VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Similar documents
Directional Controls

Directional Controls

D03 FluiDyne Valves. ENGINEERING DATA

Directional Controls

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

Directional Controls

Directional Controls

Directional Controls

Proportional Valves. Proportional Two-Stage Directional Valves

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Sepehr Hydraulic Asia

Functional Symbols and Application Notes

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Pilot Operated Directional Valves

Directional Control Valves. Features. Application. Operation

Appendix ISO /03/05/07/08

Pilot Operated Directional Valves

Solenoid Operated Directional Valve

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Proportional Valves. Proportional solenoid valves for pressure and flow control

Directional Control Valves. General Description. Operation. Features

3/2 and 4/2 directional seat valves with solenoid actuation

Proportional Valves. Proportional Directional and Throttle Valves Solenoid Operated

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

Directional Controls

3/2 and 4/2 directional seat valves with solenoid actuation

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Vickers TM Proportional Directional Valves without Feedback. h y d r a u l i c s

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

Proportional Valves. Auxiliary Function Modules for Proportional Valves. Hydrostat, Parallel-Flow-Path, Pilot Shuttle and Tapping Modules

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Pressure Relief Valves

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

3/2 and 4/2 directional poppet valve with solenoid actuation

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. General Description. Operation. Features

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Directional Control Valves

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Application. Features. Operation

High Pressure, High Flow Rate Modular Valves

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

D05 Directional Control Valves

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

Pilot Operated Directional Valves

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

Directional Control Valves. Application. Features. Operation.

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Directional Controls

Directional Control Valves. Application. Features. Operation

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

9 Shaft type N = Metric, to DIN/ISO 3019, Part 2 and VDMA 24560, Part 1 Y = SAE models P*B5 to 15 only. Omit for 20 thru 90 models

Chapter 2: Directional Control Valves

Pump Safety Block Model DBA... / DBAW, Series 1X

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

4/2 Directional valve elements with or without secondary relief valves, with or without LS connections, and with 2/2 solenoid cartridge valve

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Directional Control Valves. Features. Application. Operation

Cartridge Valves. Proportional Valves Screw-in Cartridge Valves. Vickers. Maximum Pressure 280 bar (4000 psi) - Maximum Flow 160 l/min (42 USgpm)

Pressure relief valve, pilot-operated. Type DB and DBW. Features. Contents. RE Edition: Replaces:

Directional Control Valve Series 4D01 (DENISON)

Monobloc and Sectional Directional Control Valves

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

EManually Operated Directional Valves

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

4-way directional servo-valve

Directional Control Valves

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

01 SERIES MODULAR VALVES. Pub. EC-1402

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Directional Control Valve Series D1VW

Pilot-Operated Directional Control Valves Series D3 - D11

Proportional pressure reducing valve, in 3-way version

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

5 Port Solenoid Valve

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Transcription:

VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227

uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and a standard mounting surface. Reduce Cost SystemStak valves eliminate intervalve piping and leak-prone tube and pipe connections. Installed cost is less than when using conventional valves. Versatile and Easy to Install SystemStak valves have all the internal passages necessary to serve the directional valve topping them. Mounting surfaces and port patterns are to international standards: any valve conforming to ISO 441 size 3; NSI/93.7M size D3; NF-D3; CEO 3; and DIN 2434, NG6 mounting interface can be used with these SystemStak valves. Rugged and Reliable Internal working parts are produced from hardened steel and mounted in ductile (spheroidal graphite) iron bodies. Excellent reliability is ensured. Working parts are accessible without removing valves from an assembled stack. SystemStak Systems... Easy to Understand, Easy to Design SystemStak circuitry is best shown using slightly different symbols than those for traditional valve configurations. Each SystemStak symbol has the same basic form and size as shown in fig. 1. Figure 1 Figure 2 For ease of understanding, remember the directions of flow for each line, and that all four flow paths pass through each valve (see fig. 2). For clarity, directional valves are drawn vertically in SystemStak circuit diagrams (see fig. 3). Figure 4 Relief valves should normally be positioned next to the mounting surface (i.e. at the bottom of the stack). When both a flow control and a pilot operated check valve are required, it is recommended that the flow control valve be between the check valve and the actuator to prevent check valve chatter. Figure 5 Figure 3 Each station (valve stack) is a combination of functions. When designing and assembling SystemStak valves, care must be taken to ensure that they interact as required by stacking the functions in the correct sequence (fig. 4 is an example). combination of directional valve, SystemStak valve(s) and subplate/manifold block (fig. 5: single station subplate and fig. 6: multi-station manifold) completes the assembly. 2

SystemStak Systems... Easy to Understand, Easy to Design Figure 6 Fig. 7 represents a complete SystemStak system, showing typical use of functions available from this range. he circuit diagram also shows the use of a tapping plate for accessing line pressure readings, and a blanking plate to close off an unused station of a multi-station manifold. Figure 7 3

able of Contents Function asic symbol asic model Features age Relief DGMC Single, dual and crossport 5 models Counterbalance DGMR Control in port 9 Sequence DGMR1 Single port sequence 9 Reducing/relieving DGMX iloted from (and reduced pressure in) port, or 9 Direct check DGMDC Single check in any port; dual check in ports and only 13 ilot operated check DGMC Single in port or ; dual in ports and 16 Flow restrictor DGMFN Single or dual port, meter-in or meter-out 19 Further information: Mounting bolts, subplates and manifold blocks Hydraulic fluids Filtration requirements emperature limits ressure drop at other viscosities ypes H and K adjusters Warranty and repair Ordering procedure 22 Operating Data Maximum flow rate Maximum operating pressure ressure drops Mounting position Mass, pproximate: DGMC................ 1,3 kg (2.9 lb) DGMC2............... 2,5 kg (5.5 lb) DGMR(1).............. 1,3 kg (2.9 lb) DGMX................ 1,3 kg (2.9 lb) DGMDC................. 1 kg (2.2 lb) DGMC...............,8 kg (1.8 lb) DGMFN............... 1,1 kg (2.2 lb) 6 L/min (16 USgpm) 315 bar (45 psi) See graphs Optional 4

Relief Valves DGMC-3-4* DGMC2-3-4* General Description hese two-stage adjustable pressure relief valves limit the maximum pressure in the line(s) controlled by the integral relief valve elements. ypical Section ressure adjustment options of control knob (with or without keylock) or screw/locknut design are available. he two-stage operation is basically identical to long-established balanced piston valves, described in detail in Vickers Industrial hydraulics manual. Functional Symbols For simplicity these two-stage valves are represented as single-stage models Model Code for Relief Valves DGMC(2) -3- ** - * * (-* - * * )- * - 4* DGMC-3--** 1 2 3 4 5 6 7 8 9 DGMC2-3--**--** 1 ype 2 = Dual relief function Omit for single relief function 2 First function Single relief, or first line of dual models Code ressure Discharge Usage limited in into Single only Single, or dual with Single only Single, or dual with Single only DGMC-3--** DGMC2-3--**--** 3 ressure adjustment range, first function = 3-5 bar (43.5-725 psi) = 3-1 bar (43.5-145 psi) C = 1-2 bar (145-29 psi) G = 5-315 bar (725-45 psi) 4 ressure adjustment/ locking method, first function H = Handknob K = Micrometer with keylock W = Screw and locknut 5

Relief Valves DGMC-3-4* DGMC2-3-4* 5 Second function Second line of dual models Code ressure Discharge Usage limited in into Dual with Dual with erformance Characteristics ressure override ypical performance for models at max. pressure settings with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). psi bar Omit for single line models 5 35 6 ressure adjustment range, second function Options as in 3 7 ressure adjustment/ locking method, second function Options as in 4 ressure 4 3 2 1 3 25 2 15 1 5 8 Gage port: option on and single models only = G 1 / 4 ( 1 / 4 SF) S = SE 4 ( 7 / 16-2 UNF-2) lank = No gage port 1 2 3 4 5 6 L/min 4 8 12 16 USgpm Flow rate 9 Design number, 4 series Subject to change. Installation dimensions unchanged for design numbers 4 to 49 inclusive. 6

Installation Dimensions in mm (inches) DGMC(2)-3**-**(-*-**)-4* Models with type W adjuster o adjust valve setting slacken off locknut and turn adjuster screw. urn clockwise to increase pressure; counter-clockwise to decrease pressure Re-tighten locknut after completing adjustment. 79 (3.1) fully out max. Line adjustment Line or line adjustment (according to model type) max. 4 (.16) max. over gage port plug 4 (1.57) 2 (.79) 3,5 (.14) Ø3 (.12 dia) 4 ( 5 / 32 ) /F hex. socket 12,7 ( 1 / 2 ) /F hex. locknut orque to 25-3 Nm (18-22 lbf ft) 4 holes through: Ø5,3 (.21 dia) 4 off O seals supplied for this mounting face 47,6 (1.87) 46 (1.8) 39 (1.54) 76 (3) C max. D max. Model C D DGMC-3--*W-4* 154 (6.1) DGMC-3--*W-4* 156 (6.2) DGMC-3--*W-*-4* 16 (6.3) DGMC-3--*W-4* 156 (6.2) DGMC-3--*W-*-4* 16 (6.3) DGMC2-3--*W--*W-4* 234 (9.2) For gage port thread options see model code 8 7

Installation Dimensions in mm (inches) E max. Line adjustment Line adjustment 16,75 (.66) 16,75 (.66) 8 (.13) max. 1 (.4) max. F max. G max. Model E F G DGMC-3--*W-4* 164 (6.5) DGMC-3--*W-*-4* 164 (6.5) DGMC2-3--*W--*W-4* 234 (9.2) 8

ressure Controls: Counterbalance, Sequence and ressure Reducing Valves DGMR(1)-3-4* DGMX*-3-4* General Description hese single-stage valves operate by the application of pressure on the end of the valve spool, acting against a spring which is loaded by means of the adjustment mechanism. ypical Section In the counterbalance and sequence valves the spool is offset by the spring such that flow cannot pass through the valve. When the force exerted by the pilot pressure on the spool end exceeds the force of the main spring, the spool is moved to allow flow through the valve. In the pressure reducing valve the flow path is normally open and is closed as the pilot pressure exceeds the setting of the valve. Excessive pressure in the reduced-pressure line is prevented by a pressure relieving function. ressure adjustment options of control knob (with or without keylock) or screw/locknut design are available. Functional Symbols DGMR-3- DGMX*-3- DGMR1-3- DGMX*-3- DGMX*-3-9

Model Code for Counterbalance, Sequence and ressure Reducing Valves DGM *(*) -3- ** (*) - * * - * -4* 1 2 3 4 5 6 7 1 ype R = Counterbalance function R1 = Sequence function X1 = ressure reducing, underlapped X2 = ressure reducing, overlapped X3 = ressure reducing, overlapped, low leakage 2 Function ports For DGMR only: = Counterbalance control function in port, controlled by pressure in port For DGMR1 only: = Sequence control in port, controlled by pressure in port For DGMX only: = ressure reducing function in line, piloted from = ressure reducing function in line, piloted from = ressure reducing function in line, piloted from 6 S Gage port = G 1 / 8 ( 1 / 8 SF) = SE 4 ( 7 / 16-2 UNF-2) 7 Design number, 4 series Subject to change. Installation dimensions unchanged for design numbers 4 to 49 inclusive. 3 djuster location Option on DGMX only L = djuster at -port end of valve lank = djuster at -port end of valve 4 ressure adjustment range For DGMX only: Y = 1,4-7, bar (21-11 psi) R = 1,4-45, bar (21-652 psi) For DGMR and DGMX: = 3-3 bar (43.5-435 psi) = 3,5-7 bar (51-1 psi) C = 1-14 bar (145-2 psi) F = 2-25 bar (29-3625 psi) 5 ressure adjustment/ locking method H = Handknob K = Micrometer with keylock W = Screw and locknut 1

erformance Characteristics ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). DGMX*-3-* DGMR1-3- psi 4 bar 3 DGMX3-3 DGMX2-3 DGMX1-3 psi 4 bar 3 25 25 ressure 3 2 2 15 ressure 3 2 2 15 1 1 5 1 1 5 2 1 1 2 3 4 5 6 L/min 6 4 2 4 8 12 16 USgpm Reverse flow to line Reduced pressure line Flow rate 1 2 3 4 5 6 L/min 4 8 12 16 USgpm Flow rate DGMX*-3-* Low ressure/flow Rate Minimum erformance psi bar 1 7 Reduced pressure setting 8 6 4 2 6 5 4 3 2 1 1 2 3 4 5 6 L/min 4 8 12 16 USgpm Q max. Effect of ack-ressure he effective reduced pressure is equal to the valve adjustment setting plus any back-pressure in line Dead Head Leakage ypical leakage flow at 25 bar inlet pressure from reduced pressure line into at Dead Head condition (i.e. No flow required at the reduced pressure outlet.) his leakage flow must be provided at the inlet line in order to maintain the reduced outlet pressure. DGMX1-3 = 16 DGMX2-3 = 4 DGMX3-3 = 8 11

Installation Dimensions in mm (inches) DGMR-3--**-*-4* DGMR1-3--**-*-4* DGMX(*)-3-*(L)-**-*-4* Models with type W adjuster o adjust valve setting slacken off locknut and turn adjuster screw urn clockwise to increase pressure; counter-clockwise to decrease pressure. Re-tighten locknut after completing adjustment. DGMX2-3-**L models have adjuster and end cap/gage port locations interchanged from positions shown. 4 (1.57) 2 (.79) 4 ( 5 / 32 ) /F hex. socket 3,5 (.14) Ø3 (.12 dia) 12,7 ( 1 / 2 ) /F hex. locknut orque to 25-3 Nm (18-22 lbf ft) 4 holes through: Ø5,3 (.21 dia) 4 off O seals supplied for this mounting face 47,6 (1.87) 46 (1.8) 14 (.55) max. 39 (1.54) 76 (3) 8 (3,1) max. For gage port thread options see model code 6, (pressure plug fitted) 12

Direct Check Valves DGMDC-3-4* General Description hese valves allow free flow in one direction in the line in which the check valve element(s) is (are) located; flow in the opposite direction is not possible. ypical Section Functional Symbols DGMDC-3-X-* DGMDC-3-Y-* Model Code for Direct Check Valves DGMDC-3- * -* *(- * * )- 4* 1 2 3 4 5 6 DGMDC-3-X-* DGMDC-3-Y-* DGMDC-3-Y-* DGMDC-3-X-* DGMDC-3-Y-*-* 1 Direction of flow X = Free flow away from actuator Y = Free flow towards actuator 2 Check location = line = line = line; with Y in = line; with X in 3 Check valve opening/cracking pressure K = 1 bar (14.5 psi) M = 2,5 bar (36 psi) N = 5 bar (72 psi) 4 Check location (second element of dual model) Only available as model type DGMDC-3-Y-*-*-4* = line 5 Check valve opening/cracking pressure (second function of dual model) Options as in 3 1 1 6 Design number, 4 series Subject to change. Installation dimensions unchanged for design numbers 4 to 49 inclusive. 13

erformance Characteristics ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C(122 F) ressure drop: free flow through check valve ressure drop psi 4 3 2 1 bar 3 27 24 21 18 15 12 9 6 3 1 2 3 4 5 6 L/min 4 8 12 16 USgpm Flow rate For other viscosities, see Further Information. Internal Leakage cross Closed Check Valve Less than,25 ml/min (.15 in 3 /min) at 25 bar (3625 psi) 14

Installation Dimensions in mm (inches) DGMDC-3-Y-*-*-4* DGMDC-3-X-*-4* DGMDC-3-X-*-4* DGMDC-3-Y-*-4* DGMDC-3-Y-*-4* 11 (4) max. 13 (.51) 4 (1.57) H H 3,5 (.14) Ø3 (.12 dia) 12 (.47) 88 (3.46) max. 4 holes through: Ø5,3 (.21 dia) 4 off O seals supplied for this mounting face DGMDC-3-X-*-4* DGMDC-3-Y-*-4* 47,6 (1.87) 46 (1.8) H 39 (1.54) 76 (3) 13 (.51) 89 (3.5) max. Model type DGMDC-3-X-*-4* DGMDC-3-X-*-4* DGMDC-3-Y-*-4* H 16,75 (.66) DGMDC-3-X-*-4* DGMDC-3-Y-*-4* 23,25 DGMDC-3-Y-*-4* (.92) DGMDC-3-Y-*-*-4* 15

ilot Operated Check Valves DGMC-3-4* General Description hese valves provide pilot operated check functions in one or both service lines ( or ), the operating pilot supply coming from the opposite service line. hus with pressure in one service line the check valve in the other service line will be open (subject to system/actuator pressures being correct for the valve area ratios). ypical Section 3:1 area ratio of pilot piston to check valve seat is supplemented by an optional 1:1 decompression feature. Functional Symbols DGMC-3-(D)*-(D)* Model Code for ilot Operated Check Valves DGMC-3-(D) ** * [-(D)** *] - 4* 1 1 1 2 3 4 5 6 7 DGMC-3-(D)* 1 1 DGMC-3-(D)* 1 1 1 Decompression feature D = 1:1 decompression ratio Omit if not required 2 Function = Check in line, pilot operated from line = Check in line, pilotoperated from line (single check model only) 3 Check valve opening/cracking pressure K = 1 bar (14.5 psi) M = 2,5 bar (36 psi) N = 5 bar (72 psi) 6 Check valve opening/cracking pressure (second function of dual models) Options as in 3 Omit for single line models 7 Design number, 4 series Subject to change. Installation dimensions unchanged for design numbers 4 to 49 inclusive. 4 Decompression feature (second function of dual models) s in 1 Omit for single line models,and if not required for dual models Note: D must be specified here, for dual models, if called for in 1 5 Second function of dual models = Check in line, pilot operated from line Omit for single line models 16

erformance Characteristics ressure Drop Data ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C(122 F) u ressure drop: flow path 1 to or 1 to (no pilot-pressure operation) ressure drop: flow path to 1, or to 1 with check valve pilot-operated fully open psi 4 bar 3 27 24 psi bar 25 ressure drop 3 2 1 21 18 15 12 9 6 3 1 2 3 4 5 6 L/min ressure drop 3 2 1 2 15 1 5 1 2 3 4 5 6 L/min 4 8 12 16 USgpm Flow rate 4 8 12 16 USgpm Flow rate u For other viscosities see Further Information. ilot ressures ilot area ratios: Main check valve................ 3:1 Decompression poppet.......... 1:1 Use applicable ratio and opening/ cracking pressure to calculate pilot pressure to open valve element, applied to the following formulae: o open valve or decompression poppet in line : p p C p 1 ressure at 1 = rea ratio factor + p 1 o open valve or decompression poppet in line : p p C p 1 ressure at 1 = rea ratio factor + p 1 Where: p = ressure at p C = Cracking/opening pressure p 1 = ressure at 1 p = ressure at p 1 = ressure at 1 = = 1= Service line location; see functional symbols 1= Leakage Less than,25 ml/min (.15 in 3 /min) at 25 bar (3625 psi). 17

Installation Dimensions in mm (inches) DGMC-3-(D)*-(D)*-4* DGMC-3-(D)*-4* 11 (4) max. 13 (.51) 4 (1.57) 23 (.9) 3,5 (.14) Ø3 (.12 dia) 12 (.47) 97 (3.82) 4 holes through: Ø5,3 (.21 dia) 4 off O seals supplied for this mounting face DGMC-3-(D)*-4* 47,6 (1.87) 46 (1.8) (1) (1) 39 (1.54) 76 (3) 97 (3.82) 13 (.51) 18

Flow Restrictor Valves DGMFN-3-4* General Description hese valves regulate flow by means of an adjustable orifice which is not pressure compensated, and flow through the valve is entirely dependent upon pressure drop at any particular setting of the orifice. Dual service-line models with an integral non-return valve around each control orifice provide for meter-in or meter-out control; single line versions of these are available. For flow restriction in or lines (where reverse free flow is not required) models without check valves are available. djustment options are either screw/locknut or handknob. ypical Section Model Code for Flow Restrictor Valves DGMFN-3- * -* * * (- * * * )-4* Functional Symbols 1 2 3 4 5 6 7 8 DGMFN-3-X-**-** DGMFN-3-Y-**-** DGMFN-3-Z-** 1 Direction of flow control (with respect to machine actuator) X = Meter-in control, applicable to lines and Y = Meter-out control, applicable to lines and Z = Meter-in control, line only and meter-out control, line only. 2 Location of control function (single model or first line of dual model) = Line (single model only) = Line (single model only) = Line (single model or first line of dual model) = Line (single model only) 6 ype of control needle/orifice (second line of dual models) Options as in 3 Omit for single models 7 djuster type (second line of dual models) Options as in 4 Omit for single models 8 Design number, 4 series Subject to change. Installation dimensions unaltered for design numbers 4 to 49 inclusive. DGMFN-3-Z-** 3 ype of control needle/orifice (single model or first line of dual model) 1 = Fine control 2 = Standard control 4 djuster type (single model or first line of dual model) H = Handknob W = Screw/locknut 5 Control in second line = Line (use for dual models with specified at 2 ) Omit for single models 19

erformance Characteristics ressure Drop ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C(122 F) ype 1 needle (see model codes 3 and 6 ) ype 2 needle (see model codes 3 and 6 ) psi 8 bar 6 5 Number of turns of adjuster 1 2 3 4 5 6 psi 8 bar 6 5 Number of turns of adjuster 1 2 3 4 ressure drop 6 4 2 4 3 2 1 ressure drop 6 4 2 4 3 2 1 5 6 1 2 3 4 5 6 L/min 1 2 3 4 5 6 L/min 4 8 12 16 USgpm Flow rate 4 8 12 16 USgpm Flow rate Free flow through check valve ressure drop psi 2 15 1 5 bar 14 12 1 8 6 4 2 1 2 3 4 5 6 L/min 4 8 12 16 USgpm Flow rate For other viscosities see Further Information. 2

Installation Dimensions in mm (inches) DGMFN-3-X-***(-***)-4* DGMFN-3-Y-***(-***)-4* DGMFN-3-Z-***-4* Models with type W adjuster o adjust valve setting, slacken off locknut and turn screw. Re-tighten locknut after completing adjustment. Line or line adjustment (according to model type) Line or line adjustment (according to model type) 4 ( 5 / 32 ) /F hex. socket 12,7 ( 1 / 2 ) /F hex. locknut. orque to 25-3 Nm (18-22 lbf ft) max. D max. max. 47 (1.85) max. 4 (1.57) E max. E max. 3,5 (.14) Ø3 (.12 dia) 4 holes through: Ø5,3 (.21 dia) 4 off O seals supplied for this interface 47,6 (1.87) 46 (1.8) 39 (1.54) 45 (1.8) max. 76 (3) C max. ype H adjuster urn clockwise to decrease flow (increase restriction); counter-clockwise to increase flow (reduce restriction). Ø32 (1.26 dia) M4 locking screw 2 ( 5 / 64 ) /F hex. socket 56 (2.2) max. Model C D E DGMFN-3-X-*W-4* 121 (4.76) 16,75 (.7) DGMFN-3-X-*W-*W-4* 167 (6.6) 16,75 (.7) DGMFN-3-X-*W-4* 122 (4.8) 16,75 (.7) DGMFN-3-Y-*W-4* 121 (4.76) 23,25 (.9) DGMFN-3-Y-*W-*W-4* 167 (6.6) 23,25 (.9) DGMFN-3-Y-*W-4* 122 (4.8) 23,25 (.9) DGMFN-3-Z-*W-4* 123 (4.8) 16,75 (.7) DGMFN-3-Z-*W-4* 123 (4.8) 23,25 (.9) 21

Further Information Mounting olts, Subplates and Manifold locks Mounting olts he length of mounting bolt used to install a SystemStak assembly is dependent on the number of valves being used, plus the length needed for mounting other valves in the assembly, such as: solenoid operated, or other type of directional valve tapping plate blanking or crossover plate. Vickers offers a large selection of bolt kits (one bolt kit for these SystemStak valves comprises 4 bolts) in metric and inch sizes as listed. o determine your needs, use the following guide for bolt length calculation. = olt clamp length in directional valve, blanking plate, crossover plate, etc. = Height of intermediate valve stack, comprising Vickers SystemStak valve(s) plus tapping plates, etc. C = Depth of thread engagement in sub-plate/ manifold block: 8/1 mm (.3/.4 ), valid for: 315 bar (45 psi) when using cast iron or steel subplates/manifold blocks, or 21 bar (345 psi) when using Vickers aluminium alloy manifold blocks. L = Required bolt length; select from the table. Notes 1. olts should be torqued to 7-9 Nm (63-8 lbf in) with threads lubricated. 2. If not using Vickers bolt kits, bolts must be to Grade 12.9 (ISO 898) or better. C L olt Kit Selection Metric: M5-6g Inch: 1-24 UNC-3 Length Vickers bolt Length Vickers bolt (mm) kit number (in) kit number 5 KDG3699M 2. KDG3698 6 K466836M 2.375 K466849 7 K464125M 2.75 K8717 8 K466837M 3.125 K46685 9 K466838M 3.5 K466851 1 K466839M 3.937 K466852 11 K46684M 4.312 K466853 12 K466841M 4.75 K466854 13 K466842M 5.125 K466855 14 K466843M 5.5 K466856 15 K466844M 5.937 K466857 16 K466845M 6.312 K466858 17 K466846M 6.687 K466859 Subplates and Manifold locks See Subplates and uxiliary Connection lates catalog 2425. Hydraulic Fluids Materials and seals used in these valves are compatible with : nti-wear petroleum oils........ L-HM Water glycols................ L-HFC Invert emulsions.............. L-HF Non-alkyl based phosphate esters............. L-HFD he extreme operating range is 5 to 13 cst (27 to 7 SUS) but the recommended running range is 54 to 13 cst (245 to 7 SUS). For further technical information about fluids see 694. Filtration Requirements Recommendations on filtration methods and the selection of products to control fluid condition are included in Vickers publication 561 or 9132. For products in this catalog the recommended fluid cleanliness levels are: Up to 21 bar (35 psi)..... 18/16/13 bove 21 bar (35 psi).... 17/15/12 emperature Limits mbient range Fluid temperatures....... 2 C to +8 C ( 4 F to +176 F) Water- containing etroleum oil Min. 2 C +1 C ( 4 F) (+5 F) Max.* +8 C +54 C (+176 F) (+129 F) * o obtain optimum service life from both fluid and hydraulic system, 65 C (15 F) is the recommended maximum fluid temperature, except for water-containing fluids. For other fluids where limits are outside those of petroleum oil, consult fluid manufacturer or Vickers representative. Whatever the actual temperature range, ensure that viscosities stay within those specified under Hydraulic Fluids. 22

Further Information ressure Drop at Other Viscosities ublished pressure drop data is valid for a fluid viscosity of 21 cst (12 SUS). he graph shows the approximate percentage change in pressure drop for a range of other viscosities. o determine the approximate pressure drop for any given fluid viscosity, multiply the published data by the % factor for the required viscosity. % Factor 16 14 12 1 8 15 25 35 45 55 65 75 85 cst 75 1 15 2 25 3 35 4 SUS Viscosity ype H djuster o adjust valve setting, slacken M4 locking screw and rotate knob. Re-tighten locking screw after completing adjustment. vailable on DGMC-3 DGMR-3 DGMX-3 89 (3.5) max. Ø32 (1.26 dia) M4 locking screw 2 ( 5 / 64 ) /F hex. socket ype K djuster Key must be inserted and turned to allow valve to be adjusted. When key is removed, adjustment mechanism can be freely turned without changing valve setting. vailable on DGMC-3 DGMR-3 DGMX-3 115 (4.5) max. 25 (1) Ø32 (1.26 dia) 18 (.71) for key removal urn clockwise to increase pressure; counter-clockwise to decrease pressure Spare arts Valves are sold complete with all seals. art numbers for available spare seal kits: DGMC-3-4/41.............. 87738 DGMC2-3-4/41............. 87737 DGMR(1)-3-4/41........... 87739 DGMX(*)-3-4/41............ 87739 DGMDC-3-4/41............ 8778 DGMC-3-4/41............ 8778 DGMFN-3-4/41............. 8777 Note: Seal kits cover various model options for the respective types. Redundant seals will be found for some models. Warranty and Repair Units to be returned under warranty should be sent, with a description of the fault, to the Vickers representative in your area. Repair of these size 3 valves is not generally economically viable. Contact your nearest Vickers representative before returning any unit for repair. Ordering rocedure Specify requirements by valve model code, and by seal kit number. 23

Vickers Solenoid Operated Directional Valves Catalog DG4V-3 flows to 8 l/min (21 USgpm), 6* design DG4V-3S flows to 4 l/min (1.5 USgpm), 6* design ISO 441, size 3; NSI/ 93.7M-D3

able of Contents Introduction 1 Features and enefits 2 Characteristics 3 Functional Symbols 4 Model Code 5 Operating Data 7 erformance Data 9 Installation Dimensions 12 DG4V-3-*(L)-(V)M-S6-U-**-6 14 DG4V-3-*(L)-(Z)-(V)M-S3-F5W-*2-6 14 DG4V-3-*(L)-(Z)-(V)M-S4-F5W-*2-6 14 DG4V-3-*(L)-(Z)-(V)M-S5-F-*2-6 14 Electrical lugs and Connectors 15 Subplates, Connection lates and Mounting Surfaces 18 DGM-3--1* lanking late 19 DGM-3-C2-11 Crossover late 19 DGM-3-*-1*-* apping late 19 DGM-3-1-1*-R (Metric bolt tapping) DGM-3-1-1* (UNC bolt tapping) 2 daptor plate, Size 5 to 3 for pressure up to 21 bar (3 psi) 2 DGVM-3-1*-*, DGMS-3-1E(Y)-1*-* Single station subplate, rear and side tapped port 21 DGMS-3-3E-1*-* Multi-station subplate 22 Mounting Surface 23 ppendix 24 Mounting olts 24 Spare arts Data 25 Seal Kits 25 Solenoid Coils 25 Mass, approx. kg (lb) 25 Mounting ttitude 25 emperature Limits 26 Fluid emperature 26 Fluid Cleanliness 26 Ordering rocedure 26

Introduction General description hese solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. his 6-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs. Some of the more important benefits to users are outlined. Efficient control of greater hydraulic powers without increasing solenoid power consumption. Installed cost and space savings from higher power/weight-and-size ratios. Increases system efficiency; the result of improved manufacture of spools and bores. Installation flexibility resulting from choice of numerous combinations of solenoid connectors and locations. Multi-fluid capability without need to change seals. Higher sustained machine productivity and higher uptime because of proven fatigue life and endurance, tested over 2 million cycles. Solenoid coils can be changed quickly and easily without leakage from hydraulic system. Compact, cost effective system design when used with Vickers SystemStak valves and subplates. DG4V-3 and DG4V-3S High and standard performance models: Up to 8 l/min (21 USgpm) and up to 4 l/min (1.5 USgpm) respectively at 35 bar (5 psi). uilds on Eaton's experience as the major supplier of size 3 valves worldwide. Offers designers the opportunity to select the optimum value package for each application. International standard interface. he valve mounting face conforms to ISO 441, size 3 and is compatible with related international standards. Features and enefits High pressure and flow capabilities, thanks to special design features Highly reliable operation up to 8 l/min (21 USgpm) at 35 bar (5 psi). Establishes new market standards and opens new possibilities to design engineers on valve size selection. ressure differential (bar) 4 3 2 1 Flow rate (USgpm) 4 8 12 16 2 21 1 2 3 4 5 6 7 8 Flow rate (l/min) DG4V-3S 5 4 3 2 145 ressure differential (psi) DG4V-3 ypical maximum pressure differential (---) flow envelope, blocked center spool. Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28 1

Features and enefits Minimal pressure drop, i.e. 2,5 bar (36 psi) at 3 l/min (7.9 USgpm) chieved by optimization of the valve body, spool and spool-stroke design. he results: low energy consumption and improved efficiency. ressure differential bar Flow rate (USgpm) 3 6 9 12 15 18 21 14 2 12 1 15 8 6 1 4 2 5 1 2 3 4 5 6 7 8 Flow rate (l/min) DG4V-3S DG4V-3 Mounting surface to ISO 441 size 3 ressure differential psi High reliability Design of spring forces and profile of DC solenoid force characteristics ensure spool position selection under extreme operating conditions. Result is a valve with high reliability when being energized or de-energied. Force erformance leader Solenoid energized Vickers solenoid force Normal solenoid force range on the market Vickers spring force Normal spring force range on the market Solenoid de-energized Electrical connections Conduit box design that simplifies electrical wiring connections to solenoids. Orientation tabs prevent incorrect positioning. Scratch-proof manual override seal Internal seals are located such that they are beyond reach of any bore damage caused by small tools used to operate the manual override. Result is no messy oil drips from the manual overrides. Small diameter manual overrides prevent inadvertent operation. DG4V-3 High erformance DG4V-3S Standard erformance Ease of servicing Wet-armature solenoid, screw-in core tube design allows coils to be changed without removing valve from installation and without oil spillage or risk of contaminating system fluid. ISO44 (DIN 4365) coil shown Surge supression for DC valves Surge suppression is used to prevent coil damage by reducing contact burnoff increasing switch life and protecting electrical controllers from inductive spikes. hree coil options are available: D1 Encapsulated diode (Industrial application) D2 Encapsulated diode (Mobile application) D7 ranszorb type 2 Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28

Characteristics High performance DG4V-3, 6* design Standard performance DG4V-3S, 6* design Mounting interface ISO 441 size 3 NSI/93.7M size D3 CEO R65H, size 3 DIN 2434, NG6 asic characteristics Maximum pressure: DG4V-3 35 bar (575 psi) DG4V-3S 35 bar (575 psi) Maximum flow: DG4V-3 up to 8 l/min (21 USgpm) DG4V-3S up to 4 l/min (1.5 USgpm) DG4V-3 models are direct solenoid operated four-way directional control valves. heir primary function in a hydraulic circuit is to direct fluid flow. his, in turn, would determine the direction of movement of a fluid cylinder, or the direction of rotation of a fluid motor. ort connections are made by mounting the valve on a subplate or manifold. he valve has wet armature type solenoids. Electrical connections to the valve are made in the electrical wiring housing or thru various plug-in connectors such as a DIN 4365 type coil. Good hydraulic design practice suggests that detented models be mounted with longitudinal axis horizontal. Other models may be mounted in any position. Operating considerations 1. Dependent on the application and the system filtration, any sliding spool valve if held shifted under pressure for long periods of time, may stick and not move readily due to fluid residue formation. It may therefore need to be cycled periodically to prevent this from happening. 2. Surges of fluid in a common tank line serving two or more valves can be of sufficient magnitude to cause inadvertent shifting of these valves. his is particularly critical in no-spring detented models, separate drain lines are necessary. Fluid temperature emperature limits Minimum ambient -2 C (-4 F) Maximum ambient Valves with coils listed in model code and at stated percentages of rated voltage. Construction of a typical single solenoid model Fluid emp. Mineral oil Watercontaining Min 2 C (-4 F) +1 C (+5 F) Max.* +7 C (+158 F) +54 C (+129 F) * o obtain optimum service life from both fluid and hydraulic system, 65 C (15 F) normally is the maximum temperature except for watercontaining fluids. Coil type and percentage Maximum ambient temperature frequency VoltagE dg4v-3 DG4V-3S Dual frequency coils @ 5 Hz 17% 4 C (14 F) 65 C (149 F) @ 5 Hz 11% 3 C (86 F) 65 C (149 F) @ 6 Hz 17% 5 C (122 F) 65 C (149 F) @ 6 Hz 11% 4 C (14 F) 65 C (149 F) Single frequency (5 Hz) coils @ 5 Hz 11% 4 C (14 F) 65 C (149 F) DC coils 11% 7 C (158 F) 7 C (158 F) For synthetic fluids consult manufacturer or Eaton representative where limits are outside those for mineral oil. Whatever the actual temperature range, ensure that viscosities stay within the limits specified in the Hydraulic fluids section. Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28 3

Functional Symbols U.S. solenoid standard Double solenoid valves, two position, detented Single solenoid valves, solenoid at port end Single solenoid valves, solenoid at port end Spool types shown represent the highest proportion of market requirements. For other spool functions that may be required, consult your Eaton sales representative. Solenoids identified to U.S. standards Functional symbols related to solenoid identity and/or according to NF/NSI standards, i.e. energizing solenoid gives flow to, solenoid gives flow to (as applicable). Sol. Sol. Double solenoid valves, spring centered Sol. Sol. s ransient condition only he valve function schematics apply to both U.S. and European valves. DG4V-3(S)-*N(V) 2 Sol. DG4V-3(S)-*(V) 2 22 24 DG4V-3(S)-*L(V) 2 22 24 Sol. ort ort DG4V-3(S)-*C(V) DG4V-3(S)-*/F(V) DG4V-3(S)-*L/FL(V) Solenoid Solenoid ort ort For Spool Solenoid type Solenoid ll except 8 8 only For valves with type 8 spools, solenoid identity to U.S. convention is the same as for European convention. Solenoids identified to European standards (specify V in model code) Functional symbols related to solenoid identity and/ or according to European convention i.e. solenoid adjacent to port, solenoid adjacent to port of valve. ort Solenoid ort Solenoid ort ort For differences in valve function, refer to erformance Data page 11. F build spools. 2 6 66 7 22 33 34 52 56 DG4V-3(S)-8C(V) European solenoid standard Double solenoid valves, two position, detented Double solenoid valves, spring centered Sol. Sol. s ransient condition only 2 6 66 7 22 33 34 521 561 DG4V-3(S)-8L(V) 8 8 8 Single solenoid valves, solenoid at port end Sol. Sol. Sol. 2 6 66 7 22 33 34 52 56 DG4V-3(S)-8(V) Single solenoid valves, solenoid at port end Sol. 4 Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28

Model Code DG4V 3(S) ** *(L) (**) (V)M (S*) * ** * D* (L) * * 6* (EN***) (** ** ** **) 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 1 Model Series D Directional valve G Subplate/manifold mounted 4 Solenoid operated V ressure rating 35 bar (575 psi) on, & ports 2 Standard or high performance 3 High performance specification: up to 8 l/min (21 USgpm) at 35 bar (575 psi) 3S Standard performance specification: up to 4 l/min (1.5 USgpm) at 35 bar (575 psi) 3 Spool type See Functional symbols section. 4 Spool Spring rrangement Spring offset, end-to-end L Same as but left hand build Spring offset, end to center L Same as but left hand build C Spring centered F Spring offset, shift to center FL Same as F but left hand build N No-spring detented 5 Manual override option No symbol lain override(s) in solenoid end(s) only s H Water-resistant override(s) on solenoid end(s) s H2 Water-resistant override both ends of solenoid. 2 lain override both ends of single solenoid. Y l Latching manual override on solenoid ends (includes H feature seal) s Z No overrides at either end s No override in non-solenoid end of single solenoid valves l Not available on DG4V-3S, C models 6 Solenoid energization identity V Solenoid is at port end and/ or solenoid is at port end, independent of spool type Omit for U.S. NSI 93.9 standard requiring solenoid energization to connect to and/or solenoid to connect to, independent of solenoid location. NOE: ype 8 spool valves conform to both U.S. and European solenoid designations. When ordering an 8 spool, designate a V in the model code. 7 Flag symbol M Electrical options and features 8 Spool indicator switch vailable on high performance models, DG4V-3, only. Omit when not required. DG4V-3-*(L)-(V)M models with type U (ISO44) electrical connector to solenoid; spool type, 2 or 22 only: S6 LVD type DC switch with g7 connector plug. DG4V-3-*(L)-(Z)-(V)M-S*-F5W valves with mechanical type C (~) switch, wired to 5-pin receptacle: S3 Switch, wired normally open S4 Switch, wired normally closed DG4V-3-*(L)-(Z)-(V)M-S5-F() W/J valves with mechanical type C (~) switch: S5 Switch, free leads 9 Coil type U ISO 44 (DIN 4365) mounting u U1 Connector fitted U6 Connector fitted w/lights U11 Connector fitted w/rectifier & lights** U12 Connector fitted w/rectifier** F 1/2" N thread conduit box KU op exit flying leads* S1 Single 6,3 mm spade* u S2 Dual 6,3 mm spade* u X1 Flame resistant solenoids EEx-d-11-4 X2 Hazardous location solenoids to meet UL & CS approval X3 Special protection solenoids to SEEF standar SF9:1972, protection class EX-S-11-4 u Female connector to be supplied by customer * DC service only ** C service only 1 Electrical connector Wired terminal block Instaplug male receptacle only Instaplug male & female receptacle 3 hree pin connector 5 Five pin connector 11 Housing (F type coils only) W 1/2" N thread wiring housing J 2 mm thread wiring housing 12 Surge suppressor/ damper D1 Encapsulated diode (Industrial applications) D2 Encapsulated diode (Mobile applications) D7 ranszorb type (F,KU,U,S1,S2 only) 13 Solenoid indicator lights Not available on, KU, U, S1& S2 14 Coil rating Full power coils, see Operating Data. 11V C 5Hz 11V C 5Hz/12V C 6 Hz C 22V C 5 Hz D 22V C 5 Hz/24V C 6 Hz G 12V DC H 24V DC For DG4V-3 only (not usable with DG4V-3S): Low power coils, see Operating Data. (Not available with N No-spring detented models) L 11V 5 Hz/12V 6 Hz DL 22V C 5 Hz/24V C 6 Hz GL 12V DC HL 24V DC For 6 Hz or dual frequency Contact your Eaton representative for additional coil voltage options. Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28 5

Model Code DG4V 3(S) ** *(L) (**) (V)M (S*) * ** * D* (L) * * 6* (EN***) (** ** ** **) 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 15 ort code Refer to Operating Data for port pressure ratings. 2 1 bar (15 psi) for spool position indicator models S3, S4 and S5. 4 7 bar (1 psi) 5 1 bar (15 psi) for standard performance models, DG4V-3S, with C or DC solenoids. 6 27 bar (3 psi) for C high performance models, DG4V-3, including spool position indicator type S6. 7 27 bar (3 psi) for DC high performance models, DG4V-3, including spool position indicator type S6. 17 Special features EN*** code number assigned as required. EN21 CS approved models with 1/2 N entry conduit box, type FW and solenoid coil letter,d,g, or H. 18 ort restrictor plugs For details of plug orifice sizes and how to specify in model code see page 15. May be fitted to valves by agreement with your Eaton representative. Omit No restrictor plugs fitted 16 Design number 6 asic design 61 ype 8 spool 6 Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28

Operating Data erformance data is typical with fluid at 36cSt (168 SUS) and 5 C (122 F). Standard performance valve High performance valve FeaturE dg4v-3s dg4v-3 ressure Limits, and ports 35 bar (575 psi) n 35 bar (575 psi) port: Spool indicator switch models ypes S3, S4, S5 N/ 1 bar (145 psi) ype S6 N/ 21 bar (345 psi) ll other models 1 bar (145 psi) 21 bar (345 psi) Flow rating See performance data See performance data Relative duty factor Continuous; ED = 1% Continuous; ED = 1% ype of protection: ISO 44 coils with plug fitted correctly IEC 144 class I65 IEC 144 class I65 S1 Single spade 6,3 mm IEC 76 IEC 76 S2 Dual spade 6,3 mm IEC 76 IEC 76 Coil winding Class H Class H Lead wires (coils type F***) Class H Class H Coil encapsulation Class F Class F ermissable voltage fluctuation: Maximum Refer to temperature limits. Refer to temperature limits. Minimum 9% rated 9% rated ypical response times at 1% rated volts measured from application/removal of voltage to full spool displacement of 2C spool at: Flow rate -, - 2 l/min (5.3 USgpm) 4 l/min (1.6 USgpm) ressure 175 bar (2537 psi) 175 bar (2537 psi) C (~) energizing 18 ms 15 ms C (~) de energizing 32 ms 23 ms DC (=) energizing 6 ms 45 ms DC (=) de energizing 4 ms 28 ms ower consumption, C solenoids Initial s Holding Initial s Holding (for coils listed in model code). V (RMS) V (RMS) V (RMS) V (RMS) Full power coils: Single frequency coils C 5 Hz 225 39 265 54 Dual frequency coils at 5 Hz 265 49 28 61 Dual frequency coils at 6 HZ 26 48 3 58 Low power coils, L and DL : (Not available with N No-spring detented models) Low power coils not usable 17 37 Dual frequency coils at 5 Hz with DG4V-3S valves. 19 37 Dual frequency coils at 6 Hz ower consumption, DC solenoids at rated voltage and 2 C (68 F). Full power coils: 12V, model type G 3W 3W 24V, model type H 3W 3W Low power coils: 12V, model type GL Low power coils not usable 18W 24V, model type HL with DG4V-3S valves. 18W n For applications where valves are to remain pressurized (either energized or de-energized) at pressures over 21 bar (345 psi) without frequent switching, it is recommended to use the high performance model, DG4V-3. s 1st half cycle; armature fully retracted. Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28 7

Operating Data Spool osition Indicator Models, high performance valve DG4V-3 ONLY Spool/spring arrangement types (L), 2(L), 22(L) DC model type S6 (see page 14 for Installation Dimension) his product has been designed and tested to meet specific standards outlined in the European Electromagnetic Compatibility. Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. For instructions on installation requirements to achieve effective protection levels see this leaflet and the Installation Wiring ractices for Eaton's Vickers Electronic roducts leaflet 2468. Wiring practices relevant to this Directive are indicated by Electromagnetic Compatibility (EMC). Input: Supply voltage 1 to 35V DC inclusive of a maximum 4V pk-to-pk ripple Current, switch open 5 m Current, switch closed 255 m Output: Voltage 1V below input at maximum load Maximum continuous current 25 m Maximum load impedance 136Ω at maximum input volts Maximum switching frequency 1 Hz lug connections: in 1 (output 1) Normally open (ie. not connected to pin 3) in 2 Supply +ve in 3 V in 4 (output 2) Normally closed (ie.connected to pin 3) Switching point Within the spool spring offset condition Connector g7 plug (supplied with valve) rotection Overload and short-circuit protected; self re-setting. IEC 144 class I65 with connector correctly fitted. Factory setting ensures this condition under all combinations of manufacturing tolerance and of temperature drift (see emperature Limits ). Wiring Connections Electric panel Warning ll power must be switched off before connecting or disconnecting any plugs Customer s protective ground connection LVD Solenoid WRNING: Electromagnetic Compatibility (EMC) It is necessary to ensure that the unit is wired up in accordance with the connection arrangements shown above. For effective protection the user s electrical cabinet, the valve subplate or manifold and the cable screens should be connected to efficient ground points. In all cases both valve and cable should be kept as far away as possible from any sources of electromagnetic radiation such as cables carrying heavy current, relays and certain kinds of portable radio transmitters, etc. Difficult environments could mean that extra screening may be necessary to avoid the interference. Micro-switch type S3, S4 and S5 Voltage Maximum current 25V maximum 5/6 Hz 5 8 Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28

erformance Data ypical with mineral oil at 36 cst (168.6 SUS) and a specific gravity of.87. Maximum flow rates erformance based on full power solenoid coils warm and operating at 9% rated voltage. See note at bottom of next page when using low power coils (DG4V-3 models only). DG4V-3S models (standard performance) Graph 1 C solenoid valves with dual frequency coils operating at 5 Hz Graph 2 C solenoid valves with Dual frequency coils operating at 6 Hz Single frequency (5 Hz) coils operating at 5 Hz ressure psi 5 4 3 2 1 bar 35 3 25 2 15 1 5 8 6 7 9 5 4 3 2 1 ressure psi 5 4 3 2 1 bar 35 3 25 2 15 1 5 8 7 6 3 4 5 2 1 1 2 3 4 l/min 1 2 3 4 l/min 2 4 6 8 1 USgpm Flow rate 2 4 6 8 1 USgpm Flow rate Graph 3 DC solenoid valves ressure psi 5 4 3 2 1 bar 35 3 25 2 15 1 5 3 8 7 1 2 3 4 l/min 2 4 5 2 4 6 8 1 USgpm Flow rate 6 1 Spool/spring Graph 1 Graph 2 Graph 3 code curve curve curve (L) 1 1 3 (L) & C, F 1 1 1 2(L) 5 5 3 2(L) & 2C, 2F 2 2 3 2N 1 1 1 6(L) & 6C, 6F 6 6 5 7(L) & 7C, 7F 6 6 2 8(L) & 8C 8 s 7 s 8 s 22(L) 9 8 7 22(L) & 22C 7 7 6 24(L) 6 6 5 33(L) & 33C 4 4 4 34(L) & 34C 6 6 5 52L, 52C, 6 6 5 56L & 56C 6 6 5 66(L) & 66C 3 3 5 521 & 561 6 6 5 s Consult Eaton regarding each application that will jointly have flow rates approaching this curve and a pressurized volume exceeding 2 cm 3 (122 cu.in.) Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28 9

erformance Data DG4V-3 models (high performance) Graph 4 C solenoid valves with: Single-frequency coils Dual-frequency coils operating at 5 Hz Graph 5 C solenoid valves with dualfrequency coils operating at 6 Hz ressure psi 5 bar 35 Graph 6 DC solenoid valves ressure 4 3 2 1 psi 5 4 3 2 1 3 25 2 15 1 5 bar 35 3 25 2 15 1 5 8 6 7 5 3 4 7 & 9 1 2 3 4 5 6 l/min 5 3 6 9 12 15 USgpm Flow rate 7 8 6 4 5 9 1 2 3 4 5 6 7 8 l/min 5 3 6 9 12 15 18 21 USgpm Flow rate 2 3 1 4 6 2 2,3 4 & 6 1 ressure psi 5 4 3 2 1 bar 35 3 25 2 15 1 5 7 5 3 6 1 2 3 4 5 6 l/min 3 6 9 12 15 USgpm Spool/ Graph Graph Graph spring 4 5 6 code curve curve curve (L) 2 2 3 (L) & C, F 1 1 2 2(L) 2 2 3 2(L) & 2C, 2F 1 1 1 2N 1 1 2 6(L) & 6C, 6F 6 5 6 7(L) & 7C, 7F 1 1 2 8(L) & 8C 5 s 4 s 5 s 22(L) 8 7 8 22(L) & 22C 7 6 7 24(L) 9 8 5 33(L) & 33C 4 3 4 34(L) & 34C 4 3 6 52L, 52C, 6 5 6 56L & 56C 6 5 6 66(L) & 66C 3 9 6 521 & 561 6 5 6 4 8 4 8 s Consult Eaton regarding each application that will jointly have flow rates approaching this curve and a pressurized volume exceeding 2 cm3 (122 cu.in.) 9 3 2 1 5 Flow limits applicable to the following usages: 1. ll valves except types 22 and 52 spools having simultaneous equal flow rates from to or and from or to and S3, S4, S5 (limit switch) models. 2. Valves with type 22 spools having flow from to or, the other being plugged. is drained at all times. 3. Valves with type 52 spools having one service port ( or as appropriate) connected to the full bore end of a 2:1 area ratio doubleacting cylinder and the other to the annulus end. 4. Consult Eaton, with application details, if either of the following usages are required: (a) Single flow path, i.e. to, to, to or to. (b) Substantially different simultaneous flow rates between to or and or to, e.g. when and are connected to a cylinder having a large differential area. Low ower Coils (DG4V-3 models only) When using low power coils (coil designations *L in model code) the maximum flow is reduced from values given on this page (graphs 4, 5 and 6) by up to: 7% for DC coils 5% for C coils depending on spool type. Consult your Eaton representative relative to specific applications for low power coils. 1 Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28

erformance Data ressure drops ressure drop psi bar 12 11 1 9 8 7 654 3 12 16 2 14 1 12 8 1 8 6 1 6 4 4 2 2 1 2 3 4 5 6 7 8 l/min 3 6 9 12 15 18 21 USgpm Flow rate DG4V-3S DG4V-3 ressure drop psi 2 16 12 8 4 bar 14 12 1 8 6 4 2 15 1 2 3 l/min 2 4 6 8 USgpm Flow rate DG4V-3S & DG4V-3 14 13 t Curve for spool type 6: not recommended for flows in excess of 6 l/min (15.8 USgpm). ressure drops in offset positions except where otherwise indicated Spool/spring Spool to to to to to to code positions or covered to (L) oth 5 5 2 2 (L) & C, F De-energized 4s Energized 4 4 2 2 2(L) oth 6 6 5 5 2(L) & 2C, 2F Energized 5 5 2 2 2N oth 6 6 3 3 6(L) & 6C, 6F De-energized 3s 3 Energized 6 6 1 1 7(L) & 7C, 7F De-energized 6s 6 7m Energized 4 4 3 3 8(L) & 8C ll 9 9 5 5 3 22(L), 22(L) & 22C ll 6 6 24(L) De-energized 6 6 2 2 33(L) & 33C De-energized 15s 15 Energized 5 5 2 2 34(L) & 34C De-energized 14s 14 Energized 5 5 2 2 52L & 52C Energized 6s 6 2 1m 56L oth 6s 6 11s 1 1m 56C De-energized 11s 1 1m Energized 6s 6 2 1m 66(L) & 66C De-energized 12 12 13 Energized 6 6 2 2 521 ll 6s 6 1m 561 De-energized 1s 11 1m Energized 6 6 1m s plugged plugged m plugged For other viscosities, pressure drops approximate to: Viscosity cst (SUS) 14 2 43 54 65 76 85 (17.5) (97.8) (2) (251) (32) (352) (399) % of p 81 88 14 111 116 12 124 change to another specific gravity will yield an approximately proportional change in pressure drop. he specific gravity of a fluid may be obtained from its producer. Fire resistant fluids usually have higher specific gravities than oil. Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28 11

Installation Dimensions Models for use with ISO 44 (DIN 4365) connectors Double solenoid models s DG4V-3(S)-*C-**-(V)M-U-**-6 DG4V-3(S)-*N-**-(V)M-U-**-6 1, (4.) 87, (3.42) D Single solenoid modelss DG4V-3(S)-*(-**) n DG4V-3(S)-*(-**) n DG4V-3(S)-8L(-**) DG3V-3(S)-*F n 74, (2.91) s shown DG4V-3(S)-*L(-**) n DG4V-3(S)-*L(-**) n DG4V-3(S)-8(-**) DG4V-3(S)-*FL(-**) n Coil types: U (shown), KU, S1, and S2 (see Model Code) 53, (2.1) Spolenoid and end cap interchanged 3rd angle projection lternative plug positions by loosening knurled nut, turning coil, and re-tightening. 25, (.98) C, coil 21,75 length (.86) (single solenoid model) (double solenoid model) 24, (.94) 48, (1.88) ort ort ort ort n Not applicable to type 8 spool. s See page 25 for solenoid information. Can vary dependent on source of plug. Dimensions in mm(in). Water-resistant manual override on solenoid DG4V-3(S)-****(L)-H-(V)M-**-**-6 pplication General use where finger operation is required (standard manual overrides cannot be operated without using small tool). Manual actucation must be applied within this diameter: approximately 2(.75). Spacer prevents actuation by larger device. 15 (.6) Overall length of valve with standard manual overrides Model type C or DC Dim. Dim. C Dim. D Dim. ll DC = 22 (8.66) 156 (6.14) 61 (2.5) 73 (2.87) DG4V-3 C ~ 2 (7.87) 146 (5.75) 51 (2.1) 63 (2.48) DG4V-3S C ~ 2 (7.87) 146 (5.75) 45 (1.7) 63 (2.48) Latching manual override on solenoid DG4V-3-****(L)-Y-(V)M-**-**-6 DG4V-3S-****(L)-Y-(V)M-**-**-6, DC coil models only pplication Stainless steel lever/latch mechanism and water-resistant seal make this feature ideal for vehicle-mounted and exposed applications requiring emergency selection of valve for a period of time in the event of electrical failure. Lever in latched position Lever in free position ush lever to operate valve; latch holds lever in 65 operated position (2.5) 4 (1.6) Overall length of valve with standard manual overrides Lift latch to release lever Spacer Note: H feature is not field convertible from other models; specify with order. Notes: 1. Opposite solenoid (on C and N double solenoid models) should not be energized while the valve is latched in selected position; C solenoid coils will burn out under this improper usage. 2. Y feature is field-convertible from H type manual override (omitting spacer), but is not field-convertible from other models. 12 Eaton Vickers Solenoid Operated Directional Valves roduct Catalog V-VLDI-MC11-E September 28