WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Similar documents
HEATING COOLING SYSTEM DESIGN

Solutions from SPTT-3

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

Application and Engineering Manual

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

I.C.E. DIRECT FIRED MAKE-UP AIR UNITS

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

FILCAB, FILCAR & EZ Flex Sizes 016, 020, 024

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Air Handling Unit Fan Selection Guide

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

BAC / BHC SERIES 6 to 20 Ton Air Handlers

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

High Performance Fan Coils FCHG Genesis Series Horizontal

PA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER

KG7T (E and N Series)

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

FG7T (E and N Series)

Cooling Capacity CFM in. w.c. (125 Pa)

BAC / BHC Product Specifications

PHB SERIES 7-1/2 and 10 TON

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Tonnage Blower Modules Cooling Coil Modules

Product Data. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR) EZ Flext (EXPXX) Sizes 16, 20, 24. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR)

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

KG7T (C and L Series)

Product Data. that this product meets the S 95% AFUE S Two -stage operation

BAC / BHC SERIES 6 to 20 Ton Air Handlers

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

G8MVL. Product Specifications

Safety & Installation Instructions

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

KG7T (C and L Series)

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

WFMR/WFML. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

Dimension and Selection Guide

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

Complete HVAC Capability

Air Purifiers Product Guide

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

FOR USE IN SOLUTION AIR HANDLING UNITS

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

Modular Variable Speed Air Handlers

APPLYING VSO OPTION TO SOLUTION AIR HANDLING UNITS

RCBA- MULTIFLEX INDOOR COILS

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

N9MPD Product Specifications

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

Cooling Capacity CFM in. w.c. (125 Pa)

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

PHR5. Product Specifications

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

RETROFIT TERMINAL UNITS

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

R4H4. Product Specifications

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

FNCCAB & FILBBFNC Sizes 014, 017, 021 & 024

Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace


GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS

Cooling Capacity CFM in. w.c. (125 Pa)

KG7S (A and K Series)

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

SILENCER SELECTION INSTRUCTIONS

Cased/Uncased Coils For Gas And Oil Furnaces

ENGINEERED PRODUCTS. Project: Unit Tag: MS-80-D-3 Page 1 of 5

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5

OVERVIEW Combination Supply/Return Diffuser (SARM)

F8MTL. Product Specifications

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Transcription:

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City _ Prov Postal code Phone ( ) Fax ( ) Designer/Signature: Phone: ( ) Fax ( ) Date: / / By: ( Contractor ) Name Address City _ Prov Postal code Phone ( ) Fax ( ) Designed Equipment: ( Heating ) Designed Equipment: ( Accessories ) Gas furnace Electronic air cleaner Oil furnace Pleated air cleaner Propane furnace Electrostatic air filter Electric furnace Dry media filter ( thickness ) Heat pump Merv filter Water coil & blower Water heating coil Designed Equipment: (Cooling ) Electric heating coil Indoor coil Other Outdoor Unit Ventilation System ( Integrated ) Air handler System type : Other Mixed air temperature F Forms available from: HRAI * 2800 Skymark Avenue * Building 1* Suite 201 Mississauga, Ontario * L4W 5A6 Reproduction in any form by mechanical means is forbidden. Copyright by: The Heating Refrigeration and Air Conditioning Institute of Canada.

PART A - DESIGN LOAD SPECIFICATIONS page 2 A.1 Sub Total Heat Loss Btuh. A.2 Ventilation Heat Loss Btuh. A.3 Total Heat Loss (A.1 + A.2) Btuh. A.4 Sub Total Heat Gain Btuh. A.5 Ventilation Heat Gain Btuh. A.6 Total Heat Gain (A.4 + A.5) Btuh. A.7 Volume of House: (Heated Area) X (Average Ceiling Height) cu ft. A.8 Ventilation Flow Rate: As per Heat Loss/Gain Worksheet cfm. PART B EQUIPMENT SELECTION Heating Equipment: Cooling Equipment: Make Model Make Model (Outdoor Unit) Fuel Type: Gas Oil Electricity Other Make Model (Indoor Unit) B.1 Heating Output (Minimum 100% - of A.3) Btuh. Cooling Medium: DX Chilled Water Other B.2 Approved Temperature Rise/range F. B.5 Cooling Output (80% - 125% of A.6) Btuh. Tons B.3 Equipment External Static Pressure in. W.C. B.6 Manufacturers Flow Rate/Ton (cfm/ton) B.4 Heating Air Flow Rate (blower specs) cfm B.7 Cooling Air Flow Rate. Target Air Flow rate = B.5 X B.6 cfm Actual Air Flow Rate (blower specs) cfm B.8 Coil Pressure Drop, in. W.C. Dry: Wet: Speed setting: Adjustment: Speed Setting: PART C AIR DISTRIBUTION & PRESSURE Adjustment: C.1 Circulation Air Flow Rate ( A.7 x 0.025 ) cfm C.5 Calculated Heating Temperature Rise [ B.1 (B.4 x 1.08) ] F C.2 System Design Air Flow Rate (highest of B.4, B.7, C.1) cfm C.6 Filter Pressure Drop in. W.C. C.3 Cooling Airflow Proportioning Factor Calculate to 4 decimal places (B.7 A.4) cfm/btuh C.7 Coil Pressure Drop (B.8) in. W.C. C.4 Heating Airflow Proportioning Factor Calculate to 4 decimal places C.8 Total of Pressure Drop (C.6 + C.7) in. W.C. C.9 Available Design Pressure (B.3 C.8) cfm/btuh or Selected Design Pressure in. W.C. (C.2 A.1) or (B.4 A.1) Note: When furnace standard filter is replaced, subtract its pressure drop from the replacement filter and record on line C.6

PART D - DETERMINING ROOM AND FLOOR DESIGN FLOW RATES page 3 D.1 Floor D.2 Room D.3 Cooling load (Btuh) D.4 Room cooling flow rate (D.3 x C.3) D.5 Heating load (Btuh) D.6 Room heating flow rate (D.5 x C.4) D.7 Number of outlets per room D.8 Floor supply air flow rates (greatest airflow heating or cooling) PART D - CONTINUED D.1 D.2 D.3 D.4 D.5 D.6 D.7 D.8 PART E - INLET FLOW RATES Floor level (Location) E.1 Floor return air flow rate E.2 Minimum number of openings E.3 Actual number of openings Basement (50% D.8 Max) 1st floor (Sum of D.8 Min) 2nd floor (Sum of D.8 Min) 3rd floor (Sum of D.8 Min) E.4 Actual cfm per opening ( E.1 E.3 ) Note: After location of supply outlets and return inlets are determined, produce preliminary drawing. Total = ( C.2 ) (System cfm)

PART F - SUMMARY OF TOTAL EFFECTIVE LENGTHS FOR RETURN DUCTS page 4 Inlet No Equipment Connection (Group 1) Trunk To Drop Connection (Group 1) Trunk Transitions (Group 2) Trunk Fittings (Group 2) Duct To Joist (Group 3) Turbulence Effect Stud To Joist (Group 4) Grille Opening To Stud (Group 4) Measured Length (ft) Branch Effective Length (ft) PART G - DUCT DESIGN PRESSURE G.1 (Return Branch Longest Effective Length ft). G.2 R/A Plenum Pressure: Available Design Pressure (Line C.9) x Return Air Apportioning Factor (Appendix C (C3)) ( ) x ( ) = _ in. W.C. (Record Line H.8) G.3 S/A Plenum Pressure: Available Design pressure (Line C.9) - R/A Plenum Pressure ( ) - ( ) = in. W.C. (Record Line J.7)

PART H - SIZING OF RETURN GRILLES, BRANCHES AND MAIN TRUNK DUCTS page 5 H.1 Trunk Letter/No H.2 Inlet Location (Room) H.3 Inlet No (R) H.4 Inlet flow rate (cfm) (Line E.4 adjusted) H.5 Minimum required inlet free area (sq. in.) (Appendix C8) H.6 Inlet size (Appendix A) H.7 Inlet Pressure Loss (in. W.C.) H.8 R/A Plenum pressure (in. W.C.) (Line G.2) H.9 Adjusted duct design pressure (H.8 - H.7) H.10 Branch effective length (ft) (Part F) H.11 Loss/100 ft. of effective length [(H.9 x 100) H.10] H.12 Branch duct size (round) (H.4, H.11) (Appendix C4,5) H.13 Branch rectangular equivalent (Appendix C6) H.14 Joist to trunk opening size (2 x area H.13) H.15 Trunk flow rate (cfm) accumulation of H.4 H.16 Lowest loss/100 ft encountered from duct end. H.17 Trunk duct size (round) (H.15, H.16) (Append C4,5) H.18 Trunk rectangular equivalent (Appendix C6) H.19 Installed Trunk size (Transitions) H.20 Trunk velocity (fpm) fpm = [(cfm x 144) area]

PART I - SUMMARY OF TOTAL EFFECTIVE LENGTHS FOR SUPPLY DUCTS page 6 Outlet No Plenum Trunk Trunk Trunk Aspiration Duct Branch Boot Measured Branch Fitting Transition Fittings To Branch Effect Flex Elbows Fitting Length (ft) Effective (Group 5) (Group 6) (Group 6) Take offs Length (ft) (Group 8) (Group 8) Length (ft) (Group 7)

PART J - SIZING OF SUPPLY DIFFUSERS, BRANCHES AND MAIN TRUNK DUCTS page 7 J.1 Trunk Letter/No J.2 Outlet location (Room) J.3 Outlet No (S) J.4 Outlet flow rate (cfm) (Line D.6 D.7) (Heating) J.4b Outlet flow rate (cfm) (Line D.4 D.7) (Cooling) J.5 Outlet size J.6 Outlet pressure loss (in. W.C.) J.7 S/A Plenum pressure (in. W.C.) (Line G.3) J.8 Adjusted duct design pressure (J.7 - J.6) J.9 Branch effective length (ft) (Part I) J.10 Loss/100 ft of effective length [(J.8 x 100) J.9] J.11 Branch duct size (round) (J.4, J.10) (Appendix C4,5) J.12 Branch rectangular equivalent (Appendix C6) J.13 Trunk flow rate (cfm) accumulation of J.4 J.13bTrunk flow rate (cfm) accumulation of J.4b J.14 Lowest loss/100 ft encountered from duct end. J.15 Trunk duct size (round) (J.13, J.14) (Appendix C4,5) J.16 Trunk rectangular equivalent (Appendix C6) J.17 Installed Trunk size (Transitions) J.18 Trunk velocity (fpm) fpm = [(cfm x 144) area]

PART J - CONTINUED page 8 J.1 J.2 J.3 J.4 J.4b J.5 J.6 J.7 J.8 J.9 J.10 J.11 J.12 J.13 J.13b J.14 J.15 J.16 J.17 J.18