740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

Similar documents
740G Double Disc Check Valve

720A Wafer & 821A Globe Style

720G Wafer and 821G Globe Style Silent Check Valves

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

14 and Larger Wafer and Lug Style Dual Disc Check Valve. Operation, Maintenance and Installation Manual

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

24 and Larger Butterfly Valves

Rectangular Butterfly Valve

3" 20" Bonded Seat Butterfly Valves

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Triton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2

INSTRUCTION MANUAL RECTANGULAR BUTTERFLY VALVE 3-SIDED SEAT

TITAN FLOW CONTROL, INC.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

COMPACT CHECK VALVES Engineering Creative Solutions for Fluid Systems Since 1901

CUSTOM COMBINATION AIR VALVE

BF Series Wafer/Lug Butterfly Valves

Henry Pratt MDT Actuators. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #MDTOM Revision Date: 1/12/11

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

ISO-DE Double Eccentric Butterfly Valves

Metal Seated Ball Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: MSBVOM Revision Date: 07/06/09

Val-Matic 1/2-3 Well Service Air Valve With Dual Port Throttling Device

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

DEMCO Resilient Seated Butterfly Valve

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

DeZURIK 2 20" BOS BUTTERFLY VALVES

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Swing-Flex Check Valve

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

DEMCO Resilient-Seated Butterfly Valve

Swing-Flex Check Valve

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

DeZURIK DR 125 ROTARY DIAPHRAGM ACTUATOR

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Val-Matic 3-Way Tapered Plug Valve

DEMCO DEMCO RESILIENT SEATED BUTTERFLY VALVE. Installation, Operation and Maintenance Manual D I S T R I B U T E D V A L V E S DEM-RSBV-IOM

AWWA C504. Double Eccentric AWWA C504

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

MUELLER GAS. No-Blo Valve. Changers. Reliable Connections. General Information 2-3. Plugging Unit Assembly 4-5. Removing Old Valve 5-6

Val-Matic 4-20 Air/Vacuum Valve

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Sentinel 250 Fire Hydrant

AMERICAN FLOW CONTROL 3-16 SERIES 2100 RESILIENT SEATED CHECK VALVE

Ballcentric Plug Valve

Val-Matic 3"-24" Butterfly Valve With LSA Actuator and External Stops

INSTALLATION, OPERATION AND MAINTENANCE FOR SERIES 500 K-FLO BUTTERFLY VALVES

PO Box 411 Berwick PA VALV

SERIES 300 PLUNGER VALVES

Model 585 Swing Check Valve

AWWA Swing Check Valves

CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

AVK SAUDI VALVES MANUFACTURING COMPANY

6SC SERIES MODELS 910F, 910FLW, 920F IRON SWING CHECK VALVE INSTALLATION OPERATION MAINTENANCE GUIDE

Wafer Silent Check Valves

FIRE HYDRANTS. Wet Barrel Fire Hydrants

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

Installation, Operation, and Maintenance Manual

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

SWING CHECK VALVES SERIES 52-SC SERIES 600

½"-3" Air/Vacuum Valve Models 100S to 103S

TITAN FLOW CONTROL, INC.

Butterfly valves Figure 56 Installation & Maintenance Instructions

SECTION MISCELLANEOUS VALVES

ISO RESILIENT WEDGE GATE VALVE. Engineering Creative Solutions for Fluid Systems Since 1901

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Val-Matic 30" and Larger Butterfly Valve With LSA Actuator and External Stops

DeZURIK M-SERIES MANUAL ACTUATOR

HP250II AND HP250 BUTTERFLY VALVES Engineering Creative Solutions for Fluid Systems Since 1901

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

Installation, Operation, and Maintenance Manual

Fisher RSS Lined Globe Valve

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4

Val-Matic 30" and Larger Butterfly Valve With LSA Actuator and External Stops

DeZURIK SPRING RETURN CYLINDER OPERATOR FOR G-SERIES ACTUATORS USED ON PEF 100% PORT ECCENTRIC VALVES

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

Wastewater Air Release Valve Models 48A, 49A

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

Crispin Valves Operating Guide. Crispin

Baumann Series Flexsleev Control Valve Instructions

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Fisher RSS Lined Globe Valve

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Fisherr V150S Slurry Vee-Ball Control Valve NPS 3 through 12

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Series 820 AWWA Butterfly Valves

Transcription:

Operation / Maintenance Manual 740G Double Disc Check table of contents PAGE General Information 2 Installation/Operation 3 Troubleshooting & Disassembly/Reassembly 4 Parts Information 5 Valve! WARNING: 1. Read all applicable directions and instructions prior to any maintenance, troubleshooting or installation. 2. Personnel involved in the installation or maintenance of valves should be constantly alert to potential emission of pipeline material and take appropriate safety precautions. Always wear suitable protection when dealing with hazardous pipeline materials. 3. Order parts from your local Pratt sales representative or directly from Henry Pratt Company. When ordering parts, please include the serial number located on the valve tag. NOTE: Warning and CAUTION messages (flagged with an exclamation symbol) indicate procedures that must be followed exactly to avoid equipment damage, physical injury, or death. Henry Pratt Company Customer Service 401 South Highland Avenue Aurora, IL 60506 877.436.7977 www.henrypratt.com moreinfo@henrypratt.com

General Information Overview built with stainless trim to give years of trouble-free operation. The double disc check valve can be installed in either horizontal or vertical pipelines that carry clean water or air. This valve is not intended to carry fluids containing solids such as raw sewage or wastewater, nor is it suited for fluids that contain hazardous gases. designed to provide flow in the direction of the arrow marked on the outside nameplate, and instantaneously close upon sensing flow reversal. The nameplate will also indicate valve size, model number, working pressure and materials of construction. Valve Construction The standard double disc check valve body is made from ductile iron. The balance of the internal wetted components are made from type 304 stainless steel. The disc and spring are the only moving parts and require no lubrication or maintenance. The body is a compact wafer type that fits between two pipe flanges. The EPDM seat is bonded to the body and if damaged is not field repairable. Receiving and Storage When valves arrive on site they should be inspected for any shipping damage. Valves should be off loaded from their carrier without being dumped or dropped. When lifting the valve use lifting straps around the body and never lift a valve with straps or chains through the body. Valves should remain in their original shipping container until ready to install into the pipeline. This will prevent any weather related damage to occur and void the warranty. For extended periods of storage the container should remain closed so to not expose the valves seat materials to direct sunlight or ozone. Maintenance-Free lubrication and maintenance free. Once the double disc check valve is installed correctly it will provide the end user many years of trouble free service. 2

Installation / Operation installation installed in the pipeline between two flanges. The flow arrow that is stamped on the nameplate must point in the direction of fluid flow when the pump is running or when the system is in operation. The valve can be installed either horizontally or vertically, with the flow up. For ease of future reference install the valve with the nameplate in the visible orientation. The valve will be installed between two flanges in accordance with ANSI B16.1, Cl. 125, ANSI B16.5 Cl. 150 or AWWA C207, Cl. D or E. When mating the double disc check valve with isolation valves, the downstream isolation valve must be at least one pipe diameter away from the check valve to avoid hitting the discs. The disc edge will extend past the flange face, so it may interfere with the operation of the adjacent valve.! CAUTION: When installing the double disc check valve in horizontal piping systems be sure to install the valve in an orientation that puts the disc hinge in the vertical position. Lower valve into position between mating flanges using slings or chains wrapped around valve body. Never support the valve from within the valve body or valve trim. On larger valves a tapped hole on the top of the valve allows for the use of a lifting eye. Maintenance No Maintenance or lubrication is required. Spare Parts Stocking of spare parts is not recommended. Description of operation designed to prevent flow reversal in applications where this situation can occur. In pumping applications the pump will start the flow of water in the direction noted in chart below. double disc check valve operation flow Disc Hinge Shaft Stop Shaft The flow of water will push against the twin discs and force them back away from the body seat. The water will then flow through the valve between the two discs and body seat, as long as the water pressure keeps the valve open. When the pump stops and water ceases to flow the spring behind the discs will push the discs closed against the body and seal off the flow of water in the opposite direction. The disc closure occurs before the flow of water can reverse thus silencing the operation of the check valve. Typical check valve operation will cause valve slam or water hammer which is due to some degree of flow reversal. The only moving parts in the double disc check valve are the twin discs and spring. The discs and spring are guided in the body with a hinge pin and a full open disc stop pin. The pins are captured within the valve body and a dampening material is used to eliminate vibration. The resilient body seat provides a drop tight seal for any applicable flow media. Body 3

Troubleshooting / Assembly troubleshooting PROBLEM Valve experiences noisy vibration or emits a chatter sound Valve Leakage Valve does not allow flow to occur Valve Slams solution Flow velocity needs to be at least 4 feet per second or better. A partially open valve will wear prematurely. Verify that there are at least 3 pipe diameters of straight pipe upstream of valve. In horizontal piping applications verify disc pin is in vertical position. Debris caught in valve. Remove valve and inspect seating surfaces. Verify flow arrow is in proper orientation. Verify debris is not in line. Remove valve and inspect spring. Spring may have broken. Disc bushing is getting clogged with debris disc is getting stuck open. DisAssembly/reassembly Disassembly! CAUTION: All work performed on any check valve should be made when the valve is fully removed from the pipeline and executed by a trained mechanic using the correct tools. 1. Lay valve flat on bench with flow arrow facing up. Remove square head threaded hinge pin and stop pin retainers and rubber vibration material. 2. Remove pins by driving out from opposite end using a pin punch, while holding down the springs. Use a board and clamp to retain the spring.! warning: The valve spring can rapidly uncoil and cause bodily injury. Secure spring with boards and clamps during maintenance. 3. Lift discs from body. Inspect pins and seats for wear. The shaft diameter is about 1 /32 smaller in diameter than the hole in the disc lugs. Some minor dents and discoloration are normal. Wear in the resilient seat will cause leakage and require valve replacement or refurbishment. 4. Inspect spring for wear or cracks. 5. Remove bearings and inspect for wear. Reassembly NOTE: Prior to assembly all parts should be cleaned and body gasket faces should be wire brushed to remove any residual gasket material to ensure an effective sealing surface. Never use old or used gaskets during installation. 1. Lay body on flat surface with arrow facing upwards. Place the two discs with the machined seating surface down on the body seating surface. Align the disc lugs with the body pin holes. 2. Place washers on top of discs and partially install disc pin. 3. Install one end of spring, hooking spring arm behind the disc lug. Torque spring one half turn and hook other arm to the opposite disc lug. Insert shaft further to hold spring in place and install remaining washers on bottoms of discs. Complete insertion of disc shaft. 4. Install stop shaft. 5. Install pipe plugs, using suitable thread compound to insure seal and to prevent galling. 4

Parts List Parts Information ID Description Material flow 11 10 12 9 8 7 6 5 3 4 2 1 1 Plug ASTM 1035 2 Seal EPDM 3 Shaft 304 Stainless Steel 4 Body Ductile Iron ASTM A536 5 Disc 304 Stainless Steel 6 Screw Aluminum 7 Spring 316 Stainless Steel 8 Washer 1 304 Stainless Steel 9 Washer 2 304 Stainless Steel 10 Name Plate 304 Stainless Steel 11 Seat EPDM 12* Lifting Ring ASTM 1035 *Only for 8" and larger valves TO ORDER: Contact our Parts Department. Henry Pratt Company 401 South Highland Avenue Aurora, IL 60506-5563 Attn: Parts Manager (630) 844-4000 When ordering parts, please include the serial number located on the valve tag and description of part requested. 5

TM Reliable Connections Henry Pratt Company 1.630.844.4000 www.henrypratt.com moreinfo@henrypratt.com International 1.423.490.9555 www.mueller-international.com international@muellercompany.com Copyright 2017 Henry Pratt Company, LLC. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of Henry Pratt Company, LLC, its affiliates or other third parties. Products marked with a section symbol ( ) are subject to patents or patent applications. For details, visit www.mwppat.com. These products are intended for use in potable water or wastewater applications. Please contact your Henry Pratt Company Sales or Customer Service Representative concerning any other application(s). Form 13808 Rev 09/18