ELECTRICAL ENGINEERING & COMPUTER SCIENCE NEWSLETTER Volume

Similar documents
Comparison of short circuit current by difference of gap length between wall outlet and tracking resistance

ELECTRIC STRESS ANALYSIS ON 11KV INSULATOR

Issued by : Switchgear Contracts Division LARSEN & TOUBRO LIMITED Powai Works, Mumbai October December 1996

High Voltage Technology & Testing

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

PROVIDING ACCURATE DATA IN A TIMELY MANNER

Welcome to KEMET Electronics Corporation s introduction to protection against surface arcing on high voltage MLCC training module.

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Minnesota Dept. of Commerce, Division of Energy Resources. Distributed Generation Workshop Interconnection Standards

Contents. 1 Introduction. 2 General Product Information. 3 General Test Requirements

CHAPTER 3 CAUSES AND EFFECTS OF ELECTRICAL FAULTS

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

POWER CAPACITORS. Cylindrical capacitor standard duty

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

Supercapacitors: A Comparative Analysis

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

PhaseCap HD Capacitors for Power Factor Correction

Shaft Grounding Rings. Protecting VFD Driven Motors from Bearing Currents

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Oil Test Cell Catalog No

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

by Jim Phillips, P. E.

Transformer bushings, type GOH. Technical guide

Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series kv

Technical Guide for Basic Switches

E-15 Uninterruptible Power Systems (UPS)

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

A Particulate Matter Sensor with Groove Electrode for Real-Time Diesel Engine On-Board Diagnostics

VALIADIS S.A. HELLENIC MOTORS

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

PPC Porcelain Solid Core Post Insulators and Operating Rods ANSI

Field Experience & Reliability Tests for the New EasyDry Condenser Bushing LUKAS MUGGLI

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

General information about motor protection

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

CATALOGUE. Connecting devices for actuators and sensors Proximity switches

Development of Large-capacity Indirect Hydrogen-cooled Turbine Generator and Latest Technologies Applied to After Sales Service

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

FUSE TECHNOLOGY Ambient temperature

AF series contactors (9 2650)

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

EXPERIMENTAL STUDY OF DYNAMIC THERMAL BEHAVIOUR OF AN 11 KV DISTRIBUTION TRANSFORMER

Passive Vibration Reduction with Silicone Springs and Dynamic Absorber

Distribution of Electric Field Analysis in 36 kv Roof Top Bushing by using FEM Techniques

Design and Development of Micro Controller Based Automatic Engine Cooling System

Investigating The Effect of Switching and tripping on Flashover and Breakdown in Circuit Breaker

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Wheels for a MEMS MicroVehicle

PhiCap Capacitors for Power Factor Correction

Technical appendix. Contents. Technical appendix. Technical appendix W.1. Materials W.2. Clearances and creepage distances W.4

Service Guide for XUGUANG Electron Tubes

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Analysis of Generator Stator Remaining Breakdown Voltage for Power Plant

Real-Time Simulation of A Modular Multilevel Converter Based Hybrid Energy Storage System

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Product Data Sheet 624 NR. The engineer's choice

AF series contactors (9 2650)

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Geometric vs. Capacitive Stress Control: choosing cable termination accessories to help reduce electrical stress.

Performance Evaluation of Electric Vehicles in Macau

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

Electric Field Modelling of Non-Ceramic High Voltage Insulators

Shaft Grounding Ring Application Notes:

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

POLYAMIDE SCREW CLAMP TERMINAL BLOCKS

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

CERTIFICATION REVIEW ITEM

A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

G PULLAIAH COLLEGE OF ENGINEERING & TECHNOLOGY DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

8DJ. Maintenance-free for lifetime

SPECTROSCOPIC DIAGNOSTIC OF TRANSIENT PLASMA PRODUCED BY A SPARK PLUG *

IMPROVEMENT ON MOUNTING THERMAL RESISTANCE BETWEEN A CIRCUIT BOARD WITH MANY COMPONENTS AND A LIQUID-COOLED COLD PLATE

Overview Overvoltage protection

Generic Requirements for Outdoor Telephone Network Interface Devices (NIDs)

General Purpose Relays Accessories. Accessories Industrial Power Relay RT

Design Standards NEMA

Intelligent Control Algorithm for Distributed Battery Energy Storage Systems

Visual comparison of Plain & Hazy PP Film

In general this document presents specific safety procedures for systems with potentially lethal voltages on bare or exposed conductors.

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Eskom s unique type test requirements for lightning surge arrester ground lead disconnectors

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Product Data Sheet 632 NU-006

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

An Alternative to Reduce Medium-Voltage Transient Recovery Voltage Peaks

AGN 012 Environmental Rating Factors

Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors

ELECTROMAGNETIC INDUCTION. FARADAY'S LAW

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Transcription:

ELECTRICAL ENGINEERING & COMPUTER SCIENCE NEWSLETTER Volume 4 2016 Electrical Conductor Spacing Standards for Printed Circuit Boards Authors: Sonal Kothari Phan, Ph.D.; Jeremiah Stepan, Ph.D., P.E.; Benjamin Cotts, Ph.D., P.E. Reviewer: Brian D Andrade, Ph.D., CRE, P.E. Exponent consultants routinely investigate printed circuit board (PCB) failures, and one particular failure mode routinely encountered is the formation of conductive paths between electrical components or traces. Such paths are often enabled by placing elements on a printed circuit board too close to one another. The two most important spacing distances are the shortest distance through air between any two conductors (clearance distance), and the linear distance traveled over the surface of the PCB between any two conductors (creepage distance). Both of these distances are determined by the voltage used on the PCB. Proper selection of electrical conductor spacing on printed circuit boards is important not only for proper circuit operation, but also for preventing electrical breakdown of insulating materials between conductors, which can result in the failure of a PCB. A breakdown along a clearance path occurs through the air (similar in concept to a carpet shock ) and is a fast phenomenon, in which damage is often caused by a very short duration impulse. Therefore, the required clearance spacing is determined using the expected maximum peak voltage, including transients, in circuits. In contrast, a breakdown along a creepage distance is occurs as a result of tracking (the electrical breakdown on the surface of an insulating material), which is a slow phenomenon and depends on DC or root mean square (rms) voltage levels rather than peak voltage. A circuit with inadequate creepage distances may last for days, weeks, or months before it fails. i Creepage distances are therefore important to the conductor spacings on a PCB, because the conductors on its outer layer are separated by the surface of the PCB, as opposed to being separated by air, and because creepage breakdowns typically occur over smaller distances than those associated with clearance breakdowns. Established minimum creepage distances are based on extensive studies of materials in specified conditions. For example, Day and Stonard studied the influence of insulation material and contamination on tracking and flashover in 1977. ii The results of the study showed that tracking resistance (i.e. the ability to mitigate tracking) increases with creepage distance, decreases with voltage, and depends on the material characteristics of the insulating medium.

In the early 1980s, several research projects related to insulation coordination were conducted by a study group that included 27 German and 9 U.S. manufacturers. iii The main objective of the set of projects was to study the effects of environmental pollution on insulating materials and to improve the dimensioning rules for creepage and clearance distances. The study produced the new dimensioning rules shown in Figure 1, categorized by pollution degree and material group. iv No. Pollution Degree Material Group 1 1 I-IIIb 2 2 I-IIIb 3 3 I-IIIb 4 4 I 5 4 IIIa 6 1 I-IIIb 7 2 I-IIIb 8 3 I 9 3 IIIb 10 4 I 11 4 IIIa Figure 1. Proposal for creepage and clearance distances based on rated impulse voltage The influences of humidity, corrosive atmosphere, and dust deposition on insulation resistance were documented in another study of more than 30,000 insulators. v The author proposed dimensioning rules for clearance and creepage distances categorized by four micro environment categories: Category 1 includes insulators that are always kept clean and dry in an environment with less than 75% relative humidity and no salt containing dust Category 2 also includes insulators in an environment with less than 75% relative humidity but where deposition of saltcontaining dust is expected Category 3 includes insulators in an environment that is weather protected but is subjected to circulating outdoor air, and consequently, can be exposed to relative humidity as high as 95% for up to 100 hrs/year Category 4 includes insulators that are not weather protected.

Other researchers have conducted similar research to investigate factors affecting insulation coordination and have proposed creepage and clearance distances. In 1995, Maeda et al. examined the creepage breakdown characteristics of printed wiring boards in silicone gel and presented an experimental equation to calculate breakdown voltage based on creepage distance, intrinsic capacity, relative permittivity, insulation layer thickness, and electrode location. vi In 1997, Yamada et al. investigated AC creepage breakdown and impulse creepage flashover voltages on printed wiring boards in four different experimental environments. vii In 2004, Du et al. investigated the effects of temperature, pressure, signal frequency, and electric stress (voltage per unit length) on dielectric breakdown and discharge energy on printed circuit board. viii The results of research on creepage and clearance were eventually incorporated into standards, including Underwriters Laboratories (UL) 840, which is one to consider when designing PCBs to meet clearance and creepage distance requirements. UL 840 is a standard for Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment. In addition to defining clearance and creepage distances, UL 840 also accounts for the amount of contamination to which the electronics might be exposed (Degree of Pollution), as well as the material properties of the insulating medium between conductors (Material Group). UL 840 defines the various degrees of pollution as follows: ix Pollution Degree 1 No pollution, or only dry, nonconductive pollution. The pollution has no influence. Pollution Degree 2 Normally, only nonconductive pollution. However, a temporary conductivity caused by condensation can be expected. Pollution Degree 3 Conductive pollution, or dry, nonconductive pollution that becomes conductive due to condensation that is expected. Pollution Degree 4 Pollution that generates persistent conductivity through conductive dust or rain and snow. UL 840 defines the materials groups based on the Comparative Tracking Index (CTI), which is determined in accordance with International Electrotechnical Commission (IEC) 60112 (or UL 746, ASTM D 3638). CTI is a voltage that enables tracking after 50 drops of ammonium chloride solution have fallen on the material. Tracking is an electrical breakdown on the surface of an insulating material that occurs when a voltage difference gradually creates a conductive leakage path across the surface of the material by forming a carbonized track. x

The standards on creepage and clearance distances vary among industries and equipment applications. Although UL 840 provides general guidance, other standards may be applicable based on a particular application. For example, UL 61010 1 is an electrical equipment standard for measurement, and UL 2735 is a standard for smart meters. Both have requirements for clearance and creepage distances. The reliability of printed circuit boards used in electronics depends strongly on the design decisions regarding clearance and creepage distances. Several research studies and industry standards provide guidance regarding the selection of appropriate clearance and creepage distances, depending on the device voltage rating, materials used, and degree of pollution. Exponent has broad experience with creepage standards and has helped clients understand how inappropriate creepage distances produce device failures after extended periods of operation in various pollution environments. For Further Information, Contact: Sonal Kothari Phan, Ph.D. Associate (678) 412 4824 skothari@exponent.com Jeremiah Stepan, P.E., CFEI Managing Engineer (310) 754 2743 jstepan@exponent.com Benjamin R.T. Cotts, Ph.D., P.E. Managing Engineer (301) 291 2519 bcotts@exponent.com

References i ii iii iv v vi vii viii ix x Y. Liu. 2012. Power package electrical isolation design. Power electronic packaging. Springer, New York, pp. 9 26. Day, A.G., and D.J. Stonard. 1977. Creepage and clearance distances in electrical equipment for shipboard use. Electrical Insulation, IEEE Transactions EI-12(3):191 199. Schau, P.V., and W.H. Middendorf. 1983. An international research project to determine new dimensioning rules for creepage distances. Electrical Insulation, IEEE Transactions EI-18(2):158 162. Pfeiffer, W., K. Richter, and P.V. Schau. 1984. Electric strength of small creepage distances under natural environmental conditions. Electrical Insulation, IEEE Transactions 6:586 593. Stimper, K. 1990. Physical fundamentals of insulation design for low-voltage equipment. Electrical Insulation, IEEE Transactions 25(6):1097 1103. Maeda, T., and K. Haga. 1996. Creepage breakdown characteristics of printed wiring board in silicone gel. Electrical Insulation and Dielectric Phenomena, IEEE 1996 Annual Report of the Conference on Electrical Insulation and Dielectric Phenomena. Vol. 2. Yamada, S., K. Okamoto, and K. Haga. 1997. AC and impulse breakdown of polluted surface on printed wiring board. Electrical Insulation Conference, 1997, and Electrical Manufacturing & Coil Winding Conference, Proceedings, IEEE. Du, B.X., J. Xiao, and X. Zhang. 2004. Dielectric breakdown and discharge energy on printed circuit board. Solid Dielectrics, ICSD 2004. Proceedings of the 2004 IEEE International Conference, Vol. 1. Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment. UL 840-2007, p. 14. See IEC 60112 Test Standard Explained at http://www2.ulprospector.com/property_descriptions/iec60112.asp. Accessed on October 15, 2015.