Datasheet VHF Moisture Sensor

Similar documents
Manual Rotation Meter PCE-AT 5

Manual KREBS Viscometer PCE-RVI 5

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Stainless steel(compensation) DN25, 40, Flange Standard GB/T Others DIN,ANSI,JIS Thread Standard BSPP(male) Others BSPP(Female),NPT.,etc. A

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

OC Automation Converters Series. Electronic Industries Alliance (EIA) interface converter series for serial communication devices

mass flowmeter for compressed air

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

Thermal Gas Mass Flowmeter Series TMF-300

Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Level MONITORING. Continuous Level Measurement ILS

LBTC Series Positive Displacement Rotary Vane Flow Meters

Smart & Simple Telematics

Magnetic-inductive flow meter for hazardous areas

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Model TUR-200D Turbine Flowmeter

Feed material Measuring range* Sieving motion Max. batch / feed capacity powders, bulk materials, suspensions 25 µm mm throwing motion with angu

Liquid Turbine Flow Meter OwnerÊs Manual

Range of Ultrasonic Flowmeters.

SRT1000 Series THERMAL FLOWMETER

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

4-20mA, pulse with HART or pulse with RS485 are selectable. No moving parts, no abrasion, non-wearing parts inside, fully welded SS304

ATM SERIES THREE PHASE MULTI - TURN

VLM20 In-line Vortex Flowmeter

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

OPTIMASS 3000 Technical Datasheet

ULTRASONIC FLOWMETER / HEATMETER

F6700 ELECTROMAGNETIC METER

Pressure transducer DMU 01K Compact version

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

Level switches (two-term level controllers) ERH-xx-04,-06,-07,-16,-16.1 Description

SonoMeter 30 Energy Meters

WATER & IRRIGATION METERS QUALITY FLOW METERS FOR THE AGRICULTURE AND AQUIFER MANAGEMENT. Quality Engineered Systems

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Flow meter Type Recordall (RCDL)

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

PCE-CS 300. Crane Scales up to 300 kg ( 661 lb)

Miniature multipoint thermocouple Model TC96-M

LC OVAL GEAR FLOWMETER

Mobrey MSM400 Ultrasonic sludge density measurement system

MagFlux Q 8200 Series

SonoMeter 30 Energy Meters

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

Ultrasonic Flow Meter Series Smart-IN US. Features. Description

COSASCO ACCESS FITTING ASSEMBLIES

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

Series description: Wilo-Stratos

Superstatic 440. Static Heat- and Cooling Meter. Application

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

CORONA E ELECTRONIC METER MULTI-JET

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

KYDM-F Series Magnetostrictive Transducers for Oil & Chemical

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Swing Check Valve AKR/AKRS. PN DN 80/80 bis 300/250 Pressure Seal Design Flanged/Butt Weld Ends. Type Series Booklet

SINGLE-TURN AND MULTI-TURN ELECTRIC ACTUATORS

Magnetic Float Level Indicator

Hot Tap Insertion Vortex

OMNICOMM FUEL-LEVEL SENSORS FUELLING YOUR BUSINESS

Options guide. Electromagnetic flowmeters. M9xx

DIAMOND POINT VIBRATING PROBES

VA-7000 SERIES ACTUATOR

OPTIMASS 2000 Technical Datasheet

STEEMCO Flowmeter for Steam

M Series Floating Metal Seat Ball Valve

Manual Actuator. MA Manual Gearbox Force Transmission via Planetary Gear Torque Range up to 250 Nm. Type Series Booklet

LS Rotary Piston flow meter

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

GS.No.GBN120E 9. Liquid. Gas. High Performance Coriolis Flowmeters GENERAL

Manual Thickness gauge PCE-CT 30

RUBBER SLEEVE KNIFE GATE VALVE

Swing Check Valve AKR/AKRS. PN DN 80/80 to 300/250. Type Series Booklet

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

압력트랜스미터 Model ADP9000 Series

Flow Measurement SITRANS F C

ORIMAS Mass Flowmeter

Forged 3 Piece Trunnion Mounted Ball Valves Series MS

DY-LWGY Liquid turbine flow meter

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

RUBBER SLEEVE KNIFE GATE VALVE

Datasheet for MATRE BLADDER TANK FOAM PROPORTIONERS

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

WP37 & HT37 User Manual

Supercal 539 Universal compact heat meter

VIM20 Vortex Insertion Flowmeter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

HYDRUS ULTRASONIC METER

tprime TM Series 280T

1.4 SCT Temperature sensor

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

mass flowmeter for compressed air

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

NT-500 Technical Support Guide. For use by qualified company approved Technicians

Flow VA 550 / 570. DVGW tested. Flow.

SITRANS FC. Flowmeter SITRANS FC410

Transcription:

PCE-MWM 220 Datasheet VHF Moisture Sensor EN PCE Instruments UK Ltd. South Point Business Park Ensign Way Units 12/13 SO31 4RF Southampton United Kingdom Tel: +44 ( 0 ) 2380 987 03 0 info@industrial-needs.com www.pce-instruments.com/english PCE Americas Inc. 711 Commerce Way Suite 8 FL-33458 Jupiter United States Tel: +1 (561) 320-9162 info@pce-americas.com www.pce-instruments.com/us

Application The frequent and important peculiarity which should be considered in any kind of industry and production is that the material used in the production process has got a certain amount of moisture in it. It goes not only about bulk materials (such as sand, rubble, ore, gravel etc), but about liquids as well (oil, fuel oil, coal-water slurry fuel (CWSF), petroleum etc). Though all the versions of the moisture meter have got similar structure each versions performs its own function. The device consists of an electronic unit and a sensor. The flanges of the sensor which is made as a pipe section are made of stainless steel. A probe which is inside the pipe is made as a flat-topped stick of stainless steel of the same grade. Because of the probe being equipped with a thermocouple, it is possible to carry out temperature control. The length of the pipe section with the flanges is 400 mm. The moisture meter is available in several versions with different nominal bore: DN 50, DN 80 and DN 125 mm, and different allowable pressure: PN 1.6 (16 atm); РN 2.5 (25 atm); РN 4.0 (40 atm); РN 6.3 (63 atm) and РN 10.0 (100 atm). Product features All the parameters can be adjusted depending on the needs of the customer. Due to the material the moisture meter is made of the device is resistant to corrosion, abrasive materials, mechanical stress. It alos allow suing the sensor for emasuremts at very high temperatures (145 C). On request it is also possible to provide the device operating at the temperatures of 350 C. The temperatures range can be even higher, due to the use of ceramic plates and high-temperature alloys. The electronic unit can have an explosion-proof enclosure as well as the general purpose version. Moisture meters for liquid materials are used in boiler installations, water-dosing and diesel oil emulsion dispersion systems. The scope of supply can include the control cabinet to operate the valves regulating water feed. The moisture meter for liquid materials has a processing unit with RS232/RS485 interfaces (can be easily included into ACS-automatic control systems); and its supply package includes software suitable for Windows, as well as the control cabinet to operate the valves regulating water feed. Moisture meters for liquid materials are used in boiler installations, water-dosing and diesel oil emulsion dispersion systems. The scope of supply can include the control cabinet to operate the valves regulating water feed. The moisture meter for liquid materials has a processing unit with RS232/RS485 interfaces (can be easily included into ACS-automatic control systems); and its supply package includes software suitable for Windows, as well as the control cabinet to operate the valves regulating water feed.

Technical specification Measurement range 0... 100 % Limits of permissible absolute error of the Δ= 0.035 +0.05 W measurements results of the mass fraction (see Note 1) of water Temperature measurement range -40... +150 C Range of working temperatures -20... +120 C -20... +345 C Operation mode continous continous operation Measurement period 1 s Voltage supply - Rated / - Allowable 24 (18... 36) VDC Consumption current, not more than 200 ma Warm-up time at start-up 90 min RS 485 Modbus RTU, 4-20 ma [RS485: Output max. cable length 1,000 m; 4-20 ma: max. cable length 100 m (max. cable length to SPS unit)] Pressure PN 6... PN 40 (... 100 bar 10 MPa) DN 50, DN 80, DN 100 or DN 125 Dimension of the sensor (depending on the variant) / length allways 400 mm Overall dimension of the electric unit 255 х 170 x 60 mm Note 1 Moisture W [%] Absolute error ΔW [%] 0... 0,3 0,3 0,3... 3 0,1 3... 7 0,2 7... 10 0,3 10... 20 0,5 20... 40 1,0 40... 100 2,5

Technical drawing PCE-MWM 220 DN50 PCE-MWM 220 DN80 DE

Application pictures

1 Ordering code PCE-MWM 220-XXX-XX(-XX-XX) Diameter -050 version pipe diameter DN50-080 version pipe diameter DN80-125 version pipe diameter DN125 Pressure resistance -06 PN6 (only version DN125) -16 PN16 (only version DN80) -25 PN25 (only version DN50 & DN80) -40 PN40 (only version DN50 & DN80) High temperature version (optional) -HT Ausführung temperaturbeständig bis +345 C Explosion proof (optional) -EX Electronics in explosion proof housing Ex d II B T5 Ordering example PCE-MWM 220-50-25-HT-EX - VHF moisture sensor PCE-MWM 220 - Version pipe diameter DN50 - PN25 - High temperature version upto +345 C - Explosion proof Ex d II B T5