Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Similar documents
Return Line Filter RF

Inline Filter RFL. Cast version Volume rates up to 1300 l/min* Pressure range 25/40 bar

Inline Filter RFLD. Change-Over. Cast Version Flow Rates up to 1300 l/min* Pressure Range 25/40/64 bar With Ball Change-Over Valve E /01.

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Return Line Filter RF

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Change-Over Pressure Filter DFDK

Return Line Filter RFM with 4-Hole Mounting

Change-Over Inline Filter RFLD Welded Version

Pressure Filter DF...K P, DF...M P, Flange Mounted

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Change-Over Inline Filter RFLD Weld Version

Return Line Filter RFM with 4-Hole Mounting

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

Change-Over Inline Filter AFLD to API 614

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Suction Filter SF/SFM/SFF and Suction Filter Elements S and S..

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

Series RFLD Duplex In-Line Filter

Return line and Suction Boost Filter RKM

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Series RFL In-Line Filter

MultiRheo Filter MRF 1/2/3/4/5/6/7

Return Line Filter RFM with 2-Hole Mounting

MultiRheo Filter MRF 1/2/3/4/5/6/7

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

HIGH PRESSURE FILTERS DF/DFF 1500 Series Inline Filters 6090 psi up to 250 gpm

HYDRAULIC AND LUBE OIL FILTERS RFM Series

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

Low Pressure Filters

HIGH PRESSURE FILTERS

MEDIUM PRESSURE FILTERS

Low Pressure Filters

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

HIGH PRESSURE FILTERS

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

Stainless Steel Pressure Filters

Process Inline Filter Medium / High Pressure PFM / PFH

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

HIGH PRESSURE FILTERS

NFH Low Pressure Filters

HIGH PRESSURE FILTERS

FILTER ELEMENTS. Overview of Elements PN# / / FIL

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

High-pressure inline filter, flangeable

D e s c r i p t i o n

Spare Parts List Filter NFD Change-Over Version

Spare Parts List Return line filter RF

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

Low Pressure Filters

Process Multi-Rheo Filter PMRF

Duplex Pressure Filters

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

LowViscosity Housing Filter LVH-F

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Block mounting filter, lateral flange-mounting possible

Spare Parts List Return Line Filter RFM with 4-hole attachment

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

LMP series

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

HIGH PRESSURE FILTERS Series HF2P

Flow rates to 500 l/min

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

Innovative Element Technology for installation in HYDAC filters E / Quick Selection -

Process screen basket filter PRFS

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

Plastic Tank Systems Standard models

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

Breathers and Filler Breathers

SPIN-ON FILTERS & ELEMENTS

Spare parts list Inline filter FLND switchable

Suction Filters S8-455 SE56-560

NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

Stainless Steel Pressure Filters Housings, Elements, Indicators & Sizing

SPIN-ON FILTER - LOW PRESSURE LINE

Line filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

Be sure to order the correct number of elements: OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

In line high pressure filters. HF 725 series

Inline filter with filter element according to DIN 24550

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

Series TSW Sheet No J. SUCTION FILTER, horizontal tank mounted. Dimensions: mounting surface

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

Inline filter with filter element according to DIN 24550

In line high pressure filters. HF 735 series

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

Block mounting filter, for lateral flange-mounting

Automatic back-flushing filter AutoFilt RF4

Feed Pumps VP / VPB / VPBM

Block mounting filter, for lateral flange-mounting

Transcription:

NF filters are designed for inline mounting and as tank-top mounted return line filters. These filters can also be used on filling, flushing and off-line units. Inline Filters NF Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

1. TECHNICAL DESCRIPTION 1.1. FILTER HOUSING Construction The filter consists of a filter housing and an easily removable cover plate with central thread. 1.2. FILTER ELEMENTS Hydac filter elements fulfil all ISO test criteria. Reliable filter operation is only guaranteed for original Hydac filter elements. The filter elements are also suitable for dynamic conditions due to their high pressure stability; max permissible p across the element: Betamicron (BN3HC) : 25 bar Paper (P/HC) : 10 bar Wire mesh (W/HC) : 30 bar Stainless steel fibre (V) : 30 bar Betamicron /Aquamicron (BN/AM) : 10 bar Aquamicron (AM) : 10 bar Fluid compatibility Suitable for mineral oils, lubrication oils, non-flam fluids, synthetic and rapidly biodegradable fluids. For use with water, please contact our sales/ technical department. For further details on filter elements, please see brochure, no.: E 7.200../.. 1.3. CLOGGING INDICATORS Type of indicator VR return line indicator (only in version 1.0) VM differential pressure indicator (only in version 2.0 and 3.0) Pressure setting 2 2 bar 5 5 bar Indicator type code B. = visual C. = electrical D. = visual/electrical Modification number 0 = the latest version is always supplied Supplementary details -V Viton -Lxx voltage details for type "D" Please note: The must not be screwed into the cover plate. For further details on s, please see brochure, no. E 7.050../.. 1.4. SEALS Perbunan (= NBR) or Viton (= FPM for HFD oils). 1.5. SPECIAL MODELS AND ACCESSORIES Mounting bracket for size 1310/2610 1.6. SPARE PARTS Please see Spare Parts and Maintenance Instructions brochure. VR 2 D. 0 / -L220 2. GENERAL Mounting Tank-top mounted return line filter or inline filter Temperature range -10 C to +100 C Pressure setting of the differential pressure clogging indicator p a = 2 bar -10 % Other pressure settings on request! Opening pressure of the bypass valve p o = 3 bar +0.5 bar optionally 6 bar Other opening pressures on request! 2

3. MODEL CODE (also order example) 3.1. COMPLETE FILTER Filter type Filter material of element BN/HC Betamicron (BN3HC) AM Aquamicron BN/AM Betamicron /Aquamicron P/HC Paper W/HC Stainless steel wire mesh V Stainless steel fibre Housing material / Al/Al-GGG 1310, 1350, 2610, 2650, 5210, 7810, 10410 Operating pressure D = 25 bar Type and size of port NF BN/HC 2610 D P 10 D 1. X /-L24 Type Port Filter size 1310 1350 2610 2650 5210 7810 10410 L SAE DN 50 M SAE DN 65 N SAE DN 80 P SAE DN 100 Filtration rating in µm BN3HC, V : 3, 5, 10, 20 BN/AM : 3, 10 P/HC : 10, 20 W/HC : 25, 50, 100, 200 AM : 40 Type of A without, with blanking plug B with visual (only for tank-top mounted return line filters) BM with visual, manual re-set (all types) C with electrical D with visual and electrical LE visual-mechanical/electrical with 100% switching contact LZ visual-mechanical/electrical with 75% and 100% switching contact Type code 1 Tank-top return line filter return line indicator inlet flange horizontal at top, outlet vertical from size 5210 horizontal tank seal supplied 2 Inline filter differential pressure indicator inlet flange horizontal at bottom, outlet vertical, from size 5210, horizontal only for size 1350/2650: differential pressure indicator inlet and outlet horizontal and opposite 3 Inline filter differential pressure indicator inlet flange horizontal at top, outlet vertical Type code Filter size 1310 1350 2610 2650 5210 7810 10410 1 2 3 for other clogging indicators see brochure no. E 7.050../.. Modification number X the latest version is always supplied Supplementary details V FPM (Viton) seals, filter suitable for rapidly biodegradable oils and phosphate esters (HFD-R) L... light with appropriate voltage (24V, 48V, 110V, 220V) only on type LED 2 light emitting diodes up to 24 volt KB without bypass valve D indicators B6 opening pressure of the bypass valve 6 bar SB4 filling line with Ø 4 mm orifice EM manual vent with shut-off valve EP permanent vent via Minimess hose 3

3.2. REPLACEMENT ELEMENT (also order example) 1300, 2600 Type R Filtration rating in µm BN3HC, V : 3, 5, 10, 20 BN/AM : 3, 10 P/HC : 10, 20 W/HC : 25, 50, 100, 200 AM : 40 Filter material BN3HC; V; BN/AM; P/HC; W/HC; AM Supplementary details V = FPM (Viton) seals, filter suitable for rapidly biodegradable oils and phosphate esters (HFD-R) W = filter suitable for oil-water emulsions (HFA, HFC), NBR seals KB = without bypass valve B6 = opening pressure of the bypass valve 6 bar 1300 R 010 BN3HC /-KB 5. FILTER CALCULATION / SIZING The total pressure drop of a filter at a certain flow rate is the sum of the housing p and element p. The pressure drop can be determined either with the aid of our Filter Sizing Program, which is available free of charge, or by using the following graphs. It must be stressed that all of the technical documentation from HYDAC Filtertechnik always states the pressure drop of the complete filter. 5.1. P-Q HOUSING GRAPHS TO ISO 3968 The housing graphs apply to mineral oil with a density of 0.86 kg/dm³ and a viscosity of 30 mm²/s. In this case, the differential pressure changes proportionally to the density. 4. FILTER SPECIFICATIONS Filter type Port Element size Number Weight (kg) of elements with element 1310 SAE DN 100 1300 R... 1 21 1350 SAE DN 50 SAE DN 65 SAE DN 80 1300 R... 1 18 SAE DN 100 2610 SAE DN 100 2600 R... 1 30 SAE DN 50 2650 SAE DN 65 SAE DN 80 2600 R... 1 25 SAE DN 100 5210 SAE DN 100 2600 R... 2 104 7810 SAE DN 100 2600 R... 3 146 10410 SAE DN 100 2600 R... 4 198 NF 1310/2610...1.0/2.0/3.0 NF 1350/2650...2.0 NF 5210...2.0 NF 7810...2.0 Q in l/min Q in l/min NF 10410...2.0 Q in l/min Q in l/min 4

5.2. P-Q GRAPHS FILTER ELEMENTS The element graphs apply to mineral oil with a kinematic viscosity of 30 mm²/s. The pressure drop changes proportionally to the change in viscosity (see Example 5.3.). 1,4 1.4 1,2 1.2 1 0,8 0.8 0,6 0.6 0,4 0.4 0,2 0.2 0 1 0.9 0,9 BN3HC 0 200 400 600 800 1000 1200 1400 1600 1800 2000 V BG 1300 BG 2600 BG 1300 BG 2600 flow rate in l/min 3µm 5µm 10µm 3µm 20µm 5µm 10µm 20µm 3µm 5.3. EXAMPLE General viscosity (mm²/s) p total = p housing + p element x 30 mm²/s p housing = to be determined in accordance with Point 5.1. p element = element pressure drop at flow rate Q/n and viscosity = 30 mm²/s determined according to Point 5.2. n = no. of elements in accordance with Point 4 Filtration specifications Example System parameters: NF 5210 with BN3HC element (10 µm) Viscosity = 68 mm²/s (ISO VG 68 at 40 C); Q = 1400 l/min; n = 2 Q = 1400 = 700 l/min n 2 p housing = 0.10 bar (at Q) p element = 0.15 (at Q/n) p total = 0.10 bar + 0.15 x 68 mm²/s = 0.44 bar 30 mm²/s For ease of calculation, our Filter Sizing Program can be downloaded from our website www.hydac.com. 0.8 0,8 5µm 0.7 0,7 0.6 0,6 0.5 0,5 0.4 0,4 0.3 0,3 0.2 0,2 10µm 3µm 5µm 20µm 10µm 20µm 0.1 0,1 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 flow rate in l/min W/HC 0.1 0,1 1300 0.09 0,09 0.08 0,08 0.07 0,07 0.06 0,06 0.05 0,05 0.04 0,04 0.03 0,03 2600 0.02 0,02 0.01 0,01 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 P/HC flow rate in l/min 0.16 0,16 1300 10µm 0.14 0,14 0.12 0,12 0.1 0,1 0.08 0,08 0.06 0,06 1300 20µm 2600 10µm 0.04 0,04 2600 20µm 0.02 0,02 0 0 500 1000 1500 2000 flow rate in l/min 5

6. DIMENSIONS 6.1. NF 1310/2610...1.0 vent G 1/2 inlet filling connection G 3/4 connection for outlet min. max. 6

6.2. NF 1310/2610...2.0 vent G 1/2 inlet filling connection G 3/4 drain contaminated side G 1/2 outlet connection for View from below 7

6.3. NF 1310/2610...3.0 vent G 1/2 inlet filling connection G 3/4 connection for outlet drain contaminated side G 1/2 8

6.4. NF 1350 connection for differential drain contaminated side G 3/4 inlet outlet Port A B ØC M SAE DN 50 / 2" 77.8 42.9 50 M 12x15 SAE DN 65 / 2 ½" 88.9 50.8 65 M 12x15 SAE DN 80 / 3" 106.4 62.9 75 M 16x24 SAE DN 100 / 4" 130.2 77.8 100 M 16 9

6.5. NF 2650 connection for differential drain contaminated side G 3/4 inlet outlet Port A B ØC M SAE DN 50 / 2" 77.8 42.9 50 M 12x15 SAE DN 65 / 2 ½" 88.9 50.8 65 M 12x15 SAE DN 80 / 3" 106.4 62.9 75 M 16x24 SAE DN 100 / 4" 130.2 77.8 100 M 16 10

6.6. NF 5210...1.0 connection for vent G 1/2 11

6.7. NF 5210...2.0 vent G 1/2 drain G 1/2 connection for 12

6.8. NF 7810...2.0 vent G 1/2 drain G 1/2 connection for 13

6.9. NF 10410...2.0 vent G 1/2 drain G 1/2 connection for 7. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. 14

NOTES: 15