Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Similar documents
Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

The BVX-100 Fume Extraction System

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

EQUIPMENT. Loctite Bench Top Air Filtration System Plenum Style Part Number Air Filtration System With Arm Part Number

MODEL FA1 Mini Air Filtration System. Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

FA1 Series Air Filtration System. Operations Manual

Fume Extraction Planning Guide

Why Fume Extraction? Lead-Free Solders Are The Worst

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

GARDEN HOSE UTILITY PUMP

Operating Manual PFB-2500

ARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B

MODEL GS1-100 Air Filtration System. Operations Manual

ARM-EVAC 500 Central Filter Unit

AUTOMATIC SUBMERSIBLE UTILITY PUMP

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

Operation Manual for ARM-EVAC 150 Fume Extraction System

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

MODEL FA5 Air Filtration System. Operations Manual

DESKTOP CONTAINMENT SYSTEM

ARM-EVAC 105. Central Filter Unit

Operating Instructions. International English. CCS Dust Extractor

EXT HEPA/CARBON FUME HOOD

Owner s Manual Drill and Light Weight Portable Utility Pumps

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Triple Output Power Supply

Environmental Series Air Curtains

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

SUPER PUMP OUT SYSTEM

OWNERS MANUAL JANUARY 2007 ISO

Power Inverter 400 MW Owner s Manual

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

SUBMERSIBLE SUMP PUMPS

USER MANUAL TMT-PH200 IR PREHEATER.

SPH-400 i Series General Manual

Integrated Heating System

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

MITYFLEX PERISTALTIC PUMPS

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

DC to AC Power Inverters

DC to AC Power Inverters

SUBMERSIBLE SUMP PUMPS

WELDING FUME EXHAUSTERS & ARMS

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Miracle State Of The Art Air Filtration System!

SPH General Manual 400 Series

MIL-24/2600Q MIL-24/3200DQ

WARNINGS, CAUTIONS AND NOTES

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

D-Series Blowers and Exhausters

Triple Output High Resolution Power Supply. User Manual

User s Manual for Tennessee Chill Box System P/N CB8000

Model 1900, 1901, 1902 Switching DC Power Supply

OMEGA CORDLESS SERIES VACUUM INSTRUCTION MANUAL

OCTA FLUORESCENT 7 SOCKET FIXTURE

Model G14SD Vapor Management System

Installer s Manual. PCO/UV N-Duct Model

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

User s Manual D-Series Blowers and Exhausters

Model 1672, 1673 Triple Output Power Supply

OmniAire 2200 Operations and Maintenance Manual

EXT DUCTLESS FUME HOOD

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

44,400mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Switching DC Power Supply

300 Volt Electrophoresis Power Supply

ELECTRICALLY INSULATED 14mm PROBE

M-3025CB-AV Fuel Pump

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

INDUSTRIAL PUMP 8000 SERIES

WF-5110R True Sine Wave Inverter

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

OWNERS MANUAL JANUARY 2007 ISO

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

Matson Jump Starter Operator s Manual

OmniAire 2200C Operations and Maintenance Manual

PPD-130 PERISTALTIC PUMP DISPENSER

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

INDUSTRIAL PUMP 8000 SERIES

415DS AUTO DISCHARGE WET SOLUTION VAC PARTS MANUAL REV A

Model 1693, 1694 Switching DC Power Supply

ADI-125/750 ADI-125/1500 ADI-125/2500

HYDRAULIC POWER PACK

Quick-Start Operating Guide Document No Universal Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

Transcription:

Test Equipment Depot - 800.7.84-99 Washington Street Melrose, MA 076 TestEquipmentDepot.com BTX-08 Fume Extraction System

System User Guide For Your Safety... Items Supplied... Description... Installation... Operation and Maintenance... Maintenance... Troubleshooting... 4 Technical Data... Part Numbers... Warranty... For Your Safety For safe and successful operation of this equipment, please read this user guide completely. If the instructions stated herein are not observed or followed, the manufacturer cannot assume responsibility for any harm or damage to the operator or equipment. Please retain this manual for future reference. Always disconnect the power supply before servicing the equipment. Do not operate this equipment without filter inserts as contaminants in the extracted air will damage the blower. Use only filters recommended or supplied by OK International. The BTX-08 is designed for the removal of fumes and gases only. Consult your company s Safety Department when using this equipment for filtering of flammable gases. This equipment is not explosion safe and can only be used for the extraction of vapors that have a concentration level well below the lower explosive limit. This equipment is equipped with automatic reset overload protection that may restart the equipment automatically after an overload shutdown. While under warranty, the unit may be repaired only by an authorized OK International Service Representative.

Items Supplied Filter Unit with filters installed mm hose adapter air inlet cover installed on second air inlet port Power Cord Operating Manual Description 4 () ON/OFF switch () power connection () mm hose adapter (4) air bypass valve () latch (front and back) Installation Place filter unit () at a location which minimizes length of ducting Screw supplied hose adapter into open air inlet port () Install ducting () as per duct installation instructions Install iron adapter kits (4) Connect filter unit to power supply () 4 Operation and Maintenance Turn unit ON. Adjust air by-pass valve on second air inlet cover according to number of solder irons connected. This will eliminate a fluttering effect of the pump at low airflow rates. Note: the fluttering does not cause any damage to the system. Maintenance The airflow of the filter unit decreases during operation due to several reasons: Clogging of vacuum tubes and hoses attached to solder iron Saturation of pre and main-filter inside filter unit Cleaning of tip extraction tubes: Clean stainless steel vacuum tubes () periodically and frequently. Cleaning brushes are supplied with the iron adapter kits. Inspect vacuum hoses () visually and clean if needed.

Replacement of filters: If, after cleaning of accessories, the fumes are not extracted efficiently, replace filter(s) inside filter unit. Initially replace the pre-filter only. If this step does not sufficiently improve the airflow, then replace the main filter (HEPA/Carbon).. Turn unit off.. Disconnect the power cord.. Unlatch the filter cover (). 4. Remove filter cover.. Replace the filters. (Pre-filter/main filter). Make sure to place main filter inside the alignment pins () so that interlock switch () is depressed. 6. Replace filter cover and ensure proper fit on bottom housing. Hook both latches into filter cover and press down carefully. Caution! Do not use force. If latches do not close, check proper seating of filter cover on bottom housing. 7. Reconnect power cord and turn system on. 8. If unit does not operate, refer to troubleshooting section. Notice: Always use new replacement filters! For disposal of used filters follow local environmental and safety requirements. Troubleshooting Problem Possibly Cause Solution No air flow No Power Interlock switch open Little air flow Clogged tubes / hoses Air leak Check On/Off Switch Check power outlet Check power cord Check filter Check safety interlock switch Clean extraction tube at solder iron Clean vacuum hoses Check duct connections for leaks Housing not closed correctly 4

Technical Data Max. number of stations 8 Flow rate per station > 8 lit/min Noise Level: < dba Dimensions (WxDxH) 08 x 4 x 88 mm (0" x 0" x.") Weight: 9 kg (0 lbs) Voltage 00-40 VAC Frequency 0 60 Hz Power 8 Watt Certification UL / CSA / CE Part Numbers BTX-08 Filter Unit tip extraction for 8 stations, 00-40V / 0-60Hz Replacement Filters FP-BVX00 Pre-filter (Pack of ) FM-BVX00 Main filter, HEPA 99.9% / Carbon Duct Connection Kits BTX-CK- Hose connection kit -4 stations.m (8 ) long BTX-CK4-0 Hose connection kit 4-8 stations m (6 ) long BTX-CK4-7 Hose connection kit -4 stations 7.m () long For Iron Adapter Kits contact your OK International Sales Representative. Warranty OK International warrants the BTX-08 system against any defects in materials or workmanship for one () year from the date of purchase by the original owner. This warranty excludes normal maintenance and shall not apply to any opened, misused, abused, altered or damaged items. If the product should become defective within the warranty period, OK International will repair or replace it free of charge at its sole option. The repaired or replacement item(s) will be shipped, freight prepaid, to the original purchaser. The warranty period will start from the date of purchase. If the date of purchase cannot be substantiated the date of manufacture will be used as the start of the warranty period. For repair or return of the equipment anytime, a Return Material Authorization Number (RMA #) from OK International is required.