High-Precision Digital Pressure Switch ZSE40 /ISE40 Series Set pressure range 0.00 to.000 Pa For positive pressure How to Order For Positive Pressure ISE40 0 22 SDPC For Vacuum/Compound Pressure ZSE40 0 22 SDPC Series compatible with secondary batteries aterial restriction Nil F Set pressure range 0.0 to 0.3 kpa For vacuum pressure 00.0 to 00.0 kpa For compound pressure Option Nil None Panel mount (ZS-22-A) Piping specifications E 0: R /8 (with 5 female threads) R /8 5 x 0.8 female threads Panel mount + Front protective cover (ZS-24-C) F *Specifications and dimensions for the series are the same as standard products. Input/Output specifications 22 NPN open collector 2 outputs 62* PNP open collector 2 outputs *Optional Lead wire length 0.5 m SDPC *With 2 connector *When optional parts only are required, order with the part numbers inside ( ). Unit specifications Nil With unit switching function SI units only Note) Note) Fixed units For vacuum/compound pressure : kpa For positive pressure : Pa 58
High-Precision Digital Pressure Switch for General Fluids ZSE50F/ISE50 Series How to Order Directional Control Valves For positive pressure For compound pressure 02 Series compatible with secondary batteries aterial restriction Panel ount Part No. Option Panel mount Panel mount + Front protection cover ISE50 02 ZSE50 F 02 Piping specifications R /4 (5 with female screw), Piping in backward direction Part no. ZS-24-E ZS-24-F Input/ output specifications 22 NPN open collector 2 output 62* PNP open collector 2 output *Optional *Specifications and dimensions for the series are the same as standard products. Qty. 22 22 SDPC SDPC Lead wire length SDPC 0.5 m *With 2 connector Option Nil None Panel mount E F Panel mount + Front protection cover Unit specification Nil With unit switching function Fixed SI unit Note) Note) Fixed units: For compound pressure : KPa For positive pressure : Pa Air Filters/Pressure Control Equipment Air Preparation Equipment Air Grippers Actuators Detection Switches Vacuum Equipment Flow Control Related Products 59 Auto Switches
2-Color Display Digital Flow Switch Integrated display PF7 Series How to Order Integrated display Series compatible with secondary batteries aterial restriction 7 PF7 0 C6 B Type Integrated display Rated flow range (Flow rate range) 0 0.2 to 0 (5) l/min 50 to 50 (25) l/min 2 to 00 (50) l/min * ( ): Fluid: CO2 Option Nil None Bracket (For without flow adjustment valve) ZS-33--X22 R ounting screw (accessory) Symbol C6 C8 Description ø6 One-touch fitting ø8 (5/6") One-touch fitting Port size Flow rate range 0 50 T Panel mount adapter (For without flow adjustment valve) ZS-33-J Panel mount adapter A Panel mount adapter B B E Output specification 2 PNP outputs PNP output + Analog ( to 5 V) Panel Unit specification Fixed SI unit Note) Note) Fixed unit: Real-time flow rate: l/min Accumulated flow: l ounting bracket *Specifications and dimensions for the series are the same as standard products. 60
For Water Digital Flow Switch Integrated Display Type Series compatible with secondary batteries aterial restriction Remote Type Sensor Unit Series compatible with secondary batteries aterial restriction PF2W Series Symbol 03 04 06 Flow rate range 04 0.5 to 4 l/min 20 2 to 6 l/min 40 5 to 40 l/min How to Order PF2W7 20 03 67 Port size 3/8 /2 3/4 Flow rate (l/min) 4 6 40 Flow rate range 04 0.5 to 4 l/min 20 2 to 6 l/min 40 5 to 40 l/min Thread type Nil Rc N NPT F G Port size Applicable model PF2W704, PF2W720 PF2W720, PF2W740 PF2W740 PF2W5 20 03 Thread type Nil Rc N NPT F G Unit specification Nil Output specification 67 PNP open collector 2 outputs With unit switching function Fixed SI unit Note) Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Lead wire Nil 2 3 m lead wire with connector N Without lead wire Directional Control Valves Air Filters/Pressure Control Equipment Air Preparation Equipment Air Grippers Actuators Flow Control Related Products Symbol 03 04 06 Port size 3/8 /2 3/4 Flow rate (l/min) 4 6 40 Port size Applicable model PF2W504, PF2W520 PF2W520, PF2W540 PF2W540 Vacuum Equipment Symbol 2 Nil N Lead wire 2 3 m lead wire with connector Without lead wire Output specification Specification Applicable monitor unit (monitor) model Output for monitor unit + Analog output ( to 5 V) Output for monitor unit + Analog output (4 to 20 ma) Series PF2W300 Note) The monitor is not compatible with series products. *Specifications and dimensions for the series are the same as standard products. 6 Detection Switches Auto Switches
Solid State Auto Switch D-9BW(V)SDPC-0 Series Compatible with Secondary Batteries/aterial restriction Auto Switch Specifications Refer to SC website for the details of the products conforming to the international standards. model Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Response time Electrical entry Lead wire Impact resistance Connector standards Enclosure Insulation resistance Withstand voltage Ambient temperature Standard PLC: Programmable Logic Controller D-9BW(V)SDPC-0 24 VDC relay, PLC 0 VDC to 28 VDC 2.5 ma to 40 ma 4 V or less 0.8 ma or less ms or less Operating position Red light is ON. Proper operating position Green light is ON. Grommet Oilproof flexible heavy-duty vinyl cord, ø2.7 x 3.2, ellipse Switch,,000 m/s 2 Connector, 300 m/s 2 JIS C 4524, JIS C 4525 IEC 947-5-2, NECA 0402 In compliance with IP 67 when coupled 50 Ω or more (500 VDC ega) between lead wire and case,000 VAC for min. (between lead wire and case) -0 C to 60 C CE marking Dimensions D-9BWSDPC-0 2.5 x 4l Special order number Connector size 2 (mm) ost sensitive position D-9BWVSDPC-0 2.5 x 4l Connector size 2 Special order number ost sensitive position 62
Solid State Auto Switch D-9BW(V)L-0 Series Compatible with Secondary Batteries/aterial restriction Auto Switch Specifications model Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Response time Electrical entry Lead wire Impact resistance Insulation resistance Withstand voltage Ambient temperature Standard Dimensions D-9BWL-0 Refer to SC website for the details of the products conforming to the international standards. PLC: Programmable Logic Controller D-9BW(V)SDPC-0 24VDC relay, PLC 0 VDC to 28 VDC 2.5 ma to 40 ma 4 V or less 0.8 ma or less ms or less Operating position Red light is ON. Proper operating position Green light is ON. Grommet Oilproof flexible heavy-duty vinyl cord, ø2.7 x 3.2, ellipse, 0.5 mm 2, double core,000 m/s 2 50 Ω or more (500 VDC ega) between lead wire and case,000 VAC for min. (between lead wire and case) -0 C to 60 C CE marking 2.5 x 4l ost sensitive position Special order number (mm) Directional Control Valves Air Filters/Pressure Control Equipment Air Preparation Equipment Air Grippers Actuators Flow Control Related Products D-9BWVL-0 2.5 x 4l Vacuum Equipment Detection Switches ost sensitive position Special order number 63 Auto Switches
Solid State Auto Switch D-Y7BW(V)L-0 Series Compatible with Secondary Batteries/aterial restriction Auto Switch Specifications Refer to SC website for the details of the products conforming to the international standards. model Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Response time Electrical entry Lead wire Impact resistance Insulation resistance Withstand voltage Ambient temperature Standard PLC: Programmable Logic Controller D-Y7BW(V)L-0 24 VDC relay, PLC 0 VDC to 28 VDC 2.5 ma to 40 ma 4 V or less 0.8 ma or less ms or less Operating position Red light is ON. Proper operating position Green light is ON. Grommet Oilproof flexible heavy-duty vinyl cord, ø3.4, 0.5 mm 2, double core,000 m/s 2 50 Ω or more (500 VDC ega) between lead wire and case,000 VAC for min. (between lead wire and case) -0 C to 60 C CE marking Using flexible cable as standard spec. The optimum operating position can be determined by the color of the light. (Red Green Red) Dimensions D-Y7BWL-0 2.5 x 4l (mm) ost sensitive position D-Y7BWVL-0 2.5 x 4l ost sensitive position 64
Reed Auto Switch Direct ounting Style D-AL-0/D-Z80L-0 Series Compatible with Secondary Batteries / aterial restriction Auto Switch Specifications D-AL-0 (Without indicator light) 2.5 x 4L 2.8 4 4.5 2 0 ost sensitive position 24.5 PLC: Programmable Logic Controller model Applicable load D-AL-0 IC circuit, Relay, PLC AC AC AC Load voltage 24 V DC or less 48 V DC or less 00 V DC or less aximum load current Contact protection circuit Internal resistance Standard 50 ma 40 ma None Ω or less (Including lead wire length of 3 m) CE marking 20 ma Lead wiresoilproof heavy-duty vinyl cord, ø2.7, 0.8 mm 2 x 2 cores (Brown, Blue), 3 m Dimensions D-AL-0 Auto Switch Specifications D-Z80L-0 (Without indicator light) model D-Z80L-0 Applicable load Relay, PLC, IC circuit AC Load voltage 24 V DC or less 48 V AC 00 V AC DC DC aximum load current 50 ma 40 ma 20 ma Contact protection circuit None Internal resistance Ω or less (Including 3 m lead wire) Standard CE marking Lead wiresoilproof heavy-duty vinyl cord, ø2.7, 0.8 mm 2 x 2 cores (Brown, Blue), 3 m Dimensions D-Z80L-0 Refer to SC website for the details of the products conforming to the international standards. ø2.7 (mm) Refer to SC website for the details of the products conforming to the international standards. PLC: Programmable Logic Controller (mm) Directional Control Valves Air Filters/Pressure Control Equipment Air Preparation Equipment Air Grippers Actuators Flow Control Related Products Vacuum Equipment Detection Switches ost sensitive position 65 Auto Switches
Auto Switches Auto Switch ounting Bracket Part No. Applicable cylinder series: /CDLQ, RSDQ Applicable auto switches : D-9BW(V)L-0, D-9BW(V)SDPC-0, D-AL-0 Applicable bore size (mm) Cylinder series 20 25 32 40 50 mounting mounting CDLQ brackets are not required. brackets are not required. qbq-2 qbq-2 wbq2-02 wbq2-02 ebba2 ebba2 RSDQ qbq2-02 wbba2 qbq-2 wbq2-02 ebba2 Port side C A B mounting surface and auto switch mounting bracket used mounting rail only Port side A, B, C side qbq2-02 wbba2 (See the table below for screws and nuts.) Two types of auto switch bracket are used as a set. w q mounting brackets are not required. qbq-2 (Only resin spacers are used.) wbq2-02 ebba2 (See the table below for screws and nuts.) Three types of auto switch bracket are used as a set. e w q Note ) When a compact auto switch is mounted on 3 sides (A, B, and C above) other than the port side of each cylinder series with ø32 to ø50, auto switch mounting brackets above are required. Order them separately from cylinders. Order example RSDQB32-20D-9BWL BQ2 2 (Only resin spacers are used.) BQ2-02 2 BBA2 2 Note 2) When shipping cylinders, auto switch mounting brackets and auto switches are shipped together. Details of stainless steel mounting screw set Description Part No. Part BBA2 mounting screw mounting nut (square) mounting nut (convex) Size 3 x 0.5 x 6L 3 x 0.5 x 8L 3 x 0.5 x 0L 3 x 0.5 3 x 0.5 Quantity Applicable bore size ø20, ø25 ø32 to ø50 ø20, ø25 ø32 to ø50 Note 3) A spacer (black resin) for BQ-2 is not included. Note 4) Use auto switch mounting screws and nuts for lengths applicable to individual bore sizes. 66
Auto Switches Auto Switch ounting Bracket Part No. Applicable cylinder series: CDJ2, /CDG, /GG, /CDNG Applicable auto switches : D-9BWL-0, D-9BWSDPC-0, D-AL-0 Cylinder series CDJ2 CDG GG CDNG Applicable bore size (mm) 0 6 20 25 32 40 50 qbj2-00 wbj3- qbj2-00 wbj3- qba2-020 wbj3- qba2-025 wbj3- qba2-032 wbj3- qba2-040 wbj3- Note) Since mounting screws attached to BJ2- and BA2- are made of steel, use stainless steel mounting screw set BBA4. Details of stainless steel mounting screw set Description Part No. Part Size Quantity BBA4 Applicable cylinder series: /CDA2, CDNA Applicable auto switches : D-9BW(V)L-0, D-9BW(V)SDPC-0, D-AL-0 Cylinder series CDA2 CDNA mounting screw Applicable bore size (mm) 40 50 63 80 00 BA7-040 3 x 0.5 x 4L BA7-040 Part No. of applicable auto switch mounting bracket BJ2-00/BJ2-06 BA2-020/BA2-025/BA2-032 BA2-040/BA2-050 c d Switch holder (Resin) Switch bracket (Stainless steel) BA7-063 BA7-080 BA7-080 b mounting screw (Steel) a mounting band qba2-050 wbj3- e Switch spacer (Stainless steel) Set screw (Unused) qbj2- and BA2- are the set of a and b above. wbj3- is the set of c, d, and e above. Directional Control Valves Air Filters/Pressure Control Equipment Air Preparation Equipment Air Grippers Actuators Vacuum Equipment Note) D-AL-0 cannot be mounted on ø50. Detection Switches Flow Control Related Products 67 Auto Switches
Auto Switches Auto Switch ounting Bracket Part No. Applicable air gripper series: /9HL2 Applicable cylinder series : /YB, /YH, CY3R, /GP, RS()H Applicable auto switches : D-9BW(V)L-0, D-9BW(V)SDPC-0, D-AL-0 Air gripper series Cylinder series Applicable bore size (mm) 2 5 6 20 25 32 40 50 63 HL2 YB Note ) YH CY3R GP RSHNote 2) mounting brackets are not required. mounting brackets are not required. mounting brackets are not required. RSHNote 2) Note ) /YB series D-9BW(V)L-0 or D-9BW(V)SDPC-0 cannot be mounted on ø50. D-AL-0 cannot be mounted. Note 2) RS()H series D-AL-0 cannot be mounted. For /YB and /YH series For CY3R, /GP and RS()H series A 68