CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

Similar documents
CSO/STORMWATER MANAGEMENT. HYDROVEX FluidGate Control Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidVertic Vertical Vortex Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX Turbo Flow Regulator

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual

ACO Water Management: Civils + Infrastructure

First Defense. Stormwater Treatment System. Operation and Maintenance Manual

EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data

INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS

Hydraulics Guide. Table 1: Conveyance Factors (English Units)... 7 Table 2: Conveyance Factors (Metric Units)... 8

C h e c k M a t e I n l i n e C h e c k V a l v e

MODEL 5A SPECIFICATION

Stormwater Treatment System

CHAPTER 12: OPERATIONS & MAINTENANCE

Regular inspections are recommended to ensure that the system is functioning as designed.

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual

MODEL 7ASX-8 SPECIFICATION

Swale Storage/ Length Between Ditch Blocks

CULVERT DESIGN WITH HY-8

Crispin Valves Operating Guide. Crispin

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS

Fuel and Oil Separators

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS

SERIES. Table 1: Available Materials Temperatures

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes

QUALITY MISTING PUMPS

Rodney Hunt. A GA Industries Company Bascule and Pelican Gates

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

Boiler Feed Booster Pump YNK. Type Series Booklet

The Pump Matic Range

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

MAYO COUNTY COUNCIL KILLALA WASTE WATER DISCHARGE LICENCE APPLICATION ATTACHMENT C

JUNG PUMPEN compli 100 MC Sewage lifting stations

Installation and Operating Procedures

SUGGESTED SPECIFICATIONS

Low-Cost Pipeline Flow Meter

AQUATOR Commercial Oil Water Separator Operating, Installation & Maintenance Manual


SECTION 9 STORM SEWER INLETS

MYERS MODELS 6VC & 6VCX

MYERS MODELS 4V AND 4VX

MYERS MODELS 4VC & 4VCX

INNOVATIVE New Generation of Backwater Valves TECHNOLOGY. Fullport Backwater Valve NEW. Access Box Model # PE 2013

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

MYERS 4VCDP. 4" Solids Handling

QUALITY MISTING PUMPS

Bacteria TMDLs for Halls Bayou November 10, 2008

MYERS MODELS 4R AND 4RX

ACO Qmax Unit size

Installation - Tank & Aerator

Sleeve Valves Energy Dissipaters

3. The working pressure shall be 145 psi and tested to 230 psi.

Pumping Station. Marisa Handajani

Above Ground Oil Tanks

Oil Interceptor Listings

2. Power Steering System

ANATOMY DISSECTION TABLES

Flygt TOP 65, 100 and 150. Turnkey pump stations

Installation, Operation & Maintenance Manual. TotlSep (TS) Series. FRP Oil/Water Separator

T95 Load Cell Assembly for Silo, Tank & Vessel Weighing and Axle Weighing

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016.

GigaBox centrifugal fans Product specific information

C.I.Agent HFF Oil Stop Valve

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

VCPA Plastic Centrifugal Fan Air Flows up to 6,000 CFM and static pressures to 10 inches w.c.

B2. Fueling Operations

Tow-Bro Unitube Sludge Removers

TECHNICAL DATA 1-1/2 (dn40)

Flood Dosed System Worksheet


Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

RAIN BIRD - AQUAGATOR AQUAGATOR INSTALLATION & TROUBLESHOOTING MANUAL

Hydro-Brake Optimum Design Tool. Step by Step Guide

VENT SILENCER PRODUCT GUIDE

Vehicle and Equipment Fueling

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

ADS FLEXSTORM CONNECTOR PIPE SCREEN (CPS) WORK INSTRUCTIONS

Commercial Fans & Dampers

Flexible Couplings & Saddles

2. Power Steering System

GRUNDFOS DATA BOOKLET. Multilift. Lifting stations 50 Hz

MYERS MODELS 4RC AND 4RCX

BEST MANAGEMENT PRODUCTS, INC. The SNOUT OIL-WATER-DEBRIS SEPARATOR SPECIFICATIONS U.S. Patent # Canadian Patent #

ATTACHMENT D (As referenced in Attachment B ) (Hydrology and Hydraulics Study)

TECHNICAL INFORMATION Bulletin

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Fact File 59 Extinguishing systems

SECTION AXIAL HVAC FANS

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100

ADS FLEXSTORM CONNECTOR PIPE SCREEN (CPS) WORK INSTRUCTIONS

MONOVAR is the energy dissipating valve.

Water Technologies. Tow-Bro Unitube Sludge Removers

Appendix C Capital Improvement Program Project Descriptions and Details

SmartCone Differential Pressure Flow Meter User Manual

Transcription:

CSO/STORMWATER MANAGEMENT Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

HYDROVEX VHV / SVHV VERTICAL VORTEX FLOW REGULATOR INTRODUCTION One of the major problems of urban wet weather flow management is the runoff generated after a heavy rainfall. During a storm, uncontrolled flows may overload the drainage system and cause flooding. Due to increased velocities, sewer pipe wear is increased dramatically and results in network deterioration. In a combined sewer system, the wastewater treatment plant may also experience significant increases in flows during storms, thereby losing its treatment efficiency. A simple means of controlling excessive water runoff is by controlling excessive flows at their origin (manholes). John Meunier Inc. manufactures the HYDROVEX VHV / SVHV line of vortex flow regulators to control stormwater flows in sewer networks, as well as manholes. The vortex flow regulator design is based on the fluid mechanics principle of the forced vortex. This grants flow regulation without any moving parts, thus reducing maintenance. The operation of the regulator, depending on the upstream head and discharge, switches between orifice flow (gravity flow) and vortex flow. Although the concept is quite simple, over 12 years of research have been carried out in order to get a high performance. The HYDROVEX VHV Vertical Vortex Flow Regulator (refer to Figure 1) is manufactured entirely of stainless steel, and consists of a hollow body (1) (in which flow control takes place) and an outlet orifice (7). Two rubber "O" rings (3) seal and retain the unit inside the outlet pipe. Two stainless steel retaining rings (4) are welded on the outlet sleeve to ensure that there is no shifting of the "O" rings during installation and use. 1. BODY 2. SLEEVE 3. O-RING 4. RETAINING RINGS (SQUARE BAR) 5. ANCHOR PLATE 6. INLET 7. OUTLET ORIFICE HYDROVEX VHV VERTICAL VORTREX FLOW REGULATOR FIGURE 1 - VHV HYDROVEX SVHV SPECIAL VERTICAL VORTEX FLOW REGULATOR FIGURE 1 SVHV 1. BODY 2. SLEEVE 3. O-RING 4. RETAINING RINGS (SQUARE BAR) 5. ANCHOR PLATE 6. INLET 7. OUTLET ORIFICE

ADVANTAGES OF THE HYDROVEX FLOW REGULATORS The HYDROVEX VHV / SVHV line of flow regulators is manufactured entirely of stainless steel, making them durable and corrosion resistant. Having no moving parts, they require minimal maintenance. The geometry of the HYDROVEX VHV / SVHV flow regulators allows a control equal to an orifice plate, having a cross section area 4 to 6 times smaller. This decreases the chance of blockage of the regulator, due to sediments and debris found in stormwater flows. Installation of the HYDROVEX VHV / SVHV flow regulators is quick and straightforward and is performed after all civil works are completed. Installation requires no special tools or equipment and may be carried out by any contractor. Installation may be carried out in existing structures. HYDROVEX SELECTION CRITERIA VHV OR SVHV Figure 2 is a graphical representation of the head vs. discharge range for various VHV or SVHV regulators. This curve is a function of the maximum upstream static water pressure (head) and the discharge. As may be seen from the two curves, the SVHV models have larger cross-sectional flow areas than the VHV's for a given discharge and head. Model selection is performed by determining the maximum design flow at the manhole outlet and the maximum design head at the insert of the manhole outlet pipe. Each regulator is applicable for operation within a range of head and discharge values, as illustrated by the graph. Using this information one can refer to Figure 2 and determine which model is applicable. All selections should be verified by John Meunier Inc. personnel prior to fabrication FIGURE 3: DISCHARGE CURVE FOR A HYDROVEX 100 SVHV-1-100 AND A 4" Ø ORIFICE PLATE

VHV Vertical Vortex Flow Regulator FIGURE 2 - VHV

SVHV Vertical Vortex Flow Regulator FIGURE 2 - SVHV

DIMENSIONING OF MANHOLES Most HYDROVEX models may be installed in a standard 36-inch diameter manhole. All models may also be installed in a rectangular manhole with a minimum dimension of 36 inches (24 inch diameter or rectangular manhole may be used for smaller models). NOTE that in the case of a square manhole, the outlet flow pipe must be centered on the wall to ensure enough clearance for the unit. A minimum clearance "H" should be established between the floor of the manhole and the invert of the outlet pipe to install the regulator. Figure 4 gives the various dimensions required for a given regulator. HOW TO SPECIFY THE TYPE OF HYDROVEX REGULATOR In order to specify a HYDROVEX regulator, the following parameters must be defined: The model number (ex: 100-VHV-1) The diameter and type of outlet pipe (ex: 6" diam. SDR 35 or 8" diam. RCP) The desired discharge (ex: 50 l/s or 1.76 CFS) The upstream head (ex: 2 m or 6.56 ft.) * The manhole diameter (ex: 36" diam.) The minimum clearance "H" (ex: 10 inches) The material type (ex: 304 s/s, 11 Ga. standard) PLEASE NOTE THAT WHEN REQUESTING A PROPOSAL, WE SIMPLY REQUIRE THAT YOU PROVIDE US WITH THE FOLLOWING: project design flow rate pressure head chamber s outlet pipe diameter NOTE: Upstream head is defined as the difference in elevation between the maximum upstream water level and the invert of the outlet pipe where the HYDROVEX flow regulator is to be installed. Typical VHV in factory VHV with air vent for minimal slopes

FLOW REGULATOR TYPICAL INSTALLATION IN CIRCULAR MANHOLE FIGURE 4 ( MODEL VHV ) Model Number Regulator Diameter A (mm) Manhole Diameter B (mm) Outlet Pipe C (mm) Clearance H (mm) 50VHV-1 203 600 150 127 75VHV-1 280 600 150 152 100VHV-1 356 900 150 203 125VHV-2 330 900 200 203 150VHV-2 406 900 200 229 200VHV-2 533 1200 254 305 250VHV-2 660 1200 300 356 300VHV-2 787 1600 375 406 350VHV-2 914 1800 375 508 clearance H relates to the diameter indicated in the chart. If the outlet diameter decreases, the H clearance will also decrease.

FLOW REGULATOR TYPICAL INSTALLATION IN CIRCULAR MANHOLE FIGURE 4 ( MODEL SVHV ) Model Number Regulator Diameter A (mm) Manhole Diameter B (mm) Outlet Pipe C (mm) Clearance H (mm) 25 SVHV-1 152 600 150 152 32 SVHV-1 178 600 150 152 40 SVHV-1 229 600 150 152 50 SVHV-1 279 600 150 152 75 SVHV-1 432 900 150 279 100 SVHV-2 356 900 200 254 125 SVHV-2 432 900 200 305 150 SVHV-2 559 1200 250 356 200 SVHV-2 686 1600 300 457 250 SVHV-2 864 1800 375 559 300 SVHV-2 1041 2400 375 660 350 SVHV-2 1194 2400 375 711 clearance H relates to the diameter indicated in the chart. If the outlet diameter decreases, the H clearance will also decrease

FLOW REGULATOR TYPICAL INSTALLATION IN SQUARE MANHOLE FIGURE 4 ( MODEL VHV ) Model Number Regulator Diameter A (mm) Manhole Min. width B (mm) Outlet Pipe C (mm Clearance H (mm) 50VHV-1 203 600 150 127 75VHV-1 280 600 150 152 100VHV-1 356 600 150 203 125VHV-2 330 600 200 203 150VHV-2 406 600 200 229 200VHV-2 533 900 254 305 250VHV-2 660 900 300 356 300VHV-2 787 1200 375 406 350VHV-2 914 1200 375 508 clearance H relates to the diameter indicated in the chart. If the outlet diameter decreases, the H clearance will also decrease.

FLOW REGULATOR TYPICAL INSTALLATION IN SQUARE MANHOLE FIGURE 4 ( MODEL SVHV ) Model Number Regulator Diameter A (mm) Manhole Min. width B (mm) Outlet Pipe C (mm) Clearance H (mm) 25 SVHV-1 152 600 150 152 32 SVHV-1 178 600 150 229 40 SVHV-1 229 600 150 229 50 SVHV-1 279 600 150 152 75 SVHV-1 432 600 150 229 100 SVHV-2 356 600 200 178 125 SVHV-2 432 600 200 229 150 SVHV-2 559 600 250 254 200 SVHV-2 686 900 300 330 250 SVHV-2 864 900 375 406 300 SVHV-2 1041 1200 375 508 350 SVHV-2 1194 1200 375 610 clearance H relates to the diameter indicated in the chart. If the outlet diameter decreases, the H clearance will also decrease.

FV SVHV (mounted on sliding plate) VHV-1-O (typical model with odor control inlet) FV - VHV (mounted on sliding plate with odor control inlet) VHV with Gooseneck assembly in existing chamber without minimum release at the bottom Typical chamber for VHV-SVHV with Gooseneck

Typical roof drain chamber VHV used as roof drain in building s piping INSTALLATION The installation of a HYDROVEX regulator may be undertaken once the manhole and piping is in place. Installation consists of simply fitting the regulator into the outlet pipe of the manhole. John Meunier Inc. recommends the use of a lubricant on the outlet pipe, in order to facilitate the insertion and orientation of the flow controller. MAINTENANCE HYDROVEX regulators are manufactured in such a way as to be maintenance free; however, a periodic inspection (every 3-6 months) is suggested in order to ensure that neither the inlet nor the outlet has become blocked with debris. The manhole should undergo periodically, particularly after major storms, inspection and cleaning as established by the municipality GUARANTEE The HYDROVEX line of regulators are guaranteed against both design and manufacturing defects for a period of 5 years. Should a unit be defective, John Meunier Inc. is solely responsible for either modification or replacement of the unit, at their discretion. Head Office 4105 Sartelon St-Laurent (Quebec) Canada H4S 2B3 Tel. : 514-334-7230 www.johnmeunier.com Fax : 514-334-5070 cso@johnmeunier.com Ontario Office 2000 Argentia Road, Plaza 4, Unit 430 Mississauga (Ontario) Canada L5N 1W1 Tel. : 905-286-4846 www.johnmeunier.com Fax : 905-286-0488 ontario@johnmeunier.com Revised: 2006-07-25