Inline Ultrasonic Flowmeter

Similar documents
Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

M-100 Adjustable flow switch with right-angle flow

LFC Integrated Flow Control Module. Description Malema Sensors

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

MFC Integrated Flow Control Module For Slurries and Chemicals. Key Features. applications.

NT ELECTRONIC FLOWMETER, MODEL 4400

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

LFC Integrated Flow Control Module. Description.

NT Flowmeter, Model 4401

Adjustable Flow Switches

InVue Electronic Flowmeter, NT4400

Integrated Flow Controller, Model NT6500

Time Delta S Fixed Transit-Time Flow Meter System

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

Positive displacement flowmeter for continuous flow measurement

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

MODEL 106F TEFLON LIQUID FLOW SENSOR

Flow Monitors Excess Flow Valves Flow Meters. ChemTec.com

Figure 1: WPR2 Dimensions and Hardware

Paddle-wheel flow controller for On/Off control

F-2700 SERIES INSERTION VORTEX FLOW METER

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Ultra Compact UHP Liquid Flow Controllers

F-1500 SERIES INSERTION TURBINE FLOW METER

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

Paddle-wheel flow controller with optical principle for On/Off control

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Technical information for LFU20-Z07-3A-X2

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Operating Manual Model- P282 Digiflow Controller

Instruction manual. Smart Thermal Mass Flow Meter. TYPE : 3000S Series. ientek Co., Ltd.

ISTEC MAGNETIC METERS

Principle of Operation

F-2600 SERIES INLINE VORTEX FLOW METER

MODEL U801 PTFE Flo-Controller for UHP Liquid Applications. uhp

5001TCP SPEED CONTROLLER

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Paddle-wheel flow controller for On/Off control

F-2700 SERIES INSERTION VORTEX FLOW METER

M Series. Feature rich flow meter and switch with in-line. flow

Product Guide: Series III Pump Control Board Set (RoHS)

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

5001TCP SPEED CONTROLLER

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Hydro-Flow Model 2300 Installation and Operation Guide B

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Vortex Eggs Delta Flowmeter

Differential Pressure Transmitter

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Magnetic Inductive Flowmeter EP / UMF2 (B)

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Insertion magnetic inductive flowmeter

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Positive displacement batch controller

I N S T R U C T I O N M A N U A L

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

Hydro-Flow Model 2200 Installation and Operation Guide B

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

25% reduction in volume * PB1013A/Air-operated type without foot

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

UTM10 Series Ultrasonic Transit-time Flowmeters

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

SIGNET 7002 Vortex Flow Sensor ENGLISH

M-200 Series. High flow, Adjustable flow switch with right-angle flow

Appendix. Clearance. Skewed profiles. Application Schematics

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

A Member of the. Integrated Metering Technologies

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Electromagnetic Flow Monitor magphant

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

M-50/55 Series. Fixed setting flow switch with in-line flow

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Installation and Operating Manual

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

INSERTION flow sensor for continuous flow measurement

PFA Eddysonic flowmeter

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

Data Sheet. I/P and E/P converters. RS stock numbers ,

NT PROPORTIONAL CONTROL VALVE, MODEL 6300

VORTEX IN-LINE FLOW METERS

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Description. Measurement Principle. Key Features. Applications. Malema SUMOFLO. 1 Barb Single-Use Sensor for g/min

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Model DFX Doppler ultrasonic flow meter

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

Multivariable Vortex Flow Meter

Transcription:

M-1500 Series Installation and Operating Manual The M-1500 series is an inline primary flow sensor and externally mounted controller unit. The flow sensor is a straight through flow tube that uses Transit Time differential method with a microprocessor based measurement design for precise measurement of flow rate. The controller electronics receives the raw flow rate signal from the sensor and provides flow rate information in terms of analog and pulse output signals. Operation This flowmeter uses a non-intrusive method to determine the flow rate of the liquid. Two piezoelectric transducers are mounted on the outer diameter of the flow tube and are excited producing a vibration. Alternately each transducer s ultrasonic disturbance transmits through the tubing wall and is propagated along with the liquid flow and back against the flow. The propagation wave velocity varies with flow rate and is proportional to flow rate. The flow rate can be determined by measuring the variation of these propagation wave velocities. (Covered by U.S. Patents) Features Ultrasonic flow sensing technology - robust proven technology Capable of measuring flows from 1-4000 ml/min Measuring accuracy of ±2% of READING (5% of reading below 20% of flow range) Compact design - ideal for use in semiconductor process tools Sensors/Transducers sit outside tube - hence completely non-invasive No pressure drop - since there is no obstruction in flow path Minimal bubble entrapment compared to other designs due to INLINE flow path Ideal for precise measurements in low flow applications No moving parts: hence no particle generation Fast response time (0.1 sec) ideal for CMP process measurements where flow fluctuations are high due to use of peristaltic pumps Transducers resistant to harsh chemical environments (NEMA 4X compliance) Applications CVD, CMP, and lithography tools Medical Devices Wet process systems Corrosive chemical distribution Laser equipment Cooling systems Certifications Applied for UL and CE certificates. malema flow sensors 1

M-1500 Series Dimensions SENSOR DIMENSIS (Available in 1/16 & 1/4 Also) DIMENSIS FOR SINGLE CTROLLER Figure 1 Figure 2 2 Malema Flow Sensors 1060 South Rogers Circle Boca Raton, Florida 33487 1-800-637-6418 561-995-0595 Fax (561) 995-0622 http://www.malema.com Copyright 2001

Specifications Performance Specifications Flow Range: 1-4000 ml/min Accuracy: + 2% of reading (for 20-100% of flow range) + 5% of reading for 0-20% of flow range. Repeatability: + 0.5% Functional Specifications Analog Output: Isolated 4-20 ma (Maximum load resistance of 500 ohm) current Certifications output. Pulse Output: Isolated Open Collector (15V, 15 ma) Frequency of 1000 hz at flow rate of 100% Low flow cut off: 2% - Enabled by Dip Switch Electrical Input: 24 VDC + 10% 300mA Optional Display: 4 digit 7 segment display, indicates instantaneous flow rate in ml/min Ambient Temperature range: 32-115 F (0-46 deg C) Fluid Temperature range: 50-140 F (10-60 deg C) Maximum Operating Pressure: 70 psig for PFA Material Specifications Sensor Housing : PP or PTFE or PVDF Non-wetted parts: Peek, PP, PVDF, VitonA, FEP Wetted parts: PFA (high purity) Physical Specifications Sensor unit: Equivalent to NEMA 4X(IP65) Controller: Equivalent to NEMA 2 (IP20) Sensor Unit Dimensions : 1.3 (W) X 2.0 (H) X 4.4 (D) Single Controller Dimensions :4.0 (W) X 1.65 (H) X 4.3 (D) Cable Material: PTFE Jacketed Custom shielded cable. Cable Length: 3 Meters max. Fluid Viscosity: 8 cp max. 1 Time Constant: Field Adjustable(0.1s to 5s) 1 Higher viscosities would require special tube sizing and custom calibration. malema flow sensors 3

M-1500 Series Installation Sensor Select location for mounting sensor that has Ambient temperature (0 to 60ºC (32 to 140 F) away from direct sunlight. Free from electromagnetic interference. Keep away from heavy electrical devices such as motors, pumps, power-relays and solenoid valves. No air or gas bubbles in the flow, since they cause hindrances to propagation of ultrasonic waves. No water splashes or corrosive gases. Has ease of access for maintenance. Figure 3 Mounting Hardware: Use four M4 x X (X = 0.35 + thickness of the mounting plate) Philip pan head screw (not provided) to secure the M-1500 sensor onto the panel. It is advisable to mount the flow sensor with the flow going vertically upward. This ensures that no bubbles get trapped within the sensor. This also prevents any sedimentation from the fluid from accumulating inside the sensor section. It is advisable to mount the sensor at a position in the flow circuit that has maximum fluid pressure (upstream of flow control valves). The sensor should always be filled with liquid (even when there is no flow). In case the flow sensor cannot be mounted vertically, it is OK to mount it in ANY convenient orientation. The flow sensor will function satisfactorily when mounted in ANY orientation. However, the person installing the unit must ensure that no bubbles get trapped in side the sensor tube and the fluid does not have solid particles that would sediment inside the sensor tube section. 4 Malema Flow Sensors 1060 South Rogers Circle Boca Raton, Florida 33487 1-800-637-6418 561-995-0595 Fax (561) 995-0622 http://www.malema.com Copyright 2001

Controller The controller module can be panel mounted as shown in figure4 below CAUTI Figure 4 All possible electric noise sources in the vicinity of flowmeter, such as motors, pumps, power relays or solenoid valves, should be fitted with suitable surge suppressor. malema flow sensors 5

M-1500 Series Wiring The sensor unit is supplied with a 6 ft cable (standard). The connector at the end of the sensor cable needs to be connected to the controller box at the location marked SENSOR. NOTE: The sensor should be connected to the controller BEFORE supplying power to the unit. Failure to do this will result in malfunction of the unit. In case this sequence is not followed please power the unit down disconnect and reconnect the sensor connector and then power the unit up. The figure below shows the connector located on the back of the controller. The description of each terminal is listed on the figure 5. Figure 5 Please use electrical conductors of size AWG 24-20 stripped and tinned about 5 mm. These can be inserted into the respective terminal hole. The terminal block has self-locking mechanism that will bind on the stripped electrical wire. To release the conductor, press the respective tab next to the terminal hole. Caution: Check voltage supply to be 24 VDC BEFORE connecting to the unit. Excessive/incorrect voltage can cause permanent damage to the unit. 6 Malema Flow Sensors 1060 South Rogers Circle Boca Raton, Florida 33487 1-800-637-6418 561-995-0595 Fax (561) 995-0622 http://www.malema.com Copyright 2001

Pre - Start-up Check Confirm the following before turning power on Wiring corresponds with figure 5 Make sure the flow sensor and the controller serial numbers match. Verify cable connection between sensor and controller for the ultrasonic flowmeter is secure. Ensure that the connector is locked on with a positive click. Make sure the sensor and the controller are connected before powering the unit. Power supply voltage at terminal is 24 VDC + 10% Flow direction corresponds with arrow mark on the flow sensor. Flow detector is completely filled with liquid. Confirm no leakage, no bubbles and no deposits are observed. If there are bubbles, eliminate them by flushing. Zero Set It is always advisable to Zero Set during initial installation before starting ANY flow measurements. Please follow the procedure listed below to ensure that the ZERO set is done in the proper sequence. Caution: Incorrectly ZERO set on the flow meter would give erroneous readings. Flow liquid continuously to ensure ALL air bubbles are purged out (large and small bubbles). Shut off flow ensure liquid inside the sensor tubing is STATIARY. Verify the reading on the controller unit as ZERO. If yes, the ultrasonic flowmeter is ready to use and does not have to be ZERO SET If not ensure that the reading is STEADY. This indicates that the flowmeter needs to be ZERO set. Press ZERO button on the controller while maintaining STATIARY liquid inside the tube. You should see the reading on the controller go to zero in a few seconds While the flowmeter is being ZERO SET, the NORM led on the controller will blink. This is normal and indicates that the unit is doing internal computing. Do not begin flow liquid unless the NORM led glows steady. When the reading reaches zero (with stationary fluid), then the ultrasonic flowmeter is ready for use. Calibration For Different Fluids If there is any change in the fluid medium i.e any fluid other than the fluid on which the flowmeter has been factory calibrated the flowmeter needs to be CLEAR set so as to show flow readings. Please follow the procedure listed below to ensure that the CLEAR set is done in the proper sequence Flow liquid continuously to ensure ALL air bubbles are purged out (large and small bubbles). Shut off flow ensure liquid inside the sensor tubing is STATIARY. Press CLEAR button on the controller while maintaining STATIARY liquid inside the tube. You should see the reading on the controller display. This reading will necessarily not be zero although the fluid is stationary. To ensure that the flowmeter reads steady ZERO under stationary fluid conditions please follow the steps mentioned under the section Zero Set. malema flow sensors 7

M-1500 Series Trouble Shooting Guide S. No. 1 Phenomenon Display does anything not show Possible Cause and Solution No power supply. Please make sure that the tinned wires are inserted adequately deep enough into their respective terminal hole. 2 The NORM led is not lit up Same as above 3 ERR led is continuously on Call technical support 1-800-637-6418 4 Display shows "E" 5 Display show "Or" 6 Display shows "----" E is displayed if the sensor tube is empty or if bubbles are entrapped inside the M-1500 sensor tube. Refer to section "Zero Set" to get valid reading on the flowmeter controller "Or" is displayed if the flow inside the flow tube is greater than the specified full scale of that particular unit. Adjust the flow rate, below full scale, and the flow meter should show a valid reading "----" is displayed if the flowmeter sensor is mounted in the wrong direction and flowed. Make sure the flow direction is in accordance with the arrow on the flowmeter sensor. 7 Display reading is unstable during flow conditions Display reading can become unstable if there are micro bubbles present inside the flowmeter sensor tube. Flush the sensor tube to remove the micro bubbles and the reading should now be stable 8 Malema Flow Sensors 1060 South Rogers Circle Boca Raton, Florida 33487 1-800-637-6418 561-995-0595 Fax (561) 995-0622 http://www.malema.com Copyright 2001

Operation and Features The flow sensor, once set-up, will monitor and report liquid flows. The section below lists the various functions that may be set by DIP Switches located on the front panel of the flow meter CTROLLER DIP Switch Setting Function Switch Position 1 Factory Preset "" 2 Factory Preset "" 3 Low Flow Cutoff (% F.S ) 4 Flow Direction 5 Full Scale Flow 6 Output Time Constant 7 Output Time Constant Do Not Switch Do Not Switch on Low cutoff off - Low cutoff - Reverse - Forward - Low Flow Range - High Flow Range See Table Below See Table Below DIP SWITCH 6 8 Output Time Constant Time Constant Settings DIP SWITCH 7 DIP SWITCH 8 Output Time Constant 0.5 Sec 1.0 Sec See Table Below STATUS 2.0 Sec FACTORY SET 2.5 Sec 3.0 Sec Maintenance The M-1500 flow meter has a no moving parts and if set up correctly, should not require any maintenance. Since it has no moving parts there is no wear and tear in M-1500 ultrasonic flowmeter. However, we recommend the following to ensure smooth and reliable operation Check for leakage around pipe connections or liquid penetration into the flow sensor. Check for mechanical stress to flow sensor, which could be caused by wraping of connecting pipes or loose connections cause by mechanical vibration of pipes. malema flow sensors 9