McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

Similar documents
McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay Central Station Air Handler Medium Pressure MSL

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

Complete HVAC Capability

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

Daikin McQuay. Roofpak Applied Rooftop Air Handler. RDS Size 708 Vintage B. Replacement Parts List No Revision F 03/2018

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay Climate Control Singer

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

Daikin McQuay. Destiny Indoor Air Handler. LAH Vintage A. Replacement Parts List No Revision T 10/2017

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Centrifugal Utility Fans - SFD/SFB

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

DESIGN GUIDELINES FANS PAGE 1 of 7

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

BAC, BAF, BAH Central Station Air Handlers

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

REPLACEMENT PARTS MANUAL

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

SECTION AXIAL HVAC FANS

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

Installation, Start-Up and Service Instructions

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

TORIN by: AIRDEX Index Page No.

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

& 12" 96" / TABD CATALOG

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

FILTERED AIR SUPPLY FANS

MAH. Modular Air Handling Unit

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

REPLACEMENT PARTS MANUAL

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

McQuay. Superpak Applied Rooftop Units. RRS, RSS Vintage B. Last Manufactured: Replacement Parts List No Revision I 09/2017

Tubular Centrifugal Fans

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

Transcription:

Replacement Parts List No. 046902100 Revision D 01/2015 McQuay Central Station Air Handler LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL 137-172 Vintage D LML, LSB, MMM, MSB 137-172 Vintage E Last Manufactured: 1999 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Table of Contents Parts List Revision History... 3 Model Number Nomenclature... 4 Serial Number Nomenclature... 5 Unit Code Index...6-8 Coil Notes... 9 Contractor Coil Code Strings... 9 Fan Section Assembly Diagram... 10 Motor Section Components & Fan Discharge Configuration Diagram... 11 Blower Housing Components... 12 Pillow Block Bearings & Fan Shafts... 13 Blower Wheel Diagram & Components... 14 Variable Inlet Vanes (Airfoil Fans Only) Inlet Vane & Linkage Assemblies... 15 Vane Linkage Diagram & Components... 16 Low Leak Dampers Diagram & Assemblies... 17 Components... 18 RPL 469021 / Page 2

Parts List Revision History Revision Date Description A 11/96 Updated RPL layout to be consistant w/ OnLine format. B 4/01 Changed to single page format. C 5/10 Converted file to current software and corrected formatting errors. Updated Cover and Revision page with current design logo. Reorganized form into sections and updated TOC. Page 4: Added Model Number Nomenclature section. Page 5: Added Serial Number Nomenclature section. Page 6-8: Added Unit Code Index section. Page 9: Added Coil Section. Page 11: Changed footnote #1 to "Part numbers ordered per Code Item on original G.O. Contact McQuay Parts with model and serial number information so the needed part(s) can be correctly identified." Page 13: Changed page title from "Pillow Block Bearings and Fan Shafts Components" to "Pillow Block Bearings & Fan Shafts". Page 17, 18: Added Low Leak Damper section. D 1/15 Cover, Rev pg.: Updated to Daikin Applied logo format. Various: Changed "McQuay Parts" & "McQuay" to "Daikin Applied". Fixed issue w/ graphics import to CC 2014. Page 9: Rewrote coil notes. Reorganized page contents. Updated TOC. Page 17: Rewrote footnote #1. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 RPL 469021 / Page 3

Model Number Nomenclature LSL 1 37 D H Unit Type First Letter = Blower Section Second Letter = Unit Type Third Letter = Coil Section LSL = Low Pressure, Single Zone, Low Pressure MSL = Medium Pressure, Single Zone, Low Pressure LML = Low Pressure, Multi Zone, Low Pressure MMM = Medium Pressure, Multi Zone, Medium Pressure LWL = Low Pressure, Water Sprayed Coil, Low Pressure MWL = Medium Pressure, Water Sprayed Coil, Low Pressure LYF = Low Pressure, Ventilating, Draw Thru LHD = Low Pressure, Heating and Ventilating, Draw Thru LSB = Low Pressure, Single Zone, Blow Thru MSB = Medium Pressure, Single Zone, Blow Thru Air Intake into Blower Section H = Horizontal Air Intake V = Vertical Air Intake I = Inverted Number of Fans Nominal Coil Face Area (in Square Feet) Vintage RPL 469021 / Page 4

Serial Number Nomenclature 3 Z F 12345 00 Plant Identification 3 = Faribault, MN 9 = Scottsboro, AL Engineering Revision Sequence Number Year of Manufacture A = 1971 R = 1986 B = 1972 S = 1987 C = 1973 T = 1988 D = 1974 U = 1989 E = 1975 V = 1990 F = 1976 W = 1991 G = 1977 X = 1992 H = 1978 Y = 1993 J = 1979 Z = 1994 K= 1980 5 = 1995 L = 1981 6 = 1996 M = 1982 7 = 1997 N = 1983 8 = 1998 P = 1984 9 = 1999 Q = 1985 Month of Manufacture A = January J = September B = February K = October C = March L = November D = April M = December E = May F = June G = July H = August RPL 469021 / Page 5

Unit Code Index Code 03= Fan Wheel and Housing A= Forward Curved Steel Wheel B= Forward Curved Aluminum Wheel C= Forward Curved Hot Dipped Galvanized Wheel D= Airfoil Wheel E= Forward Curved Steel Wheel with Mechanical Speed Control F= Airfoil Wheel with Mechanical Speed Control L= Forward Curved Wheel with Variable Inlet Vanes V= Airfoil wheel with Variable Inlet Vanes Code 04= Unit Arrangement Digit 1, Unit Arrangement H= Horizontal V= Vertical I= Inverted Digit 2, Cabinet 1= Standard Fan Cabinet 6= Vertical Discharge (LSB/MSB Only) 7= Vertical Discharge w/ Cabinet Extension (LSB/MSB Only) Digit 3, Unit Options 0= Basic Unit LH Air Intake 1= Basic Unit RH Air Intake 2= Fan & Diffuser Section LH Air Intake (LSB/MSB Only) 3= Fan & Diffuser Section RH Air Intake (LSB/MSB Only) 4= Internal Face & Bypass LH Air Intake 5= Internal Face & Bypass RH Air Intake 5= Internal Face & Bypass Top or RH Duct; RH, Bottom or Top Air Intake (LHD Only) 6= External Face & Bypass LH Air Intake 6= External Face & Bypass Top or LH Duct; LH, Bottom or Top Air Intake (LHD Only) 7= External Face & Bypass RH Air Intake 7= External Face & Bypass Top or RH Duct; RH, Bottom or Top Air Intake (LHD Only) Digit 4, Section Options 1= No Access or Auxiliary Coil Section 1= No Access or Auxiliary Coil Section w/ 1 or 2 Row Coil (LHD Only) 1= No Auxiliary Coil Section (LSB/MSB Only) 2= Leaving Air Access Section, no Auxiliary Coil Section 3= No Access Section w/ Auxiliary Coil Section 4= Entering Air Acess Section w/ Auxiliary Coil Section 5= Leaving Air Access Section w/ Auxiliary Coil Section 7= Leaving Air Access Section w/ Auxiliary Coil Section when Unit Option (Digit 3) is 6 or 7 8= No Access or Auxiliary Coil section w/ a 3 or 4 Row Coil Code 05= Mounting Arrangement A= Top Mounting Holes B= Bottom Mounting Holes Code 06= Fan Discharge and Motor Location 1= CH 4= CCBH 7= CD 2= CCH 5= CU 8= CCD 3= CBH 6= CCU Code 07= Not A Central Station Air Handler Code Code 08= Motor Size A=.25 HP F= 1.5 HP L= 10.0 HP Q= 40.0 HP B=.33 HP G= 2.0 HP M= 15.0 HP R= 50.0 HP C=.50 HP H= 3.0 HP N= 20.0 HP S= 60.0 HP D=.75 HP J= 5.0 HP O= 25.0 HP T= 75.0 HP E= 1.0 HP K= 7.5 HP P= 30.0 HP Code 09= Unit Voltage 11= 115/60/1 21= 230/460/3 29= 230/60/3 12= 200/60/3 27= 460/60/3 37= 575/60/3 16= 115/230/60/1 28= 380/50/3 Code 10= Motor Base and Bearings 1= Rigid base, Ball Bearing 2= Resilient Base, Sleeve Bearing (LSB/MSB Only) 3= Resliient Base, Ball Bearing (LSB/MSB Only) Code 11= Motor RPM and Enclosure A= 1800 RPM, Open Dripproof B= 1800 RPM, Totally Enclosed Fan Cooled C= 1800 RPM, Explosion Proof D= 1800/900 RPM, Two Speed, One Winding E= 1800 RPM, Open Dripproof High Efficiency Code 12= Motor Mounting 1= Factory Mounted Motor 2= With Motor, Field Mounted Code 13= Fan/Fan Mount/Drive Selection Digit 1, Fan and Drive Type Selection A= Standard Forward Curve Fan, Rigid Fan mount, Variable Speed Drive B= Standard Forward Curve Fan, Isolated Fan mount, Variable Speed Drive C= Optional Forward Curve Fan, Rigid Fan mount, Variable Speed Drive D= Optional Forward Curve Fan, Isolated Fan mount, Variable Speed Drive E= Standard Airfoil Fan, Rigid Fan mount, Variable Speed Drive F= Standard Airfoil Fan, Isolated Fan mount, Variable Speed Drive G= Optional Airfoil Fan, Rigid Fan mount, Variable Speed Drive H= Optional Airfoil Fan, Isolated Fan mount, Variable Speed Drive J= Standard Forward Curve Fan, Rigid Fan mount, Fixed Speed Drive K= Standard Forward Curve Fan, Isolated Fan mount, Fixed Speed Drive L= Optional Forward Curve Fan, Rigid Fan mount, Fixed Speed Drive M= Optional Forward Curve Fan, Isolated Fan mount, Fixed Speed Drive N= Standard Airfoil Fan, Rigid Fan mount, Fixed Speed Drive P= Standard Airfoil Fan, Isolated Fan mount, Fixed Speed Drive Q= Optional Airfoil Fan, Rigid Fan mount, Fixed Speed Drive R= Optional Airfoil Fan, Isolated Fan mount, Fixed Speed Drive Digit 2 & 3, Drive Selection Contact Daikin Applied with model and serial number information in order to identify the needed part(s). Digit 4, Fan Discharge 1= Code 06 equals 1, or 2 2= Code 06 equals 3, or 4 3= Code 06 equals 5, or 6 4= Code 06 equals 7, or 8 Digit 4, Fan Discharge (LSB/MSB Only) 1= Code 07 equals 1 2= Code 07 equals 2 3= Code 07 equals 3 4= Code 07 equals 4 RPL 469021 / Page 6

Unit Code Index, Continued Code 14= Lubrication Lines & Insulation 1= Standard Lube lines 1", 3/4# Insulation 2= Standard Lube lines No Insulation 3= Standard Lube lines 1", 1 1/2# Insulation 4= Standard Lube lines 1", 3# Insulation 5= Copper Lube Lines 1", 3/4# Insulation 6= Copper Lube lines No Insulation 7= Copper Lube Lines 1", 1 1/2# Insulation 8= Copper Lube lines 1", 3# Insulation A= Standard Lube Lines & Liner Options (LSB/MSB Only. Code 39 must not be YY.) B= Copper Lube Lines & Liner Options (LSB/MSB Only. Code 39 must not be YY.) Code 15= Not A Central Station Air Handler Code Code 16= Accessory Arrangement Digit 1, Accessory Section Code 04= H*** or I*** A= Filter Section Only B, C, D= Filter Section and or Mixing Box with Dampers E, F, G= Filter Section and or Mixing Box without Dampers Digit 1, Accessory Section Code 04= V*** H, K, M= Base Mounted Filter Section and or Mixing Box with Dampers J, L, N= Base Mounted Filter Section and or Mixing Box without Dampers Digit 2, Filter Section 0= No Filters 1= Flat Filters End Removal 2= Flat Filters Right Side or Bottom Removal 3= Flat Filters Left Side or Top Removal 4= Angular Filters 5= Heavy Duty Angular Filters Digit 3, Filter Type 0= None 1= Throwaway 2= Cleanable Low Velocity 3= Cleanable High Velocity 4= Throwaway, 35% Pleated Code 17= Auxiliary Coil Section S= Small Coil L= Large Coil Code 18= Auxiliary Coil Type and Rows For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYY XXXXXXXXX Coil Code 19= Auxiliary Coil Connection Location D= Drive End E= Opposite Drive End Code 20= Standard Coil Section, 1st Coil S= Small Coil L= Large Coil E= Extra Large Coil Code 21= Coil Types and Rows, 1st Coil For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYYYYYYY XXXXXXXXXXXXXX Coil DUMMYD**YYYYYYY= Coil Casing Only Code 22= Coil Connection Location, 1st Coil D= Drive End E= Opposite Drive End Code 23= Standard Coil Section, 2nd Coil S= Small Coil L= Large Coil E= Extra Large Coil Code 24= Coil Types and Rows, 2nd Coil For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYYYYYYY XXXXXXXXXXXXXX Coil DUMMYD**YYYYYYY= Coil Casing Only Code 25= Coil Connection Location, 2nd Coil D= Drive End E= Opposite Drive End Code 26= Standard Coil Section, 3rd Coil S= Small Coil L= Large Coil E= Extra Large Coil Code 27= Coil Types and Rows, 3rd Coil For coil features see Contractor Coil codes in Unit Coil Section. YYYYYYYYYYYYYY XXXXXXXXXXXXXX Coil Code 28= Coil Connection Location, 3rd Coil D= Drive End E= Opposite Drive End Code 29= Optional Features A= Gasketed Damper Blades on Mixing Box & Bypass Dampers C= Flex Connector on Blower Intake D= Flex Connector on Blower Discharge E= Flex Connector on Blower Intake & Discharge F= Stainless Steel Drain Pan or Liner H= Galvanized Steel Moisture Eliminators J= Stainless Steel Moisture Eliminators K= Insulated Mixing Box L= Items A & F M= Enclosed Belt Guard W= Outdoor Construction less Weatherhood RPL 469021 / Page 7

Unit Code Index, Continued Code 30= Plug-In Door (Blower Section) Digit 1, Access Door Location 1= Blower Access Panel 2= Opposite Drive End Digit 2, Access Door Dimensions A= 8" x 9" B= 12" x 24" C= 18" x 24" D= 36" x 48" (Code 30 Digit 1 must be 2) Code 31= Plug-In Door (Coil Section) Digit 1, Access Door Location 6= Drive End 7= Opposite Drive End Digit 1, Access Door Location (LSB Only) 8= Drive End 9= Opposite Drive End Digit 2, Access Door Dimensions B= 12" x 24" C= 18" x 24" Digit 2, Access Door Dimensions (LSB Only) D= Full Hinged B= 12" x 24" C= 18" x 24" Code 32= Miscellaneous Code 33= Not A Central Station Air Handler Code YY Code 34= ARI Approval Code 35= Packaging Code 36= Latest Code Sheet Revision Code 36= Coil or Diffuser Sections Insulation Liners 1" Only (LSB/MSB Only) Digit 1, Type of Liners (LSB/MSB Only) 1= 1", 3/4# Insulation 2= 1", 1 1/2# Insulation 3= 1" 3# Insulation 4= 1", 3/4# Foil Faced Insulation Digit 2, Type of Liners (LSB/MSB Only) P= Perforated Liners S= Solid Liners Code 37= Latest Engineering Revision Code 37, 38= Warranty Codes (LSB/MSB Only) Code 39= Blower Section Liners (LSB/MSB Only) Digit 1, Type of Insulation (LSB Only) A= 2" 1 1/2# Insulation Digit 2, Type of Liner (LSB Only) S= Solid Liner P= Perforated Liner Code 40= Coil Section Liners (LSB/MSB Only) Digit 1, Type of Insulation (LSB Only) A= 2" 1 1/2# Insulation Digit 2, Type of Liner (LSB Only) S= Solid Liner P= Perforated Liner Code 41= Auxiliary Coil Section Liners (LSB/MSB Only) Digit 1, Type of Insulation (LSB Only) A= 2" 1 1/2# Insulation Digit 2, Type of Liner (LSB Only) S= Solid Liner Code 42= Filter Section Liners (LSB/MSB Only) Digit 1, Type of Insulation (LSB Only) A= 2" 1 1/2# Insulation Digit 2, Type of Liner (LSB Only) S= Solid Liner Code 43= Mixing Box Liners (LSB/MSB Only) Digit 1, Type of Insulation (LSB Only) A= 2" 1 1/2# Insulation Digit 2, Type of Liner (LSB Only) S= Solid Liner Code 44= Not A Central Station Air Handler Code Y Code 45= Auxiliary Coil Section Liners (LSB/MSB Only) Digit 1, Type of Insulation (LSB Only) A= 2" 1 1/2# Insulation Digit 2, Type of Liner (LSB Only) S= Solid Liner RPL 469021 / Page 8

Coil Notes & Sample Contractor Coil Code Strings Coil Notes Note: ALL Central Station Air Handlers use "Contractor" style coils. Contractor Coils are ordered as SEPARATE LINE ITEMS on the GO/General Order (Example: 976230-017), so they DO NOT have standard nine digit Daikin Applied part numbers. When a replacement Contractor Coil is required a Contractor Coil Quote needs to be prepared. To quote a replacement Contractor Coil it is necessary to obtain model and serial number information from the unit nameplate and then contact Daikin Applied. If the unit has more than one coil it will be necessary to confirm which coil(s) are needed BEFORE quoting. Note that the sample code strings shown below are incomplete and DO NOT furnish enough information to correctly quote a Contractor Coil. GO and/or serial number information is required in order to properly quote a Contractor Coil. In some instances, coils were manufactured separately from the unit and may have a unique serial number such as 9Z12345-00. A coil with a serial number starting with a "9" was built in Scottsboro AL and may or may not have been installed in a unit before shipment. Sample Contractor Coil Code Strings RPL 469021 / Page 9

Fan Section Assembly Diagram 6 See View A 3 4 5 See View A 2 4 5 7 8 1 View A. Lubrication Line Assembly (Typical) Unit Panel 4 5 Note: Items 4 & 5 must be ordered separately. They are not part of the Lube-line assembly. RPL 469021 / Page 10

Fan Section Motor Section Components & Fan Discharge Configuration Diagram Motor Section Components Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 137 141 150 164 172 N/S MOTOR 1 N/S BELT 1 N/S SHEAVES 1 N/S BUSHINGS 1 N/S MECHANICAL VARIABLE SPEED MOTOR DRIVE ASS'Y. 1 MOTOR MOUNT 1 For fan discharge configurations; Top Horizontal - CW 044886800 1 1 1 1 1 1 Bottom Horizontal - CCW 044886800 1 1 1 1 1 1 Upblast - CW 044886800 1 1 1 1 1 MOTOR MOUNT 1 For fan discharge configurations; Top Horizontal - CCW 046388300 1 1 1 1 1 1 Bottom Horizontal - CW 046388300 1 1 1 1 1 1 Upblast - CCW 046388300 1 1 1 1 1 2 LUBE-LINE ASS'Y. - PLASTIC TUBING 70" LG. (STD.) 028171070 1 1 1 1 1 2 LUBE-LINE ASS'Y. -COPPER TUBING 70" LG. (OPT.) 027926470 1 1 1 1 1 3 LUBE-LINE ASS'Y. - PLASTIC TUBING 188" LG. (STD.) 028171188 1 1 3 LUBE-LINE ASS'Y. - COPPER TUBING 188" LG. (OPT.) 027926688 1 1 3 LUBE-LINE ASS'Y. - PLASTIC TUBING 198" LG. (STD.) 028171198 1 1 1 3 LUBE-LINE ASS'Y. - COPPER TUBING 198" LG. (OPT.) 027926698 1 1 1 4 GREASE ZERK (ALL UNITS) 2 000109800 2 2 2 2 2 5 WASHER - FOR GREASE ZERK 2 040500308 2 2 2 2 2 N/S= Not shown on diagram. 1 Drive parts are ordered per Code Item on original G.O. Contact Daikin Applied with model and serial number information so the needed part(s) can be correctly identified. 2 Must be ordered separately, as they are not part of the Lube-line assembly. Fan Discharge Configuration Diagram 3 Top Horizontal Bottom Horizontal Upblast Clockwise Counterclockwise 3 View From Motor Side Of Unit RPL 469021 / Page 11

Fan Section Blower Housing Components Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 137 141 150 164 172 BLOWER HOUSING Forward Curve Fans Only - Includes Inlet Funnels 6 27" FAN 046192800 1 6 30" FAN 046192900 1 1 6 33" FAN 046193000 1 1 6 36" FAN 046193100 1 1 1 6 40" FAN 046193200 1 1 CUTOFF PLATE Forward Curve Fans Only N/S 27" FAN 030030102 1 N/S 30" FAN 030030103 1 1 N/S 33" FAN 029309800 1 1 N/S 36" FAN 029309900 1 1 1 N/S 40" FAN 029310001 1 1 BLOWER HOUSING Airfoil Fans Only - Includes Standard Inlet Funnels 6 27" FAN 046197001 1 6 30" FAN 046197301 1 1 6 33" FAN 046197601 1 1 6 36" FAN 046197901 1 1 1 6 40" FAN 046198201 1 1 Airfoil Fans Only - Includes Variable Inlet Vanes 6 27" FAN HORIZONTAL DISCHARGE 046197002 1 6 27" FAN UPBLAST DISCHARGE 046197100 1 6 30" FAN HORIZONTAL DISCHARGE 046197302 1 1 6 30" FAN UPBLAST DISCHARGE 046197400 1 1 6 33" FAN HORIZONTAL DISCHARGE 046197602 1 1 6 33" FAN UPBLAST DISCHARGE 046197700 1 1 6 36" FAN HORIZONTAL DISCHARGE 046197902 1 1 1 6 36" FAN UPBLAST DISCHARGE 046198000 1 1 1 6 40" FAN HORIZONTAL DISCHARGE 046198202 1 1 6 40" FAN UPBLAST DISCHARGE 046198300 1 1 N/S = Not shown on diagram RPL 469021 / Page 12

Fan Section Pillow Block Bearings & Fan Shafts Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 137 141 150 164 172 PILLOW BLOCK BEARINGS Forward Curve Fans Only 7 1.687" BORE DIA. 27" LOW PRESS. FAN 020648617 2 7 2.187" BORE DIA. 27" MED. PRESS. FAN 020648606 2 7 1.937" BORE DIA. 30" LOW PRESS. FAN 020648618 2 2 7 2.187" BORE DIA. 30" MED. PRESS. FAN 020648606 2 2 7 2.187" BORE DIA. 33" LOW PRESS. FAN 020648606 2 2 7 2.438" BORE DIA. 33" MED. PRESS. FAN 020648607 2 2 7 2.187" BORE DIA. 36" LOW PRESS. FAN 020648606 2 2 2 7 2.688" BORE DIA. 36" MED. PRESS. FAN 020648608 2 2 2 7 2.187" BORE DIA. 40" LOW PRESS. FAN 020648606 2 2 7 2.688" BORE DIA. 40" MED. PRESS. FAN 020648608 2 2 Airfoil Fans Only 7 2.187" BORE DIA. 27" FAN 020648606 2 7 2.437" BORE DIA. 30" & 33" FAN 020648607 2 2 2 7 2.688" BORE DIA. 36" FAN 020648608 2 2 2 7 2.938" BORE DIA. 40" FAN 020648609 2 2 FAN SHAFTS Forward Curve Fans Only 8 1.687" DIA. 54.00" LG., 27" LOW PRESS. FAN 066282202 1 8 2.187" DIA. 53.81" LG., 27" MED. PRESS. FAN 035287901 1 8 1.937" DIA. 59.50" LG., 30" LOW PRESS. FAN 066392902 1 1 8 2.187" DIA. 58.00" LG., 30" MED. PRESS. FAN 030570301 1 1 8 2.187" DIA. 62.00" LG., 33" LOW PRESS. FAN 032423101 1 1 8 2.438" DIA. 62.00" LG., 33" MED. PRESS. FAN 032586301 1 1 8 2.187" DIA. 67.12" LG., 36" LOW PRESS. FAN 046326501 1 1 1 8 2.688" DIA. 67.12" LG., 36" MED. PRESS. FAN 032586201 1 1 1 8 2.187" DIA. 72.36" LG., 40" LOW PRESS. FAN 046326601 1 1 8 2.688" DIA. 72.36" LG., 40" MED. PRESS. FAN 032586401 1 1 Airfoil Fans Only 8 2.187" DIA. 53.81" LG., 27" FAN 035287901 1 8 2.437" DIA. 57.88" LG., 30" FAN 033172901 1 1 8 2.437" DIA. 62.00" LG., 33" FAN 032586301 1 1 8 2.688" DIA. 67.12" LG., 36" FAN 032586201 1 1 1 8 2.938" DIA. 72.36" LG., 40" FAN 032586501 1 1 RPL 469021 / Page 13

Fan Section Blower Wheel Diagram & Components NOTES: LSL, LML, LWL, LYF, LHD, LSB = Low Pressure Blower Fan Components Only. MSB, MSL, MMM, MWL = Medium Pressure Blower Fan Components Only. Smallest fan wheel per unit size is standard fan size; larger fan wheel is optional fan size. G.O. Code 13 = A***, B****, J***, K*** are standard forward curve fans. E***, F***, N***, P*** are standard airfoil fans. C***, D***, L***, M*** are optional forward curve fans. G***, H***, Q***, R*** are optional airfoil fans. FORWARD CURVE FAN WHEEL (Single Wheel Per Fan) AIRFOIL FAN WHEELS (Two Wheels Per Fan) Note: Direction of wheels determined by facing hub end of each wheel. 10 CLOCKWISE 9 COUNTER-CLOCKWISE 11 Rotation Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 137 141 150 164 172 Forward Curve Fans Only 9 BLOWER WHEEL 27" LOW PRESS. FAN 024061101 1 9 BLOWER WHEEL 27" MED. PRESS. FAN 024061111 1 9 BLOWER WHEEL 30" LOW PRESS. FAN 024061103 1 1 9 BLOWER WHEEL 30" MED. PRESS. FAN 012727435 1 1 9 BLOWER WHEEL 33" LOW PRESS. FAN 012725735 1 1 9 BLOWER WHEEL 33" MED. PRESS. FAN 012727939 1 1 9 BLOWER WHEEL 36" LOW PRESS. FAN 024061107 1 1 1 9 BLOWER WHEEL 36" MED. PRESS. FAN 012728343 1 1 1 9 BLOWER WHEEL 40" LOW PRESS. FAN 024061112 1 1 9 BLOWER WHEEL 40" MED. PRESS. FAN 024061110 1 1 Airfoil Fans Only Note: Each Airfoil Fan consists of two blower wheels: 1 clockwise (CW) and 1 counterclockwise (CCW). 10 BLOWER WHEEL, CW 27" FAN 066543201 1 10 BLOWER WHEEL, CW 30" FAN 066543203 1 1 10 BLOWER WHEEL, CW 33" FAN 066543205 1 1 10 BLOWER WHEEL, CW 36" FAN 066543207 1 1 1 10 BLOWER WHEEL, CW 40" FAN 066543209 1 1 11 BLOWER WHEEL, CCW 27" FAN 066543202 1 11 BLOWER WHEEL, CCW 30" FAN 066543204 1 1 11 BLOWER WHEEL, CCW 33" FAN 066543206 1 1 11 BLOWER WHEEL, CCW 36" FAN 066543208 1 1 1 11 BLOWER WHEEL, CCW 40" FAN 066543210 1 1 RPL 469021 / Page 14

Variable Inlet Vanes Inlet Vane & Linkage Assemblies Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 137 141 150 164 172 VARIABLE INLET VANE ASSEMBLY - DOES NOT INCLUDE LINKAGES 1 N/S 27" FAN, CW 032739300 1 N/S 27" FAN, CCW 032738700 1 N/S 30" FAN, CW 032739400 1 1 N/S 30" FAN, CCW 032738800 1 1 N/S 33" FAN, CW 032739500 1 1 N/S 33" FAN, CCW 032738900 1 1 N/S 36" FAN, CW 032739600 1 1 1 N/S 36" FAN, CCW 032739000 1 1 1 N/S 40" FAN, CW 032739700 1 1 N/S 40" FAN, CCW 032739100 1 1 VARIABLE INLET VANE LINKAGE ASS'Y - INCLUDES RODS, SHAFTS, BEARINGS, HARDWARE, ETC. 2 N/S TOP HORIZONTAL DISCHARGE ONLY 27" FAN 046327001 1 N/S TOP HORIZONTAL DISCHARGE ONLY 30" FAN 046327002 1 1 N/S TOP HORIZONTAL DISCHARGE ONLY 33" FAN 046327003 1 1 N/S TOP HORIZONTAL DISCHARGE ONLY 36" FAN 046327004 1 1 1 N/S TOP HORIZONTAL DISCHARGE ONLY 40" FAN 046327005 1 1 N/S BOTTOM HORIZONTAL DISCHARGE ONLY 27" FAN 046327101 1 N/S BOTTOM HORIZONTAL DISCHARGE ONLY 30" FAN 046327102 1 1 N/S BOTTOM HORIZONTAL DISCHARGE ONLY 33" FAN 046327103 1 1 N/S BOTTOM HORIZONTAL DISCHARGE ONLY 36" FAN 046327104 1 1 1 N/S BOTTOM HORIZONTAL DISCHARGE ONLY 40" FAN 046327105 1 1 N/S UPBLAST DISCHARGE ONLY 27" FAN 046327201 1 N/S UPBLAST DISCHARGE ONLY 30" FAN 046327202 1 1 N/S UPBLAST DISCHARGE ONLY 33" FAN 046327203 1 1 N/S UPBLAST DISCHARGE ONLY 36" FAN 046327204 1 1 1 N/S UPBLAST DISCHARGE ONLY 40" FAN 046327205 1 1 N/S = Not shown on diagram 1 = Variable Inlet Fan consists of two Variable Inlet Vane Assemblies: 1 clockwise (CW) and 1 counterclockwise (CCW). 2 = For individual linkage parts, see Vane Linkage Component listing. RPL 469021 / Page 15

Variable Inlet Vanes Vane Linkage Diagram & Components 14 21 22 19 15 20 16 20 17 Bub. No. Description Part Number Unit Sizes - Pieces Per Unit 137 141 150 164 172 SHAFT - LEFT VANE LINKAGE TO RIGHT VANE LINKAGE 14 1.00" DIA. 51.50" LG. 27" FAN 047783401 1 14 1.00" DIA. 55.62" LG. 30" FAN 047783402 1 1 14 1.00" DIA. 59.74" LG. 33" FAN 047783403 1 1 14 1.00" DIA. 64.87" LG. 36" FAN 047783404 1 1 1 14 1.00" DIA. 70.12" LG. 40" FAN 047783405 1 1 LINKAGE ROD - VANE TO SHAFT BELL ARM 15.50" DIA. 27.45" LG. 27" FAN 035281804 2 15.50" DIA. 31.20" LG. 30" FAN 035281806 2 2 15.50" DIA. 34.20" LG. 33" FAN 035281807 2 2 15.50" DIA. 37.20" LG. 36" FAN 035281808 2 2 2 15.50" DIA. 41.60" LG. 40" FAN 035281810 2 2 16 BEARING FLANGE, 1.00" BORE DIAMETER 020649301 2 2 2 2 2 17 BEARING PLATE 047783100 2 2 2 2 2 19 BELL ARM 046326900 3 3 3 3 3 20 BALL JOINT, Vane End of Vane to Bell Arm Linkage Rod 027671100 2 2 2 2 2 21 BALL JOINT, Bell Arm End of Vane to Bell Arm Link. Rod 027671000 2 2 2 2 2 RPL 469021 / Page 16

Low Leak Dampers Diagram & Assemblies 17 16 23 21 20 19 22 18 6 15 7 Damper Assemblies 1 Bub. No. Description Part Number Unit Size 137D 141D 150D 164D 172D 5 Low Leak Damper Assembly 31 7/8" x 112 3/8" 048545101 1 5 Low Leak Damper Assembly 39 5/8" x 112 3/8" 048545001 1 1 5 Low Leak Damper Assembly 47 5/8" x 112 3/8" 048545701 1 1 1 Note: NO Damper Actuators, Actuator Linkage, sensors, OR controls were supplied with Central Station Air Handler units. If a field supplied item is required, contact Daikin Applied with vendor and vendor part number information to see if a suitable replacement can be obtained. RPL 469021 / Page 17

Low Leak Dampers Components Bub. No. Description Part Number Qty. for Unit Size 137D 141D 150D 164D 172D 6 Damper Blade (Less Gasket) 047793302 4 5 5 6 6 7 Damper Blade Center Support 047792401 1 Damper Blade Center Support 048545401 1 1 Damper Blade Center Support 048546001 1 1 15 Damper Blade Gasket Gasket ordered by the foot as required 029870900 - - - - - 16 Driven Damper Blade End Plug Assy. RH 044961208 1 1 1 1 1 17 Driven Damper Blade End Plug Assy. LH 044961209 1 1 1 1 1 18 Non Driven Damper End Plug RH 041003508 3 4 4 5 5 19 Non Driven Damper End Plug LH 041003509 3 4 4 5 5 20 Nylon Damper Blade Bushing 043730400 6 8 8 10 10 21 Nylon Damper Blade Drive Shaft Bushing 043734000 4 4 4 14 14 22 Nylon Linkage Bar Bushing 046098300 8 10 10 12 12 23 0.50" Locking Collar 049115902 2 2 2 2 2 RPL 469021 / Page 18