Fig Blast tube 2.Asbestos gasket 3.Flange 4.Body gasket 5. Brake plate. 6. Oil n ozzle 7.Heater 8.Rubber block 9. Transformer 10.

Similar documents
Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

CODE MODEL TYPE PRESS GW 605 T80

High pressure float valve, type HFI REFRIGERATION AND AIR CONDITIONING. Technical leaflet

X-Series Spare Parts List

M SERIES TECHNICAL DATA INFORMATION PACKET

Float valve Type HFI. Data sheet

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod

Kerosene - oil burner

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

Oil - kerosene burner

Mobile Diesel Heaters TOR / MIR Technical Training Course

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

MASTER DIRECT OIL HEATERS. MODEL 35 CED 10 kw Model ILLUSTRATED PARTS BREAKDOWN. Motor and Pump Assembly

SPARE PARTS MANUAL VAL HEATERS

Installation- and maintenance instruction ST120 S75/21

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

PRESS P/N - P/N ECO SERIES

CREATIVE EQUIPMENT CC 18 Main Road, Fishers Hill, Germiston, 1401 Tel: Fax:

Installation- and maintenance instruction BENTOFLEX ST 108 PL

D SERIES TECHNICAL DATA INFORMATION PACKET

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

D SERIES TECHNICAL DATA INFORMATION PACKET

HELICAL COIL HEATERS REPLACEMENT PARTS HEATEC AN ASTEC COMPANY HC AND HCS SERIES

Installation- and maintenance instruction BENTOFLEX ST120KAV

RAYPAK ILLUSTRATED PARTS LIST

VAL6 KBE5S. Service Manual

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

Installation- and maintenance instruction BENTOFLEX ST133KA/K

Light oil - kerosene burner

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

MULTIFIRE. High temperature dual fuel burner

RAYPAK ILLUSTRATED PARTS LIST

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

CENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis.

Installation- and maintenance instruction B20KAV/KV

XL9 E-S Serial number N for XL9 E Edition 2005

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction B20KA/K

RAYPAK ILLUSTRATED PARTS LIST

Surefire II TM Pilot Forced Draught Gas Pilot type SP-32-NG/PG-FD Instruction Manual

RAYPAK ILLUSTRATED PARTS LIST

XL9E-S Edition2005. Serial numbern forxl9e

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

Parts List Book CPE CPVS

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

Doing more for clean environment and energy saving

Installation- and maintenance instruction B20K-2

S1 SERIES TECHNICAL DATA INFORMATION PACKET

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

GAS BURNERS BLU 3000 PR BLU 4000 PR

Infrared oil heater. Model. Type. KBE5S for 120V 60Hz KBE5L for 120V 60Hz KBE5L 2-step for 120V 60Hz KBE1S for 230V 50Hz

SureFire II TM Natural Draught Gas Pilot type SP-48-NG/PG-ND Instruction Manual

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

DANESMOOR 20/25-OOO /14 Bu rner. 9 Additional re Spa Parts. 7A 15/19 Bu rner 7B 20/25 Bu rner. Spare parts list

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

ONE STAGE GAS BURNERS RDBS SERIES

SER'IICING. CORlJAIR HEATER. the

BOILER PM & INSPECTION

Installation- and maintenance instruction BENTOFLEX ST133K

Installation- and maintenance instruction B45A2.2

Alkaline Etching Machine

SECTION 6A1-2 - ENGINE MECHANICAL - V6 SUPERCHARGED

Kalahari & GlowPlus. Kalahari and GlowPlus Heaters Issue 1. Nov 09

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

Spare parts list DANESMOOR 26/32-OOO. Burner Additional re Spa Parts 23/04/

Webasto Product North America North Road Fenton, MI Phone: Fax:

DX 800, 810, 820, 830, Titan

The Discussion of this exercise covers the following points:

CODE OF GOOD PRACTICE

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

Oil, Gas and Dual Fuel Burners

What is the secret to INOV8 s Burner Technology?

INSTALLATION INSTRUCTIONS FOR THE PHOENIX FIBER OPTIC FLAME SCANNERS

OIL REGULATORS RFG SERIES FEATURES APPLICATIONS DESCRIPTION INSTALLATION. Bulletin E5301 rev03 02/04/03. Body and valve seat: Shutter seat:

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

SPARE PARTS LIST. for. Infrared oil heater. Model. Type. EPX5 for 120V 60Hz. May, 2017

Cautions in Using The Relays 1/5

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

Part List: Jandy LXI Series Heaters

Oil, gas and dual fuel burners. Burner series

XIII. Repair Parts 106

Belt Driven Compressor Operation Manual Model No. SACBD-100

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

VMK Oil burners fuel unit with 2 stages operation

Installation and Maintenance Manual Please retain this manual for future reference.

Power Flame Incorporated

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

Table Of Contents. Profire M Burner. Gas, #2-5 Oil, #2-6 Oil, or Combination. Installation Operation Maintenance Parts

PARTS CATALOG M50/M80/M Volt and 24 Volt

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

G-I PCM SERVICE MANUAL M50/M80

Transcription:

DESCRIPTION Fig. 1 1.Blast tube 2.Asbestos gasket 3.Flange 4.Body gasket 5. Brake plate 6. Oil n ozzle 7.Heater 8.Rubber block 9. Transformer 10. Controller base 11.Motor 2.Photocell 13. Controller 14. Compressor air 15. Reset button 16.Cover 17. Air regulator 1 8. Body screw 19.Oil temperature 20. Seal gas ket 21. Heating tube 22. Limit s of controller 23. Level switch 24. Level height adjust or 25. Oil tank 26.Level switch base 27. Float bal l 28.Overflow connector 29. Oil tank cover 30. Oil inlet connector 31. Filter 32. Oil pipe 33. Air inlet 1

BURNER ACCESSORIES No. Description QTY No. Description QTY 1 Transfer oil pump 1PC 6 Install screw 4 2 Air controller 1PC 7 Inner six angle spanner 1 3 Install flange 1PC 8 Nozzle Spanner 1 4 Asbestos gasket 1PC 9 Oil filter 1 5 Outlet-inlet pipe 2PC 10 Oil line connector 4 TECHNICAL DATA Item no. Cap. Motor Nozzle Combustion Transfer Power (KW ) Qty (KG ) Motor Supply STW120 -P 10-50 130W 1 1-4 120W 230V/50Hz STW120 12-50 90W 1 1-4 120W 230V/50Hz STW133-1 40-80 130W 1 3-7 180W 230V/50Hz STW133-1P 40-80 180W 1 3-7 180W 230V/50Hz STW133-2P 70-115 220W 2 6-10 180W 230V/50Hz STW133-2 70-115 130W 2 6-10 180W 230V/50Hz STW146-2 70-139 150W 2 6-12 180W 230V/50Hz STW146-2P 70-139 250W 2 6-12 180W 230V/50Hz STW146-3 115-200 180W 3 10-18 180W 230V/50Hz 2

OVERALL DIMENSIONS Fig. 2 A B C D E F G STW120 338 242 172 78 85 204 89 STW133 370 268 196 95 105 196 95 STW146 380 268 196 95 115 196 114 FLANGE DIMENSIONS A B C STW120 120 160 11 STW133 145 170 11 STW146 145 170 11 Fig.3 3

AIR PUMP STRUCTURE DIAGRAM WARNING: this air pump is no oil pump, is strictly prohibited to add lubricating oil. Fig.4 STW120 AIR PUMP 34. Air inlet 35. Pressure regulator 36.Pressure port 37.Air outlet 39.Coupling Fig.5 STW133 AIR PUMP 1. Pressure regulator 2. Solenoid 3. Pressure port 4. Air outlet 5. Air inlet 4

IGNITION ADJUSTION Fig.6 NOZZLE DATA (COMBUSTION ADJUSTMENT) 5

AIR CONTROLLER (WITHOUT AIR PUMP) 1. Fixed base 2. Air regulating handle 3. Pressure gauge 4. Burner connector (6mm) 5. Solenoid valve 6. Air filter 7. Drainage outlet 8. Air inlet connector (8mm) Fig.7 TRANSFER OIL PUMP Fig.8 40. Oil flow rate adjusting handle 41. Oil outlet (to oil tank) 42. Fixed base 43. Oil inlet connector 44. Oil pump 6

BURNER INSTALLATION Warning: the storage oil tank cannot be higher than the burner. Fig.9 1 Accesso ries oil pipe connect with Fig.1-30 and Fig.8-41. 2 Access ories oil pipe connect with Fig.8-43 and connect a ccessories oil filter to Storage oil tank. 3. Fig.1-14 connect with Fig.7-4. 4. Fig.7-8 connect with air source. THE HEIGHT OF LIQUID LEVEL ADJUSTMENT 1 Adjust screw Fig.10-1 to a djust the level upper limit 2 Release Fig. 10-2, M ove up Or move down can adjust the upper or lower limit of the height for floating ball. Fig. 10 7

OIL FLOW CONTROL In order to reduce the frequent start of the transfer oil pump and instant cooling the oil temperature in hea ng oil tank, adjust handle no. 40 in Fig. 8. And control inlet oil rate to get the suitable oil flow rate. (With just over burning oil is better TEMPERATURE- SETTING Rotate the temperature control switch in Fig.1 to set the preheat temperature. In general, engine oil is 80-90 degree, vegetable oil is 110-120 degree. AIR PRESSURE- SETTING Air pressure factory se ng is in 0.35bar-0.4bar, too high air pressure will cause igni on di cult or cause oil atomiza on not good. WARNING: the overflow pipe in preheating tank Fig.1-28 must connect back oil to Storage oil tank WORK PRINCIPLE Turn on power supply, and then preheat oil, about 5-10 minutes (di erent kinds oil at di erent preheat oil mes), a er arrived at the set temperature, turn on the control box. Turn on Fig.1-15 to start burner. 1. Test photocell (dark). 2. Pre-purging and igni on (Normal working me is 13s). 3. Open air valve, injec on oil. 8

4. Test photocell (bright). 5. A er the normal combus on, oil level in hea ng tank will rise or drop by oa ng ball to control transfer oil pump. FAULT LOCATION 1. Turn on power supply, transfer oil pump cannot work. a. Check motor and oil pump, whether the oil viscosity is too high to cause the transfer oil pump cannot start. b. Check the oil pump whether blocked by oil impuri s. c. Check whether because blocked to make the oil pump connector slide. 2. A er started the burner, stop work because have not make pre-purge me just igni on directly, fault lamp turn on. Check the air solenoid valve cannot close whether because blocked by sundries. 3. A er started the burner, stop work a er pre-purged and fault lamp turn on. Check the photocell, the control box have not detected photocell was dark. 4. A er igni on burning, ame out suddenly, and fault lamp turn on. a. Photocell damaged. b. Oil atomiza on is not good. c. Air ow is too large. d. Prehea ng temperature is not upped 5. Transfer oil pump hard to stop. Check the float ball switch whether have fault. 9

WIRING DIAGRAM 10