Protector Glove Boxes.

Similar documents
PROTECTOR. Glove Boxes. Controlled Atmosphere and Multi-Hazard

Protector Controlled Atmosphere Glove Boxes

PRECISE. Glove Boxes

Precise Glove Boxes & XPert Weigh Boxes

Protector Multi-Hazard Glove Box

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

PROTECTOR FIBERGLASS ENCLOSURES

PHARMACY Products. Compounding Aseptic Containment Isolator (CACI) A level of safety that is built in, not bolted on. Underwriter Laboratories Listed

GLOVE BOX GALLERY. Inert Gases. Temperature and Humidity

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

WORKSTATION PICTURE SHOWS PRODUCT WITH OPTIONS

SP/DP. * LABmaster pictured above shown with optional features

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

PHARMACY Products. Compounding Aseptic Isolator (CAI) Positive pressure sterility assurance barrier isolator for complete product protection.

MODEL NUMBER NOMENCLATURE. The model described above is a Side Access Housing, 4,000 CFM, 2 stages PX1224 cells, epoxy coated construction.

BSC-1100IIA2-X is designed to meet the operating principles:

CLASS II BIOSAFETY CABINET

SterilSHIELD. Designed for Aseptic Compounding of Non-Hazardous Pharmaceuticals. SterilSHIELD Barrier Isolator (positive pressure)

MODEL SAFETY & INSTRUCTION MANUAL

A viewscreen top hinge allows full opening for loading of instrumentation or equipment.

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

Compounding Safety Solutions.

<800> Hazardous Drugs Handling in Healthcare Settings. Jeanne Sun, PharmD

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

As ept i c I s olator s

Ventilated Balance Enclosures

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Appendix C: Biosafety Cabinet Specifications C-2. Product Service

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

LAMINAR AIRFLOW EQUIPMENT

Biological Safety Cabinet. Feature & HEPA-filter efficiency

STANDARD GLOVEBOX WORKSTATIONS

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

OmniAire Portable Air Cleaner OA1200PAC

Ducted HEPA filter units for highly sensitive areas

I-Lab Glovebox Systems QUALITY YOU CAN COUNT ON. Inert s line of I-Lab Glovebox Systems are designed as an economical solution for inert research appl

PCR Laminar Flow Cabinets

SECTION HVAC AIR CLEANING DEVICES

FASTER ChemFAST. Laboratory Fume Cupboards PROTECTION, SAFETY, RELIABILITY. AND MORE.

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

2008 PCP COMPOUND APPLICATIONS GUIDE

Appendix C: Biosafety Cabinet Specifications C-1. Product Service

PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

Requires Ductwork and Blower

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

TOTALINE ELECTRONIC AIR CLEANERS

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Fume Hoods. Selection Guide. Fume Hoods. Accessories & Options. Clean Benches. Ductless Fume Hoods. Description Filter Work Surface Page.

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

TECHINCAL DESCRIPTION BIO BAN

Gas Purification Systems: Z Series

BIOSAFETY CABINETS. SURFACE WIDTH: 120cm - 48

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Technical Specification Number S121 for Insulating Oil Purification Plant, Type E rev Q CONTENTS

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

Biological Safety Cabinet

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

NU-430/435 CLASS II, TYPE B2 BIOLOGICAL SAFETY CABINETS

Class II biological safety cabinets

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

Protector Demonstration Hoods

Ducting & Ventilation Components

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Best Products. Best Performance. Best Protection.

HORIZONTAL LAMINAR FLOW HOOD FLO

OmniAire 2200 Operations and Maintenance Manual

Air Boss M-Series Media & Adsorption Air Cleaner

HEPA AIR FILTRATION SYSTEM

TITAN, ATLAS & SIRIUS SMALL, PORTABLE. economical cabinets. with low energy consumption

External Dimensions (mm) Internal Dimension (mm) Material. Side Panel Pre-filter Main Filter Air Speed Noise Glass Door

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

Vari-Disk Service. Inline disc filters to meet your needs. Inlet and outlet connectors. Filter housing

Sterility Test Isolator Design, Construction and Examples

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

Installation, Operations and Maintenance Guide

GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007

(Class II Type A2 & B2)

High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

Comply with the above specifications? Yes No

Differentially Pumped Rotary Platform (DPRP) Instructions

PHOENIX MINI-GUARDIAN

Angelantoni Life Science. Microbiological safety cabinets Class II. SterilSafe Series

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

General. Technical Bulletin: ACCESSORY INFORMATION

USP 800: Now What Do We Have To Do?!

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

SPH General Manual 400 Series

CHAPTER 7 GLOVEBOX FILTRATION

High vacuum transformer oil purification (HVTOPS) & Dielectric OIL Purifier System (DOPS)

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

Transcription:

Protector Glove Boxes www.labconco.com

Glove Boxes, An Overview The purpose of a glove box is to provide a physical barrier. Depending on the type of glove box, the physical barrier may be: Isolating a sensitive material from outside environmental contamination. Protecting the operator from hazardous materials.

What is a Glove Box? A sealed enclosure where all handling is through glove ports. Used for personnel and/or product protection.

Selecting the right type of Glove Box Choose the Controlled Atmosphere Glove Box when an inert atmosphere is needed. Choose the Multi-Hazard Glove Box when a ventilated, particulate-free atmosphere and filtered exhaust is needed.

Protector Controlled Atmosphere Glove Box Maintains an inert atmosphere, i.e. nitrogen or argon. Protects air-sensitive materials, i.e. inorganics, organics, organometallics and biochemicals. Protects materials from oxygen and moisture contamination.

Controlled Atmosphere Glove Box Transfer Chamber Allows quick and easy material transfer to and from main chamber. Achieves deep vacuum level of -29" Hg. 30" of mercury is considered absolute vacuum

Controlled Atmosphere Glove Box Main Chamber Allows easy manipulation of materials inside a sealed chamber using gloves. Operates within a positive or negative pressure range of -6 to +6 inches of water. Inches of water is a much smaller pressure measurement than inches of mercury. 1" H 2 O = 0.073" Hg

Controlled Atmosphere Glove Box Operation Basics The Main Chamber and Transfer Chamber are connected to an inert compressed gas source and vacuum pump with dedicated tubing. Plumbing lines allow chambers to be evacuated, then filled with pure gas. By manipulating the gas pressures inside the chambers, oxygen and/or moisture contaminants are replaced with a pure gas atmosphere. Glove Box Inlet Connection Glove Box Outlet Connection Transfer Chamber Inlet Connection Transfer Chamber Outlet Connection

Controlled Atmosphere Glove Box Control Features Manual Valves for Models 5060000 and 5061000. Four manual valves control chamber pressures. These valves control evacuation and gas filling operations.

Controlled Atmosphere Glove Box Main Chamber Electronic Controls LED Display for models 5070000 and 5070100 Switches keep main chamber pressure between set points. Alarm indicates when main chamber pressure exceeds safe limits.

Controlled Atmosphere Glove Box Main Chamber Electronic Controls For models 5070000 and 5070100 Pressure controlled foot pedal and pressure override switches allow user to increase or decrease operating pressure.

Controlled Atmosphere Glove Box Transfer Chamber Electronic Controls For models 5080000 and 5080100 Indicates the number of evacuation and fill cycles selected and completed Manual evacuation and fill switches Selects number of cycles Cycle start and cancel switches Vacuum level switch selects level of vacuum for each cycle Gas Source switch (selects source of fill gas)

Controlled Atmosphere Glove Box AtmosPure Regenerative Drying Train Option Factory installed. Includes gas purifier column, blower and electronic regeneration panel. Reduces water contamination to 5 ppm, and oxygen to 1 ppm. Continuous operation removes oxygen and moisture from the glove box atmosphere by re-circulating it through the train. Close-up of AtmosPure Drying Train

Controlled Atmosphere Glove Box One piece, molded fiberglass or stainless steel liner Laminated safety glass angled 10 degrees One-piece, molded neoprene window gasket 8" diameter glove ports Two interior electrical receptacles Easy access circuit breakers Standard Features 30" Neoprene Gloves included 30-watt fluorescent lamp One exterior 3-wire electrical receptacle Large transfer chamber Control switches and pressure gauges Inner and outer transfer chamber doors Four manual valves for gas inlet and outlet control

Controlled Atmosphere Glove Box Standard Features All Protector Controlled Atmosphere Glove Boxes are factory tested with a helium mass spectrometer while pressurized with helium at 5" water gauge. No leaks > 1x10-6 cc/sec or 31cc/year. Large viewing window is removable for loading bulky apparatus. Pressure relief bubbler manometer prevents glove box damage from extreme high or low pressures.

Controlled Atmosphere Glove Box Bubbler/Manometer Basics Bubbler included with Controlled Atmosphere Glove Box. Bubbler prevents over or under pressure extremes inside the main chamber. maximum pressurization is + or -6" H 2 O U-tube is filled with vacuum pump oil, which moves within the column releasing excess pressure to prevent glove box damage.

Controlled Atmosphere Glove Box Accessories Interior Port Cover Exterior Port Cover Drying Train Fixed and Mobile Base Stands

Controlled Atmosphere Glove Box Accessories Interior Shelves Seamless Neoprene, Butyl, and Hypalon Gloves available in two sizes Rotary Vane Vacuum Pumps

Controlled Atmosphere Glove Box Accessories Optional Sliding Transfer Tray for loading materials into the glove box Optional Mini Transfer Chamber for left side

Controlled Atmosphere Glove Box Market Applications Hydrophilic chemicals. Organometallics. Alternate energy cells, i.e. lithium batteries Metabolic research Oxygen- or moisture-sensitive compounds, i.e. sodium Electronic components.

Glove Boxes can be Super Sized! Double Controlled Atmosphere Glove Boxes Greater working area. Control system costs do not double. Available in stainless steel.

Protector Multi-Hazard Glove Box Provides a physical barrier to protect operator from exposure to potentially dangerous particulates. Inlet air is HEPA* filtered providing a Class 100 environment. Air exiting the box is HEPA filtered to remove particulates. Adjustable air flow volumes from 0-60 cfm. *High efficiency particulate air

Multi-Hazard Glove Box HEPA Filters (High Efficiency Particulate Air) Disposable filter of boron silicate microfibers cast into a thin sheet. Media is folded to maximize its surface area. Sometimes aluminum separators are used between the folds. Retains airborne particles and microorganisms, but gases pass freely through filter. Filter frame Continuous sheet of Filter Medium

Multi-Hazard Glove Box Air Filtration System Prefilter HEPA intake filter Primary exhaust HEPA filter Optional secondary exhaust filter (HEPA or Carbon) Blower

Multi-Hazard Glove Box Standard Features One-piece, molded fiberglass or stainless steel liner Laminated safety glass angled 10 degrees One-piece, molded neoprene gasket 8 diameter glove ports Two interior electrical receptacles Inlet and outlet HEPA filters 30" long Neoprene Gloves included Built-in blower Pressure differential gauge Large transfer chamber Control switches Inner and outer transfer chamber doors Blower speed knob

Multi-Hazard Glove Box Accessories Carbon Exhaust Filter HEPA Inlet or Exhaust Filter Interior Shelves

Multi-Hazard Glove Box Accessories Interior Glove Port Cover Base Stand Mobile Base Stand Exterior Glove Port Cover

Multi-Hazard Glove Box Applications Chemical and biochemical research involving: Non-biohazardous microorganisms. Chemical powders, drugs, proteins and enzymes. Asbestos; Carcinogenic materials. Crime scene evidence. Low level radioactive materials.

Multi-Hazard Glove Box or Class II Safety Cabinet? Multi-Hazard Glove Boxes are designed to contain toxic particulates, but not biohazardous microorganisms. Biological Safety Cabinets are designed to contain biohazards, such as bacteria and viruses.

Multi-Hazard Glove Box versus Class III Biosafety Cabinet The Multi-Hazard Glove Box is designed to contain toxic, but not biohazardous, particulate contaminants. Room Air HEPAfiltered Air Unfiltered Air Transfer chamber does not sterilize material coming out of the glove box. Class III Biosafety Cabinet has a double door autoclave transfer chamber to sterilize all material being removed. Only sterilization ensures the destruction of all biohazard sources. Class III Cabinet Airflow

Protector Combination Glove Box Handles both atmospheresensitive materials or hazardous materials. Converts quickly from controlled atmosphere function to vented hazardous material operation.

Protector Combination Glove Box Closing two internal valves converts the box to a leak-tight glove box ready for controlled atmosphere procedures. Opening the internal valves allows the integral blower to pull room air through inlet and exhaust HEPA filters.

User Group The American Glove Box Society is a not-for-profit organization whose members are glove box users. AGS has developed guidelines for glove box construction. These guidelines recommend specific design and construction features for glove boxes. ags@gloveboxsociety.org