Data Sheet Issue E

Similar documents
Data Sheet 11.1 Issue A

MEDIUM VELOCITY WATER SPRAY NOZZLE

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

Data Sheet 11.2 Issue B

MEDIUM VELOCITY WATER SPRAY NOZZLE

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

WATER SPRAY NOZZLE DATA SHEET

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

INLINE FOAM INDUCTOR HD FIRE PROTECT PVT. LTD. TECHNICAL DATA DESCRIPTION SPECIFICATION APPLICATION SYSTEM DESIGN DETAILS

model E Spray nozzles vk810 - vk817

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

MODELS F822 THRU F834

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

Models P420A-3100 & P420A-5100

TECHNICAL DATA OBSOLETE

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

STYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

HR-20P Pneumatically Controlled Pressure Regulator

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

INSTALLATION & MAINTENANCE GUIDE

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Grinnell Grooved Fire Protection Products Grooved Fittings

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of.05 gpm/ft 2

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Service Guide JATCO Environmental Protection Tank Model J-7000

Installation Instructions / Warranty. Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1

TECHNICAL DATA Code No. SFM-OH1 SFM-OH2 SFM-OH3 SFM-OH3S SFM-XHH-10 SFM-XHH-7.5 SFM-XLH

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual SP100W/SP351W

Installation Instructions / Warranty. Axor Citterio M 34315XX1

Installation Instructions / Warranty

DELUGE VALVE DATA SHEET

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

Intended Use: Explanation of Signal Word Consequences

Installation Instructions

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

Installation Instructions / Warranty

AMERICAN AVK COMPANY TABLE OF CONTENTS

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

OWNERS MANUAL HF4263

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Telescoping Pressure Washer Wand 18'

Installation Instructions / Warranty

FIGURE 310A & 311A 3-PIECE BALL VALVE

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

Installation Instructions / Warranty. Axor Citterio 39835XX1

GM Specification Annual Test Data

DAP-625S and DAP-875S

The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor.

HALLMARK INDUSTRIES INC

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

QUALITY MISTING PUMPS

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

GM Specification Annual Test Data

Installation Instructions / Warranty

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Installation Instructions / Warranty. Citterio 39115XX1

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Model CP470. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

TBM Series 3-Way Ball Valve

Model GP5128. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

INSTALLATION AND OPERATING MANUAL

Installation Instructions

Operations Manual. and. Seal Kit Replacement Guide

Victaulic Discharge CBV Vibration Isolation Pump Drop Series 383/383G

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

OWNERS MANUAL HF4261

Model LP122A Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Questions, problems, missing parts? If you have questions about this product or need technical support, call the Amerisun customer service department

J. & M. Mfg. Co., Inc. 284 Railroad Street - P.O. Box 547 Fort Recovery, OH Ph: (419) Fax: (419)

WEB CONTROL PRODUCTS

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Transcription:

Data Sheet. General Description s are open type (nonautomatic) nozzles, designed for directional spray application in fixed fire protection system. Medium velocity water spray nozzle has an external deflector, which discharges water in a directional cone shaped pattern of small droplet size. The water is uniformly distributed over the surface to be protected. The Nozzles are effectively designed to apply water to exposed vertical, horizontal, curved and irregular shaped surfaces to allow cooling to prevent excessive absorption of heat from external fire and avoid structural damage or spread of fire. In some application nozzles may be installed to control or extinguish the fire depending on water design density as per applicable codes. The nozzle is used in deluge water spray system for special hazard fire protection application. As the design and intent of specific water spray system may vary considerably, MV nozzle is made available in several combinations of orifice sizes and spray angles. The minimum desirable pressure to achieve a reasonable spray pattern is.4 Kg./Sq.cm. The water distribution pattern as shown in the graph in following pages is at an average pressure of. Kg/ Sq.cm. The change in pressure between.4 to.5 Kg./sq.cm. does not affect considerable change in spray angle. The spray pattern shown is with indoor application. System designer must consider wind velocity while designing the system for outdoor application. Field obstruction if any affecting the spray pattern of the nozzle must also be considered. The nozzle may be oriented to any position as deemed necessary to cover the hazard. The Blow-off plugs can be used to prevent the depositing of foreign materials in the water way of the nozzles, which could interfere with discharge of the spray nozzle. Blow-off plugs are optional and are Approved. Blow-off Plugs have identification mark with respect to K factor. Blow off plug for nozzle having K-factor will have identification mark of. Minimum operating pressure for nozzle having Blow-off plug is.4 Kg./Sq.cm ( PSI). The main pipeline strainer as per NFPA-5 is required for system utilizing nozzle orifice diameter less than 9.5mm (/8 inch), i.e.mv Nozzle having K-factor 5 and less, and also for the system water likely to contain obstructive materials Technical Details Model Type Maximum Working Pressure End Connection Included Water Spray Angle For Each K-Factor K-Factor Weight Finish Approvals Ordering Information MV-A, MV-AS Brass MV-B & MV-BS Stainless Steel MV-E Aluminium Bronze MV-A, MV-B & MV-E (without strainer) MV-AS & MV-BS (with strainer) bar (75 psi) ½" BSPT (½" NPT optional) 4,,,, 9, 8 & 65 MV-A/MV-B & MV-E MV-AS/MV-BS Metric(US) Metric(US) K-8 (.6) K-8 (.6) K- (.54) K- (.54) K- (.) K- (.) K-5 (.45) K-5 (.45) K-4 (.87) K-4 (.87) K-5 (.57) K-64 (4.48) K-79 (5.5) K-9 (6.7) K- (7.4) g. (approximately) MV-A & MV-AS Natural Brass finish, Chrome plated Nickel, Electroless Nickel plated, Epoxy powder coated. MV-B, MV-BS & MV-E Natural finish Nozzle - UL Listed, Approved Blow-off Plug - Approved Specify K-Factor, spray angle, finish, model and end connection DS:. /5/8 8 Rapidrop T: +44 () 7 847 5 F: +44 () 7 55 958 Page of 6

Data Sheet. Installation & Maintenance The spray nozzle must be handled with due care. For best results, the storage as well as any further shipment be made in original packing only. Nozzle which is visibly damaged should not be installed. Use Teflon tape or soft thread sealant on male thread of the nozzle. The nozzles must be hand tightened into the fitting. After hand tightening use Nozzle Wrench- NW-M for wrench tightening in to nozzle fittings. Excessive tightening torque may result into serious damage to nozzle arms and the deflector, which may affect spray pattern of the nozzle and its performance. It is recommended that water spray system be inspected regularly by authorised technical personnel. The nozzle must be checked for atmospheric effects, external and internal obstruction, blockage if any. The system must be operated with optimum water flow at least twice in a year or as per the provisions of NFPA /TAC or local authority having jurisdiction. The owner is solely responsible for maintaining the water spray system and the components there in so that it performs properly when required. Nozzle with Blow-off Plug 64± Model MV-A, MV-B & MV-E 46± R ½ BSPT Model MV-AS & MV-BS 46± BLOW OFF PLUG (OPTIONAL) 84± 64± R DEFLECTOR PIN HOUSING ½ BSPT STRAINER Table - I : Material Of Construction Component Model MV-A & MV-AS Model MV-B & MV-BS Model MV-E Housing Brass, IS:9 GR.- (Equivalent to ASTM B) A5-CF8M Aluminium Bronze IS:5-AB (Equivalent to ASTM B48) Pin Brass IS:9. GR. - (Equivalent to ASTM B) ASTM-A479 GR 8 Ph.Bronze IS:78 (Equivalent to ASTM B9) Deflector Brass IS:768 (Equivalent to ASTM B6) ASTM A4 GR 5 Ph.Bronze IS:784- GR-II (Equivalent to ASTM B) Strainer Copper (For MV-AS) Stainless Steel 6 (For MV-BS) - Blow-off Cap Elastomer Elastomer Elastomer DS:. /5/8 8 Rapidrop T: +44 () 7 847 5 F: +44 () 7 55 958 Page of 6

Data Sheet. P - PRESSURE IN Kg./Sq.Cm. 7 6 5 K 8 K Discharge Characteristics FLOW IN GPM 4 5 6 7 K K 5 K4 K5 4 6 4 8 6 Q - DISCHARGE - LPM FROM NOZZLE K6 4 K7 9 K9 K 8 6 4 PRESSURE IN PSI Q =K P where P is supply pressure in Kg/sq.cm., K= nozzle constant (K-factor) in metric US K factor = Metric K factor MK 4.745.4.8..4.8...8.4.4.8..4.8..4.8...8.4.4.8. SPRAY ANGLE 65 o..8.4.4.8....8.8.4.4 4 4 SPRAY ANGLE 8.4.8..4.8..4.8..4.8. TO P VIEW..8.4.4.8...8.4.4.8...8.4.4.8....8.8 4 4.4.4 DS:. /5/8 8 Rapidrop T: +44 () 7 847 5 F: +44 () 7 55 958 Page of 6

Data Sheet. SPRAY ANGLE 9.4.8..4.8..4.8..4.8. TO P VIEW..8.4.4.8...8.4.4.8. 4 4..8.4.4.8....8.4.8.4 SPRAY ANGLE.4.8..4.8..6..8.4.4.8..6.4.8..4.8..6..8.4.4.8..6 4 4..8.4.4.8....8.4.8.4 DS:. /5/8 8 Rapidrop T: +44 () 7 847 5 F: +44 () 7 55 958 Page 4 of 6

Data Sheet. SPRAY ANGLE.4.8..4.8..6..8.4.4.8..6..6..8.4.4.8..6. 4 4..4.8..4.8....8.4.4.8....8.4.8.4 SPRAY ANGLE.4.8..4.8.. 6..8.4.4.8..6... 6..8.4.4.8..6.. 4 4.6..8.4.4.8..6...8.4.8.4 DS:. /5/8 8 Rapidrop T: +44 () 7 847 5 F: +44 () 7 55 958 Page 5 of 6

Data Sheet. SPRAY ANGLE 4.4.8..4.8.. 6..8.4.4.8..6...4.8..4.8..6..8.4.4.8..6. 6..8.4.4.8..6.. 4 4.8.4.8.4 VE RT ICAL UP WA RD SPRA Y Limited Warranty Products supplied by Rapidrop (RD) are warranted against defects in material and workmanship for a period of Two () years from the date of shipment. RD s obligation under this warranty is limited to replace or repair the products or its parts, which are shown to RD s examination to be in a defective condition attributable to RD. No warranty is given for products or components which have been subject, to misuse, improper installation, corrosion, wear and tear improper storage, modification or repaired. If the defect attributable to RD cannot be rectified by repair or replacement, then RD may elect to refund the purchase price of the equipment in complete discharge of its obligation under this Limited Warranty. IN NO EVENT SHALL RAPIDROP BE LIABLE IN CONTRACT, STRICT LIABILITY OR ANY OTHER LEGAL THEORY, FOR INCIDENTAL, IN-DIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING DAMAGES. FOR INJURY TO PERSON OR DEATH OR DAMAGE TO PROPERTY AND OR PENALTIES RESULTING FROM ANY PRODUCTS OR COMPONENT MANUFACTURED OR ASSEMBLED BY RD. THIS IS LIMITED WARRANTY ONLY. RD DISCLAIMS WITH RESPECT TO THE PRODUCTS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY RD BEYOND AS STATED ABOVE. Notice : The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherever applicable. The information provided by us are to the best of our knowledge and belief, and are general guidelines only. Site handling and installation control is beyond our reach. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or damages due to our product. Product development is a continuous programme of RAPIDROP and hence the right to modify any specification without prior notice is reserved with the company. DS:. /5/8 8 Rapidrop T: +44 () 7 847 5 F: +44 () 7 55 958 Page 6 of 6