WLI Medium Voltage Switchgear Renewal Parts

Similar documents
www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

S&C Mini-Rupter Switches Application The Standard Mounting Arrangement Scheme for S&C Mini-Rupter Switches Typical ED, reduced from full 11 size.

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Description Notes. 1. Parts are identified by Breaker Type in the top row and Part Description in the left column.

Medium Voltage Metal-Enclosed Switches

A200 NEMA Contactors and Starters A200

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Cable-Operated Disconnect Switches. Accessories

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Medium Voltage Metal-Enclosed Switches

RBA Catalog Numbers and Information

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Outdoor Padmount Switching Products

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

Copper Double Break Switch

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Type ICX Interchangeable Cutout kv Outdoor Distribution Cutout Product Bulletin 1VAG DB

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

Product Specifications for Phase Over Phase GOABS(r)

www. ElectricalPartManuals. com

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Cutler-Hammer. January 2001

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

PT Medium voltage fuses for potential and small power transformers

Type ICX Outdoor open type cutout

500 and 690 V a.c. am NH fuse links

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

Product Selection 3-Pole Contactors

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Copper Vertical Break Switch kv A.

Aluminum Vertical Break Switch kv A.

Ampgard medium voltage motor control renewal parts

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

SWITCHGEAR DIVISION PRODUCT PROFILES

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Medium Voltage Outdoor Apparatus Portfolio 2009

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

VOYTEN ELECTRIC & ELECTRONICS

K-Limiter high ampere Companion II fuse

SPECIFICATION BULLETIN

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Specifications. S&C Mini-Rupter Switches Indoor Distribution (4.16 kv through 25 kv) Manually Operated Styles

WARNING. TYPE PSI/II PAD-MOUNT SWITCHGEAR with Non-Loadbreak Fuse Mountings 15kV 25kV INSTRUCTIONS. Qualified Persons. For Installation and Operation

FP AUTOMATIC METAL-ENCLOSED SWITCHGEAR

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Product Specifications for Aluminum Vertical Break Switches

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

5H KA, RMS C/L Recommendations for Stock POLE UNIT PARTS ARC CHUTE DETAILS. Core, Fig. 17, It.

Westinghouse Breaker Maintenance Manual READ ONLINE

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Specifications. S&C Manual PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv)

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

I.L C Instructions for Type WLI and WVB Metal Enclosed Switchgear (MVS) 5.0 kv, 15.0 kv, 25.8 kv, and 38.0 kv

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Instructions for AMPGARD 400A medium voltage starter

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

INDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

NEMA Contactors & Starters (Freedom)

SPECIFICATIONS. S&C Alduti-Rupter Switches with Power Fusesa SPECIFICATION BULLETIN Indoor Distribution (4.8 kv and 13.

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Specifications. S&C Alduti-Rupter Switchesa Indoor Distribution (4.8 kv through 34.5 kv) Conditions of Sale SPECIAL TO THIS PRODUCT: How to Order

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

100 / 110 DRYWELL FUSE SPECIFICATION

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Unitized Quick Install Switches for Transmission Applications

Specifications. S&C Source-Transfer PMH Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) With Micro-AT Control. Conditions of Sale

Transcription:

Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts

Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement Capabilities List ➀ Switch Pole Assembly ➁ Arcing Contact Assembly ➂ ➃ ➇ ➈ ➉ Drive Rod Link (Polyester) Drive Rod Link (Porcelain) (Not Shown) Switch Barrier Assembly Fuse Barrier Assembly Open Close Indicator/Interlock Cam m Fuse Live Parts Kit

Page 3 Replacement Capabilities ➀ Switch Pole Assemblies Part Description Style Number Quantity per Switch Switch Pole Assemblies Three-pole set includes main and flicker blades, break jaws, arc chutes and adjustment tool kit. List Price Each (60 kv BIL or 95 kv BIL) 5 and 15 kv 600 amperes 5 and 15 kv 1200 amperes 7278A27G01 7278A27G02 $10130 13220 (110 kv BIL) 15 kv 600 amperes 15 kv 1200 amperes 7278A27G03 7278A27G04 10520 13600 (125 kv BIL or 150 kv BIL) 25 and 38 kv 600 amperes 7278A27G05 14400 ➁ Arcing Contact Assemblies Arcing Contact Assemblies Three-pole set includes flicker blades and arc chutes. This kit is not required when switch pole assemblies above are ordered. (60 kv BIL or 95 kv BIL) 5 and 15 kv 600 amperes 5 and 15 kv 1200 amperes 7278A27G06 7278A27G07 2540 3320 (125 kv BIL or 150 kv BIL) 25 and 38 kv 600 amperes 7278A27G08 3600 ➂ Drive Rod Link (Polyester) Drive Rod Link (polyester, set of three) 5 kv (60 kv BIL) 15 kv (95 kv BIL) 15 kv (110 kv BIL) 25 and 38 kv (125 kv BIL or 150 kv BIL) 7278A27G09 7278A27G10 7278A27G11 7278A27G12 550 590 650 ➃ Drive Rod Link (Porcelain) Drive Rod Link (porcelain) (set of three) 5 kv (60 kv-bil) 15 kv (95 kv-bil) 25 and 38 kv (125 kv-bil or 150 kv-bil) 7278A27G13 7278A27G14 7278A27G15 4350 5350 6350 ➄ Insulators Polyester Porcelain Insulators (one each) (60 kv-bil) 5 kv Glass Polyester 5 kv Porcelain (95 kv-bil) 15 kv Glass Polyester 15 kv Porcelain (110 kv-bil) 15 kv Porcelain (125 kv-bil or 150 kv-bil) 25 and 38 kv Porcelain 4892A97H03 548D224G07 4892A97H04 548D235G07 548D236G07 1707C41G01 as required as required as required as required as required as required 100 440 100 500 540 1080

Page 4 Replacement Capabilities, Continued ➅ Removable Handle Part Description Style Number Quantity per Switch List Price Each Removable Handle All Ratings 7274A49H01 $ 90 ➆ Switch Spring Mounting Assembly Switch Spring Mounting Assembly 5-15 kv 40 ka Fault Close 5 kv 61 ka Fault Close 15 kv 61 ka Fault Close 25 kv 20 ka Fault Close 25 kv 40 ka Fault Close 25 kv 60 ka Fault Close 38 kv 20 ka Fault Close 38 kv 30 ka Fault Close 7278A27G16 7278A27G17 7278A27G18 7278A27G19 7278A27G20 7278A27G21 7278A27G22 7278A27G23 1000 1500 1500 1050 1500 ➇ and ➈ Switch or Fuse Barrier Assembly Switch Barrier Assembly 5 and 15 kv 25 and 38 kv 7278A27G24 7278A27G25 1540 3200 Fuse Barrier Assembly 15 kv 25 and 38 kv 7278A27G26 7278A27G27 1540 3200 ➉ Open Close Indicator/Interlock Cam Open-Close Indicator/lnterlock Cam for Lock open/close or Lock open only 220C934H01 250 Open-Close Indicator/lnterlock Cam for Lock close only 220C934H02 250 k Auxiliary Switch Assembly Auxiliary Switch Assembly (5 NO and 5 NC Contacts) 7278A27G28 770

Page 5 Replacement Capabilities, Continued l Switch Adjustment Tool Kit Part Description Style Number Quantity per Switch List Price Each Switch Adjustment Tool Kit All Ratings 221C113G01 $ m Fuse Live Part Kit Fuse Live Part Kit Non Disconnect (Three-Phase Top and Bottom) RBA200 5 15 kv RBA400 5 15 kv RBA200 25 38 kv RBA400 25 38 kv CLE-1 5 15 kv CLE-2 5 15 kv CLE-3 5 15 kv CX 5 15 kv CXN-1 5 15 kv (Single Barrel 3 inch Dia.) CXN-1 5 15 kv (Single Barrel 4 inch Dia.) CXN-2 5 15 kv (Double Barrel 3 inch Dia.) CXN-2 5 15 kv (Double Barrel 4 inch Dia.) NX 25 kv EJO 38 kv 7278A27G29 7278A27G30 7278A27G31 7278A27G32 7278A27G33 7278A27G34 7278A27G35 7278A27G36 7278A27G37 7278A27G38 7278A27G39 7278A27G40 7278A27G41 7278A27G42 925 1050 1125 925 1050 775 1175 1175 850 1190 n Space Heaters Space Heaters (Voltage shown is half Rated Voltage) 125 V 250 V 220C974G03 220C974G04 as required as required 275 275 Other Replacement Parts Other replacement parts are available but must be considered on a job-by-job basis. Include switch nameplate information located behind the switch operating handle access door with any correspondence. Be sure this includes the CN or SM number. Further Information Literature Number DB IL 31-930-C Description Descriptive Bulletin for WLI Load Interrupter Metal Enclosed Switchgear Instruction Leaflet for WLI and WVB Metal Enclosed Switchgear Pricing Information Literature Number Description VISTA/VISTALINE Discount Symbol Y2

Page 6 Cutler-Hammer Westinghouse & Cutler-Hammer Products 11 Corporate Circle Sumter, South Carolina, U.S.A. 29154 Printed in U.S.A.