UL TEST REPORT AND PROCEDURE

Similar documents
UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

UL TEST REPORT AND PROCEDURE

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

COVER PAGE FOR TEST REPORT

Max. Input Power (W) Inrush Current (A pk /µs)

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

E A51-UL 2014-September-02 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT

for the use of SIQ Type Approved certification mark 51-SIQ BG 004/130 Project file: C DIN Rail Power Supply

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Certificate of Compliance

SPECIFIC TECHNICAL CRITERIA

RUZ- _/_ Protection (3) Isolation Option (4)

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

Certificate of Compliance

C E R T I F I C A T E O F C O M P L I A N C E

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

File E Project 01ME August 14, 2001 REPORT

FR circuit breaker - hydraulic magnetic,

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

COVER PAGE FOR TEST REPORT

Certificate of Compliance

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

YCCS Zone/Bypass Damper Assembly

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Max. Input Power (W) Input Current. Inrush 347V Vin 60/ C. 480V Vac Vin 85 / 115. Dimming Method.

Certificate of Compliance

Load (2) Single or Dual

T2111EN Technical Data Sheet Rev 04 Air Cooled Rectifier Bridge MVR : 690V, 1600Adc

Certificate of Compliance

PRODUCTS: POWER SUPPLY

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

AR circuit breaker - Hydraulic magnetic,

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

RECHARGEABLE LITHIUM-ION BATTERIES FOR SYSTEMS

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V

AT30 SERIES BATTERY CHARGER

Testing Power Supplies for Medical Electronics Applications

PDR circuit breaker - Ground fault Datasheet

File E Project 00SC October 9, 2000 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

RBR circuit breaker - Remote operated

Harmonization of IEC and North American Safety Standards

BR Second Position Voltages. AA Fourth Position

BATTERY CHARGERS NO. 3

E-Series and EF-Series Systems

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

Product Data Sheet ACi 4420 HHR

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Low Voltage Directive Report

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES

Power Supply XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA

IFICA IO T ON SHEET FOR LED PORTABLE LUMINAIRE WITH EMERGENCY FUNCTION EXL 660P

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

PowerWave 33 Efficient power protection for today s IT and process-related work environments

COVER PAGE FOR TEST REPORT

Product Data Sheet 4118 N/ The engineer's choice

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

Scheda prodotto Relè Series E

Printed Board Cemented Joint Program Based on UL/IEC and IEC

Product Data Sheet 632 NU-006

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

Information technology equipment Safety Part 1: General requirements

IECEx Certificate of Conformity

Products :: Circuit Protection :: Thermal Circuit Breakers

UL TEST REPORT AND PROCEDURE

File E Project 00SC June 22, 2000 REPORT POWER SUPPLY ADAPTER INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

PD-Series Ground Fault Circuit Protection

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter

YCCS Zone/Bypass Damper Assembly

Technical Specifications

Transcription:

Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) Switching Power Supply for Building-in DS800SL-3 Input rating: 100-120 / 200-240VAC, 50/60 Hz 10A max. Output rating: +12VDC 66.7A max. +5Vsb 4.0A max. Maximum continuous output power is 800W. Applicant Name and Address: ASTEC INTERNATIONAL LTD 16TH FL LU PLAZA 2 WING YIP ST KWUN TONG KOWLOON HONG KONG This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Suki Kwong Reviewed by: Michael Neuffer Copyright 2012

Issue Date: 2012-03-23 Page 2 of 16 Report Reference # E186249-A202-UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. Product Description The equipment is a Class I power supply for building-in provided with metal enclosure and ventilated by one fan. For use in Information Technology Equipment. There are two construction designs, Construction A and Construction B respectively. Model Differences Power Supply in Construction B is identical to Construction A except for the airflow direction and heatsink dimension. Construction A: Fan Airflow direction is towards the AC inlet (going out of the unit) away from the primary components. Construction B: Fan Airflow direction is towards the primary components. Moreover, output power derating condition for Construction B is defined as follows: At 100 Vac to 120 Vac input: a.) Max. Output Power would be 770 W at 25 deg C. b.) Max. Output Power would be 750 W at 30 deg C. c.) Max. Output Power would be 700 W at 40 deg C. d.) Max. Output Power would be 640 W at 50 deg C. At 200 Vac to 240 Vac input: a.) Max. Output Power would be 800 W at 25 deg C. b.) Max. Output Power would be 800 W at 30 deg C. c.) Max. Output Power would be 755 W at 40 deg C. d.) Max. Output Power would be 700 W at 50 deg C. At 100Vac to 120Vac input 1. Output derates 4W per degree from 25degC to 30degC ambient temp. 2. Output derates 5W per degree from 30degC to 40degC ambient temp. 3. Output derates 6W per degree from 40degC to 50degC ambient temp. At 200Vac to 240Vac input

Issue Date: 2012-03-23 Page 3 of 16 Report Reference # E186249-A202-UL 1. Output derates 4.5W per degree from 30degC to 40degC ambient temp. 2. Output derates 5.5W per degree from 40degC to 50degC ambient temp. Technical Considerations Equipment mobility : for building-in Connection to the mains : pluggable A Operating condition : continuous Access location : operator accessible Over voltage category (OVC) : OVC II Mains supply tolerance (%) or absolute mains supply values : +10%, -10% Tested for IT power systems : No IT testing, phase-phase voltage (V) : - Class of equipment : Class I (earthed) Considered current rating of protective device as part of the building installation (A) : 15 A Pollution degree (PD) : PD 2 IP protection class : IP X0 Altitude of operation (m) : 3048 Altitude of test laboratory (m) : less than 2000 meters Mass of equipment (kg) : 1.25 The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 50 C, The means of connection to the mains supply is: Pluggable A. Cord set not provided with the equipment. The product is intended for use on the following power systems: TN

Issue Date: 2012-03-23 Page 4 of 16 Report Reference # E186249-A202-UL The equipment disconnect device is considered to be: Appliance inlet The class of laser product is: Class 1 (I) The product was investigated to the following additional standards: EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011(which includes all European national differences, including those specified in this test report). The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual LEDs provided in the product are considered low power devices: Yes This equipment is intended to operate in a "normal" environment (offices and homes). This equipment is not an electromedical equipment intended to be physically connected to a patient. The clearances and creepage distances have additionally been assessed for suitability up to maximum 10,000 ft (3048m) elevation. Clearance distances are calculated according to IEC60664-1 table A-2, multiplier factor is 1.15. Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The following Production-Line tests are conducted for this product: Electric Strength The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary- SELV: 391 Vrms, 592 Vpk, Primary-Earthed Dead Metal: 391 Vrms, 592 Vpk The following secondary output circuits are SELV: +12V and +5Vsb outputs The following secondary output circuits are at hazardous energy levels: +12V output The following secondary output circuits are at non-hazardous energy levels: +5Vsb The power supply terminals and/or connectors are: Not investigated for field wiring The maximum investigated branch circuit rating is: 20 A The investigated Pollution Degree is: 2

Issue Date: 2012-03-23 Page 5 of 16 Report Reference # E186249-A202-UL Proper bonding to the end-product main protective earthing termination is: Required An investigation of the protective bonding terminals has: Been conducted The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105 C): T1, T2, T3 and T4 - Class 155 (F) designated 155-10A, 155-10B or 155-10C. The following end-product enclosures are required: Mechanical, Fire, Electrical The maximum continuous power supply output (Watts) relied on forced air cooling from: The equipment is suitable for direct connection to: AC mains supply The fans included as part of this component are suitable for use in a user access area: No This power supply has a secondary output (+12V) exceeding 240VA. When installing in the end system care must be taken that this secondary output and the appropriate wires may not be touched. The disconnection from the line must be considered in the end system. This equipment is classified as Level 6 as defined by UL 60950-1, 2nd Edition and CAN/CSA C22.2 No. 60950-1-07 2nd edition. This equipment was not evaluated for end system mounting. Proper evaluation should be considered when installed in the end system. This power supply is not equipped with a power cord. A safety approved power cord and plug with appropriate wire gauge for the rated input current and suitable for country of application must be provided by the end system manufacturer. The maximum continuous power supply output (Watts) relied on forced air cooling of construction A and construction B from: one fan provided on the unit blowing air from the inside to outside of the power supply towards the front panel (ac inlet) area for construction A and reverse airflow direction for construction B. See critical components list for details.