Technical Specifications

Similar documents
Technical Specifications

SI unit for AS-Interface EX250-SAS#

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

SI unit for EtherCAT. EX260 Series

EX##-OMN0011-A. SI unit for EtherCAT PRODUCT NAME. EX260 Series MODEL/ Series

EX510 Series Serial System Technical Specifications

SI unit for Ethernet POWERLINK

Digital Flow Switch (Sensor Part) Operation Manual

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

Digital Flow Switch (Remote type monitor unit)

Digital Flow Switch (Integrated display type)

SI unit for DeviceNet TM PRODUCT NAME. SI unit EX250-SDN1 EX250-SDN1-X102

Digital pressure switch for energy-saving control ejector

Digital Pressure Switch

Solid State Auto Switch D-M9#A#

Technical information for LFU20-Z07-3A-X2

Digital Flow Switch (Integrated display type)

Pressure Sensor for General Fluids PSE570/573/574

Analog Output Terminal

Digital Flow Switch PFM7##

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Digital Pressure Switch

Differential Pressure Transmitter

Air Catch Sensor ISA2

Digital Flow Switch (Remote type sensor unit)

Model Number Structure

Instruction Manual LAMI CORPORATION INC.

EVS RP6020. Instruction Manual

RP Instruction Manual

Lumitester PD-20 Control Kit

Analog Input Terminal

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Vacuum pump system type

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

SG-B1 SERIES / SG-A1 SERIES

Solid State Auto Switch

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Trimmer Auto Switch D-M9K/D-F7K/D-Y7K D-RNK/D-RPK

Trimmer Auto Switch D-F7K/D-Y7K D-RNK/D-RPK

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units


Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

F3S-TGR-KHL1/-KHL3/-KHL3R

19mm Thickness. Phone: Fax: Web:

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

I. Safety precautions

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Pneumatic Drive Type Drill Bit Breakage Detection Sensor. DFM3 Series. The World's First!! Pneumatic-Drive Type. Catalog / Instruction Manual US.PAT.

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Remote Control Engine Starter System Owner s Manual

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Low Torque Metal Seal Type Rotary Joint. MQR Series

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.

Technical Information Solid State Relays. Glossary. Solid State Relays

Gateway Type Serial Transmission System

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Low Differential Pressure Sensor ±1% F.S.

Read and understand this manual for safely usage.

Series 10-ZSE40A(F)/10-ISE40A

Operating Instructions

Two Hand Control Valve

POWER REGULATOR LD -40PSU

OPERATING INSTRUCTION

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

Pressure Sensor/PS-A (ADP5)

MODEL 3567A. Digital MΩ Tester. Instruction Manual

ECONOMISER SERIES E2T USER MANUAL

Technical Documentation

EPS/ELA-Series User Manual EPS/ELA 250W

HS6B Series Subminiature Interlock Switch

Doc.No.LV50***-OMQ0002-E. Product Name. Electromagnetic Digital Flow Switch. Model/ Series/ Product Number LFE#### SMC Corporation

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

OPERATING INSTRUCTION

2-Color Display High-Precision Digital Pressure Switch

0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67.

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Chapter. Installation and. In this Chapter...

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

Pressure Relief 3 Port Valve With Locking Holes

Digital display Pressure range ON/OFF output Linear output Model

High-speed detection even a little liquid leak

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

DATA SHEET FUSIBLE ALLOY THERMAL SENSITIVE PELLET TYPE, 2 AMPERES RATED CURRENT

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

Series ISA. Air Catch Sensor. For Detection of Work Presence

3 Phase Smart Controller

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Digital Gap Checker. ISA3 series

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

LPL (LG Philips) LCD 2k7

Transcription:

No.:EX##-OMG0007 Technical Specifications Product name : SI unit Model : EX250-SAS7 EX250-SAS9

Contents 1. Safety 2. Specifications 2-1 General specification 2-2 Communication specification 2-3 Electrical specification 2-4 Applicable solenoid valves... P2... P6... P6... P7... P7 3. Wiring and setting 3-1 The topology of an AS-i network 3-2 Wiring 3-3 Address setting 3-4 HOLD / CLEAR setting 3-5 Over Current Protection setting SW 3-5-1 Over Current Protection setting SW-ON(OCP-ON) 3-5-2 Over Current Protection setting SW-OFF(OCP-OFF) 3-6 Installation and Maintenance... P8... P8... P9... P9... P9... P9... P9... P10 4. Relation between output data and solenoid valve 4-1 Standard wiring 4-2 Semi-standard wiring(mixed wiring) 5. Data bit 5-1 SI unit I/O data bit 5-2 Status register 6. LED indicator and physical dimensions 6-1 LED indication 6-2 Physical dimensions... P12... P12... P13... P13... P13... P14-1- EX##-OMG0007

1.Safety This manual contain essential information for the protection of users and others from possible injury and damage to property and to ensure correct handling. Please check that you fully understand the definition of the following messages (signs) before going on to read the text, and always follow the instructions. Also read carefully the instruction manual of relevant equipment or apparatus before use. Indications IMPORTANT MESSAGES Read this manual and follow its instructions. Signal words such as WARNING,CAUTION and NOTE, will be followed by important safety information that must be carefully reviewed. Indicates a potentially hazardous situation which could result in death or serious injury if you do not follow instructions. Indicates a potentially hazardous situation which if not avoided, may result in minor injury or moderate injury. NOTE Gives you helpful information. Operator This operation manual has been written for those who have knowledge of machinery and apparatus that use pneumatic equipment and have full knowledge of assembly, operation and maintenance of such equipment. Please read this operation manual carefully and understand it before assembling, operating or providing maintenance to the SI Unit. Usage Restrictions This product is designed for use in general equipment for factory automation. Never use this product with equipment or apparatus that directly concerns human lives* 1, or which malfunction or failure can cause a huge loss. *1: Equipment or apparatus that directly matters human lives means the following: Medical equipment such as life support systems or equipment used in operating rooms Compulsory equipment required by law such as the Fire Prevention Law, Construction Law and etc. Equipment or apparatus that conforms with those mentioned above. Contact our sales department when plans are made for the product to be used for the system* 2 including equipment that concerns itself with the safety of persons or that seriously affects the public. This usage needs special consideration* 3. *2: The system including equipment that concerns itself with the safety of persons or that seriously affects the public means the following: Nuclear reactor control systems in nuclear power plants, safety protection systems or other systems important for safety in nuclear power facilities Driving control systems of mass transportation systems, and flight control systems Equipment or apparatus that comes into contact with foods or beverages *3: Special consideration means discussing usage with our engineers to establish a safe system designed as fool-proof, fail-safe, redundant and etc. Special consideration of safety or maintainability should be taken to prevent hazard or loss caused by a failure or malfunction that is likely to occur in certain probability due to environmental stress (deterioration). The special consideration means to fully review the equipment or apparatus in design stage and to establish a backup system in advance such as a redundant system or fail-safe system. -2- EX##-OMG0007

Do not disassemble, modify (including change of printed circuit board) or repair. An injury or failure can result. Do not operate the product beyond specification range. Operation at a range that exceeds the specifications can cause a fire, malfunction, or damage to SI Unit. Verify the specifications before use. Do not use the product in an atmosphere containing combustible, explosive or corrosive gas. It can cause a fire, explosion or corrosion. This SI Unit is not designed to be explosion-proof. These instructions must be followed when using the product in an interlocking circuit: Provide double interlocking by another system such as mechanical protection Check the product regularly to ensure proper operation Otherwise malfunction can cause an accident. These instructions must be followed while in maintenance: Turn off the power supply Stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance Release all energy stored in equipment or devices (hydraulic pressure, mechanical springs, electric capacitors or gravity force), verify the energy is reset to zero, and then perform maintenance work. Otherwise it can cause injury. Perform proper functional checks after maintenance. Stop operation when an abnormality is observed such that the SI unit does not work properly. Safety is not be assured due to unexpected malfunction. -3- EX##-OMG0007

NOTE Follow the instructions given below when selecting and handling your SI Unit: The instructions on selection (installation, wiring, environment of use, adjustment, operation and maintenance) described below must also be followed. Product specifications Operate SI Unit with the specified voltage. Operation with a voltage beyond specifications can cause malfunction or damage of the unit. Reserve a space for maintenance Remember to leave space for maintenance when designing layout of the unit. Do not remove labels. Otherwise error while in maintenance or misreading of an operation manual can cause damage or malfunction. It may also result in nonconformity to safety standards. Instructions on handling Installation Do not drop, hit or apply excessive shock to the unit. Otherwise it can result in damage to the unit causing failure or malfunction. Follow the specified tightening torque. Excessive tightening torque can break screws. Refer to 3-6 Installation and Maintenance for installation. Wiring (including plugging in/out of connector) Do not bend or apply tensile force to cables, or apply force by placing heavy load on them. Wiring with bending stress or tensile stress can cause breakage of the cables. Connect wires and cables correctly. Miswiring can break the SI Unit depending on the miswired circuit. Do not connect wires while the power is on. Otherwise it can break the SI Unit or I/O devices causing damage or malfunction. Do not lay wires or cables with power cable or high-voltage cable in the same wiring route. Otherwise the wires to the SI Unit can be contaminated with noise or induced surge voltage from power lines or high-voltage lines causing malfunction. Lay the wires to the SI Unit and each I/O device to a wire duct or in a protective tube other than those for power lines or high- voltage lines. Verify the insulation of wiring. Poor insulation (interference with other circuit, poor insulation between terminals and etc.) can introduce excess voltage or current to the SI Unit or each I/O device causing damage. Separate power lines for solenoid valves from power line for Input and control unit. Otherwise wires can be contaminated with noise or induced surge voltage causing malfunction. Take proper measurements against noise such as noise filter when the SI Unit is incorporated in equipment or devices. Otherwise contamination with noise can cause malfunction. Environment Select the proper type of protection according to the environment of operation. IP67 protection is achieved when the following conditions are met. (1)To connect units properly with communication line connector and power cable with M12 connector at the both end, and (2)To install Input unit and input block, and SI Unit and manifold valves properly. Use cover or etc. when install in an environment where water always splashes on these units. -4- EX##-OMG0007

NOTE Take sufficient shielding measures when install at a following place. Insufficient measures can cause malfunction or failure. Verify the effect of the measures after installation of the unit in equipment or devices: (1)A place where noise due to static electricity is generated (2)A place where electric field strength is high (3)A place where there is radioactive irradiation (4)A place near power line (5)A place where water splashes on the product. Do not use the product near by a place where electric surges are generated. Internal circuit elements of the SI Unit can deteriorate or break when equipment generating a large surge (electromagnetic lifter, high frequency induction furnace, motor, etc.) is located near the SI Unit. Provide surge preventives, and avoid interference. Use a SI Unit equipped with surge absorber when a surge-generating load such as a relay or solenoid valve is driven directly. Direct drive of a load generating surge voltage can damage SI Unit. Prevent foreign matter such as remnant of wires from entering this product. Take proper measures for the remnant not to enter the SI Unit in order to prevent failure or malfunction. Do not expose the SI Unit to vibration and impact. Otherwise it can cause failure or malfunction. Keep the specified ambient temperature range. Otherwise it can cause malfunction. Do not use SI Unit in a place where temperature suddenly changes even if it stays within the specified range. Do not expose the SI Unit to heat radiation from a heat source located nearby. It can cause malfunction. Adjustment and Operation Use precision screwdriver with small flat blade when setting DIP and rotary switches. Maintenance Before performing maintenance, make sure to turn of the power supply, stop supplied air, release the residual air in the piping into the atmosphere, and verify that the pneumatic system is open to the air. Otherwise an unexpected operation of a system component can occur. Perform maintenance and check regularly Otherwise an unexpected malfunction of the system can occur due to a malfunction of the unit. Refer to 3-6 Installation and Maintenance the maintenance and checking methods. Perform a proper functional check. Stop operation when an abnormality is observed such that the device does not work properly. Otherwise an unexpected malfunction of the system component can occur. Do not use solvents such as benzene, thinner or other to clean the SI Unit. It can damage the surface of the body and erase the indication on the body. Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains again with a dry cloth. -5- EX##-OMG0007

2.Spesifications 2-1. General Specification Item Specification Operating ambient temp. +5 to +45 C Storage ambient humidity 35 to 85%RH (No condensation) Storage ambient temp. -20 to +60 C Vibration proof 50m/s 2 (Complies with JIS C 0911) Impact proof 100m/s 2 (Complies with JIS C 0912) Noise immunity ±1000Vp-p. Pulse duration 1µs. On first transition 1ns Withstand Voltage 500VAC for 1min. Between body and external terminals. Insulation resistance 500VDC 10M ohm or more. Between body and external terminals. Operating environment No corrosive gas Weight 250g or less Enclosure IP67 2-2 Communication specification Item Specification EX250-SAS7 EX250-SAS9 Applicable system AS-Interface (AS-i) AS-i Version Version 2.11 Address mode Standard Address Mode Number of occupied slave 2 1 Max.number of connected Slaves 31 Address Assignment range 1 to 31 IO Code (HEX) 7, 7 7 ID Code (HEX) F, F F ID Code 1(HEX) Set within 0 to F optionally ID Code 2(HEX) E, E E D0 IN 0,4/OUT 0,4 IN 0/OUT 0 D1 IN 1,5/OUT 1,5 IN 1/OUT 1 D2 IN 2,6/OUT 2,6 IN 2/OUT 2 D3 IN 3,7/OUT 3,7 IN 3/OUT 3-6- EX##-OMG0007

2-3 Electrical specification Item Specification EX250-SAS7 EX250-SAS9 Power supply For voltage communication Supplied from AS-Interface communication 26.5 to 31.6VDC*1 Current For consumption *2 communication 100mA MAX. 65mA MAX. Input point 8 4 Input and output specification Input style TTL Connection Input block Input block : EX250-IE1 to 3 *3 Supply voltage for Input block 24VDC±20% Output point 8 4 Output style Connection output block Supply voltage for output block P-MOS FET open drain style Solenoid valve with lamp surge protection circuit for 24VDC and 1.5W or less surge voltage 24VDC±10% Residual voltage 0.3V or less Current consumption *4 240mA MAX. 120mA MAX. *1 : The power supply for the communication must use the special power supply made for AS-i. Refer to each maker s manual etc. for details. *2 : Current consumption inside SI unit. *3 : Refer to the Input Block Technical Specifications for details. *4 : Total current value which can be supplied from connected all block to connected all equipment. Refer to technical specifications for details. Example) EX250-SAS9 Valve: VQC1100NY-5 (Low watt type 0.5W) 4pieces 0.5[W] 24[V] 4[pieces]=84[mA] (Turning on four outputs simultaneously) EX250-SAS9 can supply Max.120mA current for input and output block. So, EX250-SAS9 can supply the current to the sensor connected with the input block as follows. 120[mA] 84[mA]=36[mA] We recommend the use of low watt type valves and the number output at the same time to be reduced. And, we recommend sensors with a little consumption current to be used. (Two wire type sensor etc.) 2-4 Applicable solenoid valves Representative series Applicable series VQC series VQC1000 Series, VQC2000 Series, VQC4000 Series SV series SV1000 Series, SV2000 Series, SV4000 Series Refer to each solenoid valve catalogue etc. for details. You can select valves which are not low watt type. However, we recommend unit (EX250-SAS3, 5) to which the power supply line of the input and the output is separated because there is a limit in the current which can be supplied. -7- EX##-OMG0007

3.Wiring and setting 3-1 The topology of an AS-i network The topology of an AS-i network can be connected a tree, a line and point-to-point. The total length of the cable is 100m. It is possible to extend the length of a total cable up to 300m by using a repeater. Tree AS-i master Line AS-i master Point to point AS-i master : AS-i slave Terminating registors are not required. 3-2 Wiring Communication connector : M12 male 4pins Communication connector 2 1 3 4 No. Description Function 1 AS-i + Positive AS-Interface line 2 RESERVE RESERVE 3 AS-i Negative AS-Interface line 4 RESERVE RESERVE Connection example M12 Cable Recommendation Conductor cross-section 1.5mm 2 EX250-SAS7 AS-i Standard cable (YELLOW CABLE) Connector for T-branch ASI FK M12 Hirschmann etc. (IEC 603526) Neither M12 cable, As-i standard cable, nor connector for T-branch are supplied form SMC. Contact with each maker about the detail of the catalog etc. Wire the cable with AS-Interface line so that a total voltage drop becomes 3V or less. -8- EX##-OMG0007

3-3 Address setting AS-i cable line should be disconnected to unit while setting address. Open the cover and set address by AS-Interface address programming device and DC power jack cable etc. (PEPPERL + FUCHS: VAZ-PK- V1-Cinch, SIEMENS: 3RK1901-3HA00 etc.) Address assignment range is 1 to 31. The address can be set regardless of connecting order, but it is not possible to set address overlap. The address at shipment from the factory is 0. Set different address for ADDR1 and ADDR2 as EX250-SAS7 occupy 2 slaves respectively. *If address is set by AS-i cable line via master unit, in EX250-SAS7, it is possible to set the slaves one by one cutting off from AS-i cable line with DC power jack for address setting inserted into the side which is not subject to address setting at the moment (ADDR1 or ADDR2). And lightening of LED during address setting is not abnormal. EX250-SAS7 ADDR1: Address setting for IN0 to 3/OUT0 to 3 ADDR2: Address setting for IN4 to 7/OUT4 to 7 3-4 HOLD/CLEAR setting Set whether maintaining SI unit output condition or turn off of it when communication error is generated. This switch at shipment from the Factory is CLEAR. 3-5 Over Current Protection setting SW 3-5-1 Over Current Protection setting SW-ON (OCP-ON) When the over current load is connected with the each block, and the unit supply current value (specification value) is exceeded, unit LED becomes the IN-ERR lighting and COM-ERR blinking and the power supply to the each block is stopped. 3-5-2 Over Current Protection setting SW-OFF (OCP-OFF) When the over current load is connected with the each block, and the unit supply current value (specification value) is exceeded, unit LED becomes the IN-ERR lighting and COM-ERR blinking. The power supply to the each block does not change. This switch at shipment from the Factory is OCP-ON. Use by setting OCP-OFF becomes a specification not applied to the AS-i spec. Therefore, please use the SI unit with OCP-ON usually. Turn off the power supply and remove the cause immediately when over current load is connected with the input block, and the peripheral fault error occurs by over current detection. Using with the peripheral fault error occurs unit damage. Over Current Protection setting SW (Over Current Protection:OCP) OCP ON HOLD/CLEAR SW for setting CLEAR OCP OFF HOLD Address jack for setting (DC Power Jack) AS-i - AS-i + ADDR1 jack for setting ADDR2 jack for setting Cover opened -9- EX##-OMG0007

3-6 Installation and Maintenance How to set Not having mounting hole, it can t be set to the device independently. Use SI unit by setting manifold. And if Input Block is unnecessary, connect End Plate directly to SI unit. Setting Exsample Manifold of VQC1000 series The number of solenoids =n(pieces) The number of Input Blocks =m(pieces) M4 6 Thickness:13.2(mm) SI PWR AUX ADDRESS SETTING ADDR1 IN COM -ERR -ERR ADDR2 CLEAR SW HOLD EX250 66(mm) L2 21 m 89.9(mm) L1 10.5 n 45(mm) For example, the table below shows the size when manifold of VQC1000 series connected. Please refer to an individual catalog for the size when other manifolds are connected. n,m L 0 1 2 3 4 5 6 7 8 L1 45 55.5 66 76.5 87 97.5 108 118.5 129 L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 (mm) Wiring (for power supply, communication and input) and piping are done on only one side. On the side, make a space -10- EX##-OMG0007

Maintenance Addition of Input Block Remove screws from End Plate. Mount attached tie rod. Connect additional Input Block. Connect End Plate and tighten removed screws by specified tightening torque. (0.6N m) Exchange of SI unit Remove screws from End Plate and release connection of each unit. Replace old SI unit with new one. (Tie rod does not need to be removed.) Connect End Plate and tighten removed screws by specified tightening torque. (0.6N m) For maintenance (1) Be sure to turn-off all power supplies. (2) Be sure that there is no foreign object in any of units. (3) Be sure that gasket is lined properly. (4) Be sure that tightening torque is according to specification. If these items are not kept, it may lead to the breakage of substrate or intrusion of liquid or dust into the units. -11- EX##-OMG0007

4.Relation between Output data and solenoid valve 4-1 Standard wiring The outputs of the SI unit are assigned from the D side solenoid valve in the order 0,1,2,... etc. Refer to each solenoid valve s catalogue for details. Standard Address Mode (EX250-SAS7, EX250-IE3, Manifold standard wiring, Double solenoid wiring) ADDR2 Input area ADDR1 Input area ADDR1 Output area ADDR2 Output area 3:IN7 3:IN3 OUT1 OUT3 OUT5 OUT7 B side 2:IN6 1:IN5 2:IN2 1:IN1 EX250-SAS7 0:IN4 0:IN0 OUT0 OUT2 OUT4 OUT6 A side D U Standard manifold 4-2 Semi-standard wiring (Mixed wiring) As semi-standard wiring, mixed wiring inside manifold is available. The wiring type is specified by description of single or double solenoid valve mounted on manifold. In order to specify the mixed wiring, completion of Manifold type solenoid valve Specifications Sheet is required. -12- EX##-OMG0007

5.Data bit 5-1 SI unit I/O data bit Address Data bit EX250 SAS7 EX250 SAS9 ADDR1 ADDR2 D0 IN 0 / OUT 0 IN 0 / OUT 0 D1 IN 1 / OUT 1 IN 1 / OUT 1 D2 IN 2 / OUT 2 IN 2 / OUT 2 D3 IN 3 / OUT 3 IN 3 / OUT 3 D0 IN 4 / OUT 4 D1 IN 5 / OUT 5 D2 IN 6 / OUT 6 D3 IN 7 / OUT 7 5-2 Status register It is possible to check the peripheral fault error (blowing the input block fuse or detecting over current of input power supply) by monitoring the status bit S1 which complies with the AS-i Version 2.11 ST S3 S2 S1 S0 PB EB Start bit Status bit Parity bit End bit 0:Normal 1:Error Blowing the input block fuse or detecting over current of input power supply It is possible to confirm the peripheral fault error only by status register on the ADDR1 side for EX250-SAS7 which occupy 2slaves. Turn off the power supply and remove the cause immediately when over current load is connected with the input block, and the peripheral fault error occurs by over current detection. Using with the peripheral fault error occurs unit damage. 6.LED indiator and physucal dimensions 6-1 LED indicator SI PWR AUX ADDRESS SETTING ADDR1 IN -ERR CLEAR COM SW -ERR HOLD ADDR2 EX250 Name PWR LED Condition Green Light Contents In time of power supply for AS-Interface line is turned on. AUX (Lights off at normal condition) IN-ERR Red Light COM- ERR Red Light In time of input power is detected over current. (Lights off at normal condition) In time of communication error. (Lights off at normal condition) Red Blink In time of peripheral equipment error. (Over current of input power, blowing the fuse etc.) -13- EX##-OMG0007

6-2 Physical dimensions 42.5 59.8 75.1 64.4 63-14- EX##-OMG0007