3X9.8 MW GAS ENGINE POWER PLANT IRAN PROJECT SAMPLE. Endeco

Similar documents
TurboPHASE: Cost- Effective and Efficient Peaking Power

Medium speed generator sets. Products and applications

1. Combustion Engine Power Plants. Asko Vuorinen Aalto University

Medium speed generator sets Products and applications

AVL Media Conditioning Systems

Siemens Industrial Gas Turbines 斯奥动力集团 SOAR POWER GROU P

Pete Jacobs. Business Development Manager Wartsila North America, Inc. (281)

We power the world with innovative gas turbines

Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters

Diesel Power Generating Plants. Introduction

SGT-2000E gas turbine series

DEUTZ Corporation 914 Gas. Customer / Event DEUTZ Corporation Presentation DATE, 2010

XQ-5200 Solar T60 Gas Turbine-Generator 5,200 ekw Iso Conditions 13.8 kv

NITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai , India.

Trust. Quality. Excellence.

Efficiency Increase of a High Performance Gas Engine for Distributed Power Generation

TG 150 G8V TX 86 (Dwg. No /xx)

See Note. 100% of rated load

See Note. 100% of rated load

See Note. 100% of rated load

Energy Plan. Public Forum Presentation January 25, 2011

Power plant performance under extreme ambient conditions

DEMONSTRATION OF A HYDROGEN FUEL CELL LOCOMOTIVE

Power conversion systems for energy storage. Engineering that stores

Technical Specification

Simplifying the energy transition flexible and easy-to-use converter for innovative grids usa.siemens.com/sinacon-hc

Test Report. Test of Danvest Low Load Diesel for Solar-Diesel Projects. Type: Performance Test. Model: Danvest HSD-648 Serial no.

Bi-Fuel Conversion for High Speed Diesel Engins

North Mole Gibraltar Project Example of CO 2 footprint improvement with Gas & Dual Fuel engines

Product Overview. 1.0 About VRB-ESS. 2.0 System Description. MW-Class VRB-ESS

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Combustion Gas Turbine Fuel Pumps. CIRCOR White Paper

NXPLUS C Single busbar. Maintenance-free for lifetime

See Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.

See Note. 100% of rated load

T5S4P3 Synchronous Condensers Application. Mr. Marco Schenone Mr. Sandro Tuscano Mr. Alessandro Oldrati

Medium Speed Generator Sets Products and Applications

Development of the 3-phase PV Inverter SANUPS P83D

MVDC PLUS Managing the future grid

Engine technology 16 and 20V34SG

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

TM2500 & TM2500+ Mobile Gas Turbine Generator

ALCOHOL LOX STEAM GENERATOR TEST EXPERIENCE

Performance Enhancement of Multi-Cylinder Common Rail Diesel Engine for Automotive Application

SGT-2000E gas turbine series

Power Technology ASEAN Overview

ABB Power Generation Microgrids and renewable energy integration ABB solution and offering overview

Piston Compressors. Volume range: l/min

Chinese Solar Cooling Conference Large Scale Solar AC System Project

SYMPOSIUM ON INDUSTRIAL APPLICATIONS OF GAS TURBINES

METAL ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, INSULATED IN AIR AND SF6 GAS UP TO 36KV

Totally Integrated Power. A reliable all-rounder. Gas-insulated medium-voltage switchgear 8DJH 36.

Energetech LLC 7427 S. Main (P.O. Box 400) Midvale, Utah (801) Ph. (801) Fx.

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Commercialized storage solutions for enhanced grid operation

THE ONLY MEGAWATT-SCALE CONTAINERIZED FLOW BATTERY

Excellence in testing. Comprehensive test bay solutions from a single source. siemens.com/test-stands

Combustion Equipment. Combustion equipment for. Solid fuels Liquid fuels Gaseous fuels

Power Conversion System The Best Technology for your photovoltaic and storage system

Generating sets. and turn-key solutions

Industrial RB211 Gzero Gas Turbines

Sauer Compressors. for Shipping. reliable low maintenance compact

ENVIROAIRE T & TVS HP OIL-FREE TWO-STAGE FIXED & VARIABLE SPEED ROTARY SCREW COMPRESSOR. EnviroAire T/TVS

4,5 MW el. Efficiency on a new level. TCG 2032 TCG 2032B V16. 44,6 % electrical. 43,2 % thermal.

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

VALVE TIMING DIAGRAM FOR SI ENGINE VALVE TIMING DIAGRAM FOR CI ENGINE

Wärtsilä Capital Markets Day

17-IAGT-104 Siemens introduces the SGT-A45 mobile unit: superior performance with trusted technology

Fuel Flexibility and Engine Types Utilisation of sidestreams (LNG, O&G) Moscow

Cooling Systems CC Series TT rail 20/30lpm

SeaFloat SCC-A65. Technical Solution Information. Unrestricted. Vers.

500V / V /

MSB kw

Check out your benefits: Screw compressors S series

Save fuel and maximize power system reliability That s smart control. Hybrid power plant solutions

Jorge Álvarez, PM Solar, Abril 15 th - Santiago. ABB Solar Central lnverters (PMGD)

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Modular contactors and relays

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Aggregate Drying Burners ASTEC AGGREGATE DRYING BURNERS. For Hot Mix Asphalt Facilities

Emission Reduction Technologies towards zero emissions

MARINE. Decrease fuel consumption and emissions with shaft generators and drives

XCEL ENERGY PROJECT UPDATES Michelle Lim

Increase Turbine Output. Gas Turbine Inlet Cooling

Wärtsilä North America

EUROMOT. Recommendation for emission limit values and definition of stationary engines. Angers, 02 October Panagiotis Daskalopoulos, Euromot

PERFORMANCE DATA [1HZ00788] JULY 09, 2014 For Help Desk Phone Numbers Click here

Auramarine fuel supply units PIONEERING FUEL SUPPLY SOLUTIONS FOR POWER INDUSTRY

B kv T&D GAS INSULATED SWITCHGEAR

White paper. MARPOL Annex VI fuel strategies and their influence on combustion in boilers

Cummins Westport Near Zero Engines

MOBILAIR M 135/M 170/M 171. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 10.5 to 17.0 m³/min ( cfm) COMPRESSORS

MOBILAIR M 200. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 14.5 to 21.2 m³/min ( cfm)

See Note. 100% of rated load 2,4,6, (17.73)

J920 FleXtra PowerPack

Integrated PowerStation. Advanced Power Solution for Reactor 2

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

GE Oil & Gas. High-speed solutions. World-class HSR compressors and the worldwide service capabilities to support them

Caterpillar C3600 Diesel Engines Operation Maintenance & Troubleshooting

SULLAIR. oil free. Rotary Screw Air Compressors hp kw

Transcription:

3X9.8 MW GAS ENGINE POWER PLANT IRAN PROJECT SAMPLE Endeco

Project Description The proposed modular power plant is designed for Base Load operation and is intended for power generation by means of 3 gas engine GenSets, for a total actual power output of 28 MWe. The main fuel is natural gas supplied from pipeline. The system is designed for parallel operation with the public supply system and/or for operation in island mode, and can be easily adapted for peak load operation for electrical grid balance. The project has been developed in collaboration with Wartsila. MAIN FEATURES: Location: Site elevation: Primary movers: Northern Iran 1350 asl 3 x 9.8 MW Gas Engine Generating Set Plant total power output (Nominal): 29.4 MWe Plant total power output (Actual): Main fuel: 28 MWe Natural gas from pipeline, delivery pressure 200 PSI PROCESS DIAGRAM:

EQUIPMENT Gas Engine: 3 x 9.8 MW spark ignited lean burn engine Generator: Nominal voltage Nominal power Speed 11000 V 9800 kw 750 rpm Electrical system configuration Engine cooling: Fuel system: Connection to 20 kv national grid Cooling radiators closed loop water system Filtering, metering and pressure regulation skid (one per engine). POWER PLANT SITE PLOT PLAN

TYPICAL SECTION External view of the exhaust gas stack ENGINE HALL PLAN VIEW Internal view of the gas engine hall, showing the gas engines/generators and the engine auxiliary modules, intake air and exhaust gas ducts

Gas Engines Technology Overview GAS ENGINES TECHNOLOGY Engine power plants Reciprocating engines are the most efficient means today of converting liquid or gaseous fuels into energy. They reach an electrical efficiency of 48% in simple cycle and up to 90% in CHP mode, and the single unit have a stable, optimal efficiency starting from 50% partial load. Fuels The main fuel used is natural gas, the cleanest fossil fuel available, but Engines can be easily arranged in dual fuel configuration, using both gas as well as liquid fuels such as LFO and HFO. Modularity & flexibility The entire plant output range can be optimized by means of multi-unit configuration. This allows, for example, to turn down the load of a 5 units plant up to 10% maintaining a best efficiency output. This is particularly suitable for peak demand power plants, where the load can be quickly adjusted according to actual grid power demand Gas engines are fast to start-up, and even in the worst conditions they can reach the full load in a few minutes. Single unit operation can be stopped and restarted even several times per day without affecting plant efficiency and low maintenance requirements during its lifetime. Adaptability to ambient conditions Gas engines are particularly suitable to withstand extreme ambient conditions, with minimal output derating due to high altitude or temperature. A profitable investment The compact size, modularity and simple installation of gas engines power plants, compared to other popular power solutions, allow: - lower delivery time - lower investment costs per MW installed - faster payback time - incremental investments, adding new units as the needs evolve ADVANTAGES OF GAS ENGINES Plant electrical efficiency of up to 50% in simple cycle (54% in combined) Minimal output derating due to high altitude and temperature Quick start capability, full working load is reached in a few minutes Stable, optimal efficiency in a wide range of partial load Modular configuration enhancing flexibility, reliability and optimizing investment costs Fuel flexibility: natural gas, LFO and HFO in dual fuel configuration Low gas pressure requirements, allowing direct connection to pipeline without using gas compressors Minimal utilities consumption and lowest environmental impact among fossil fuels power technologies Environment Modern gas engines allows very low environmental impact. Emissions levels fulfill most of the emission requirements, without using secondary cleaning methods. Moreover, the use of air coolers reduces water consumption almost to zero, allowing plant operation even in remote locations.

PRATO DELLA VALLE 81 35123 PADOVA ITALY endeco@endeco.it CAPITALE SOCIALE 520.000 REG. TRIB. PD 28227 CCIAA PD 205152 P. IVA 01341140281