SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

Similar documents
SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website: only in English version

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

유량계전문제조업체. Electro Magnetic FLOWMETER

WATERFLUX 3000 Technical Datasheet

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

OPTIFLUX 6000 Technical Datasheet

WATERFLUX 3070 Technical Datasheet

OPTIFLUX Electromagnetic Flow Sensor

ISTEC MAGNETIC METERS

Electromagnetic Flowmeters. Product Overview.

Magnetic Inductive Flowmeter EP / UMF2 (B)

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

SITRANS F M flow sensors 711/A and 711/911E

WATERFLUX 3070 Technical Datasheet

Field IT Electro-Magnetic Flowmeters Sensors

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Magnetic-inductive flow meter for hazardous areas

Electromagnetic Flow Monitor magphant

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

Options guide. Electromagnetic flowmeters. M9xx

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

Electromagnetic Flow Monitor magphant

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

Electromagnetic Flow Measurement

OPTIMASS 2000 Technical Datasheet

Insertion magnetic inductive flowmeter

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Electromagnetic Flow Meter Owner s Manual HARDWARE

Smart Electromagnetic Flowmeter Detector for Sanitary use

Full Profile Insertion

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Flow Measurement SITRANS F M

HTM Series Helical Turbine Meters

Technical Information Proline Promag 10L

Electromagnetic amplifier type ModMAG M10 for all detectors

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

SITRANS F M. Flow sensor MAG 1100 F 3/59

Electromagnetic flowmeters

UniMag DT Series Electromagnetic Flow Tubes

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Electromagnetic flowmeters for water and seewage

BATCHFLUX 5500 C Technical Datasheet

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Electromagnetic flowmeter EMKO E

Positive Displacement Flowmeters

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

SITRANS P measuring instruments for pressure

Turbine flowmeters Series TM

OPTIMASS 3000 Technical Datasheet

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Design and application

Electromagnetic Flow Measuring System PROline promag 10 W

Detector (for water measurement applications)

LCMass Series Mass Flow Sensor

AquaMaster4 Electromagnetic flowmeter flanged sensor

TOPAS PMW-basic. Customer benefits. Product features

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Flow Measurement SITRANS F S Clamp-on

CM2-MGG User s Manual

Marsh McBirney Flo-Dar

Level Limit Switch liquiphant FTL 365 / FTL 366

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements

Signet 2551 Magmeter Flow Sensor

SATRON VDt Differential Pressure Transmitter

Electromagnetic amplifier Primo Advanced for all detectors

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

SATRON VT Pressure Transmitter

Design and applications

Proline Promag 10L. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications

tprime TM Series 280T

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Flow Measurement SITRANS F M

GA 24 Heavy-duty variable area flowmeter

Datasheet Rev.1 Feb 2014 High precision flowmeter

SATRON VTe pressure transmitter

Materials : Cast iron body EN GJL-250

FLOWX3 F3.60M.S Insertion Magmeter

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Flowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request

ULTRASONIC HEAT METER

STEEMCO-MAS Flowmeter for Steam

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Proline Promag W 400. Technical Information. Electromagnetic flow measuring system The specialist for all water and wastewater applications

Differential-Pressure Flow Meter

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Transcription:

SENSOR MUT2300 Electromagnetic flowmeter The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

Sensor MUT2300 The MUT2300 sensors represent the state of the art of Euromag International production for water cycle and process applications. The innovative inner part of the sensor that increase considerably the liquid flow rate and the reading accuracy of signal generated to the electrodes, enables an extremely wide range of measurement. These performances allow to measure also low flow rates precisely and repeatable, even in difficult/problematic applications with solid parts. This flanged sensor series bases its operation on the Faraday Principle, by which a conductor crossing a magnetic field generates an electrical potential perpendicular to the field itself. On the top and on the lower side of the stainless steel AISI 304 flow tube, two coils are installed; the magnetic field generated by the electric current crossing the coils, induces in the electrodes a potential difference proportional to the flow rate. With the aim of measuring such potential of very low values, the interior of the flow tube is electrically insulated, thus the process liquid is no longer in contact neither with the material of the flow tube nor with that of the flanges. The converter used generates the current supplying the coils, acquires the electrodes potential difference, process the signal to calculate the flowrate and manages all the communications. The entire sensor has an IP68 protection degree suitable for a permanent immersion in water up to a depth of 1.5m. 2 www.euromag.com DS401-1-ENG

Body and flanges The flanges and the sensor external surface are acrylic painted. This treatment gives the sensor an excellent resistance to water and external agents even in permanent immersion or buried. The MUT2300 may be supplied in stainless steel, flanges included, or with a special paint ideal for application in C4 class environment (UNI EN ISO 12944-2). Internal lining The standard internal insulating lining is in Hard rubber (Ebonite) in compliance with WRAS, FDA and DM174 standards. The liquid temperature can reach 80 C. Thanks to its high resistance to scraping, the Ebonite is considered the best material for fluids containing scattered solids for applications of water treatment, residual water, potable water and irrigation. MUT2300 - MC608A Electrodes The standard electrodes are in Hastelloy C and therefore this guarantees a wide compatibily with process fluids. If required, they may be supplied in Hastelloy B, Titanium, Tantalum and Platinum. A partially empty tube detection (fourth electrode) is installed and can be enabled or disabled through the software. Coupling and connection to the sensor MUT2300 - MC406 VERTICAL MUT2300 sensors may be coupled with any Euromag converters. In the separate version the sensor is connected to the converter through a cable whose length depends on the liquid conductivity; the maximum length must not exceed 100 metres on the powered version and 30 metres on the battery version. Neglectable pressure drop The electromagnetic flowmeters do not have any moving internal parts, thus they have a very low pressure drop. The OIML R-49 permits a maximum pressure drop of 630 mbar at velocity of about 8 m/s. The MUT2300 flowmeters, thanks to its unique design, projected to accelerate the flow and amplify the signal to the electrodes, guarantees a pressure drop less than 250 mbar at velocity of 8 m/s. The pressure drop is always less than 10 mbar at velocities lower than 1 m/s. MUT2300 - MC406 VERTICAL MUT2300 - MC608A MUT2300 Electromagnetic flow meter 3

Installation with no upstream and downstream distances The cone shaped section of the internal part of the sensor, allows an optimized and accelerated flow profile which permits to install the sensor in any kind of condition; no need to have straight sections/segments of pipes upstream and downstream. This U0-D0 condition enables to have an extreme flexibility on the flowmeter installation position. Standards reference The Euromag magnetic meters are marked CE and are manufactured according to the following standards: 2014/35/EU - EN 61010-1:2013 (LVD) 2014/30/EU - EN 61326-1:2013 (EMC) OIML R49-1:2013 European directive 2014/32/EU (MID) 2014/34/UE - IEC 60079-0, IEC 60079-18 (ATEX - IECEx) Separate version EN ISO 15609-1 and EN ISO 15614-1 UNI EN ISO 12944-2, painting for C4 class environments (on request) Ebonite conform to the norms WRAS, FDA e DM174 Applications Measure of potable or reflow water Distribution, municipal water Industrial waste water Over night applications with very low flow rate Industrial process liquids, muds and concretes Installation in small places without straight distances Leakage detection Fiscal measures, irrigation Advantages No moving parts No parts inside of the flowmeter No obstruction on the flow tube Very low pressure loss (below 1 m/s is irrelevant) Long lasting stability and precision, no filter needed, zero maintenance No periodic cleaning Accurate measure at high flow rate (firefighting systems) and at low flow rates (overnight flow rates) Extremely sturdy structure, a dedicated robot welds all the parts, internal parts protected by a bi-component resin in order to increase protection from external agents Ideal for pit installations even for permanent immersion in water or buried installations Bi-directional measure Technical features MUT2300 Flow tube material AISI 304, AISI 316 (optional) Flanges material Carbon steel (S235JR - 1.0037), AISI 304 optional, AISI 316 optional Available electrodes Hastelloy C (standard), Hastelloy B, Titanium, Tantalum, Platinum Internal lining Ebonite Liquid temperature -40 C / + 80 C Available mm 50 65 80 100 125 150 200 250 300 diameters inches 2 2½ 3 4 5 6 8 10 12 Standard flanged connections EN1092-1 PN 16, ANSI 150 Flanged connections on request AS 2129 (Table D, E, F), AS 4087 (PN 16, 21), KS10K, others on request Standard operation pressure 21 bar Pressure drop class DN 80 ΔP25 (< 0,25 bar) DN 100 ΔP40 (< 0,40 bar) Installation requirements/conditions U0-D0 Protection Degree IP68 permanent submersion at 1,5 m (EN 60529) Convertes compatibility MC608A/B/R/P, MC406 Electrical connections Cableglands M20 x 1.5 + terminal box + sealing resin 4 www.euromag.com DS401-1-ENG

Calibration and maximum error MUT2300 sensors belong to the reference Group B1 (ISO 11631). Each sensor is calibrated by an hydraulic bench equipped with a reference weighting system and ACCREDIA certified. The uncertainty of the calibration is equal to 0,2% ± 2mm/s. The repeatability of the measure is about 0,1%. Bi-directional measure. Furthermore the sensors are certified MID01 norms (if coupled to MC406 converters) for custody transfer Maximum Permissible Error is within the limits indicated in the following graph: Flow rates chart Sensor diameter Flow [m3/h] Min Q1 Trans. Q2 Q0,4% Perm. Q3 Overl. Q4 Ratio Q3/Q1 DN50-2" 0,125 0,20 3,50 25,00 31,25 200 DN65-2"1/2 0,20 0,32 6,00 40,00 50,00 200 DN80-3" 0,315 0,50 9,00 63,00 78,75 200 DN100-4" 0,50 0,80 14,00 100,00 125,00 200 DN125-5" 0,80 1,28 22,00 160,00 200,00 200 DN150-6" 1,25 2,00 32,00 250,00 312,50 200 DN200-8" 3,15 5,04 57,00 630,00 787,50 200 DN250-10" 5,00 8,00 90,00 1000,00 1250,00 200 DN300-12" 8,00 12,50 128,00 1000,00 1250,00 125 MUT2300 Electromagnetic flow meter 5

MUT2300 - MC406 HORIZONTAL 183 112 102 H1 H 125 MC406 HORIZONTAL DN H H1 50 - (2 ) 62 187 65 - (2" 1/2) 62 187 80 - (3") 71 196 100 - (4") 79 204 125 - (5") 106 231 150 - (6") 101 226 200 - (8") 147 272 250 - (10") 176 301 300 - (12") 207 332 6 www.euromag.com DS401-1-ENG

MUT2300 - MC406 VERTICAL 183 112 126 H H1 126 MC406 VERTICAL DN H H1 50 - (2 ) 62 188 65 - (2" 1/2) 62 188 80 - (3") 71 197 100 - (4") 79 205 125 - (5") 106 232 150 - (6") 101 227 200 - (8") 147 273 250 - (10") 176 302 300 - (12") 207 333 MUT2300 Electromagnetic flow meter 7

MUT2300 - MC608 A/B/R 171 125 MC 608 A MC 608 B 142 247 173 68 106 H1 H 85 64 MC608 A/B/R DN H H1 50 - (2 ) 62 211 65 - (2" 1/2) 62 211 80 - (3") 71 220 100 - (4") 79 228 125 - (5") 106 255 150 - (6") 101 250 200 - (8") 147 296 250 - (10") 176 325 300 - (12") 207 356 8 www.euromag.com DS401-1-ENG

MUT2300 - SEPARATE 123 30 N 2 - M20 86 D5 J 72 H S 27 2 x M5 N L4 Di D6 MUT2300 - EN 1092 / PN 16 DN D5 L4 J Di D6 N S H 50 85 200 (+0/-3) 87,35 30,4 125 4 18 114,5 65 85 200 (+0/-3) 87,35 34,3 145 4 18 114,5 80 103 200 (+0/-3) 96,35 46,3 160 4 18 123,5 100 118 250 (+0/-3) 103,85 62,1 180 8 18 131 125 172 250 (+0/-3) 130,85 74,9 210 8 18 158 150 163 300 (+0/-3) 126,35 100 240 8 22 153,5 200 255 350 (+0/-3) 172,35 154,3 295 8 22 199,5 250 312 450 (+0/-5) 200,85 205 350 12 22 228 300 375 500 (+0/-5) 232,35 259 400 12 22 259,5 MUT2300 Electromagnetic flow meter 9

MUT2300 - ANSI 150 DN D5 L4 J Di D6 N S H 2 - (DN 50) 85 200 (+0/-3) 87,35 30,4 120,65 4 19,05 114,5 2" 1/2 - (DN 65) 85 200 (+0/-3) 87,35 34,3 139,7 4 19,05 114,5 3" - (DN 80) 103 200 (+0/-3) 96,35 46,3 152,4 4 19,05 123,5 4" - (DN 100) 118 250 (+0/-3) 103,85 62,1 190,5 8 19,05 131 5" - (DN 125) 172 250 (+0/-3) 130,85 74,9 215,9 8 22,352 158 6" - (DN 150) 163 300 (+0/-3) 126,35 100 241,3 8 22,352 153,5 8" - (DN 200) 255 350 (+0/-3) 172,35 154,3 298,45 8 22,352 199,5 10" - (DN 250) 312 450 (+0/-5) 200,85 205 361,95 12 25,4 228 12" - (DN 300) 375 500 (+0/-5) 232,35 259 431,8 12 25,4 259,5 MUT2300 - AS 2129 / Table D DN D5 L4 J Di D6 N S H 50 85 200 (+0/-3) 87,35 30,4 114 4 18 114,5 65 85 200 (+0/-3) 87,35 34,3 127 4 18 114,5 80 103 200 (+0/-3) 96,35 46,3 146 4 18 123,5 100 118 250 (+0/-3) 103,85 62,1 178 4 18 131 125 172 250 (+0/-3) 130,85 74,9 210 8 18 158 150 163 300 (+0/-3) 126,35 100 235 8 18 153,5 200 255 350 (+0/-3) 172,35 154,3 292 8 18 199,5 250 312 450 (+0/-5) 200,85 205 356 8 22 228 300 375 500 (+0/-5) 232,35 259 406 12 22 259,5 MUT2300 - AS 2129 / Table E DN D5 L4 J Di D6 N S H 50 85 200 (+0/-3) 87,35 30,4 114 4 18 114,5 65 85 200 (+0/-3) 87,35 34,3 127 4 18 114,5 80 103 200 (+0/-3) 96,35 46,3 146 8 18 123,5 100 118 250 (+0/-3) 103,85 62,1 178 8 18 131 125 172 250 (+0/-3) 130,85 74,9 210 8 18 158 150 163 300 (+0/-3) 126,35 100 235 8 22 153,5 200 255 350 (+0/-3) 172,35 154,3 292 8 22 199,5 250 312 450 (+0/-5) 200,85 205 356 12 22 228 300 375 500 (+0/-5) 232,35 259 406 12 26 259,5 MUT2300 - AS 4087 / PN 16 DN D5 L4 J Di D6 N S H 50 85 200 (+0/-3) 87,35 30,4 114 4 18 114,5 65 85 200 (+0/-3) 87,35 34,3 127 4 18 114,5 80 103 200 (+0/-3) 96,35 46,3 146 8 18 123,5 100 118 250 (+0/-3) 103,85 62,1 178 4 18 131 125 172 250 (+0/-3) 130,85 74,9 210 8 18 158 150 163 300 (+0/-3) 126,35 100 235 8 18 153,5 200 255 350 (+0/-3) 172,35 154,3 292 8 18 199,5 250 312 450 (+0/-5) 200,85 205 356 8 22 228 300 375 500 (+0/-5) 232,35 259 406 12 22 259,5 10 www.euromag.com DS401-1-ENG

Zero upstream and downstream distances MUT2300 Electromagnetic flow meter 11

gasweb.it DS401-1-ENG EUROMAG INTERNATIONAL Srl Via della Tecnica, 20-35035 Mestrino (Padova) Italia Tel. +39 049.9005064 - Fax +39 049.9007764 www.euromag.com - www.euromagdata.com euromag@euromag.com All rights reserved. No part of this catalogue may be reproduced, stored in a database or otherwise used without the authorisation of Euromag. The policy of Euromag is dictated by the continuing technological and project innovation. Therefore, the Company reserves the right to amend the data contained herein without notice.