From: Lim Chin Heng (Engineer, Global UP Product Marketing, OYLM) Date ( )

Similar documents
CEILING CONCEALED SPLIT SYSTEM C SERIES

Designer Series. Blanket Warming Cabinet.

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Improves fan ef ciency

ADJUSTABLE FREQUENCY CRANE CONTROLS

Ductless. MRV-S (Mini VRF) Product Brochure. Higher Comfort, Haier Living. rev 01/01/2018

From: Toong Way See (Engineer, Global UP Product Marketing, OYLM) Date ( )

ELITE SERIES GARAGE DOOR OPENERS

A419ABG-3C Electronic Temperature Control

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

AFFORDABLE DUCTLESS SOLUTIONS FROM AMERISTAR

HELV NEUE BD CN 90% 51pts

Transfer switch GTEC open or delayed transition

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

High Wall Type ( 2 Series )

User Guide WARNING TWO-WAY 6-BUTTON LCD AUTOMATIC/MANUAL TRANSMISSION REMOTE STARTER SYSTEM WITH FULL ALARM SYSTEM

Motorized Roller Shades

AQUA SOLAR. Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CON TROLS

Ductless Split Systems

CB-9 CONTROL BOARD INSTRUCTION MANUAL

Garador quality automated garage door openers that you can trust

Motorized Drapery Track

Ductless Split Systems

modular multi intelligent, environmental and versatile

access

Blower Drive Checkout for 3GIBC1 Systems

INSTRUMENTATION & CONTROL

Garage Door Automation Electric garage door operators by Somfy

HERZ Electronic room thermostat analog and digital

SOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC.

34 FLASH CODE 34 - TBS LOW

Hi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI

Senior Swing Control Box. Table of Contents

Insert Residential Opener Tab Here

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

Company Profile. The Epitome of Natural Wind.

Programming Guide. Futura Spas TMTM. in.k300. in.k300. the essential spa keypad. Bright LCD screen Spa function icons. Spa function icons.

Industry s advantage. with Hydrovane. aircarecompressors.co.uk. Rotary vane air compressors for industry

Hi-Wall Inverter Split System. Efficient, effective and comfortable cooling and heating where you need it

Openers ROLLING AND OVERHEAD SECTIONAL GARAGE DOORS

ECONOMISER SERIES E2T USER MANUAL

Ducted medium static pressure monosplit DC Inverter

CONTACT YOUR AUTHORISED STOCKIST

Openers ROLLING AND OVERHEAD SECTIONAL GARAGE DOORS

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

Ditec automatic pedestrian sliding doors.

IMPORTANT SAFETY INFORMATION:

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely.

IMPORTANT SAFETY INFORMATION:

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Fan Coil Unit Product Catalogue

3200NT Timer Service Manual

Garage Door Openers & Automation

Smart Garage Door Openers Automatic Gate Openers Gate Opener Accessories Driveway Gates Driveway Alarm

ELECTRIC LOCKS. Europrofile range

With a touch of a button... Complete Line of Motorized Window Covering Systems. Intelligent Daylight Control. Energy Saving Technology

41 FLASH CODE 41 - TOO MANY SRS

Versaguard MAX Console OEM Guide

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

GTEC Transfer switch Open transition

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

SL150 Digital Speed Log Owner s Manual

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

Avanti Door Automation 8 Page Brochure FINAL 2106 PRINT.pdf 2 28/07/2016 2:19 PM The Quiet Achiever C M Y CM MY CY CMY K

A superior collection of roller blind motors and accessories, developed specifically for the internal shading industry. Simple to program,

CM 5000D IN A HURRY?

VEHICULAR AC & DC. Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage

All Product Catalogue

SUBMITTAL COVER SHEET

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

Chamberlain Wireless Universal Rolling Code Garage Door Opener Keypad Manual

Mercury HP gas-turbine. January 2008

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Product Brochure DC INVERTER MULTI-SPLIT SYSTEMS

SMT-150 Installer Manual

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Glydea Range AC Plug-in. High Performance Motorization Solutions for Draperies

Product Brochure 2018

Remote Touch unit and. Select category and scroll to specific customization setting.

BROCHURE. ABB drives for HVAC applications ACH550, 1 to 550 Hp

ABB drives for HVAC ACH580-01, 0.75 to 250 kw Catalog

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

PRODUCT INFORMATION BULLETIN

DD2-PRO+ Gps enabled Datalogger & display system mm (W) x 90mm (H) x 28mm (D) Datalogger Front 109mm (W) x 35mm (H) x 121mm (D) Datalogger Back

GARAGE DOOR OPENERS. Safety and comfort through technology

M40/50RF System - Installers Guide

IQ Gate Systems. IQ-500 Installation And Instruction Manual UL 325 and UL 991 Compliant.

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Ductless Mini-Splits

ProECU EVO X. Tuning Guide 2008-onward Model Year. v1.8

Transcription:

Dear Valued Customers, From: Lim Chin Heng (Engineer, Global UP Product Marketing, OYLM) Date (26-09-2011) SUBJECT: SLM 8 Launching of New Wired Controller SLM 8 McQuay Air Conditioning is pleased to announce the launch of SLM8, a new wired remote controller as part of McQuay Air Conditioning continuous improvement in remote controller product line up. - 1 -

Better Aesthetic Looking New sleek design of the SLM8 provides better aesthetic to present an exclusive outlook Well designed keypad for user comfort The keys are well designed with bigger buttons for better user experience Turbo and Quiet Function (To be activated at site) The SLM 8 is now designed with the Turbo and Quiet Function for additional fan speed control Note: 1. Only applicable to certain product range with Turbo and Quiet function 2. Turbo and Quiet function need to be activated at installation site by changing the jumper setting of SLM8. 3. Kindly refer to Operating Manual for more information. - 2 -

Comprehensive Error Code Display SLM 8 is capable of displaying error codes for a wide range of MQuay Unitary Products for easy troubleshooting Note: 1. Only applicable to selected product range. 2. Kindly refer to Operating Manual for more information. Compatibility with Wireless Remote Controller The availability of the Infra-Red Receiver in SLM 8 enables user to use wireless remote controller to change settings at user s convenience. Note: 1. Compatible Wireless Remote Controller: G11, G17, GS01 10 meter wire length The SLM 8 comes standard with a 10 meter wire for longer installation requirement at site. Maximum wire length for installation is 15 meter. Temperature Unit Setting ( C (Celsius) / F (Fahrenheit)) SLM 8 is capable of displaying temperature in either C or F by pressing both Temperature Up and Down button simultaneously. Allowable Temperature Range Setting (16 C - 30 C / 20 C - 30 C) SLM 8 is designed with allowable temperature setting of between 16 C and 30 C as standard. Should an application requires an allowable temperature setting of between 20 C and 30 C, it can be easily done through the jumper setting in the SLM 8. Room Temperature Sensor Depending on design application, the SLM 8 has a temperature sensor which can be used to detect the room temperature at SLM 8 installation site by the controller. However, the room temperature will not be displayed on SLM 8. - 3 -

Key Lock To prevent the settings of the wired controller being changed by users, SLM 8 comes with a key lock feature. 7 days Programmable Timer SLM 8 is designed with the 7 days programmable timer, which enables the unit be switched ON / OFF automatically according to user desired setting. Delay Timer Delay Timer enables user to select a pre-set delay of 1 hour or 2 hours to switch OFF the unit. Compatible Models SLM 8 can be used with McQuay Unitary Products which are currently compatible with Netware 3, Netware 3C or SLM 3. - 4 -

Summary of Features Features SLM 8 Temperature setting range 16 C - 30 C - Optional range 20 C - 30 C By Jumper selection. Temperature Switching ( C to F, F to C) Room Temperature Display Not Available Room Temperature sensor on handset Mode Cool / Fan / Dry / Heat / Auto Sleep mode Fan Fan Speed Selection (High, Medium, Low) - Quiet Mode By Jumper Selection - Turbo Mode By Jumper Selection Air swing selection ON / OFF Swing Mode Clock & Timer Real Time Clock Display Delay Timer 1 & 2 hours delay 7 Days Programmable Timer Additional Features Backup Battery Key Lock Function Error code indication IR receiver (Compatible with G11/G17/GS01) Further Information Should you need further clarification, please log in your enquiries through e-feedback. Thank you. - 5 -