Cased/Uncased Coils For Gas And Oil Furnaces

Similar documents
Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Ruud High Efficiency Air Handler

INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

RCBA- MULTIFLEX INDOOR COILS

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

Rheem High Efficiency Air Handler

FORM NO. HSC-543 AIR HANDLERS

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

Rheem Classic Series Downflow Gas Furnace

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

Rheem Value Series Downflow Gas Furnace

Rheem High Efficiency Air Handler

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

Table of Contents GF801U Series

AIR CONDITIONERS WA16 SERIES

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

UPFLOW/ HORIZONTAL GAS FURNACE

INSTALLATION INSTRUCTIONS

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

Dual-Refrigerant Coils

AIR CONDITIONERS WA14**A SERIES

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Rheem Value Series Two-Stage Air Conditioners

CAPF, CAUF, CHPF, & CSCF DUAL-REFRIGERANT SERIES

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S


ELECTRIC HEAT AIR HANDLERS

FMU4X, FMC4X FMU4Z, FMC4Z

14.5 SEER VALUE SERIES CONDENSING UNITS

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Modular Variable Speed Air Handlers

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

B6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

Ruud Achiever Series Heat Pumps

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

B6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

13 SEER CONDENSING UNITS

Indoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

PACKAGE AIR CONDITIONERS

TECHNICAL SPECIFICATIONS

Indoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab

AWUF Series. Wall-Mount Air Handler 1½- to 3-Tons

Indoor Coils. CAUF, CAPF, CAPT, CHPF, and CSCF. Cased, Painted Upflow/Downflow, Uncased Upflow/Downflow, Horizontal A, and Horizontal Slab

Package Air Conditioners

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

HE Series Evaporator Coils

HE Series Evaporator Coils

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

TECHNICAL SPECIFICATIONS

ELITE SERIES R-410A Ready - Multi-Position

Rheem Prestige Series Heat Pumps Equipped with The Comfort Control 2. System

PRODUCT CATALOG. RSD (Refrigeration Supplies Distributor) / Spokane 212 E. Pacific Spokane (509) ruud.com. Rely on Ruud.

FEM4P, FSM4P, FSU4P. Product Specifications

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

[-]CHL. Parts List Multiflex Cased or Uncased. (R-410A) Indoor Coils Series L Sizes CATALOG TAB - Indoor Coils

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

Ruud Achiever Series Heat Pumps

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

Transcription:

Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use with Ruud outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Ruud outdoor units, the coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kw] to 48,000 BTU/HR [14.06 kw]. Constructed of aluminum fins bonded to internally grooved copper tubing. Tin plated copper tubing in the finned area for superior corrosion resistance in harsh environments. Coils are tested at the factory with an extensive refrigerant leak check. Coils have sweat refrigerant connections. Ideally suited for new installations or add on air conditioning. Feature two sets of 3 /4" [14.1 mm] N.P.T. Condensate drain connections for ease of connection. Coils are AHRI certified for system application with variety of Ruud outdoor units. Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material. Compatible with Germicidal Light System (UV resistant) Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right. Unique drain pan design maximizes application flexibility and condensate removal. Universal Duct Flanges are included with all coil models. FORM NO. C22-220

Table of Contents TABLE OF CONTENTS Model Number Identification...3 Coil Specifications...3 Coil Dimensions and Weights...4 Accessories...5-6 Limited Warranty...7 2

Model I.D./Coil Specifications Model Number Identification R C F L HM 24 14 A C Gas/Oil Furnace Coil C = Cased U = Uncased Design Variation A = 1st Design B = 2nd Design C = 3rd Design T = Tin plated copper tubing in finned area Coil Size 14 = 14" [356 mm] 17 = 17.5" [431.8 mm] 21 = 21" [533.4 mm] 24 = 24.5" [609.6 mm] Nominal Capacity 24/25 = 18,000 to 24,000 BTU/HR [5.27 to 7.03 kw] 26 = 24,000 BTU/HR [7.03 kw] 36/38 = 30,000 to 36,000 BTU/HR [8.79 to 10.55 kw] 48 = 42,000 to 48,000 BTU/HR [12.31 to 14.06 kw] 60 = 60,000 BTU/HR [17.58 kw] Cased Coil Airflow: HM = A/C or Heat Pump, Multi-Position AU = A/C Only, Upflow/Downflow Uncased Coil Airflow: HU = A/C or Heat Pump, Upflow/Downflow Refrigerant V = R-410A F = Product Generation Classification C = Coil Ruud Available Models of RCFL Coils RCFL-HM2414CC RCFL-HU2514CU RCFL-HM2514CC RCFL-HU2417CU RCFL-HM2417CC RCFL-HU3617CU RCFL-HM3617CC RCFL-HU3621CU RCFL-HM3621CC RCFL-HU4821CU RCFL-HM4821CC RCFL-HU4824CU RCFL-HM4824CC RCFL-HU6024CU RCFL-HM6024CC RCFL-HU3821CU RCFL-HM3821CC RCFL-HU3824CU RCFL-HM3824CC RCFL-HU2617CU RCFL-HM2617CC RCFL-HU2621CU RCFL-HM2621CC RCFL-HU2414TU RCFL-AU2414CC RCFL-HU2514TU RCFL-AU2514CC RCFL-HU2617TU RCFL-AU2417CC RCFL-HU2621TU RCFL-AU3617CC RCFL-HU2417TU RCFL-AU3621CC RCFL-HU3617TU RCFL-AU4821CC RCFL-HU3621TU RCFL-AU4824CC RCFL-HU4821TU RCFL-AU6024CC RCFL-HU4824TU RCFL-AU3821CC RCFL-HU6024TU RCFL-AU3824CC RCFL-HU3821TU RCFL-HU2414CU RCFL-HU3824TU Table 1: Coil Specifications/Airflow Pressure Drop Coil Model RCFL 2417 2617/3617 2621/3621 3821/4821 3824/4824 Approx. Design Air Flow CFM [L/s] Range 600/1000 [283/472] 900/1400 [424/661] 900/1400 [424/661] 1200/1800 [566/850] 1200/1800 [566/850] Face Area Sq. Ft. [m 2 ] 4.56 [0.42] 5.70 [0.53] 5.70 [0.53] 8.55 [0.79] 8.55 [0.79] Fins-in. Rows Deep 16/2 600 [285] HIGH EFFICIENCY COOLING COILS 600/1000 4.56.17 2414 16/2 [283/472] [0.42] [.043] 2514 6024 600/1000 [283/472] 1600/1900 [755/897] 4.56 [0.42] 9.98 [0.93] NOTE: Represents Coil-Only Airflow Ratings 16/2.15 [.039].22 [.055] 700 [330].21 [.053].19 [.049].29 [.072] 16/2 16/2 800 [380].25 [.063].23 [.059].36 [.090].17 [.043].15 [.038] Static Pressure Drop Through Wet Cooling Coil [kpa] (Inches W.C.) CFM [L/s] 900 [425].31 [.080].30 [.076].44 [.110].21 [.053].18 [.047] 1000 [470].40 [.100].38 [.096].52 [.130].26 [.064].23 [.058] 1100 [519].46 [.117].45 [.113] 576 [.144].31 [.080].27 [.069] 16/2 16/2 1200 [565] 1300 [614] 1400 [660] 1500 [708] 1600 [755] 1700 [802] 1800 [850] 1900 [897].36 [.092].31 [.080].22 [.056].22 [.056].41 [.103].37 [.094].25 [.063].25 [.063].28 [.071].28 [.071] 14/3.32 [.081].32 [.081].36 [.092].32 [.081].27 [.070].41 [.103].41 [.103].30 [.076].34 [.084].37 [.094] [ ] Designates Metric Conversions 3

Coil Dimensions and Weights Table 2: Coil Dimensions and Weights Coil Model RCFL Liquid I.D. Connections Sweat (in.) [mm] Suction I.D. A Cased Coil Dimensions (in) [mm] 2414*/2514* 3/8 [9.53] 3/4 [19.05] 14 1 /2[356] 21 1 /2[533] 23 3 /16 [584] 46 [21] 2417 3/8 [9.53] 3/4 [19.05] 17 1 /2 [445] 14 1 /2 [368] 20 1 /2 [508] 46 [21] 3821/4821 3/8 [9.53] 7/8 [22.23] 21 1 /2[533] 25 7 /8 [657] 28 1 /2 [711] 76 [34] B Coil Weight (lbs.) [Kg.] Shipping Weight (lbs.) [Kg.] 2617/3617 3/8 [9.53] 3/4 [19.05] 17 1 /2 [445] 17 7 /8 [454] 20 1 /2 [508] 52 [24] 57 [26] 2621/3621 3/8 [9.53] 3/4 [19.05] 21 1 /2[533] 17 1 /2 [445] 20 1 /2 [508] 54 [24] 60 [27] 3824/4824 3/8 [9.53] 7/8 [22.23] 24 1 /2 [622] 25 3 /8 [645] 32 1 /2 [812] 89 [40] 99 [45] 6024 3/8 [9.53] 7/8 [22.23] 24 1 /2 [622] 30 1 /4 [768] 32 1 /2 [812] 108 [49] *The 14 inch, 2 ton RCFL coil (2414) is part of the N-Coil design series, even though the coil shape resembles an A coil design. C Weight 50 [23] 51 [23] 83 [38] 118 [55] FIGURE 1: DIMENSIONS PLENUM WIDTH 19 7 /8 [505 mm] A MINUS ONE INCH ➀ FRONT VIEW SIDE VIEW NOTE: FLANGES ARE PROVIDED FOR FIELD INSTALLATION 1/2 [12.7 mm] 1 7 /16 [36.5 mm] SUCTION LINE 7/16 [11.1 mm] LIQUID LINE 5 15 /16 [150.8 mm] 4 1 /8 [104.7 mm] 5 3 /8 [136.5 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL & HORIZONTAL) 1 13 /16 [46 mm] 2 1 /4 [57.1 mm] SECONDARY DRAIN 3/4 N.P.T. (VERTICAL) 1 1 /4 [31.7 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL) 21 11 /16 [550.8 mm] ➀ Casing top and bottom openings are the same dimensions. [ ] Designates Metric Conversions 4

Accessories Table 3: Coil Application Coils can be matched to heating products as listed in table below. Accessories PLENUM ADAPTER ACCESSORY RXBA-AE This plenum adapter accessory is for use with the 24 1 /2" wide cased indoor cooling and heat pump coils. This allows a 24 1 /2" wide cased coil to be installed on a 28" wide oil furnace. This is a field-installed accessory only. RXBA-AC (Upflow/Horizontal) These plenum adapter accessories are for use when a cooling coil is matched with a gas furnace of one smaller size. HORIZONTAL ADAPTER KIT RXHH (See Figure 2) This horizontal adapter kit is used to convert a upflow or downflow coil for a horizontal application. See Table 4 to order the proper horizontal adapter kit. *Note: The horizontal adapter kit cannot be used for RCFL-AU****BC applications. It can only be used on RCFL-AU****AC applications and for RCFL-HU****AC applications. Table 4: Horizontal Adapter Kit Model No. Coil Model Coil Model RCFL 2414 2417 2514 2617 3617 2417 2617 3617 2621 3621 3821 4821 3824 4824 6024 Horizontal Adapter Kit Model No. 2414/2514 RXHH-A01 2417 RXHH-A02 3617/3621 RXHH-A03 4821/4824 RXHH-A04 FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION Oil Gas 14 [356] 21 [533] 21 [533] 24 1 /2 [622] Furnace Width (In.) (mm) *Note: Due to the proximity of the drain pan to the high temperature oil furnace drain, horizontal left application is not permitted on all oil furnaces. R X B C D 14 I 17 1 /2 [444] 14 [356] 21 [533] 17 1 /2 [444] 24 1 /2 [622] 21 [533] INDOOR COIL CASING- RXBC (See Table 5) INSULATION I = Insulated Blank = Uninsulated CABINET WIDTH 14 = 14" [356 mm] 17 = 17.5" [444 mm] 21 = 21" [533 mm] 24 = 24.5" [622 mm] DESIGN SERIES COIL CASING BLOWER UNIT ACCESSORY RUUD Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings Model Number Width (in.) [mm] Height (in.) [mm] RXBC-D14AI 14 [356] 23 3 /16 [589] RXBC-D17AI 17 1 /2 [445] 20 [508] 18 [8] 23 [10] 16 1 /2 [419] RXBC-D21AI 21 [533] 20 [508] [549] 20 [9] 26 [12] 20 [508] RXBC-D21BI 21 [533] 28 [711] 27 [12] 36 [17] 20 [508] RXBC-D24AI 24 1 /2 [622] 32 1 /2 [826] Depth (in.) [mm] 21 5 /8 Weight (lbs.) [Kg.] 34 [16] Unit Weight Ship. Wt. (lbs.) [Kg.] Supply Air/Return Air Openings 19 [9] 23 [10] 13 [330] 44 [20] Width (in.) [mm] 23 1 /2 [597] Depth (in.) [mm] 19 31 /32 [508] AIR FLOW HORIZONTAL-DUAL DIRECTION Table 6: Uncased Coil Adapter Kit Uncased Coil Adapter Model Number RXBA A Width (in.) [mm] B14x20 13 1 /8 [333] B17x20 16 5 /8 [422] B21x20 20 1 /8 [511] Uncased Coil Model RCFP -HUxx14 -HUxx17 -HUxx21 B24x20 23 5 /8 [599] -HUxx24 [ ] Designates Metric Conversions HORIZONTAL ADAPTER KIT (RXHH-) 5

Accessories Accessories (cont.) UNCASED COIL ADAPTER KIT RXBA- (See Figure 3 & 4) This uncased coil adapter kit is used to adapt the coil to a furnace or ductwork. See Table 6 to order the proper adapter kit. Each kit contains a quantity of 20 adapters. FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED 1 1 /2 [41 mm] 7 11 /16 [196 mm] A 20 5 /16 [516 mm] Note: Sliding the coil into the coil rail before attaching coil rack front. [ ] Designates Metric Conversions 6

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Parts...Five (5) Years Conditional Parts (Registration Required)...Ten (10) Years 7

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Ruud Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.ruud.com Ruud Canada 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A 01/13 QG FORM NO. C22-220