VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Similar documents
VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

The valves should be stored on a pallet or skid in a clean, dry warehouse. If the valves must be stored outside, the following apply:

2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:

INSTALLATION, OPERATION AND MAINTENANCE FOR SERIES 500 K-FLO BUTTERFLY VALVES

DeZURIK 2 20" BOS BUTTERFLY VALVES

DeZURIK DR 125 ROTARY DIAPHRAGM ACTUATOR

PO Box 411 Berwick PA VALV

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

CENTER LINE. INSTALLATION and MAINTENANCE INSTRUCTIONS RESILIENT SEAT BUTTERFLY VALVES MANUAL AND AUTOMATED

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

DeZURIK G-SERIES MANUAL ACTUATOR USED ON BOS BUTTERFLY VALVES

Storage: The valves should be stored on a pallet or skid in a clean, dry location.

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

Double Offset High Performance Butterfly Valve

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

DeZURIK SPRING RETURN CYLINDER OPERATOR FOR G-SERIES ACTUATORS USED ON PEF 100% PORT ECCENTRIC VALVES

NYL Resilient Seated Butterfly Valves Operation and Maintenance Instructions

DeZURIK R1 POWERRAC ACTUATOR ON 1/2-3" PEC ECCENTRIC VALVES

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

Butterfly valves Figure 56 Installation & Maintenance Instructions

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

Installation Operation Maintenance

Installation & Operation Manual

DeZURIK MANUAL G-SERIES ACTUATORS USED ON PEC ECCENTRIC VALVES

Installation, Operation, and Maintenance Manual

740G Double Disc Check Valve

Rectangular Butterfly Valve

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

YOUR GLOBAL FLOW CONTROL PARTNER. BRAY/MCCANNALOK EN High Performance Butterfly Valve Operation and Maintenance Manual

IOM Manual. IOM Manual. Series 76/77.

24 and Larger Butterfly Valves

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

DeZURIK CYLINDER OPERATED T-SERIES ACTUATOR

Keystone Figure V11 Butterfly Valve Installation, Operation and Maintenance Manual

720A Wafer & 821A Globe Style

BUTTERFLY VALVE - WAFER FAF 3500

DeZURIK R1 AND R2 POWERRAC ACTUATORS

DeZURIK M-SERIES MANUAL ACTUATOR

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

INSTRUCTION MANUAL RECTANGULAR BUTTERFLY VALVE 3-SIDED SEAT

3" 20" Bonded Seat Butterfly Valves

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

DEMCO Resilient-Seated Butterfly Valve

KEYSTONE SERIES GR RESILIENT SEATED BUTTERFLY VALVES GRW/GRL INSTALLATION AND OPERATION MANUAL

Recommended BFV Installation, Maintenance & Repair Procedures Ultraflo 300 & 400 Series Valves

Crispin Valves Operating Guide. Crispin

DeZURIK MODELS P41, P41D AND P42 PMV POSITIONERS

DeZURIK KUL KNIFE GATE VALVES

Series 820 AWWA Butterfly Valves

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724)

720G Wafer and 821G Globe Style Silent Check Valves

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual

PNEUMATIC SLIDING VALVE

SERIES 2100 Resilient Seated Butterfly Valves

APCO CSV-1600 SURGE CHECK VALVE

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724)

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

AWWA C504. Double Eccentric AWWA C504

A. This Section includes general duty valves common to several HVAC piping systems.

DEMCO DEMCO RESILIENT SEATED BUTTERFLY VALVE. Installation, Operation and Maintenance Manual D I S T R I B U T E D V A L V E S DEM-RSBV-IOM

Bray/Mckannalok Butterfly Valve Series 40/41/42/43/44/45 Installation Manual Technical Bulletin No Date: May 2004/Page 1 of 6

PDC Elastomer Lined Series 27 Butterfly Valve 2" thru 36" for 125/150 lb. Flanging

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Bray/McCannalok High Performance Butterfly Valve Operation and Maintenance Manual

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

DEMCO Resilient Seated Butterfly Valve

SERIES 2200 Replaceable Seat Butterfly Valves

DeZURIK BHP HIGH PERFORMANCE BUTTERFLY VALVE

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

These installation and maintenance instructions must be read in full and completely understood before the installation!

Metal Seated Ball Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: MSBVOM Revision Date: 07/06/09

DeZURIK VPB V-PORT BALL VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

DJ Series Butterfly Valves

DeZURIK PNEUMATIC CYLINDER OPERATOR FOR G-SERIES ACTUATORS

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

PMV P36C AND P41C POSITIONERS ACTUATORS

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Transcription:

VSI SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES VSI, LLC. 2-0 SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL Publication: V2100- August 2016

TABLE OF CONTENTS INSTRUCTIONS SAFETY MESSAGES FUNCTIONAL DESCRIPTION 4 RATINGS 4 INSTALLATION 5 TABLE 1 BOLT LENGTH 7 FIGURE 1 BOLT TIGHTENING 7 OPERATION 8 MAINTENANCE 8 TROUBLESHOOTING 8 V2100-2 08-16 2016 VSI, LLC.

INSTRUCTIONS: These instructions are for the SERIES 2100 2-0 Butterfly Valves and who will be responsible for the installation, operation and maintenance of the valves. SAFETY MESSAGES: All Safety messages in this manual are flagged with an exclamation symbol and the word Danger, Caution or Warning. These messages indicate procedures that must be followed exactly to avoid equipment damage, personal injury or death. WARNING Personnel involved in the installation or maintenance of valves should be constantly alert to potential emissions of pipeline material and take appropriate safety precautions. Always wear suitable protection when dealing with hazardous pipeline material, also handle valves that have been removed from service with suitable protection from any potential pipeline material in the valve. INSPECTION: Your SERIES 2100 Butterfly Valve has been packaged to provide protection during shipping. However, it is still possible to be damaged during shipping. Please inspect the unit for damage upon arrival and file a claim if damage is apparent. PARTS: Order parts from your VSI, LLC. sales representative. Please include the serial number, located on the valve tag, when ordering parts. WARNING Read all applicable instructions and directions prior to any maintenance, installation or troubleshooting. 2016 VSI, LLC. V2100-08-16

SECTION 1 - FUNCTIONAL DESCRIPTION The SERIES 2100 Butterfly Valve is a resilient-seated valve for general industrial and commercial applications. Both lugged and wafered end connections are available, and a variety of options in disc, shaft and seat materials. Pressure ratings are shown on the valve tag. The valve disc rotates 1/4 turn and provides bubble tight shutoff in water pipelines. The valves can be used to regulate flow rates by positioning the disc between 10 and 90 degrees open. SECTION 2 - RATINGS WARNING Valves shall never be exposed to temperatures or pressures beyond their rated capacity. Exposure to excess temperature or pressure will lead to increased likelihood of failure. Sec 2.1 Body Pressure Ratings Hydrostatic body maximum pressure ratings for the Series 2100 Butterfly Valve are shown below. Seat pressure may be a lower rating than the hydrostatic pressure rating and is noted on valve tag. Temperature ( F) Pressure (psi) -20 to 100 250 200 25 00 215 400 200 500 170 600 140 650 125 Sec 2.1 Seat Temperature Ratings Valve seats in the Series 2100 Butterfly Valve are rated continuously to the following temperatures: Material Temperature Rating ( F) EPDM -0 to 225 PTFE 40 to 250 Buna-N 10 to 180 Neoprene 20 to 200 Hypalon 0 to 275 Viton 10 to 275 High Temp. Viton 10 to 400 V2100-4 08-16 2016 VSI, LLC.

SECTION - INSTALLATION WARNING Valves are a significant component of any piping system. Failure due to faulty installation, improper operation or maintenance in such systems could result in damage, down time, and costly repairs. Many problems can be traced to improper installation, operation or maintenance procedures. Sec.1 Unloading Inspect valves upon receipt for any damage that may have occurred during shipping, as well as conformance with quantity, configuration and description from the shipping order. When removing valves from the shipping containers, be careful not to lift the valves using slings or chain around the operating shaft, actuator, or thru the waterway. Instead, lift the valves with eye bolts or rods thru the flange holes. Sec.2 Storage The valves should be stored on a pallet or skid in a clean, dry warehouse. If the valves must be stored outside, the following should apply: 1. Valves must be kept off the ground high enough to avoid standing water. 2. Cover the valves with a water repellent cover (not included with the valve), to prevent dirt and water from compromising the valve body or seat. Sec. Guidelines 1. SERIES 2100 Butterfly Valves are designed for installation between ANSI Class 125/150 flat or raised face flanges. Gaskets are not required. 2. SERIES 2100 Butterfly Valves have been designed so that the disc, in the open position, will clear the inside diameter of schedule 40 and 80 steel pipe. When installing the valve adjacent to lined pipe, as-cast fittings, or schedule 80 plastic pipe. In some instances the disc in the open position will interfere with the adjacent component and could cause damage to the disc.. SERIES 2100 Butterfly Valves are a unidirectional seat design, and need to be installed with the flow indicator on the body of the valve pointing with the correct direction of the flow. 4. For the best results in slurry service, position the valve assembly so that the valve stem is in the horizontal position, and the lower disc edge opens downstream. This will create a self-flushing effect, thereby extending the service life of the valve. 5. SERIES 2100 Butterfly Valves should be installed a minimum of six (6) pipe diameters upstream and four (4) pipe diameters downstream from other line components (valves, elbows, etc.). This is not always practical, but it is important to design in as much distance as possible. Sec.4 Pre-installation 1. Remove any protective flange covers from the valve and the pipe flanges. 2. Remove all material such as weld splatter, oil, grease, and dirt from the valve, flanges, and pipeline.. Check the valve identification tag to make sure it is the appropriate valve for the location and service that it is being installed for. 4. See Table 1 to make sure you have the appropriate size, threading and length of bolts for the valve. 2016 VSI, LLC. 5 V2100-08-16

Sec.5 Installation 1. SERIES 2100 Butterfly Valves should be installed in the Almost Closed position. You want to open the valve so that the seat is not entirely compressed, but still have the disc edges within the edges of the valve body. 2. Spread the flanges to exceed the valves face to face dimension.. Carefully place the valve into place between the flanges. Take care that the flange seating surface and the valve seats are not scratched. Do not apply any lubricants to the seat faces as this may damage them. 4. Line up, center and secure the valve between the flanges using the desired bolts or studs. Do not tighten bolts at this time. 5. Carefully open the valve to assure free and unobstructed disc movement. 6. While gradually removing the flange spreaders, center the valve body to the flanges and tighten the bolts hand tight. Slowly close the valve to check for adequate disc clearance. 7. Return the valve to the Almost Closed position. 8. Using an alternating cross-over pattern shown in Figure 1, tighten the bolts to the minimum torque values listed in Table 1. When installing valves 12 or larger, you want to tighten both sides of the valve evenly while still using the same cross-over pattern. 9. If an actuator is being used, connect any pneumatic or electrical connections as required by the actuator documentation. 10. Cycle the actuator fully, to the open and then to the closed position, checking the actuator travel stop settings for proper disc alignment. The valve should be operated to assure that no binding is taking place. 11. Pressurize the piping to the valve and inspect for leakage. If leakage occurs, tighten the bolts using the cross-over pattern, increasing the torque, till the leakage stops. Do not exceed maximum torques listed in Table 1. 12. The valve is now ready for service. V2100-6 08-16 2016 VSI, LLC.

TABLE 1: RECOMMENDED BOLT LENGTHS Valve Size Valve Solutions Lug and Wafer Valves, 2-0, ASME 125/150 Bolt Pattern Thread Size UNC Number Required Lug Bolt Length (in) Wafer Stud Length (in) Min Torque (ft-lbs) Max Torque (ft-lbs) 2 (DN50) 5/8-11 4 1.25 4.75 15 70 2.5 (DN65) 5/8-11 4 1.5 5.25 15 70 (DN75) 5/8-11 4 1.5 5.25 15 70 4 (DN100) 5/8-11 8 1.75 5.75 15 70 5 (DN125) /4-10 8 1.75 6 0 120 6 (DN150) /4-10 8 2 6.25 0 120 8 (DN200) /4-10 8 2.25 6.75 0 120 10 (DN250) 7/8-9 12 2.25 7.25 50 200 12 (DN00) 7/8-9 12 2.5 7.75 50 200 14 (DN50) 1-8 12 2.75 8.25 70 240 16 (DN400) 1-8 16 2.75 8.75 70 240 18 (DN450) 1 1/8-7 16.5 10 100 80 20 (DN500) 1 1/8-7 20 4 11.25 100 80 24 (DN600) 1 1/4-7 20 4.75 12.75 150 520 0 (DN750) 1 1/4-7 24 4.5 1.75 +4 4.25 (Bolt) 4.25 150 520 Bolting and torque recommendations are made without warranty, and apply only to steel weld-neck or slip-on flanges. The use of lock washers and/or lubrication with the bolting will affect stated torque values. FIGURE 1: RECOMMENDED BOLT TIGHTENING PATTERN 15 1 9 1 7 5 1 8 1 5 8 12 1 5 9 12 19 17 4 2 4 6 2 7 4 10 6 2 11 7 4 18 20 11 6 8 14 10 2 16 2016 VSI, LLC. 7 V2100-08-16

SECTION 4 - OPERATION Clockwise rotation of the valve shaft to close the disc into the seat. The valve is fully closed when the flat side of the disc is parallel with the flange sealing surface of the body. The valve is fully open when the disc is 90 counterclockwise from the closed position. A set of machined flats on the top of the valve shaft can be used to determine the approximate position of the disc when the disc is not visible. A valve actuator is connected to the valve shaft, and positions the disc at the closed, open, or intermediate position. Any adjustable stops for the open and closed positions of the valve are pre-set to match the valve s open and closed positions. Please see the actuator instructions for any information on adjusting the end stops on the actuator. SECTION 5 - MAINTENANCE Routine maintenance or lubrication is not required. SECTION 6 - TROUBLESHOOTING SYMPTOM PROBLEM SOLUTION The valve opens only a few degrees and stops. (The valve will not open fully.) Leakage past the flange face. Leakage in the closed position. (Leakage in the pipeline). Improper installation. The valve is improperly aligned. The flange bolts are not evenly torqued. Improper flanges. The disc is not closing fully. The actuator is not adjusted properly Damaged seat. Line pressure exceeds valve s working pressure. Damaged disc. Loosen the flange bolts, realign the valve with the flanges, and retighten the bolts to the recommend torques. Loosen the flange bolts and retighten them in the recommended order and toques. Please refer to Installation Guidelines on page 4 for proper flange requirements. See actuator documentation for proper adjustment of travel stops on the actuator. Replace valve. Reduce the line pressure to the valve s working pressure. Replace valve. Water hammer The valve is closing too quickly. Adjust actuator. Excessively high torque. Obstruction in the pipeline. Remove the valve from the pipeline and remove obstruction. Valve stem or disc bent. Replace valve. Check the pipeline for water hammer or freezing of line material. Scale build-up on stem or seat. Open and close the valve several times. Operate the valve at least once a month. Check the valve seat for deterioration. V2100-8 08-16 2016 VSI, LLC.