Thermocouples W A T L O W

Similar documents
Thermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA

Thermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances

RAPID SHIP SENSORS, STOCK WIRE

Thermocouples W A T L O W

MGO Thermocouples. Controls. Connection Head. Connection Head. Thermowells. Junction Fittings. Connectors Connection Heads.

Adjustable Bayonet Thermocouple

Plastic B26650 ORDER CODES. Configuration Code PL01 General-Purpose Tube and Wire Thermocouples TOLERANCES TOLERANCES. Example Order Number:

HEATERS AND THERMOCOUPLES

Plastic. General Purpose Tube and Wire Thermocouples ORDER CODES. Example Order Number:

C 6" TYPICAL 5/8" ORDER CODES JP3 3 U. Options

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

MgO ORDER CODES. 1-1 Thermocouple Types CODE

Plastics Machinery Thermocouples - Type 4, 7, 10, 11 & 19

ORDER CODES CODE. Special limits of error High-Purity MgO Insulation (99.4% Pure) Use this table only if options are desired.

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product

Cerampak is weldable, flexible - can be bent on a radius 2 times its diameter - and moisture free when fabricated.

For the plastics machinery industry Manifold thermocouple Model TC47-MT

Hot Runner Thermocouples Model TC46

Valves, MRO Items, Heaters, Thermocouples, and so much more

Cartridge Heaters W A T L O W FIREROD. Cartridge Heaters

Hot runner thermocouple Model TC46

NOZZLE HEATER BANDS. Part No. Standard Metric Watts Volts Quantity Prices

hotrod Cartridge Heaters

ORDER CODES CODE SINGLE DUPLEX TRIPLEX E EE - J JJ JJJ K KK KKK T TT - N NN -

Short Form Catalogue AJ Thermosensors

hotrod Cartridge Heaters Application Fields

Band Heaters Maxiband Heaters Maxiband The Most Sought After Band Heater

Cast-In Heaters Large Thermo-Platens

N I S T traceable calibration equipment conforms to MIL-STD-45662A.

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG

SEALED PLATINUM SURFACE TEMPERATURE SENSOR MODEL 29399

Cartridge Heaters CARTRIDGE

Ford Fabricated Steel Products

NTC Thermistor Assemblies

Sensors. Table of Contents. Remote Mounted Model 1340 (A-3) Field Adjustable (A-4) General Purpose (A-24)... 4

3 Terminals, Kits and Tools

Section 3 Index Furnace Tube Skin Thermocouples

3 Terminals, Kits and Tools

Article on Sheath materials, Thermowells, Fittings, and Terminations

Standard wire insulation is glass over glass with a stainless steel overwrap. Dual and single element. MgO versions available. rubber outer jacket.

AccuTru ExL Furnace Tubeskin Thermocouples

Hotset High-Watt Density Cartridge Heaters

Flexible Heaters. Silicone Rubber Heaters

Electronic Temperature Sensor

Introduction to Heat Trace Cable Systems

Maximum Temperature Rating 200 C ORDER CODES CODE DESCRIPTION. 4 Head Terminations CODE DESCRIPTION 8HN63 9HP63

Series 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF

Natural Gas Truckee Tahoe Airport Road Truckee CA

Roller Selection Flowchart

SECTION 7: MINIATURE SENSORS

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air

Surface thermocouple Model TC50

Lubrication Installation Components, Accessories & Fittings Table of Contents

Section N. 09/2017 Web Revision 10/23/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Fabricated Steel Products

Mineral Insulated Resistance Thermometers (RTD)

TEMPERATURE SENSORS TEMPERATURE SENSORS

Accessories Guide ph/orp/conductivity Sensors

TE-6300 Series Temperature Sensors Catalog Page

EFFICIENCY: In order to maximize power, prolong battery life and minimize power requirements, low loss connections assists in managing these.

Cartridge Heaters. Application Field. Application examples

PLASTICS INDEX...L-1 PLASTIC CAPABILITIES...L-2

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

Palmer Circular Chart Recorders

C07 - Probes. Sonde EN Pg.01/ E.M.P. Srl -ITALY -

INSTALLATION INSTRUCTIONS

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

( )

(770)

Sanitary RTDs and Temperature Transmitters

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

P & P Technology Ltd

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Band Heaters W A T L O W. THINBAND Mica Barrel and Nozzle

General Cable Support Information

SPRING LOADED DEVICES

Temperature Sensors. Description. Specification

FAX: SPECIAL APPLICATION HOSES, METAL & TEFLON HOSES

Technologies International Division of APS-Materials, Inc

Section J Air Control Nozzles

Sizes 1/4" through 4" Medium Throttling Band

Heavy Duty Copper Battery Terminals

Integrated Process Solutions. Series 88. CF Component Ultra high vacuum fittings Sizes 1 1/3'' to 4 5/8''

SECTION Pressure & Temperature Control

A driving force in the market place

Keystone Figure 990 and 920 Resilient Seated Butterfly Valves

Cable thermocouple Model TC40

Steel Conduits Conduit Fittings Flexible Conduits

Hot Sprue Bushings Products/Technical Guide

ADJUSTABLE FOOT INSERTS FOR ROUND TUBING

Cooling Heating Ventilation Electromechanical Solutions

Whether it s a harsh outdoor environment or an indoor desktop, PowerFilm has an optimal solution for your application.

Seismic Sensor Accessories SA, SV & ST 6000 Series

Imperial: 230Vac. Part No SC: Standard, Low to Medium Watt Density, HS: Superwatt, High Watt Density

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

argco.com

Multi-Range, Rigid Stem Melt Pressure Transducer

FLANGE. Flanges used for

Transcription:

W A T L O W Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions of thermocouples for industrial and commercial equipment. People involved in critical process control of food, plastics and metal rely on our sensors. We are ready to meet your sensing needs with our extensive offering of thermocouples. However, if the variations listed in this catalog are unable to satisfy your requirements, Watlow can custom manufacture sensors to your exacting specifications. Contact your Watlow representative for details. Performance Capabilities Fiberglass insulated thermocouples are capable of temperatures up to 480 C (900 F) for continuous operation. Features and Benefits Custom-tailored standard products including: 32 standard sheath lengths lengths from six to 360 inches Stainless steel braid or hose protection, K, T and E calibrations Grounded, ungrounded and exposed junctions Flat and drill point Epoxy sealed cold ends Adjustable depths Flexible extensions Washers, nozzles and clamp bands Custom diameters PFA coated and stainless steel sheaths Straight, 45 bend or 90 bend Locking bayonet caps in standard, 2 mm and 5 mm Custom manufactured thermocouples Units designed and built to your specifications Applications Plastic injection molding machinery Food processing equipment Deicing Plating baths Industrial processing Medical equipment Pipe tracing control Industrial heat treating Packaging equipment Liquid temperature measurement Refrigerator temperature control Oven temperature control 43

Construction and Tolerances Construction feature flexible SERV-RITE wire insulated with woven fiberglass or high temperature engineered resins. For added protection against abrasion, products can be provided with stainless steel wire braid and flexible armor. ASTM E 230 color-coding identifies standard catalog thermocouple types (see reference chart on inside back cover). The addition of a metal sheath over the thermocouple provides rigidity for accurate placement and added protection of the sensing junction. Mounting options include springs, ring terminals, specialized bolts, pipe style clamps and shims. How to Order Determine style of thermocouple required Complete the eleven digit part number as determined by the following parameters: Construction Diameter Calibration protection unction Sheath length length Terminations/options Note: All eleven spaces must be filled in. Availability Rapid Ship sensors are available for same or next day shipment. Preferred sensor options are available for shipment in approximately three days. For custom built products consult factory for approximate shipment time. 44

W A T L O W Adjustable Spring Style Rapid Ship sensors come with 24 gauge stranded fiberglass lead with stainless steel overbraid and grounded junction. Spring Termination Calibration in. (mm) in. (mm) Split s Standard Connector 24 (60) 0DSGB024A 0DSGB024D 48 (29) 0DSGB048A 0DSGB048D 6 (52) 72 (829) 0DSGB072A 0DSGB072D 96 (2438) 0DSGB096A 0DSGB096D 24 (60) DSGB024A DSGB024D 48 (29) DSGB048A DSGB048D 2 (305) 72 (829) DSGB072A DSGB072D 96 (2438) DSGB096A DSGB096D D B Spring (Spring O.D. = 0.250 in. (6.3 mm) Sheath 0.325 in. (7.9 mm) Adjustable spring style thermocouple fits a large range of hole depths. Bends to any angle, eliminating the requirement to stock numerous styles. 0 = Standard cap - 6 inch spring = Standard cap - 2 inch spring 4 = 2 mm cap - 6 inch spring 5 = 5 mm cap - 6 inch spring 6 = 2 mm cap - 2 inch spring 7 = 5 mm cap - 2 inch spring 3. Sheath Diameter (inch), 36 SS D = 3 6 5. Protection F = Fiberglass (24 gauge stranded) P = Fiberglass (20 gauge stranded) B = Fiberglass with stainless steel overbraid (20 gauge stranded) V = PFA (20 gauge stranded) W = PFA with stainless steel overbraid (20 gauge stranded) F = Grounded, flat tip U = Ungrounded, round tip G = Grounded, round tip P = Ungrounded, drill point D = Grounded, drill point H = Grounded, round tip, dual element R = Ungrounded, flat tip S = Ungrounded, round tip, dual element 7. Sheath (inch) B = 8-0. (whole inches) 45

Adjustable Armor Style Rapid Ship sensors come with 24 gauge stranded fiberglass lead with stainless steel armor and grounded junction. Termination Calibration in. (mm) Split s Standard Connector 48 (29) 2DHGB048A 2DHGB048D 60 (524) 2DHGB060A 2DHGB060D 72 (829) 2DHGB072A 2DHGB072D 96 (2438) 2DHGB096A 2DHGB096D 20 (3048) 2DHGB20A 2DHGB20D 2 D B 0.265 in. (6.7 mm) O.D. Sheath 0.325 in. (7.9 mm) Adjustable armor thermocouple fits a large range of hole depths. Bends to any angle, eliminating the requirement to stock numerous styles. Stainless steel hose offers additional lead protection in demanding applications. 2 = Adjustable armor thermocouple, standard cap 3. Sheath Diameter (inch), 36 SS D = 3 6 = Type K = Type K T = Type T E = Type E 5. Protection H = Fiberglass with stainless steel hose (24 gauge stranded) C = Fiberglass with stainless steel hose (20 gauge stranded) K = PFA with stainless steel hose (24 gauge stranded) Y = PFA with stainless steel hose (20 gauge stranded) F = Grounded, flat tip G = Grounded, round tip D = Grounded, drill point U = Ungrounded, round tip P = Ungrounded, drill point R = Ungrounded, flat tip H = Grounded, round tip, dual element S = Ungrounded, round tip, dual element 7. Sheath (inch) B = 8-0. (inches) 46

W A T L O W Rigid Sheath 8 and 3 6 inch Diameter Rigid sheath provides protection and accurate placement through bulkheads or platens. Use with a compression fitting for water tight immersion application. Rapid Ship sensors come with 3 6 inch diameter sheath, 24 gauge stranded fiberglass lead with stainless steel overbraid, grounded junction and split lead termination. Sheath Calibration in. (mm) in. (mm) Part Number 48 (29) 20DSGB048A (25) 96 (2438) 20DSGB096A 48 (29) 20DSGD048A 2 (5) 96 (2438) 20DSGD096A 48 (29) 20DSGH048A 4 (02) 96 (2438) 20DSGH096A Sheath.25 in. (28.6 mm) A A.375 in. (34.9 mm) Bent rigid tube offers protection and accurate lead placement around machinery. 0.375 in. R (9.5 mm) 0.375 in. R (9.5 mm) 0.25 in. (6.4 mm) Dia. R = 0.5 in. (2.7 mm) H =.625 in. (4.3 mm) 0.375 in. (9.5 mm) Dia. R = 0.75 in. (9 mm) H =.875 in. (47.6 mm) * Not available with 8 inch diameter sheath. Metric sizes available for made-to-order units, consult factory. Minimum order quantity may apply. 20 = Plain sheath, straight 2 = Plain sheath, 45 bend 22= Plain sheath, 90 bend 3. Sheath Diameter (inch), 36 SS C = 8 S = 8 epoxy sealed 49 C (300 F) D = 3 6 T = 3 6 epoxy sealed 49 C (300 F) 5. Protection F = Fiberglass (24 gauge stranded) H = Fiberglass with stainless steel hose (24 gauge stranded) *P = Fiberglass (20 gauge stranded) *B = Fiberglass with stainless steel overbraid (20 gauge stranded) *C = Fiberglass with stainless steel hose (20 gauge stranded) O = Plug or jack termination on sheath fiberglass (24 gauge stranded) K = PFA with stainless steel hose (24 gauge stranded) *V = PFA (20 gauge stranded) *W = PFA with stainless steel overbraid (20 gauge stranded) *Y = PFA with stainless steel hose (20 gauge stranded) F = Grounded, flat tip P = Ungrounded, drill point G = Grounded, round tip E = Exposed D = Grounded, drill point *H = Grounded, round tip, dual element R = Ungrounded, flat tip *S = Ungrounded, round tip, dual element U = Ungrounded, round tip 7. Sheath (inches) A= 2 D= 2 G= 3 2 K = 5 N = 6 2 R = 8 U = 9 2 Z = 2 B= E=2 2 H= 4 L = 5 2 P = 7 S = 8 2 W= 0 C= 2 F=3 = 4 2 M = 6 Q = 7 2 T = 9 Y = 8-0. (inches) 47

Rigid Sheath with Threaded Fitting 8 and 3 6 inch Diameter Silver Braze 2 in. (5 mm) Rigid sheath with threaded fitting provides accurate placement in process applications. * Not available with 8 inch diameter sheath. B 23 = Straight sheath with 8" NPT SS fitting 24 = Straight sheath with 2" NPT SS fitting 3. Sheath Diameter (inch), 36 SS C = 8 S= 8 epoxy sealed 49 C (300 F) D = 3 6 T = 3 6 epoxy sealed 49 C (300 F) 5. Protection F = Fiberglass (24 gauge stranded) H = Fiberglass with stainless steel hose (24 gauge stranded) *P = Fiberglass (20 gauge stranded) *B = Fiberglass with stainless steel overbraid (20 gauge stranded) *C = Fiberglass with stainless steel hose (20 gauge stranded) K = PFA with stainless steel hose (24 gauge stranded) *V = PFA (20 gauge stranded) *W = PFA with stainless steel overbraid (20 gauge stranded) *Y = PFA with stainless steel hose (20 gauge stranded) F = Grounded, flat tip G = Grounded, round tip D = Grounded, drill point R = Ungrounded, flat tip U = Ungrounded, round tip P = Ungrounded, drill point E = Exposed *H = Grounded, round tip, dual element *S = Ungrounded, round tip, dual element 7. "B" Dimension (inches) A= 2 D= 2 G= 3 2 K = 5 N = 6 2 R = 8 U = 9 2 Z = 2 B= E=2 2 H= 4 L = 5 2 P = 7 S = 8 2 W= 0 C = 2 F=3 = 4 2 M= 6 Q = 7 2 T = 9 Y = 8-0. (inches) Metric sizes available for made-to-order units, consult factory. Minimum order quantity may apply. 48

W A T L O W PFA Encapsulated Style 6 5 Sheath The rigid sheath is covered with a 0.00 inch (25 mm) wall of PFA for corrosion resistance in acid environments. An epoxy seal improves moisture resistance of sensor and provides a barrier for migrating fumes in corrosive applications. 65 = PFA coated sheath 3. Diameter (inch) under covering C= 8 epoxy seal 49 C (300 F) D= 3 6 epoxy seal 49 C (300 F) E= 4 epoxy seal 49 C (300 F) 5. protection *R = PFA (20 gauge stranded) U = Ungrounded, round tip G = Grounded, round tip 7. Sheath (inches) B= = 4 2 R = 8 C= 2 K = 5 S = 8 2 D= 2 L = 5 2 T = 9 E=2 2 M = 6 U = 9 2 F= 3 N = 6 2 W = 0 G= 3 2 P = 7 Y = H= 4 Q = 7 2 Z = 2 8-0. (inches) B=2 2 inch split leads with #6 spade lugs C= 2 2 inch split leads with #6 spade lugs and BX connector H= 4 inch push-on connector *Not available in 8 inch diameter. 49

Flange Style Rapid Ship sensors come with 3 6 inch diameter sheath, 24 gauge stranded fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. B Dimension Calibration in. (mm) in. (mm) Part Number 48 (29) 25DSGD048A 2 (5) 96 (2438) 25DSGD096A 48 (29) 25DSGH048A 4 (02) 96 (2438) 25DSGH096A The flanged thermocouple allows rapid assembly and low profile when going through bulkheads. * Not available with 8 inch diameter sheath. Metric sizes available for made-to-order units, consult factory. Minimum order quantity may apply. 50 in. B D C C = 3 /4 in D = in. H = 0.44 in. 2 5 25 = Thermocouple with flange 3. Sheath Diameter (inch), 36 SS C = 8 S = 8 epoxy sealed 49 C (300 F) D = 3 6 T = 3 6 epoxy sealed 49 C (300 F) 5. Protection F = Fiberglass (24 gauge stranded) H = Fiberglass with stainless steel hose (24 gauge stranded) *P = Fiberglass (20 gauge stranded) *B = Fiberglass with stainless steel overbraid (20 gauge stranded) *C = Fiberglass with stainless steel hose (20 gauge stranded) K = PFA with stainless steel hose (24 gauge stranded) *V = PFA (20 gauge stranded) *W= PFA with stainless steel overbraid (20 gauge stranded) *Y = PFA with stainless steel hose (20 gauge stranded) F = Grounded, flat tip P = Ungrounded, drill point G = Grounded, round tip E = Exposed D = Grounded, drill point *H = Grounded, round tip, dual element R = Ungrounded, flat tip *S = Ungrounded, round tip, dual element U = Ungrounded, round tip 7. B Dimension (inches) D=2 H=4 M= 6 R =8 W= 0 E=2 2 = 4 2 N=6 2 S=8 2 Y= F=3 K=5 P=7 T=9 Z=2 G=3 2 L = 5 2 Q=7 2 U=9 2 8-0. (inches) B= 2 2 inch split leads with #6 spade lugs C=2 2 inch split leads with #6 spade lugs and BX connector H= 4 inch push-on connector

W A T L O W Rigid Sheath Fixed Bayonet Style Rapid Ship sensors come with 3 6 inch diameter sheath, 24 gauge stranded fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. B Dimension Calibration in. (mm) in. (mm) Part Number 48 (29) 30DSGD048A 2 (5) 96 (2438) 30DSGD096A Bayonet fittings 48 (29) 30DSGF048A allow rapid 3 (76) 96 (2438) 30DSGF096A attachment. 48 (29) 30DSGH048A 4 (02) Spring pressure 96 (2438) 30DSGH096A on the junction tip assures fast response time. B 0.75 in. (9 mm) B in. (25 mm).625 in. (4.3 mm).375 in. (34.9 mm).625 in. (4.3 mm) 0.375 in. R (9.5 mm) 0.75 in. (9 mm) 0.375 in. R (9.5 mm) B.625 in. (4.3 mm).625 in. (4.3 mm) This style of bayonet fitting is quick connecting and allows leads to exit with a protective sheath. Reference page 29 to calculate B dimension. * Not available with 8 inch diameter sheath. a Metric sizes available for made-to-order units, consult factory. Minimum order quantity may apply. 30 = Bayonet cap with spring, straight 3 = Bayonet cap with spring, 45 bend 32 = Bayonet cap with spring, 90 bend 3. Sheath Diameter (inch), 36 SS C= 8 S = 8 epoxy sealed 49 C (300 F) D= 3 6 T = 3 6 epoxy sealed 49 C (300 F) 5. Protection F = Fiberglass (24 gauge stranded) H = Fiberglass with stainless steel hose (24 gauge stranded) *P = Fiberglass (20 gauge stranded) *B = Fiberglass with stainless steel overbraid (20 gauge stranded) *C = Fiberglass with stainless steel hose (20 gauge stranded) O = Plug or jack termination on sheath fiberglass (24 gauge stranded) K = PFA with stainless steel hose (24 gauge stranded) *V = PFA (20 gauge stranded) *W = PFA with stainless steel overbraid (20 gauge stranded) *Y = PFA with stainless steel hose (20 gauge stranded) F = Grounded, flat tip P = Ungrounded, drill point G = Grounded, round tip E = Exposed D = Grounded, drill point *H = Grounded, round tip, dual element R = Ungrounded, flat tip *S = Ungrounded, round tip, dual element U = Ungrounded, round tip 7. B Dimension a (inches) D= 2 G=3 2 K=5 N=6 2 R=8 U = 9 2 Z=2 E=2 2 H= 4 L=5 2 P=7 S=8 2 W=0 F=3 = 4 2 M= 6 Q=7 2 T=9 Y = 8-0. (inches) B=2 2 inch split leads with #6 spade lugs C=2 2 inch split leads with #6 spade lugs and BX connector H= 4 inch push-on connector R = Double slotted 2 mm bayonet cap, split end leads S = Double slotted 5 mm bayonet cap, split end leads 5

Large Diameter Rigid Sheath Style 4 and 3 8 inch Diameter A 52 Sheath A R H Rigid sheath provides protection and accurate placement through bulkheads or platens. Use with a compression fitting for water tight immersion application. Bent rigid tube offers protection and accurate lead placement around machinery. H R 0.25 in. (6.4 mm) Dia. R = 0.5 in. (2.7 mm) H =.625 in. (4.3 mm) 0.375 in. (9.5 mm) Dia. R = 0.75 in. (9 mm) H =.875 in. (47.6 mm) Metric sizes available for made-to-order units, consult factory. Minimum order quantity may apply. Rapid Ship sensors come with 4 inch diameter sheath, 20 gauge stranded fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. Sheath Calibration in. (mm) in. (mm) Part Number 48 (29) 40EBGD048A 4 (02) 96 (2438) 40EBGD096A 48 (29) 40EBGF048A 6 (52) 96 (2438) 40EBGF096A 40= Plain sheath, straight, large, diameter 4= Plain (45 ) large diameter 42= Plain (90 ) large diameter 3. Sheath Diameter (inch), 36 SS E= 4 U = 4 epoxy sealed 49 C (300 F) G= 3 8 V = 3 8 epoxy sealed 49 C (300 F) 5. Protection F = Fiberglass (24 gauge stranded) H = Fiberglass with stainless steel hose (24 gauge stranded) P = Fiberglass (20 gauge stranded) B = Fiberglass with stainless steel overbraid (20 gauge stranded) C = Fiberglass with stainless steel hose (20 gauge stranded) K = PFA with stainless steel hose (24 gauge stranded) V = PFA (20 gauge stranded) W = PFA with stainless steel overbraid (20 gauge stranded) Y = PFA with stainless steel hose (20 gauge stranded) F = Grounded, flat tip E = Exposed G = Grounded, round tip H = Grounded, round tip, dual element R = Ungrounded, flat tip S = Ungrounded, round tip, dual element U = Ungrounded, round tip 7. Sheath (inches) A= D=4 G = 7 K = 0 N = 3 R = 6 U = 9 Z = 24 B=2 E = 5 H = 8 L = P = 4 S = 7 W = 20 C=3 F = 6 = 9 M = 2 Q = 5 T = 8 Y = 22 8-0. (inches)

W A T L O W Flexible Extensions A Flexible extensions allow the disconnecting of thermocouples from a system without disturbing the remaining wiring. ** Not available with SS hose. Rapid Ship sensors come with standard female connector and a split lead termination. Calibration Protection in. (mm) Part Number K Fiberglass with SS 48 (29) 60XBXE048A overbraid 96 (2438) 60XBXE096A Fiberglass with SS 48 (29) 60XCXE048A hose 96 (2438) 60XCXE096A Fiberglass with SS 48 (29) 60XKBXE048A overbraid 96 (2438) 60XKBXE096A Fiberglass with SS 48 (29) 60XKCXE048A hose 96 (2438) 60XKCXE096A 6 0 X X 60 = Flexible extension 3. Diameter X = Not applicable 5. Protection F = Fiberglass (24 gauge stranded) P = Fiberglass (20 gauge stranded) B = Fiberglass with stainless steel overbraid (20 gauge stranded) C = Fiberglass with stainless steel hose (20 gauge stranded) K = PFA with stainless steel hose (24 gauge stranded) V = PFA (20 gauge stranded) W = PFA with stainless steel overbraid (20 gauge stranded) Y = PFA with stainless steel hose (20 gauge stranded) X = Not applicable 7. Termination A B = 2 2 inch split leads with spade lugs C = 2 2 inch split leads with spade lugs and BX Connector * * 8-0. (inches). Termination B 53

Insulated Wire Thermocouple Style 6 and Style 62 Rapid Ship sensors come with 24 gauge solid FEP insulated lead and a split lead termination. Calibration Protection in. (mm) Part Number K T Extruded FEP Extruded FEP 48 (29) 6XKTEX048A 96 (2438) 6XKTEX096A 48 (29) 6XTTEX048A 96 (2438) 6XTTEX096A X E X Style 6 Style 62 Teflon Encapsulated Thermocouple unction * Only available with wire (lead protection) options or T (5th digit). 6 = SERIES 6 * 62= SERIES 62 3. Diameter X = Not applicable = Type K = Type K T = Type T 5. Protection P = Fiberglass (20 gauge solid) B = Fiberglass with stainless steel overbraid (20 gauge solid) = Extruded FEP (20 gauge solid) F = Fiberglass (24 gauge solid) S = Fiberglass with stainless steel overbraid (24 gauge solid) T = Extruded FEP (24 gauge solid) E = Exposed 7. Exter X 8-0. (inches) 048 and 096 Available lengths: 006 to 600, over 600 consult factory B = 2 2 inch split leads with spade lugs Teflon is a registered trademark of E. I. du Pont de Nemours & Company 54 Constructed with SERV-RITE insulated thermocouple wire Styles 6 and 62 are economical and versatile thermocouples with the option of an exposed or protected measuring junction. Style 6 has an exposed junction and is suitable for most general purpose applications, such as measuring air, gas and surface temperatures. Style 62 has an encapsulated measuring junction that is ideal for corrosive fluids and gases such as sulfuric acid, hydrofluoric acid, strong mineral acids and oils. Styles 6 and 62 are available with fiberglass insulated lead wire (SERIES 304 construction), with continuous temperature ratings of 480 C (900 F). Or, order it with FEP insulated lead wire (SERIES 507), rated to 200 C (400 F) continuous temperature. For additional mechanical strength and abrasion resistance, a stainless steel overbraid is available.

W A T L O W Ring Terminal Style Rapid Ship sensors come with 24 gauge stranded fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. Stud Calibration Size in. (mm) Part Number No. 0 4 48 (29) 70XSGC048A 96 (2438) 70XSGC096A 48 (29) 70XSGD048A 96 (2438) 70XSGD096A 7 0 X Stud Size The nickel terminal can be placed beneath existing screws or bolts to permit surface temperature measurement. ** Only available with 24 gauge wire. 70 = Ring terminal thermocouple 3. Diameter X = Not applicable 5. Protection F = Fiberglass (24 gauge stranded) P = Fiberglass (20 gauge stranded) B = Fiberglass with stainless steel overbraid (20 gauge stranded) V = PFA (20 gauge stranded) W= PFA with stainless steel overbraid (20 gauge stranded) G = Grounded *U = Ungrounded 7. Stud Size Hole Diameter (inches) *A = No. 6 0.44 *B = No. 8 0.69 *C = No. 0 0.96 D= 4 0.266 E= 3 8 0.390 8-0. (inches) 55

Nozzle Style Rapid Ship sensors come with 24 gauge stranded fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. Bolt Calibration Size in. (mm) Part Number 4 in. x 28 UNF M6 x 48 (29) 7XSGA048A 96 (2438) 7XSGA096A 48 (29) 7XSGM048A 96 (2438) 7XSGM096A 7 X G Grounded unction 0.375 in. (9.5 mm) The nozzle thermocouple has a short installation depth and a low profile thus allowing control of thin sections of platens. ** Only available with 24 gauge wire. 7 = Nozzle thermocouple 3. Diameter X = Not applicable 5. Protection F = Fiberglass (24 gauge stranded) P = Fiberglass (20 gauge stranded) B = Fiberglass with stainless steel overbraid (20 gauge stranded) V = PFA (20 gauge stranded) W = PFA with stainless steel overbraid (20 gauge stranded) G = Grounded 7. 304 SS, Bolt size A = 4 inch x 28 UNF, 3 8 inch thread depth B = 8-32 thread * C = 0-32 thread * M = M6 x 8-0. (inches) 56

W A T L O W Pipe Clamp Style Rapid Ship sensors come with 24 gauge stranded fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. Clamp Calibration Size in. (mm) Part Number 6 to 4 4 to 2 4 48 (29) 72XSGA048A 96 (2438) 72XSGA096A 48 (29) 72XSGB048A 96 (2438) 72XSGB096A 0.5 in. (2.7 mm) Diameter The stainless steel clamp allows temperature measurement without drilling or tapping. Ideal for measuring pipe temperatures. 7 2 X G 72 = Pipe clamp thermocouple 3. Diameter X = Not applicable 5. Protection B = Fiberglass with stainless steel overbraid (20 gauge stranded) W = PFA with stainless steel overbraid (20 gauge stranded) G = Grounded 7. Clamp Band Diameter Range (inches) A= 6 to 4 E = 4 4 to 5 B= 4 to 2 4 F = 5 to 6 C= 2 4 to 3 4 G = 6 to 7 D= 3 4 to 4 4 8-0. (inches) 57

Grommet Style Rapid Ship sensors come with 24 gauge solid fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. Calibration in. (mm) Part Number 48 (29) 73XFGA048A 96 (2438) 73XFGA096A 7 3 X G A 73 = Grommet thermocouple 0.375 in. (9.5 mm) O.D. 0.96 in. (5 mm) I.D. ± 0.005 in. (0. mm) 3. Diameter X = Not applicable 5. Protection F = Fiberglass (24 gauge solid) T = PFA (24 gauge solid) G = Grounded 7. Grommet Size (inch) A = 0.95 inch I.D. x 0.375 inch O.D. x 0.035 inch thick 8-0. (inches) Extremely low profile of the stainless steel grommet provides fast response time. 58

W A T L O W Brass Shim Style 7 4 X G A 74 = Shim stock thermocouple 3. Diameter X = Not applicable = Type K = Type K T = Type T E = Type E 5 Protection F = Fiberglass (24 gauge solid) T = PFA (24 gauge solid) G = Grounded 7. Shim Size (inch) A = 2 inch x 5 8 inch x 0.06 inch, brass 8-0. (inches) 0.25 in. (6.4 mm) 0.25 in. (3.2 mm) 0.06 in. (0.4 mm) Brass Shim 0.625 in. (5.9 mm) 0.5 in. (2.7 mm) The shim stock thermocouple has low profile and can be placed between components for measurement of surface temperature. Available in other shim dimensions. Contact your Watlow sales representative for details. 59

Stainless Steel Shim Style Rapid Ship sensors come with 24 gauge solid fiberglass lead with stainless steel overbraid, grounded junction and a split lead termination. Calibration in. (mm) Part Number 48 (29) 75XSGA048A 96 (2438) 75XSGA096A 7 5 X G A 0.00 in. (0.3 mm) Stainless Steel Shim Stock 0.5 in. 0.25 in. (2.7 mm) (6.4 mm) 0.75 in. (9 mm) 0.75 in. (9 mm) The shim stock thermocouple has low profile and can be placed between components for measurement of surface temperature. Available in other shim dimensions. Contact your Watlow sales representative for details. 75 = Stainless steel shim stock thermocouple 3. Diameter X = Not applicable = Type K = Type K T = Type T E = Type E 5. Protection F = Fiberglass (24 gauge stranded) G = Grounded 7. Shim Size (inch) A = 3 4 inch x 3 4 inch x 0.00 inch, 304 stainless steel 8-0. (inches) 60

W A T L O W Kapton Bracket Style in. (25 mm) Aluminum Bracket Kapton 7 /8 in. (22 mm) Low Profile Kapton Peel and Stick Style in. /4 in. Kapton in. = 25 mm /4 in. = 32 mm Newbury Nozzle Style in. (25 mm) Side view of bracket /8 in. Dia. (3 mm) The Kapton thermocouple, when used with the aluminum bracket, has been designed primarily to measure roller temperature. By putting a light pressure on the roller, the Kapton thermocouple measures roller surface temperature without using slip rings. This type of set-up greatly reduces lag time and eliminates the cost of slip rings and their associated maintenance problems. 0.06 in. = 0.4 mm /4 in. = 6 mm /8 in. = 3 mm /2 in. = 3 mm 0.06 in. Rivet /4 in. C.L. for /8 in. R /2 in. 30 Low Profile Kapton Thermocouple (without Bracket) When used without the bracket it can be placed between heated parts for accurate temperature measurement. At the thermocouple junction, the overall thickness is only 0.06 in. (0.4 mm), so that it does not interfere with fit or thermo conductivity. Kapton Peel and Stick This sensor needs no bracket and no special mounting. Simply peel away the backing and this self-adhesive film will bond to almost any surface. Temperature ratings for continuous use is 200 C (400 F). A direct replacement for OEM Type nozzle thermocouples held in place with a set screw. The sheath is 8 inch diameter with a 90 degree bend and a spring strain relief. 24 Ga. Solid Conductors Fiberglass Insulation with Stainless Steel Overbraid It can also be used to measure conveyor belt temperatures or any other moving part by riding gently on the part surface. Continuous use at 200 C (400 F), 260 C (500 F) for limited periods Low mass Fast response Totally insulated construction Available in Type or K Kapton Thermocouple with Bracket Rapid Ship sensors with 30 gauge solid thermocouple wire, with fiberglass insulation and split lead termination. Calibration in. (cm) Part No. K 48 (22) OK30B4A 96 (244) OK30B4B 48 (22) OKK30B4A 96 (244) OKK30B4B Rapid Ship sensors with 30 gauge solid thermocouple wire, with fiberglass insulation and split lead termination. Calibration in. (cm) Part No. K 48 (22) OK30B2A 96 (244) OK30B2B 48 (22) OKK30BA 96 (244) OKK30BB Rapid Ship sensors with 30 gauge solid thermocouple wire, with fiberglass insulation and split lead termination. Calibration in. (cm) Part No. K T 48 (22) OK30BA 96 (244) OK30BB 48 (22) OKK30B0A 96 (244) OKK30B0B 48 (22) OKK30B2A 96 (244) OKK30B2B Ordering Information With 48 inch metal braided leads part no. 252A23D With 60 inch metal braided leads part no. 252A23E Kapton is a registered trademark of E.I. du Pont de Nemours & Company. Grounded unction 6

Melt Bolt Thermocouple Watlow plastic melt bolt thermocouples are designed so that the sensitive closed end portion of the tip can be inserted directly into the plastic stream of an extruder or injection molding machine. The measuring junction is thermally isolated from the metal bolt mass, assuring accurate reading of the melt temperature up to 260 C (500 F) continuous. Bolt is 300 series stainless steel. 62 E 0.325 in. (7.9 mm) A Immersion Depth Fixed Immersion Style M Flexible SS Armor E 0.325 in. (7.9 mm) A Immersion Depth n.) Is Field Adjustable Immersion Depth E 0.325 in. (7.9 mm) One Time Adjustable Immersion Style M2 Fixed Immersion with Flexible Extension Style M3 A 2 3 4 5 M A 0 2. Style = Fixed immersion 2 = Adjustable immersion 3 = Fixed immersion with flex armor 3. Sheath O.D. (inch) G = 0.25 4. Wire Construction O = No flex armor (M and M2) R = S.S. flex armor (M3 only) 5. Melt Bolt A (inch) = 3 2 = 6 6. Cold End Terminations A = Standard male plug B = Standard female jack C = Standard plug with mating connector T = Standard 2 inch split leads (Style M3 only) U = 2 inch split leads with spade lugs (Style M3 only) W= 2 inch split leads with BX connector and spade lugs (Style M3 only) 7. Probe Construction A = Mineral insulated with 304 SS sheath 8. Enter 0 9. Immersion I (inch) = 0. Immersion I (fractional inch) = 8 5 = 5 8 2 = 4 6 = 3 4 3 = 3 8 7 = 7 8 4 = 2 0 = Flush. unction U = Ungrounded G = Grounded 2. Calibration Standard limits K Special limits 3 4 3-4. Extension E 03, 06 Whole inches: 02 to 99 5. Special Requirements If none, enter 0. If required, consult factory 0.325 in. (7.9 mm) /2-20 UNF-3 Thread 0.5 in. (2.7 mm) 2.875 in. 55.6 mm A Dim. 45 0.25 in. (6.35 mm) 0.30 in. (7.9 mm) 0.5 in. (2.7 mm) Standard Dimensions For M, M2, and M3 Melt Bolts 0.307 in. / (7.8 mm) 0.49 in. 0.46 in. (0.6 mm) /(0.57 mm)