) 7841 6846531