WAY MOTORISED COMPACT ZONE VALVES

Similar documents
CT3202.0_01 EN February 2018

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

Pressure Independent Control Valve

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

PRESSURE INDEPENDENT CONTROL VALVE

SELF-CLEANING FILTER

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

Fan-coil valves Series

80% Max working pressure: Max working temperature: 70 C. Flow-meter regulation range: Flow meter-regulation range: ± 10%

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

Art.918C Pre-assembled manifold with flow meters, air

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

22C, 22CX, 22CX5, 26LC Series

Terminator PICV. Technical Manual

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 10/ ENG

SINGLE MANIFOLDS TECHNICAL DATA SHEET10/ ENG

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

VE-S_15-32 Pressure Independent Balancing & Control Valves

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

TECHNICAL CATALOGUE. Electrothermal actuator

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

Preassembled manifolds with flow meter, series CPRFL

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

Pre-assembled distribution manifolds for radiant panel systems

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

599 Series Zone Valve Bodies:

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

MOTORISED BALL VALVE. Uni/Bi-directional. patented. 3 points 2 points Price list root SR... SS... SY... Connection with ball valve.

PRE-ASSEMBLED MANIFOLD KIT 1 TECHNICAL DATA SHEET 09/ ENG

7 ZONE VALVES. Applications

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

2-Port and 3-Port Zone Valves, PN 16 / 20

CALEFFI. zone valves. Z series 01115/14 NA. Replaces 01115/11 NA. Function

Servo-operated 2/2-way solenoid valves Type EV220A

24 V AC/DC, -10%..+20%, 0-60Hz. 250 ma for max 2 min

Pressure Independent Control Valve. Technical manual

Connections (*) Rev. f 04/08 1 DBL199E

2-Port and 3-Port Zone Valves & Actuators, PN16

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

2-Port and 3-Port Zone Valves, PN16

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

ACVATIX MiniCombiValves (MCV)

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

Thermostatically controllable valves art. VD/VS/VCR/VCD/VCS xxxx

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

R EGI S TERED. Function

TECHNICAL CATALOGUE AUTOMATIC AIR-VENT VALVES

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

VG6000 Series Forged Brass Valves

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

Serie Ekoflux S. Flanged balancing valve. Application fields. Regulation. Ekoflux.S_GB_22/04/2015 HEATING CONDITIONING

Sinro Controls HVAC. Balancing made simple with Sinro Balancing Valve PRODUCTS. Flow Balancing Modulating Valve

TECHNICAL MANUAL SOFFIO Ducted units

2-position electric actuators with Ball valves VBZ ½...11/4

ZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position

Automatic balancing valves ASV-PV DN (3rd gen.)

Gruppi idraulici e raccordi

1 DESCRIPTION 2 WORKING PRINCIPLE 2.1 REGULATION ST

Pressure independent balancing and control valve

ACVATIX MiniCombiValves (MCV)

TECHNICAL CATALOGUE BALL VALVES: IDEAL

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

T2 Wall Hung Radiator & UFH Manifolds

Static Balancing Valve

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

lindab comfort Regula Control er

V9000 PICV Pressure Independent Control Valve

BASTONE (dual) fancoil Units

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

TECHNICAL CATALOGUE BALL VALVES: IDEAL

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

TECHNICAL CATALOGUE BLOCK CHECK AND FOOT VALVES

ZONE CONTROLE / 2-WAY

Pressure independent balancing and control valve AB-QM DN

something new in the air Technical Bulletin

TECHNICAL CATALOGUE EUROPA CHECK AND FOOT VALVES

Components for central heating

FLOW RATE STATIC BALANCING Valves for radiators

PNEUMATICALLY ACTUATED 2-WAY

Pressure Independent Control Valve. Technical manual R 8.3

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4"E. ( 3 4"x18) 3/4"E

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Connection and regulation kit for HVAC terminal units

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

Thermostatic radiator valves with presetting

Transcription:

2-3 - 4 WAY MOTORISED COMPACT ZONE VALVES CT0736.0_03 EN May 2015 ZONE 2C ZONE 4C ZONE 3C o o o Reduced overall dimensions; Extremely quiet operation; Valve with union connections. PRODUCTION RANGE Valve body Nominal size 3/4" 1" Code 2-way valves 814.05.20 814.06.20 Code 3-way valves 813.05.20 813.06.20 Code 4-way valves 736.05.20 736.06.20 Thermo-electrically controlled servo motor without and with auxiliary micro switch Servomotor Without auxiliary micro switch (2 wires) Code : 2944.00.02 Power supply: 230 V AC Code : 2944.00.12 Power supply: 24 V AC With auxiliary micro switch (4 wires) Code : 2944.00.42 Power supply: 230 V AC Code : 2944.00.52 Power supply: 24 V AC

Valve with handwheel for manual movement DESCRIPTION The Compact zone valve is a device that allows shutting-off or deviating (manual or automatic) the flow in transit. In the versions with two, three and four ways it is supplied, as standard, with a knob for manual opening and closing control; it can be easily automated by coupling it directly with a thermo-electric servo control from the series 2944.00.X2. USE The small dimensions and the limited hydraulic through sections make it particularly suitable for direct connection to the supply terminals or at the service of small heating areas. THE CHOICE There are no special precautions to be followed when choosing the Compact zone valve. In particular: The connection diameter must be chosen according to the diameter of the components or of the piping with which the valve must be coupled; in the offered production range the valve body and their internal passages, in fact, remain the same; As for all the rod-shutter valves, particular attention must be given to the differential pressure generated by the valve when the fluid passes. To guarantee the correct operation of the thermo-electric servo control, verify that the differential pressure across the valve does not exceed the value indicated in this technical data sheet. It is particularly indicated in the following cases: interception of small utilities in general; automatic shut-off of thermal zones to be coupled or not with coplanar manifolds; interception of power fan coils from circuits with two and/or four tubes. DIMENSIONAL FEATURES Code series 814-2-way compact zone valves A B C Dimension 814.05.20 3/4 143 69 16-814.06.20 1" 160.5 69 19.5 - D Code series 813-3-way compact zone valves A B C Dimension 813.05.20 3/4 143 69 76-813.06.20 1" 160.5 69 85 - D Code series 736-4-way compact zone valves A B C Dimension D 736.05.20 3/4 143 69 50 55 16 736.06.20 1" 160.5 69 50 55 19.5 CONSTRUCTION FEATURES Body Shutter and seal Rod seals Springs Handwheel manual opening Threaded connections Connection for ABS handwheel or thermo-electric servo control : M 30x1.5 : nickel-plated brass : EPDM : ethylene-propylene : stainless steel AISI302 : ABS : unions MM UNI-EN-ISO 228 TECHNICAL FEATURES Indicated fluid : clean water water + glycol 50% Fluid temperature : +5 +95 C Max. operating pressure : bar (0 kpa) Maximum differential pressure : 1 bar ( kpa) Valve stroke : 4 + 0.2 Predisposition for RBM electrothermal motors code 2944.00.X2. With mounted servomotor and electrically NOT POWERED the straight way of the compact zone valve is CLOSED. Technical Sheet CT0736.0-EN_03 RBM Page 2 of 7

Perdita di carico dapa 1daPa = 1,02 H2O Head loss dapa 1daPa=1.02 2O Pressure Perdita drop di kpa carico kpa Head loss dapa 1daPa = 1.02 H2O Perdita di carico dapa 1daPa = 1,02 H2O Perdita Pressure di carico drop kpa FLUID DYNAMIC FEATURES Motorised compact zone valves with electrothermally controlled servomotor series 2944.00.X2 Description Code Dimension 2-way valve 3-way valve 4-way valve Straight Kv (m 3 /h) By-pass Value of leakage Δp max (bar) 814.05.20 3/4 3.6-2.7 814.06.20 1 3.6-2.0 813.05.20 3/4 2.9 1.7 2.7 813.06.20 1 2.9 1.7 2.0 736.05.20 3/4 2.9 1.7 2.7 736.06.20 1 2.9 1.7 2.0 00 'OPEN' Valvola running funzione valve 'APERTO' Analytical procedure for determining the pressure drop for liquids with 1 0 3 and e 4 vie: ways: 3/4''- 3/4 1'' - 1 Q ΔP Kvs 2 00 valid for water with Temp. from 0 to 30 C 2 ways: vie: 3/4''- 3/4-1'' 1 correction of P for fluids with different from 1 ΔP' ΔP ρ 1 0,1 0 00 Flow Portata rate l/h l/h Motorised Valvole di zona compact compatte zone motorizzate valves with con electrothermal servocomando servomotor elettrotermico series 2944.00.X2 306.00.x2 Analytical procedure for the adjustment valve dimensioning valid for liquids with 1 0,5 00 Kvs Q * P valid for water with Temp. from 0 to 30 C kvs correction for fluids with different from 1 Kvs' Kvs ' 'BY-PASS' Valvola in funzione running 'BY-PASS' valve 00 Key 0 33 and e 4 vie: ways: 3/4''- 3/4-1'' 1 P = head loss in dapa P = correct head loss in dapa P max = pressure difference recoended for correct operation Q = flow rate in m 3 / h Kvs = hydraulic feature in m 3 / h ' = liquid density in 1 0,1 1 0 00 Portata Flow rate l/h l/h Motorised compact zone valves with Valvole di zona compatte motorizzate con electrothermal servomotor series servocomando elettrotermico serie 306.00.x2 Technical Sheet CT0736.0-EN_03 RBM Page 3 of 7

Cod. 2944.00.X2 Servomotor with electro-thermal control, with and without auxiliary micro switch DIMENSIONAL FEATURES TECHNICAL FEATURES Version without Micro switch with Micro switch Code 2944.00.02 2944.00.12 2944.00.42 2944.00.52 Operation N.C. N.C. N.C. N.C. Auxiliary switch NO NO YES YES Position indicator YES YES YES YES Voltage 230 VAC 24 VAC 230 VAC 24 VAC Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Input power in normal conditions Switching current auxiliary switch Connection Protection class Connection cable 2.5 W 2.5 W 2.5 W 2.5 W - - 3 A 3 A IP 54 assembly all installation IP 54 assembly all installation IP 54 assembly all installation IP 54 assembly all installation Opening time approx. 3 min approx. 5 min approx. 3 min approx. 5 min Stroke approx. 5 approx. 5 approx. 5 approx. 5 Max thrust 1 N 1 N 1 N 1 N Electrothermally controlled servomotor On-Off Application: Shutter valves activation On-Off. Functioning: Thermal activation, Normally Closed, with two (open / close). By electrically powering the servomotor, the thermostatic element is heated with wax expansion; after the heating period, the valve opens, quietly, making the stroke. By interrupting the electrical power supply the thermosensitive element is cooled with the consequent closure of the servomotor and of the relative valve coupled to it. Assembly: Simple direct assembly on the valve body by tightening the basic metal ring. Manual control: The servomotor does not allow manual activation in the case of failure; however, it is possible to manually activate the zone valve by simply removing the servomotor and reapplying the manual handwheel originally fitted on the valve. Auxiliary contact: If the logic of the system involves associating a status or alarm indicator when it reaches the open valve position, there is a specific version of the servo control with auxiliary micro switch with potential-free contacts free of voltage. Ambient temperature max 50 C max 50 C max 50 C max 50 C Certifications WIRING DIAGRAM Brown Blue Black Grey Typical principle diagram Technical Sheet CT0736.0-EN_03 RBM Page 4 of 7

INSTALLATION TIPS - The zone valves must be installed respecting the flow direction indicated by the arrows on the body of the valve itself. - The zone valves can be installed either with the electrothermal control servomotor facing upwards, in horizontal position or overturned. OK OK Degree of protection IP54! - The 2-way zone valve can be installed either on the delivery piping or on the return piping. - The 3-way zone valve must be installed only on the delivery pipe. - The 4-way zone valve, as well as being able to vary its distance from 50 to 55, always keeping the hydraulic seal, must be installed only on the delivery pipe. OK ASSEMBLY DIAGRAM VALVE - SERVOMOTOR CODE 2944.00.X2 OVERALL ASSEMBLY DIMENSIONS VALVE - SERVOMOTOR CODE 2944.00.X2 The compact zone valves are supplied, as standard, with the knob for the manual opening and closing control. To automate the valves, simply unscrew the ABS knob and fully tighten the electrothermal control servomotor up to the locking ring with a slight pressure. Do not use pliers, screwdrivers or other similar tools for this operation. If installing the valves in any plastic boxes, according to the type of assembly, leave sufficient space at the side or above the servo control to allow the replacement of the same. For this reason, we recoend the use of plastic boxes suitable for the containment of the compact zone valves, including the servo motor series 2944.00.X2. MAINTENANCE STUFFING PREMISTOPPA BOX STUFFING BOX OR GUARNIZIONE GASKET OR (To (Da be sostituire) replaced) A repair of the hydraulic sealing of the adjustment components can be carried out with the system running. First of all, remove the BS knob or the electrothermally controlled servomotor and unscrew the stuffing box using a spanner. Replace the O-rings gasket (code 5001.045) that is housed under the stuffing box itself. Then tighten the stuffing box up to the stop, making sure that the closing is forced slightly. The replacement of said O-ring gasket shows the condition of perfect functionality of the compact zone valve. Technical Sheet CT0736.0-EN_03 RBM Page 5 of 7

TYPICAL APPLICATIONS Figure 1 Application of the Compact zone 4-way valve, coupled with a coplanar distribution manifold. It is the classic application and allows interception of two or more thermally powered zones from a mutual pumping station. Figure 2 Application of the Compact zone 2- or 3-way valve in combination with a simple distribution manifold. This application is normally used to shut-off ceiling and/or wall radiant systems. The 2-way valve is recoended in combination with variable flow circuits. Figure 3 In addition to the classic application on 4-pipe fan coils, the growing increase of ambient comfort levels has recently favoured the application of the compact zone valve, even in the shutting-off of 2-pipe fan coils with season reversal. In these systems, the room thermostat normally acts directly on the operation of the on-board valve. This adjustment mode is acceptable in environments such as offices or shops. In places such as hotel rooms, nursing homes or residential bedrooms, the cyclical switch-on and off of the fan causes the continuous variation of the background noise of the environment, bothering people trying to sleep. It is, therefore, convenient for the human ear to get used to the constant background noise (fixed ventilation at minimum speed), by causing the intervention of the room thermostat directly on the compact zone valve. Technical Sheet CT0736.0-EN_03 RBM Page 6 of 7

SPECIFICATION ITEMS SERIES 814 2-way motorised compact zone valve. Normally closed with servo motor mounted, not powered. Nickel plated brass body. Obturator valve and seal in EPDM. Rod seals in ethylene-propylene. Stainless steel springs. Handwheel for manual opening in ABS. Predisposition for RBM electrothermal motors code 2944.00.X2. Union threaded connections MM UNI-EN-ISO 228. Max temperature 5... 95 C. Max. operating pressure bar. Differential pressure max. 1 bar. Available sizes 3/4 1". SERIES 813 3-way motorised compact zone valve. Normally closed on straight way with servo motor mounted, not powered. Nickel plated brass body. Obturator valve and seal in EPDM. Rod seals in ethylene-propylene. Stainless steel springs. Handwheel for manual opening in ABS. Predisposition for RBM electrothermal motors code 2944.00.X2. Union threaded connections MM UNI-EN-ISO 228. Max temperature 5... 95 C. Max. operating pressure bar. Differential pressure max. 1 bar. Available sizes 3/4 1". SERIES 736 4-way motorised compact zone valve. Normally closed on straight way with servo motor mounted, not powered. Can be coupled to Monoblock coplanar manifolds. Nickel plated brass body. Obturator valve and seal in EPDM. Rod seals in ethylene-propylene. Stainless steel springs. Handwheel for manual opening in ABS. Predisposition for RBM electrothermal motors code 2944.00.X2. Union threaded line connections MF UNI-EN-ISO 228. Centre distance 50...55. Max temperature 5... 95 C. Max. operating pressure bar. Differential pressure max. 1 bar. Available sizes 3/4 1". SERIES 2944 Thermo-electrically controlled servo motor for compact zone valves, complete with valve body clamping ring and electric power cable. Normally closed valve position when power missing. Power supply 24/230 V, consumption 2 W, frequency 50/60 Hz, electrical protection IP54, operating temperature 5...50 C, stroke 5. RBM spa reserves the right to improve and change the described products and related technical data at any moment and without prior notice: always refer to the instructions attached with the supplied components; this sheet is an aid, should the instructions be extremely schematic. Our technical department is always at your disposal for any doubt, problem or clarification. RBM Spa Via S.Giuseppe, 1 25075 Nave (Brescia) Italy Tel. 030-2537211 Fax 030-2531798 E-mail: info@rbm.eu www.rbm.eu Technical Sheet CT0736.0-EN_03 RBM Page 7 of 7