CoolWave 2 Transformer T3 and Wire Harness Upgrade Kit

Similar documents
CoolWave 2 Transformer T3 and Wire Harness Upgrade Kits

CoolWave 2 Phase Control Board and Cable Replacement Kit

Prodigy HDLV Manual System Installation Instructions

Rhino SD2/XD2 Electric Container Level Sensors for 125-mm Frames

Two Component Meter Cylinder Assembly Replacement

0 900 psi Pressure-Reducing Diaphragm Regulator

Description. Repair. Rhinor XD2 Type-H Low Level Drum Proximity Sensor. Replacing the Proximity Sensor

RU SERIES UPGRADE TempAssure Compatible

Installation Instructions for Series 3100V Low Level Indicator

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Pro-Swirl Manifold Air Heater

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

Sure Coat 90 Degree Spray Extension

Prodigy HDLV Generation II Manual System Installation Instructions

Prodigy HDLV Generation II Pump Panel

Electric Vibratory Box Feeder Retrofit Kit

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Repair. Description. Rhino SD2/XD2 Drum/Pail Level Indicators

Spray Pressure Control Manifold

Spray Pressure Control Manifold

TCU Flushing Manifold and RTD Installation

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

Field Replacement of Fluorescent Power Supply in L-858 Signature Series Sign

Inverted High Pressure Fluid Filters

Back Pressure Regulator

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

Encore HD Powder Spray System with Prodigy Pump Cabinet

E-200 Module Service Kit

Series 3000V Low Level Indicator

Prodigy HDLV Pump. Customer Product Manual Part A02

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

Mobile Powder Spray System Dolly with Hopper

Series AD-31 Handgun Swivel Connector Replacement Kit P/N and P/N

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

Description. Rhino EFD Bulk Unloader Packages

Prodigy to Encore HD Manual Powder Spray System Upgrade Kit

Colormax Powder Coating System Color Change Process

Models Affected: 2009 through 2012 Model Year GM 8.1 Propane Vision Models CORRECTIVE ACTION ---- PROCEDURE

Handyman Motor Capacitor Meter PART NO

One-Gun Add-On Kit For Smart-Coat Controllers

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Installation and Construction Notes for EVSE4

3094PM1ii (Model VS-24-11) & 3094PM4ii (Model VS-24-9)

Upgrading the Sure Coat Modular Gun Control System

OBSOLETE. RA-16 Rotary Atomizer Upgrade Kit. Instruction Sheet P/N A. 1. Introduction. 2. Disassembly

INSTALLATION GUIDE OWNER S GUIDE

Installing an H-200 Integral Right-Angle Module

Installation & Service Manual. Frameworx Tel-E-Foul. July 2005 /

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Sivoia QED R Installation Instructions Please Leave for Occupant

E-200 O-rings Service Kit

CARAVAN. Tow Vehicle Requirements Instructions. Various Models with 12-pin Plug. Fitting Time: 30 minutes

Encore HD Automatic System Standalone Pump Stand

DuraWatt DS12VD 140-Watt DC-DC 12 Volt Power Supply Short Form User Manual Version 1.0. Table of Contents

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Electrostatic System Checks

Master Power Brakes Electric Vacuum Pump Kit Various Applications P/N: AC9001K

LIGHTNING PROTECTION UNIT (LPU)

INSTALLATION INSTRUCTIONS AM rev. A

Standard and Conical AN Series Air Spray Nozzles

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

Soft Seat Fluid Pressure Regulator

Prodigy Mobile Box Unloader System

Spectrum VT Inline Powder Feed Pump

Miniature Soft Seat Fluid Pressure Regulator

Prodigy HDLV Pump Manifold and Circuit Board

Air Spray Proportioning Valve

Solenoid Valve Installation Kit

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Series 3900/M Pump Retrofit Kit

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Tools you will need: Screwdrivers, Metric Sockets, Hook and Loop Tape or Zip Ties, Shop Light, Wire cutters, Wire crimping tool

Nordson/Drexelbrook Material Level Control Kit

TPM/GMT Panel Installation Guide

In order to receive proper credit for returned units and

S1024-2POS / S POS S2024-2POS / S POS

INSTALLATION. **Microprocessor Status LED:

CHEVORLET IMPALA

Installation Manual. Frameworx Tel-E-Foul. September 2017 /

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

PowerAir Compressor Installation

TCU Static Mixer Installation

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

Safety and General Information

Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK

BXD Battery Disconnect

ClassicSeries Compressor Installation

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

Electrical Installation

For reference, there is a photograph of a completed upgrade on the last page of this document, refer also to drawing that is attached.

Installation Instructions

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Transcription:

Instruction Sheet P/N 1102354-02 CoolWave 2 Transformer T3 and Wire Harness Upgrade Kit Use the transformer and harness kit to upgrade or replace the Coolwave 2 transformer. NOTE: Retain the box used for shipping the T3 transformer and wiring to comply with the conditions of warranty. WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. A qualified and competent electrician must carry out all electrical maintenance and servicing of this equipment. WARNING: This equipment operates at high voltages up to 5000 volts dc and is therefore potentially dangerous. The electrician servicing this equipment must take all precautions. WARNING: Isolate the equipment at the main disconnect or lockout before removing any of the cover panels. T3 Transformer Versions See Figure 1. Previous versions of the T3 transformer could have either pigtail wires or Faston terminals. NOTE: If transformer has Faston terminals, procedures for replacing wires is not necessary. Transformer with Pigtail Wires Transformer with Faston Terminals Faston Terminal Figure 1 Old Versions of thetransformer

2 Coolwave 2 T3 Transformer and Wire Harness Upgrade Kit New Wiring Harness NOTE: Wire harness is only required for replacing transformers with pigtail wires. Ground Wire Secondary Wires Primary Terminals Figure 2 New Wiring Harness Upgrading the Transformer Removing Power Supply Cover 1. Remove electrical power from unit. 2. See Figure 3. Remove the six M5 screws from the power supply cover. Remove the cover and set it aside. Figure 3 Remove Cover Screws

Coolwave 2 T3 Transformer and Wire Harness Upgrade Kit 3 Removing the Old Transformer Wires NOTE: Removing the Old Transformer Wires is not required when replacing transformers with Faston terminals. Tools Required: Wire cutter and stripper Faston crimp tool Extraction tool (refer to Parts section) 1. See Figure 4. Cut wires about 0.25 from the transformer winding. Cut both red secondary wires and remove from harness. 2. Cut both black primary wires, but DO NOT remove. These wires are used for the new transformer. Red Secondary Wires Black Primary Wires Figure 4 Cutting Old Transformer Wires

4 Coolwave 2 T3 Transformer and Wire Harness Upgrade Kit 3. Remove connector CONN6 located on the main control board then the red wires at positions 1 and 7. Refer to Transformer and Harness Disposal for instructions on proper disposal. CONN6 CONN6 Position 1 Position 7 Wire Removed from Position 7 Figure 5 Removing CONN6 and Using Extractor Tool to Disconnect Red Transformer Wires Figure 6 Using Extractor Tool to Remove Wires and Terminals from Connector

Coolwave 2 T3 Transformer and Wire Harness Upgrade Kit 5 Replacing Transformer See Figure 7. 1. Faston terminals only: Remove harness connections from Faston terminals. 2. Remove the four transformer mounting screws and washers. Keep hardware for installing new transformer. 3. Remove transformer and refer to Transformer and Harness Disposal for instructions on proper disposal. 4. Mount and secure the new transformer to the chassis using the four screws and washers removed in prior steps. Faston Terminals Mounting Screws and Washers Figure 7 New Transformer

6 Coolwave 2 T3 Transformer and Wire Harness Upgrade Kit Installing the New Wire Harness NOTE: Installing the New Wire Harness is only required when replacing old transformer with pigtail wires. 1. See Figure 8. One at a time, matching the wire label to the transformer label, attach the Faston lugs onto the terminals, and insert the wires into the main control board CONN6. From Transformer T3 Wire Color and Label To X1 Black, X1 H Main Control Bd CONN6 1 X2 White, X2 N Main Control Bd CONN6 7 X3 Green/Yellow X3 GND Transformer, Mounting Screw Wire Color and Label Black, CON6 1 White, CON6 7 Green/Yellow, #10 Ring Terminal Secondary Faston Terminals Ground Screw Location SEC: 500VA NORDSON XXXXXXX Primary Faston Terminals Figure 8 New Transformer Terminals 2. Strip wire insulation back 0.30 in. on the existing primary black wires then crimp on the supplied 0.25 in. Faston lugs. One at a time, match the wire label to the transformer label, and attach the Faston lugs to the terminals. From Transformer T3 Wire Color To Wire Color H4 Black Fuse Block 2-1 Black H1 Black Fuse Block 2-2 Black

Coolwave 2 T3 Transformer and Wire Harness Upgrade Kit 7 Transformer and Harness Disposal Dispose of equipment and materials used in operation and servicing according to local codes. Returns under Warranty When returning a transformer or wire harness that is under warranty, the items must be sent with the original packaging in which it was received. Failure to comply with these instructions will void the warranty. Send return items to: UV System Group Nordson Corporation Warranty Division 444 Gordon Ave. Amherst, Ohio, 44001 Parts To order parts, call the Nordson Finishing Customer Support Center at (800) 433 9319 or contact your Nordson representative. Replacement Kit Part Description Note 1612545 KIT, T3 transformer, step down, CW2 A NOTE A: Kit includes transformer and harness. Extractor Tool (Optional) Part Description Note 1102411 TOOL, extraction, pin, mini-fit

8 Coolwave 2 T3 Transformer and Wire Harness Upgrade Kit Issued 4/18 Original copyright date 2010. CoolWave, Nordson, and the Nordson logo are registered trademarks of Nordson Corporation.