DeVilbiss igo Transportable Oxygen Concentrator.

Similar documents
USER MANUAL READ THIS MANUAL BEFORE OPERATING THIS DEVICE. SAVE THIS MANUAL FOR FUTURE REFERENCE. DEALER: THIS MANUAL MUST BE GIVEN TO THE END USER.

Eclipse 3 with autosat

user manual A OxyGoFit-User-Manual-English-Only-Without-FAA-Without-CE.indb 1 9/12/ :44:04 AM

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

Chapter 1 1 Intended Use, Contraindications and General Precautions

user manual 1 User Manual OxyGo HF, English Only, Yellow LED.indb 1 5/17/2016 9:35:36 AM

SECTION 8 TROUBLESHOOTING GUIDE

BRAVER UPS. (Uninterruptible Power System) User s Manual

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

MP V 8A Electronic Smart Charger. Instruction and Information Manual

60V RECHARGEABLE LITHIUM-ION BATTERY

Chapter 1 1 Intended Use, Contraindications and General Precautions

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Chapter 1 1 Intended Use, Contraindications and General Precautions

Eclipse TM with autosat. Personal Ambulatory Oxygen System (PAOS) TM. User Manual

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

6 Bay Battery Charger Operation Manual

G2 Portable oxygen concentrator User Manual

Chapter 1 1 Intended Use, Contraindications and General Precautions

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Jumpbox Model SP-12V1500-JB1

4L PROVIDER MATERIALS

MULTI FUNCTION POWER PAK PLUS

PSJ-2212, PSJ-3612, PSJ-4424

Model: SE-4020-CA Automatic Battery Charger

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE

User Manual. equinox TM. Model 4000

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

SP6. Automatic Battery Charger. Model

CADD-Solis Infusion Pump

GSL Electronics Modified Sine Wave Power Inverters

MULTI-FUNCTION JUMP STARTER

Matson Jump Starter Operator s Manual

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Model: SL360R Lithium Ion 360 LED Cordless Work Light

JUMP STARTER OPERATOR S MANUAL RA1900

20V Lithium-Ion Battery Pack

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

4. TECHNICAL SPECIFICATIONS

Guidelines for Handling Lithium Batteries

By Inova Labs QUICK START GUIDE. For Use With Model: XYC100B-P4L

56V BATTERY 2.0AH/2.5AH/4.0AH/6.0AH MODEL NUMBER BA1120E/BA1400/BA2240E/BA3360 CHARGE BEFORE FIRST USE

400 Watt Backup Power System Owner s Manual

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

USER M A N U A L P O R T A B L E O X Y G E N C O N C E N T R A T O R

IMPORTANT SAFETY INSTRUCTIONS

Technical Support. Manufactured and Distributed by Inova Labs Comsouth Drive, Suite 100, Austin, TX USA Corporate Office

OWNERS MANUAL. Charging Batteries Up-right type - Li-ion

Eclipse TM with autosat. Personal Ambulatory Oxygen System (PAOS) TM. User Manual

Cordless Rechargeable Saw Instructions for Use

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

USER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M

Eclipse 5 TM with autosat. Eclipse Oxygen System. User Manual

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

Quick Start Guide. Manufactured & Distributed by

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

MULTI-FUNCTION JUMP STARTER

Battery Powered Hydraulic Pump; Kit PN [ ]

INSTRUCTION MANUAL. Kids Ride-On Dirt Bike with Training Wheels SKY SKY3487. Ver. 2

Car Battery Charger Instructions for Use

INSTRUCTION MANUAL. Kids Ride-On Motorcycle SKY Ver. 3

Instruction Manual MODEL: AC TRACKTECH T Rev. C. World s First Portable, Remote-Control Aircraft Tugs

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Installation Operation Parts

PLEASE READ THESE INSTRUCTIONS BEFORE USE

110W CARAVAN SOLAR PANEL KIT PLU

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

STEP-BY-STEP INSTALLATION GUIDE

Know your energy display. See where you could save energy and money

- Optional Audio warning when discharge test is complete or tester malfunction.

INSTRUCTION MANUAL. 12V Ride on ATV Quad SKY SKY SKY3754. Ver. 4

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

User s Manual. Automatic Switch-Mode Battery Charger

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

44,400mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

IMPORTANT SAFETY INSTRUCTIONS

EDITION : A. Description: SCALE : 100% (L4 FFL-201 ANZ) manual artwork PART NO COLOR ITEM ID. MATERIAL 50gsm recycle paper REV.

INSTRUCTION MANUAL. Maserati Alfieri Ride-On SKY SKY4735. Ver. 1

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

AUTO CHARGE D PUMP PLUS

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Battery charger , A, B

MULTI-FUNCTION POWER PACK

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Technical Support

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 900

R06 JH 03/19/13 EN-INTL SimplyGo USER MANUAL

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

Battery Unit BHM60PC/BHM100PC Instruction Manual

OPERATOR S MANUAL. Portable Power 950. Model No

Transcription:

DeVilbiss igo Transportable Oxygen Concentrator. Equipment Guide. BOC: Living Healthcare

Transportable Oxygen Concentrator. Equipment Guide. 03 Contents. 4 Important Parts 6 Control Panel 7 How to use the igo 9 Do s and Don ts 10 Power failure/concentrator breakdown Electricity refunds 12 Troubleshooting

04 Transportable Oxygen Concentrator. Equipment Guide. Important Parts. The igo concentrator works by drawing in air and separating the oxygen from the other gases using a filter system. Oxygen is then delivered to you by tubing which connects to the cannula or facemask for you to breathe. The igo transportable concentrator is small and lightweight, yet capable of delivering up to 3 LPM of constant flow oxygen. An ideal choice for travelling, the igo can be operated from a standard 12 V car charger socket or from its lithium ion battery which will give the user up to 5.4 hours of usage.

Transportable Oxygen Concentrator. Equipment Guide. 05 Power Button Press and hold the Power On/Off Button to turn your unit on or off Control Panel Refer to igo Control Panel below Oxygen Outlet oxygen is dispersed through this port Power Input Connect either AC or DC power Handle Exhaust Vents (on each side) Air Filter Handle Cart Connection Battery Latch Rechargeable Battery Battery Tabs Rating Label (on bottom) Battery Bay Communication Port This port allows service personnel to diagnose and monitor igo performance. It is not for patient use. Battery Contacts Slot in Battery Bay

06 Transportable Oxygen Concentrator. Equipment Guide. Control Panel. 4b 1 2 3 4a 4c 5a 6a 5b 6b 7 8 1 Oxygen Outlet oxygen is dispersed through this port. 2 Power button turns the system ON or OFF. 3 No Breath Detected light (PulseDose mode ONLY) illuminates intermittently and an audible alert sounds every 3 seconds if the igo is operating in PulseDose mode and does not detect a breath for 30 seconds. If a breath is detected during the alert, the alert condition is cleared. If a breath is not detected during the alert, the unit changes to continuous flow mode after 60 seconds of alerting. NOTE Once the unit changes to continuous flow, use the Mode Select button to change back to PulseDose. 4a External Power light illuminates when the igo system is connected to either AC or external DC power. Power Fail alert illuminates inter mittently with an audible alert for 15 minutes. Pressing the Power button stops the alert. 4b Green Normal Oxygen light illuminates when the igo delivers greater than 84% oxygen purity. 4c Yellow Low Oxygen light illuminates if the igo delivers 75 % to 84 % oxygen purity. 5a Red Service Required light illuminates with an audible alert if the igo delivers less than 75 % oxygen purity or if component failure is detected. 5b Mode Select button selects the mode of oxygen delivery (PulseDose or continuous flow). 6a Flow Indicator light in PulseDose mode, pulses ON with every breath; in continuous flow mode, illuminates continuously. 6b Flow Rate Indicator lights illuminate the flow rate at which the igo is set to deliver oxygen.

Transportable Oxygen Concentrator. Equipment Guide. 07 7 Flow Rate Control buttons increase or decrease the flow rates in PulseDose (1 to 6 LPM) or continuous flow (1 to 3 LPM) as ordered by the physician. 8 Battery Charge lights indicate the battery pack s charge status. When the battery is fully charged, all six lights illuminate. As the battery discharges, the lights turn off one by one. Each illuminated light indicates approximately 45 minutes of battery charge at 2 LPM in PulseDose mode. When the battery is charging, the lights illuminate in a cycle pattern. When the battery has approximately 10 % of capacity, a yellow battery light illuminates with a single audible alert. When the battery is depleted, the unit enters Power Fail alert. Power Fail alert illuminates intermittently with an audible alert for 15 minutes. Pressing the Power button stops the alert. How to use the igo. IMPORTANT: Please ensure you read all accompanying literature supplied prior to using your home oxygen equipment. In particular, pay attention to the section on not smoking or allowing others to smoke near your equipment. 1. Please follow all operating instructions. 2. Place your igo in a suitable location. 3. Ensure that the air filter is installed in the handle cavity. 4. Select Power Source: AC Operation Plug cord into igo and wall outlet. DC Operation Plug cord into igo. START CAR BEFORE INSERTING CORD INTO DC ACCESSORY POWER PORT. Rechargeable Battery Insert the battery tabs into the slots in the Battery Bay and push the battery into the igo unit until it is secure and flush with the back of the unit. NOTE: Rechargeable Battery must be charged before first use. To completely charge the battery, connect the AC Power Cord and plug in. This may require up to 4.5 hours of uninterrupted charging. The battery will not charge when connected to a DC Power Port.

08 Transportable Oxygen Concentrator. Equipment Guide. Typical Battery Operation Time Flow Rate Continuous Flow 1.0 4.0 hours 2.0 2.4 hours 3.0 1.6 hours 4.0 5.0 6.0 5. Connect the tubing to the oxygen outlet and cannula. 6. Press and hold the Power Button to turn your igo On. 7. Your igo is now ready for use. Attach a standard nasal cannula to your nose and face. Breathe normally through the cannula. 8. Select Delivery Mode Press the Mode Select button. The igo will come on at the last mode and flow setting used. Rechargable Battery. a. Continuous Flow a continuous supply of oxygen will flow through your tubing and nasal cannula. b. PulseDose a pulse of oxygen is released with each breath. 9. Check the Flow Rate use the Flow Rate Setting buttons to adjust the flow rate to the setting prescribed by your clinician. NOTE: BOC may have set the flow so that it cannot be adjusted. 10. When you have finished using the igo, press and hold the Power Button to turn Off. Store the igo in a cool, dry location when not in use. Do s and Don ts. Keep the igo at least 5 feet (1.6 m) from hot, sparking objects or naked sources of flame. The igo should be located so as to avoid pollutants or fumes. Do not use oil or grease: A spontaneous and violent ignition may occur if oil, grease, or other petroleum substances come into contact with oxygen under pressure. Keep these substances away from the oxygen system, tubing and connections, and any other oxygen source. Do not use any petroleum based or other lubricants.

Transportable Oxygen Concentrator. Equipment Guide. 09 Do not allow unauthorised or untrained individuals to service the equipment or open the device. Do not operate the igo or accessories in standing water and do not submerse or expose to water. Electric shock or damage to the unit may result if this occurs. Protect the Battery and Power Adapters from fluid spills or drips to avoid possible shock hazards. Do not expose the Rechargeable Battery to fire or dispose of in a fire. It may explode and cause potential injury. Do not short circuit the battery s metal contacts with metallic objects such as keys, paperclips, or coins. It may cause sparks or excessive heat. Do not disassemble, puncture, or crush the battery. Rechargeable Battery electrolytes may be toxic if swallowed and can be harmful to skin and eyes. Use of a damaged battery may cause personal injury. Keep the battery away from children. This device contains electrical and/or electronic equipment. Please do not dispose of any of these components. Electric shock hazard do not attempt to repair or service this item. Do not operate the igo in an area where the air may be contaminated with carbon monoxide or hydrocarbons as this may shorten the life of the unit (i. e. near car exhausts, furnaces, or gas heaters). Do not place this device near other equipment or devices that create or attract electromagnetic fields. Placing the unit in electromagnetic fields greater than 10 V/m can affect its operation. Examples of such equipment are defibrillators, diathermy equipment, cellular telephones, CB radios, radiocontrolled toys, microwave ovens, etc. Use only the AC Adapter and DC Adapter supplied with the igo. Do not use replacement parts, accessories, or adapters other than those authorised by BOC. Do not expose the igo, Rechargeable Battery, or accessories to temperatures outside of specified operating or storage temperatures as this may cause damage. The operating temperature for the igo is between 5 C 40 C. Always use the igo in a vertical position. Never block the air intake and air exhausts on the igo. Do not cover with clothing or any other material, or use whilst in a bag other than the one provided. Always ensure you organise access to a power source to recharge your igo when required. The igo should not be stored in a car over night at any time of the year (this is related to temperature range). If you wish to take the igo on holiday, this must be discussed in advance with BOC Healthcare and your clinician.

10 Transportable Oxygen Concentrators. Equipment Guide. Power failure/concentrator breakdown. What to do if your oxygen concentrator breaks down or you have a power failure. Switch to your back-up cylinder and call the Patient Service Centre on 0800 136 603 and explain what the problem is. They will ask you a series of questions to determine what the problem might be. It is crucial that you give them as much help as you can. They will then give you advice on how to fix the problem or if this is not possible, they will arrange for one of our PSRs to visit you. Our free phone line 0800 136 603 is open 24 hours a day every day of the year to respond to emergencies. If you feel unwell then it is important that you contact your doctor so that he/she can provide guidance. Back-up cylinders These cylinders are normally provided for use in case of power failure or breakdown of the concentrator. Electricity refunds. What is an electricity refund? As part of our service we will refund the cost of electricity used by the oxygen concentrator on a quarterly basis. After you have been using the oxygen concentrator for approximately 3 months, a BOC Patient Service Representative (PSR) will ring you to advise that a service is due on the equipment. It is important that you are available for this visit as the PSR will take the first readingof the concentrator hours meter. The meter reading will be entered into the BOC computer system. This will

Transportable Oxygen Concentrators. Equipment Guide. 11 issue a refund paid by bank transfer (BACS), directly into your account. It is essential that you confirm to us your electricity provider to allowus to calculate the correct level of reimbursement. We will reimburse at the lowest available tariff in your region, unless we have your electricity provider details. If you have not yet given us this information, please ring our Patient Service Centre on 0800 136 603. How do we calculate the estimated refund? The computer is able to estimate the hours the concentrator has been used based on the readings taken at installation and also at the first service. If your oxygen usage has changed and you have been over or underpaid then we will rectify this at the next refund. The service visit It is very important your concentrator is first serviced after 3 months and then every 6 months after so that we can ensure it is in full working order. During these visits we can also check that you have enough cannulae/masks. Month 1 Install Month 3 Service by PSR resulting in refund The ongoing process Future concentrator service visits will be plannedat six monthly intervals when a meter reading willbe taken by our PSR and a refund will be issued. In between these visits we will arrange to send you an estimated refund. Therefore 3 months after the concentrator service visit you will receive a further refund which is based on an estimate calculated by our computer system. Month 6 Estimated payment based on previous actual usage Month 9 Service by PSR resulting in refund Month 12 Estimated refund based on previous actual usage

12 Transportable Oxygen Concentrators. Equipment Guide. Troubleshooting. The following troubleshooting chart will help you analyse and correct minor igo malfunctions. If the suggested procedures do not help, please call BOC on 0800 136 603. Do not attempt any other maintenance at this time. Symptom Possible cause Solution Unit not operating. No lights illuminated 1. Power button was not held. 1. Press Power button and hold for one second. and nothing happening when 2. No external power and no charged 2. Plug into external power or install charged battery. power button pressed. battery installed. 3. Unit malfunction. 3. If the above solutions do not work, contact BOC on 0800 136 603. Unit not operating. External Power light flashing with audible alert. Power Fail alert activated. Cannot change the flow rate. 1. AC power cord not properly inserted into wall outlet or DC adapter not attached. 2. Charged battery not installed or defective battery. 3. No power at wall outlet. 1. Check power cord connection at the wall outlet and adapter connection to igo. 2. Install charged battery or contact your provider for a replacement battery. 3. Check the home circuit breaker and reset if necessary. Use a different wall outlet if the situation occurs again. 4. Faulty AC Adapter. 4. Contact BOC on 0800 136 603. 5. Faulty DC accessory 5. Check the fuse. power port outlet. 6. Faulty DC Adapter. 6. Contact BOC on 0800 136 603. If the above solutions do not work, contact BOC on 0800 136 603. 1. Flow rate is locked. 1. Unlock flow rate. 2. Unit malfunction. 2. Contact BOC on 0800 136 603.

Transportable Oxygen Concentrators. Equipment Guide. 13 Symptom Possible cause Solution Unit set for PulseDose mode: No Breath Detected light flashing and audible alert sounding. OR Unit changed to Continuous Flow automatically. Oxygen level out of specification. Yellow Low Oxygen light illuminating. OR Red Service Required illuminating and audible alert sounding. External Power and/or Battery Power lights illuminating. Unit is operating. 1. Cannula is not adjusted properly. 2. Obstructed cannula or oxygen tubing. 1. Check all cannula connections to make sure they are tight and adjust the cannula to fit comfortably. Ensure tubing is not kinked. 2. Detach cannula. If proper flow is restored, clean or replace if necessary. Disconnect the oxygen tubing at the oxygen outlet. If proper flow is restored, check oxygen tubing for obstructions or kinks. Replace if necessary. 3. Replace with shorter tubing/cannula. 3. Tubing/cannula too long. 4. Humidifier attached. 4. Remove humidifier. (PulseDose does not operate with humidifier). 5. Low flow cannula 5. Replace with standard cannula. being used. Intake silencer/filter is blocked. If the above solutions do not work, contact BOC on 0800 136 603. Contact BOC on 0800 136 603. 1. Air filter is blocked. 1. Check the air filter. If the filter is dirty, wash it following the cleaning instructions. 2. Exhaust is blocked. 2. Check the exhaust area; make sure there is nothing restricting the unit exhaust. 3. Intake silencer/filter 3. Contact BOC on 0800 136 603. is blocked. If the above solutions do not work, contact BOC on 0800 136 603.

14 Transportable Oxygen Concentrators. Equipment Guide. Symptom Possible cause Solution Red Service Required light illuminating. External Power and/ or Battery Power lights illuminating. Audible alert sounding. Unit not operating. Power Fail alert activated: External Power light flashing and audible alert sounding. Red Service Required light flashing. Flow Indicator light flashing. Audible alert sounding. Unit operating. Unit not operating when used with charged battery. Power Fail alert activated: External Power light flashing and audible alert sounding. 1. Air filter is blocked. 1. Check the air filter. If the filter is dirty, wash it following the cleaning instructions. 2. Exhaust is blocked. 2. Check the exhaust area; make sure there is nothing restricting the unit exhaust. 3. Unit is overheated. 3a. Allow unit to cool and try again. 3b. Move unit to cooler location. 4. Intake silencer/filter 4. Contact BOC on 0800 136 603. is blocked. If the above solutions do not work, contact BOC on 0800 136 603. 1. Battery completely 1. Recharge battery. discharged. 2. Lost external power without battery installed. Blocked or defective cannula or oxygen tubing. Battery is overheating. 2. Install battery or plug into external power. a. Detach cannula. If proper flow is restored, clean cannula or replace if necessary. b. Disconnect the oxygen tubing at the oxygen outlet. If proper flow is restored, check oxygen tubing for obstructions or kinks. Replace if necessary. Allow battery to cool.

Transportable Oxygen Concentrators. Equipment Guide. 15 Symptom Possible cause Solution DC Adapter attached. Unit operating from battery or not operating. External Power light is not illuminated. Audible alert sounds intermittently when operating from DC Adapter. Lowest Battery Status light is Yellow. Unit beeps once. Battery Status lights never indicate fully charged. Yellow Battery Status light flashing. 1. Poor connection to DC power source. 2. Vehicle power source (vehicle accessory connector) dropped too low for the DC Adapter. 3. Fuse in vehicle is blown. 1. Vehicle not running. 1. Start vehicle. 2. Poor connection to DC power source. 3. Vehicle electrical system overloaded or defective. Battery needs to be charged. 1. Ensure the DC accessory power port outlet is clean and a good connection can be made. Insert the DC Adapter into the vehicle s DC accessory power port outlet. 2. If the vehicle power source drops too low for the DC Adapter, the igo will revert to battery operation (if present) or will cease operation until power is restored. 3. Check the fuse and replace if necessary. 2. Ensure the DC accessory power port outlet is clean and a good connection can be made. Insert the DC Adapter into the vehicle s DC accessory power port outlet. 3. Have a qualified mechanic check electrical system while igo is attached. a. Plug unit into AC power or replace discharged battery with charged battery. b. Plug unit into DC accessory power port outlet to operate unit. NOTE Battery will not recharge on DC power. 1. Fully discharge battery then recharge. 1. Battery needs to be reconditioned. 2. Defective battery. 2. If the above solutions do not work, contact BOC on 0800 136 603. Unit is equipped with built-in battery test and the battery pack is being checked. If light flashes longer than 10 minutes, battery is defective. Contact BOC for a replacement. Any other issues. Contact BOC on 0800 136 603.

If you are visually impaired and require a large print copy, please contact us. BOC Healthcare is an authorised distributor of igo manufactured by DeVilbiss. Pictures are courtesy of DeVilbiss. Contact us. Our normal working hours are Monday to Friday 8am until 5.30pm. We are open 24 hours for emergencies only. BOC Healthcare Patient Service Centre, Priestley Road, Worsley, Manchester M28 2UT, United Kingdom Tel 0800 136 603, Fax 0800 169 9989, healthcare.home-uk@boc.com www.bochealthcare.co.uk HLC/406750/0811 The stripe symbol and the letters BOC are registered trade marks of The BOC Group Limited. Both BOC Limited and The BOC Group Limited are members of The Linde Group, the parent company of which is Linde AG. Reproduction without permission is strictly prohibited. BOC Limited 2012