OmniAire Portable Air Cleaner OA1200PAC

Similar documents
Omniaire 1000V Instruction Manual-8/05

OmniAire 2200 Operations and Maintenance Manual

Specialists in HEPA Filtration and Negative Air Machines

OmniAire 600N Operations and Maintenance Manual

OmniAire 2200C Operations and Maintenance Manual

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

1600PAC. HEPA Air Filtration Machine. Operation and Maintenance Manual

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

MODEL FA1 Mini Air Filtration System. Operations Manual

FA1 Series Air Filtration System. Operations Manual

MODEL MC1500 Installation and Operation Manual Important:

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

Further information: Berriman Associates Model 850P.2 Owners Manual

MODEL FA5 Air Filtration System. Operations Manual

PHOENIX GUARDIAN H. E. P. A. SYSTEM

quatroair.com AIR TECHNOLOGIES INC.

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

PHOENIX MINI-GUARDIAN

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

MiniForce II. HEPA Air Filtration Machine. Operation and Maintenance Manual

2008 PCP COMPOUND APPLICATIONS GUIDE

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

MODEL MA4210 Installation and Operation Manual Important:

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

AIR FILTRATION DEVICE

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

6-54 HEPA Filter Assembly

2000C. HEPA Air Filtration Machine. Operation and Maintenance Manual

AS , EN12469 (Microbiological Testing Method)

SPH General Manual 400 Series

CRYSTAL-AIRE. concealed commercial air cleaners

MODELS: CAP600-UVP AND CAP600-UV INSTRUCTION MANUAL

TOTALINE ELECTRONIC AIR CLEANERS

Bio Cart HEPA 10. Operators Manual. Page 1 of 15. Bio Cart HEPA 10, 120 Volt P/N FG0185 Rev A. Specifications subject to change without notification

MODEL GS1-100 Air Filtration System. Operations Manual

1200 Portable Air Scrubber Model PRED1200UV INSTRUCTION MANUAL

PCR 6. Operators Manual. Vertical Laminar Airflow Cabinet with U.V. Sterilisation. Issue 05 September 2013

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

2200C. Operation and Maintenance Manual. HEPA Air Filtration Machine BY OMNITEC DESIGN, INC. BY OMNITEC DESIGN, INC. BY OMNITEC DESIGN, INC.

HEPA AIR FILTRATION SYSTEM

MODEL 950C-NP-UV Installation and Owners Manual

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

Air Boss M-Series Media & Adsorption Air Cleaner

Installation, Operations and Maintenance Guide

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Owner s Manual Phoenix GuardianR

HEPA-AIRE PORTABLE AIR SCRUBBER-PAS1800 INSTRUCTION MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

DESKTOP CONTAINMENT SYSTEM

AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation

Excelair. Every filter is created to perfection!

INSTRUCTION MANUAL. Abatement Technologies, Inc./Remediation Products Division. Abatement Technologies, Inc. Georgia, USA

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Ductless Nanoparticle Containment Enclosures

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

Protector Glove Boxes.

UV-AIRE AIR PURIFYING SYSTEM

MC2500. Installation and Operation Manual

PLANNING THE INSTALLATION

Maintenance Instructions

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

EXT DUCTLESS FUME HOOD

Owner s Manual Phoenix Mini-Guardian HEPA System

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

Ventilated Balance Enclosures

Biological Safety Cabinet

SECTION HVAC AIR CLEANING DEVICES

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

Owner s Manual Phoenix Guardian HEPA System

THE ENVIROMAC MOBILE AIR CLEANER ( ) OWNER S MANUAL

Owner s Manual. Airgle Radon Air Cleaner ( Model: AG600S )

Owner s Manual Phoenix Guardian HEPA System

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

INSTALLATION INSTRUCTIONS

BULLDOG PORTABLE AIR FILTRATION UNIT Models BD2KL and BD2KLA INSTRUCTION MANUAL

INSTRUCTION MANUAL D ABATEMENT TECHNOLOGIES, INC. U.S. PATENT D CANADIAN PATENT Abatement Technologies, Inc.

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

H2KM and H2KMA. Instruction Manual. Abatement Technologies, Inc. Abatement Technologies, Ltd. Georgia, USA. Ontario, Canada

Custom Shipyard and Military Facility Products

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Unimodule M2 Unidirectional Flow Clean Bench/Workstation OPERATION MANUAL

Portable HEPA System


OWNER S MANUAL. Installation and Service Manual

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

LAMINAR AIRFLOW EQUIPMENT

SPH-400 i Series General Manual

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

JUMBO. Fume Extraction Technology. Compact and Versatile. Filtertrolley 2.0. Extraction. Filtration. Persistence.

General. Technical Bulletin: ACCESSORY INFORMATION

Powered Air Purifying Respirator (PAPR) For Departments that Store, Supply and Maintain PAPR Units

Transcription:

OmniAire Portable Air Cleaner OA1200PAC The OmniAire Portable Air Purification system purifies the air of airborne contaminants which could be biological, chemical or particulates. Connected to an isolation containment, it can create small negative or positive pressure inside the containment. The negative pressure will prevent contaminants from leaking to the outside, while positive pressure would prevent contaminants from outside to enter the containment. All the air pulled from the containment or blown into the containment is purified through 99.99%, 0.3 micron HEPA filter and by high intensity UVGI lights. Optional carbon filters can also be added to the machine to remove chemical odors. www.omnitecdesign.com 2125 196th Street SW, Suite 115, Lynnwood, WA 98036 phone 425-774-3257 fax 425-774-4983 Page OmniAire PAC Instruction Manual 2008

PRODUCT SPECIFICATIONS: Net weight (with filters) Dimensions (LxWxH) Operating Speeds Airflow Ratings Filtration Stages 3-4 115 1bs. 22 x20 x40 Variable Speed Controller 99.99% 0.3µ HEPA Filter, Metal Frame, Medical Grade Standard Cabinetry Aluminum Closed End Rivet Construction Yes Silicon Sealed Seams before Riveting Yes Push Handle, Polyurethane One Casters* 4 Swivel 3 Motor Horse Power 3/4 hp Circuit Requirements (Volts/Hz) 115 VAC/60 Hz Maximum Operating Amps 7 Amps Thermal Overload Protection Yes Pressure Gauge 0-3 W.C. Optional Accessories: Intake/Exhaust Manifold 10 diameter ring Hose clamp, 10 diameter Flex hose 10 diameter Stainless Steel Quick Clamp *Optional 10 Wheels combined with 3 Casters 200 to 1100 CFM PARTS: OA1200PAC HEPA Filtration System HEPA filter 99.99% @ 0.3 micron, Size 16 x 16 x 12 Primary filter 40% efficiency pleated filter, Size 16 x 16 x 2 OPTIONAL FILTERS: OdorGuard 200 - Carbon Pleated Filter, Size 16 x 16 x 2 OdorGuard 600 Carbon Fiber Filter pad, Size 16 x 16 x 2 OdorGuard 750 Plus Carbon/Alumina/Potassium permanganate filter pad, Size 16 x 16 x 2 CONFORMS TO UL STD 507 CERTIFIED TO CAN/CSA STD C22.2 NO. 113-M1984 Page 2 3067108 OmniAire PAC Instruction Manual

INSTRUCTIONS Unpacking: Carefully check the unit for damage. Remove the exhaust cover grill and check the HEPA filter. It should be seated, the filter should be flush with the mounting brackets and the brackets should be compressing the filter down. The optional Intake Manifold (see Figure 1) provides flex hose connection and holds the primary pleated filter in place. Intake Manifold can be used on intake or exhaust side in place of the screen. The manifold is secured by four thumb screws. Operation: While the OmniAire PAC machine can operate outside the containment, it is recommended to protect it from the rain and dirty environment. For the following operation instructions, we are assuming that the machine is located inside the enclosure. If the machine is located outside the containment, the flex hose connections would be reversed. To create positive pressure inside the containment, more air has to be pumped in than leaks out. Connect the flex hose from the outside to the Intake Manifold on the suction side of the machine. The outside air is pulled through primary/secondary filter under a negative pressure. This prevents leakage of untreated air into the containment. Then the air passes through blower and over the UVGI lights, where it is sterilized and pushed through the HEPA filter to remove any particulates. The pure air stream, diffused by HEPA is then exhausted into the containment. The plastic sides of the containment should be bowed out to indicate positive pressure. The speed of the machine can be adjusted to meet your required number of air exchanges and the positive pressure. To maintain negative pressure inside the containment in reference to ambient pressure, more air has to be exhausted out than leaks into the containment. Install the Intake Manifold on the outlet side of the machine and connect the flex hose to the outside. All the air exhausted to the outside is treated by UVGI lights and by HEPA filter. The plastic walls of the containment will be bowed in, indicating negative pressure. By increasing fan speed, the pressure inside the containment becomes less than the outside pressure. As the doors to containment open, the pressure will temporarily change and return to normal when the doors close. The higher the speed, the faster the room will return to desired pressure. As the HEPA filter loads with dust, the speed will have to be increased to reach the same airflow and to maintain the desired pressure inside the containment. The PAC HEPA Filtration system must always operate with the HEPA filter in place to prevent contamination of the area and electrical overload of the motor. Operating UV Germicidal Lights UVGI lights are installed in the compartment facing the HEPA filter. The air passing by the UVGI lights is sterilized and the bio-contaminants captured on the HEPA are killed or deactivated. The UVGI lights should be turned on before the fan starts to run and should stay on after the air blower is stopped to complete the sterilization of the HEPA filter. The proper operation of the UVGI lights is monitored by UVGI and BALLAST indicating LEDs which turn on when the UVGI lights are on. Operating the PAC System: The PAC system should be connected to containment outlet with flex duct to create a negative or positive pressure in the room. The machine can also provide air purification as a self standing unit if desired. Page 3 OmniAire PAC Instruction Manual 2008

INSTRUCTIONS (Continued) Before starting the blower, turn on the UVGI lights. Check that the Ballasts and Lamps status lights came on. We recommend leaving the UVGI light on for another 10 minutes, after the air flow is turned of to sterilize the inside of the compartment and the intake side of the HEPA filter. The start and speed of the machine is controlled by the toggle switch HIGH / SPEED CONTROL and the variable SPEED CONTROLLER knob. To start the machine in the highest speed, place the toggle switch in HIGH position. To start the machine at reduced speed, place the toggle switch in SPEED CONTROL position and turn the knob clockwise from OFF to start the blower. The machine starts at HIGH SPEED and the speed is reduced by turning the knob clockwise to desired air flow. The machine can be switched between the desired controlled speed setting and the highest speed at any time by toggle switch being moved between SPEED CONTROL and HIGH. The toggle switch overrides the SPEED CONTROL- LER knob setting and runs the blower at its highest speed. This is also used as a quick check of HEPA filter loading and required filter change (see Maintenance). Maintenance: Mechanical and Electrical - The motor and blower do not require any maintenance when the machine is operated with the primary filter in place. CAUTION: In rare instances the blower wheel may become unbalanced. If severe vibration is present, stop operation and investigate the cause. The UVGI lights should last over 15,000 hours of operation. There are two high intensity lights UVGI lights and two ballasts. The LED indicating lamps turning OFF will indicate a light tube or ballast failure. The UVGI tubes and ballasts can be accessed by removing the HEPA filter. Do not look directly into the UVGI lamps, this could damage your eyesight. Filter Replacement - When replacing the HEPA filter, proper care should be taken to wear a respirator in combination with the necessary PPE if contaminated with hazardous material. The filter should be disposed of in an appropriate manner based on the contaminants it was exposed to. The HEPA filter element (see Figure 2) is held in place by metal tabs and can be accessed from the top of the unit. To remove the element, remove the metal grate, unscrew the nuts on the tabs (see Figure 3) and remove the tabs. Lay the machine down on the handle and slide the element out. Slide the new filter element into place with the gasket side of the HEPA filter facing the blower unit. Make sure that the HEPA filter is seated well against the internal flange. Place the machine back in the upright position, replace the filter tabs and nuts and tighten to where the filter is flush with the mounting brackets. Do not over tighten the bolts as this may crack the gasket. When replacing the HEPA filter, the primary filter should also be replaced. The primary filter should be checked or replaced monthly. To access the filter, remove the manifold or gate and install a new pleated filter. Observe the air flow arrow on the filter. The HEPA filter efficiency of 99.99% will not degrade when the filter is loaded with dust, but the air flow will be reduced. The HEPA filter should be replaced when: 1. The air flow from the machine is not sufficient to maintain the desired pressure in enclosure. 2. The machine must run in high speed all the time to maintain the desired pressure, which causes excessive noise. 3. HEPA filter is more than 80% loaded. NOTE: The loading of the filter can be checked by switching the machine to HIGH speed after replacing the primary filter and reading the pressure gauge WC. With all filters clean, the gauge should indicate 1.2 to 1.3 WC. A reading of 2.6 WC indicates the filter is 80% plugged and should be replaced. Page 4 OmniAire PAC Instruction Manual 2008

Figure 1. View of the OmniAire PAC Manifold Installation: Intake Manifold rests in a bottom channel and is secured by four thumb screws. Intake Manifold has replaced the intake screen Figure 2. HEPA Filter Installed in the Unit HEPA filter element mounting tab Figure 3. Close up of tabs for HEPA element HEPA Filter Element Intake/Exhaust Manifold and Flex Duct (Optional) Primary Filter Element Page 5 OmniAire PAC Instruction Manual 2008

REFERENCE MATERIALS: Page 6 OmniAire PAC Instruction Manual

OmnniAire Portable Air Cleaners for First Response Shelters OmniAire PAC with HEPA and UVGI lights have been designed specifically to meet CDC requirements for clean, filtered air in a medical environment. Each air filtration system is equipped with a medical grade, metal frame, HEPA filter element that has been factory tested and certified as 99.99% efficient at 0.3 microns. The OMNIAIRE PAC units can be paired with Environmental Containment Units to provide a comprehensive solution by providing a durable, standardized, prefabricated containment for quick emergency response.. Available Models OmniAire 800 PAC: Compact size, variable airflow; 150-600 CFM, Weight: 75 lbs Size: 36 H X 15 W X 15 D OmniAire 1200 PAC: Versatile, variable air flow for larger areas; 200-1100 CFM, Weight: 115 lbs, Size: 40 H X 23 W X 20 D with wheels OmniAire 2000PAC: Most powerful model with the largest range of variable airflow; 200-1800 CFM, Weight: 125 lbs, Size: 40 H X 24 W X 29 D with wheels Optional Wheel/Caster combination Page 7 OmniAire PAC Instruction Manual 2008