Positive displacement batch controller

Similar documents
Positive displacement flowmeter

Positive displacement flowmeter for continuous flow measurement

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller for On/Off control

INSERTION flow sensor for continuous flow measurement

Inductive conductivity meter

Insertion magnetic inductive flowmeter

Inductive conductivity meter

INSERTION flowmeter with paddle wheel, ELEMENT design

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Digital ph transmitter

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Digital ph transmitter

Electrical position feedback for actuator sizes Ø mm

Type Quickstart. English Deutsch Français

Inline Paddle Wheel Flow Switch

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Type SE35. Quickstart. English. Flowmeter Flow Transmitter

INSERTION Adaptor for analysis

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

2/2 or 3/2 way direct acting rocker solenoid valve

Types 8025 / Operating Instructions. Bedienungsanleitung Manuel d utilisation. Flowmeter Durchflussmessgerät Débitmètre

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

MAGNETIC INDUCTIVE FLOW TRANSMITTER

Direct-acting 3/2 way plunger valve

2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN

Simple float switch TCL001/8181

2/2-way Globe Control Valve, threaded port connection, DN 10-65

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

INLINE sensor-fitting with paddle wheel for flow measurement

INLINE fitting with paddle-wheel for flow measurement

Flow Transmitter / Switch OMNI-RR..32

Type SE36

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Flow Transmitter / Switch OMNI-RR..32

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

2100 Turbine Flow Sensor

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Operating Instructions (from serial number )

2/2 way Angle-Seat Valve for medium up to C, DN15-50

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

2/2- and 3/2-way solenoid valve for aggressive fluids

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

Pressure sensor for liquid and gaseous media QBE620-P...

Direct-acting 2/2- or 3/2-way pivoted armature valve

Level Measurement Point level measurement - RF Capacitance switches

Pneumatic control unit for decentralized automation of ELEMENT process valves

Continuous level measuring system NB 4000 Selection list

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

JUMO ecotrans Lf 01/02

Flow Transmitter / Switch OMNI-RR..32

Signet 2551 Magmeter Flow Sensor

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Electric actuators type EA25-250

2/2 or 3/2 way direct acting rocker solenoid valve

INLINE fitting with paddle-wheel for flow measurement

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

2/2 or 3/2-way Miniature Rocker Solenoid Valve

Model Pressure range ON/OFF output Linear output

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Industrial OG meter series IOG Inline and flanged oval gear meter

Flowmeter for Gases. Type Type can be combined with... Type 8802-YG Process control valve. Type 5281 Solenoid valve

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

POSITIVE DISPLACEMENT FLOWMETER

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

Pressure sensors - Nautilus

macnaught flow measurement

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Signet Pressure Transmitter

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

Signet Temperature Transmitter

Technical Features Flow Monitor Part No. Wire Associated Sensor 4-20 ma Digital Relay Power Tech. Sensor Input Output Output Output F9.00.L 2 wire Hal

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Operating Manual Model- P282 Digiflow Controller

Differential pressure sensor

Continuous level measuring system NB 3000 Selection list. Overview

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

InBin-P Pressure switches 5 Pa Pa

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

8000 Series Liquid Flow Meters

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

Transcription:

8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total and daily totalizers for batch quantity and number of batches, volume or mass totalizers displayed Type 2100 (8692) Type 8792 Type 8644-P AirLINE PLC Control valve with TopControl Continuous SideControl Valve island with electronic I/O This positive displacement flow batch controller with display is designed for use in slightly viscous fluid like glue, honey or oil. The batch controller is made up of a compact sensor fitting (S070) and an electronic module (SE35) quickly and easily connected together by a Quarter-Turn. Technical data General data Compatibility Materials Housing, cover, lid, nut Front panel foil / Screws Cable glands Wetted parts materials Sensor fitting Rotor Shaft / Seal Display with fittings S070 (see corresponding data sheet) PC Polyester / Stainless steel PA Aluminium, stainless steel (316F/1.4401) PPS, Aluminium, stainless steel (316F/1.4401) Stainless steel / FKM or FEP/PTFE 15 x 60 mm, 8-digit LCD, alphanumeric, 15 segments, 9 mm high Electrical connections Cable glands M20 x 1.5 Recommended cable max. 50 m, shielded, 1.5 mm 2 max. cross-section Device data (Fitting S070 + Electronics) Pipe diameter DN15 to DN100 Measuring range 2 to 1200 l/min (0.26 to 320 gpm) for viscosity > 5 mpa.s 3 to 616 l/min (0.78 to 320 gpm) for viscosity < 5 mpa.s Fluid temperature Aluminium body Stainless steel body Fluid pressure max. DN15 DN25 DN40, DN50 / DN80 / DN100 Viscosity Accuracy Programming mode Repeatability 1) or in accordance to the value of the used flanges 0 to 80 C (32 F to 176 F) 0 to 100 C (32 F to 212 F) 55 bar (798 PSI) (threaded process connection) 55 bar (798 PSI) 1) 18 bar (261 PSI) / 12 bar (174 PSI) / 10 bar (145 PSI) 1 Pa.s max. (higher on request) ± 0.5% of Reading Threshold, window or hysteresis 0.03% of Reading www.burkert.com p. 1/6

Electrical data Power supply (V+) Reversed polarity of DC Current consumption with sensor (without consumption of digital input and pulse output) Inputs DI (1 to 4) Outputs Transistors (DO1 and DO4) Relays (DO2 and DO3) 12-36 V DC (max tolerance: -5% or +10% at 12 V DC; ±10% at 36 V DC), filtered and regulated, SELV (safety extra low voltage), circuit with a non dangerous energy level or 115/230 V AC 50/60 Hz (see technical specifications 115/230 V AC) protected with relays 90 ma at 12 V DC; 45 ma at 36 V DC Switching threshold Von: 5... 36 V DC; Switching threshold Voff max: 2 V DC; Input impedance: 9.4 KOhms; Galvanic insulation, protected against polarity reversals and voltage spike NPN or PNP (wiring dependent), potential free; function: pulse output (by default for DO1), batch state (by default for DO4), configurable and parameterizable 0.6-2200 Hz, 5-36 V DC, 100 ma max., line drop 2.7 V DC at 100 ma duty cycle: > 0.45 if 0.6 < frequency < 300 Hz > 0.4 if 300 < frequency < 1500 Hz < 0.4 if 1500 < frequency < 2200 Hz Galvanic insulation, protected against overvoltage, polarity reversals and shortcircuits 2 relays (normally open), parameterizable (by default: DO2 always configured to control the valve, parameterized of 100% of the batch quantity and DO3 configured as alarm), 230 V AC/3 A or 40 V DC/3 A (resistive load), max. cutting power of 750 VA (resistive load) Environment Ambient temperature (operation and storage) Height above sea level Relative humidity -10 to +60 C (14 to 140 F) (version 12-36 V DC) -10 to +50 C (14 to 122 F) (version 115/230 V AC) max. 2000 m 80 %, without condensation Standards, directives and approvals Protection class IP65 with cable gland mounted and tightened or with obturator locked if not (according to EN60529) used. Standard and directives EMC Security Pressure (Fitting S030, DN06 to DN65, in PVC, PP, PVDF, stainless steel or brass) Vibration Shock Approvals EN 61000-6-2, EN 61000-6-3 EN 61010-1 Complying with article 3 of chap. 3 from 97/23/CE directive.* EN 60068-2-6 EN 60068-2-27 CE; UL-Recognized for US and Canada (61010-1 + CAN/CSA-C22 No.61010-1) Specific technical data of UL-recognized products for US and Canada Relay output 30 V AC and 42 V peak max. or 60 V DC max. Ambient temperature -10 to +60 C (14 to 140 F) Relative humidity max. 80 %, without condensation Intended for an inner pollution Installation category Grade of pollution 2, according to EN61010-1 Category I, according to UL61010-1 * For the 97/23/CE pressure directive, the device can only be used under following conditions (depend on max. pressure, pipe diameter and fluid). Type of fluid Fluid group 1,chap. 1.3.a Fluid group 2,chap. 1.3.a Fluid group 1,chap. 1.3.b Fluid group 2,chap. 1.3.b Conditions Forbidden DN 32, or DN > 32 and PN*DN 1000 PN*DN 2000 DN 200 Technical specifications 115/230 V AC Voltage supply 27 V DC regulated available inside the device max. current: 125 ma integrated protection: fuse 125 ma temporised power: 3 VA Design and principle of operation The 8075 batch controller is built up with an SE35 electronic module associated to a sensor fitting S070 with integrated measurement oval rotor. The connection is made by means of a Quarter-Turn. The output signals are provided via two cable glands. If liquid flows through the pipe the rotor turns. This rotation produces a measuring signal in the transducer. The frequency is proportional to the flow of the fluid. A conversion coefficient (K factor, available in the instruction manual of the sensor fitting S070), specific to each pipe (size and material) enables the conversion of this frequency into a volume or a mass. The electronic component converts the measured signal and displays the actual value of the volume or mass. p. 2/6

Operation and display When mounted in a pipe in series with one or two valves, the 8075 batch controller makes it possible to carry out a dosing of one or several quantities of liquids. The unit controls the opening of the valves and measures the quantity of the fluid which flows. The unit also closes the valves when the preset quantity has been delivered. The electronic component needs a voltage supply of 12-36 V DC or 115/230 V AC. The device is equipped with 4 digital inputs (DI1 up to DI4), 2 transistor outputs (DO1 configured as a pulse output and DO4 configured as state output, by default), 2 relay outputs (DO2 always configured to control the valve and by default parameterize of 100% of the batch quantity and DO3 configured as alarm output by default), two volume or mass totalizers and two batch totalizers. The second relay output can be used to activate another valve, to initiate alarms or to generate warnings. The following dosing modes are possible: - Locally started dosing of free quantity: the user enters the quantity to be filled and starts the dosing from the keypad. - Locally started dosing of preset quantity: the user selects a quantity which has been preset and starts the dosing from the keypad. - Locally started dosing of free/preset quantity the user enters the quantity to be filled or selects a quantity which has been preset and starts the dosing from the keypad. - Dosing controlled by a PLC unit the user selects a quantity which has been preset and starts the dosing using binary inputs. - Locally/remote selection of preset quantity and dosing controlled by a PLC unit: the user selects a quantity which has been preset from the keypad or using binary inputs and starts the dosing using binary inputs. - Automatic dosing controlled by variation of pulse duration: the quantity of the dosing is directly proportional to the duration of a pulse. - Remote dosing determined by Teach-In: Teach-In of the dosing quantity using binary inputs. - Local dosing determined by Teach-In: Teach-In of the dosing quantity from the keypads. The device is calibrated by means of the K-factor which is either entered or determined via the Teach-In functions. User adjustments, such as measuring range, engineering units, pulse output, etc. are carried out via the device operators interface. The operation is specified according to five levels: Indication in operating mode/ display Parameter definition Test Information History dosing amount dosing mode main quantity totalizer daily quantity totalizer with reset function main batch totalizer daily batch totalizer with reset function language engineering units K-factor/Teach-In function selection of dosing mode over run correction alarm outputs configuration reset both quantity/batch totalizers (main and daily) Brightness of the display (backlight) input test output test frequency test warning and fault messages generating configuration mode Display of error, alarm and/or warning messages Display of the 10 latest batches p. 3/6

Description of the navigation keys and the status LEDs Scrolling up the parameters within a level or a menu Increase the figure selected Read the batches history Reading the messages in the information menu Scrolling down the parameters within a level or a menu Selecting the figure on the left Device status LED: see following table. Large digital display with 8 characters Selecting the displayed parameters Validating the settings Status LED of relay DO3 (LED ON = contact closed) Status LED of relay DO2 (LED ON = contact closed) Device status LED Green Orange Red Blinking, whatever the colour Status of the device The device operates correctly. A dosing related alarm and/or a warning messages is generated in the information menu. A fault message is generated in the information menu. Slow blinking: The dosing is interrupted. Fast blinking: - during a dosing: a dosing related alarm is generated. - dosing not active: the information menu has been remote-consulted or a check for the correct behaviour of the inputs/outputs is running. Installation The sensor fitting can be installed in any orientation as long as the rotor shafts are always in a horizontal plane (see figures to the right) and the flow of the fluid is in the direction of the arrow marked on the body. Correct Incorrect The pipe must be filled with liquid and free from air bubbles. Avoid air purge of the system which would cause damages and to prevent damage from dirt or foreign matter, we strongly recommend the installation of a 250 m flow straightener as close as possible to the inlet side of the meter. p. 4/6

Dimensions [mm] Electronics SE35 180 116 88 21 91 88 DN H 15 140 25 155 105 75 104 114 H 40 172 50 190 80 230 100 231 DN15 DN25 DN40 DN50 DN80 Threaded connection DN25 DN40 DN50 DN80 Flanged connection DN100 p. 5/6

Ordering information for compact batch controller Type 8075 A batch controller Type 8075 consists of an electronics Type SE35 and a Bürkert INLINE sensor fitting Type S070 The following information is necessary for the selection of a complete device: Item no. of the desired electronics Type SE35 (see Ordering chart, below) Item no. of the selected INLINE sensor fitting Type S070 (see separate data sheet- has to be ordered separately) You have to order two components. When you click on the orange box More info. below, you will come to our website for the resp. product where you can download the data sheet. Example Electronics Type SE35 Complete batch controller Type 8075 INLINE sensor fitting Type S070 Ordering chart for electronics Type SE35 All these versions have as minimum: 2 transistor outputs (DO1 and DO4) 2 relay outputs (DO2 and DO3) 4 digital inputs (DI1... DI4) 2 quantity totalizers 2 batch totalizers Specifications Voltage supply Sensor version Electrical connection Item no. Batch controller, compact version 12-36 V DC Hall 2 cable glands 443 360 Batch controller, compact version, 12-36 V DC Hall 2 cable glands 564 398 UL-Recognized for US and Canada Batch controller, compact version 115/230 V AC Hall 2 cable glands 423 926 NOTE: For remote version, please refer to data sheet Type 8025 Batch controller Ordering chart - accessories for batch controller Type 8075 (has to be ordered separately) Specifications Item no. Set with 2 cable glands M20 x 1.5 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x 1.5 + 2 multiway 449 755 seals 2 x 6 mm Set with 2 reductions M20 x 1.5 /NPT1/2 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x 1.5 551 782 Set with 1 stopper for unused cable gland M20 x 1.5 + 1 multiway seal 2 x 6 mm for cable gland + 1 black EPDM seal for the 551 775 sensor + 1 mounting instruction sheet Set with 8 FLOW foils 553 191 To find your nearest Bürkert office, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1304/3_EU-en_00895142 p. 6/6