A case study in solving SCCR issues

Similar documents
Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

The easiest and fastest way to select and specify the right fuse

Specification made simple for selective coordination in a compact size

The easiest and fastest way to select and specify the right control circuit fuse

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Compact Circuit Protector (CCP) Application Note

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Electrical safety and reliability: Selective coordination. Protect with selective coordination

Selective Coordination Enforcement:

Electric vehicle auxiliary fuses 500 Vdc, A

Devices for Branch Circuits and Feeders

6.3 mm reverse quick connect

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

HVAC and Refrigeration Circuit Protection Solutions. Compact and safe HVAC/R circuit protection

UL Recognized power distribution blocks

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Compact Circuit Protector (CCP)

Effective December 2015 Supersedes September 2013

Selection Guide. Control Circuit and Load Protection

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

CUBEFuse. CUBEFuse catalog numbers (amps)

Applying Interrupting Rating: Circuit Breakers

Applying Interrupting Rating: Circuit Breakers

Application note Compact Circuit Protector (CCP2) Smaller, better... the Power of Space

Selective Coordination

Now - Up To 400A Mains!

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Industry s most comprehensive medium voltage circuit protection

Design Standards NEMA

Service Entrance Methods

Suggestion on How to Use

BH-1 modular fuse blocks, 700 V, 400 A

Harmonization of IEC and North American Safety Standards

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Low-Peak 600V Class RK1

Downtime Reduction, Workplace Safety & Code Compliance SERVICES TO INCREASE YOUR PRODUCTIVITY THROUGH PROTECTION

Compact Circuit Protector

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

Class J modular ferrule and knifeblade fuse blocks

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Ferrule fuses. High Speed Fuses

Short-Circuit Current Rating - SCCR Watlow Power Controllers

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

What's New with UL508A Codes & Standards Presented by Jeff Woolfolk Manufacturing in America March 14-15, 2018

PT Medium voltage fuses for potential and small power transformers

ECET Distribution System Protection. Overcurrent Protection

Panel SCCR 50kA RMS Symmetrical 480V Maximum

Bolted contact switches. Pringle switches

Selective Coordination Requirements

Electrical Safety and Overcurrent Protection

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Load Side PV Connections

Selecting Protective Devices

TRANSMISSION SYSTEMS

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

Quik-Spec Coordination Panelboard Specifications

A. Submit manufacturer's literature and technical data before starting work.

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

White Paper UL 1008 Withstand and Closing Rating Requirements

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Miniature circuit breaker Application guide

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Bussmann series NH catalogue. Leadership in circuit protection

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

up to 30A limited by conductor size Operating and storage temperature:

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Applying More Than One ArmorStart Motor Controller in a Single Branch Circuit on Industrial Machinery

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Compact Circuit Protector (CCP)

1489-M Circuit Breakers

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Overcurrent Protection According to the 2011 NEC

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Selective Coordination Compliance Methods for Evaluation and Mitigation

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

ACHIEVING MAXIMUM BENEFITS WITH A FUSE PROTECTED MOTOR CONTROL CENTER

Bussmann series Quik-Spec Coordination Panelboard

Products for enhancing electrical safety and reliability

Equipment Protection. Transformers 600V or Less

3.2. Current Limiting Fuses. Contents

Power System Solutions (PSS)

Supply-Side PV Connections

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Fused Coordination Panelboard

Compact Circuit Protector (CCP)

UL248 North American Low Voltage Fuses

Transcription:

White Paper 10601 Effective September 2016 A case study in solving SCCR issues By: Joe Graveline, Sr. application engineer, Eaton, Bussmann Division, and Erik Barnes, marketing manager, Eaton, Bussmann Division Viking Masek MS400 ABSTRACT Not only does the National Electrical Code (NEC ) require proper equipment and machinery short-circuit protection, it is also critical for safety of personnel and fire prevention. Proper planning in the design phase can avoid challenging jobsite corrections, and can often result in minimal-to-no impact on design, layout and material costs. Viking Masek, based in Oostburg, WI, manufactures custom automated packaging equipment. They recently had a project that needed a 65,000 amp Short- Circuit Current Rating (SCCR). Working with the circuit protection experts at Eaton s Bussmann division, an SCCR analysis of their design was performed. It identified several weak link components that limited the panel s SCCR to just 5,000 amps. These weak links were resolved when Viking Masek made several component substitutions that included using a UL 98 Listed Bussmann series Compact Circuit Protector disconnect switch with Class CC fuses that permitted applying a 200,000 amp SCCR to several Rockwell Automation Kinetix 5500 servo drives. This and other component changes improved the overall panel SCCR to 65,000 amps without impacting the panel layout or material costs. This case study will break down the SCCR analysis made for this project, highlight how the solutions were determined and demonstrate how proper planning can help achieve SCCR compliance with the NEC. BACKGROUND Machinery and equipment manufacturers are likely to be familiar with the term SCCR (Short- Circuit Current Rating). SCCR is the amount of short-circuit current an industrial control panel can safely withstand in the event of a short circuit. The National Electrical Code has driven awareness of this important rating since it became a requirement in 2005. Properly applying short-circuit protection is extremely important. Consider a fuse or circuit breaker. These are overcurrent protective devices and have what is known as an interrupting rating. This value defines the maximum amount of short-circuit current the device can safely interrupt. Applying a fuse or circuit breaker to a condition where the shortcircuit current exceeds its interrupting rating is a serious misapplication. The inability to safely interrupt a short-circuit event can result in disastrous consequences, including hazards such as fire, shock and arc blast. It s critical that the fuse or circuit breaker be properly applied to avoid these dangers. But what about devices that are not designed to interrupt a short-circuit event, such as motor starters, power distribution blocks, disconnects, and others? What happens to these devices during a short-circuit event? These devices will also experience the effects of the extremely rapid increase in current during a short-circuit event. However, they are not designed to operate or function under such high current conditions. Since these devices cannot interrupt or withstand short-circuit current on their own, it is critical that they be applied with the proper overcurrent protective device, such as a fuse or circuit breaker. These overcurrent protective devices act to open the circuit in a safe manner, but they do not operate instantaneously. Some level of the rapidly increasing short-circuit current will pass through before the overcurrent protective device can open the circuit and end the rapid current rise. The current that passes through before the overcurrent protective device can open the circuit is often referred to as the let-through current. The amount of let-through current depends on the overcurrent device used and the level of available shortcircuit current. Some overcurrent protective devices respond more quickly than others.

White Paper 10600 Effective September 2016 Solving SCCR issues This means that the ability of a motor starter, distribution block, or other device to safely endure a short-circuit event highly depends on being paired with the proper overcurrent protective device. The specific type of overcurrent protection necessary for a device to safely endure a short-circuit event can only be determined by testing that device in combination with a specified overcurrent protective device at defined voltage and short-circuit current levels. The result of a successful test is known as the component s short-circuit current rating. A device that is applied in a condition where the available short-circuit current exceeds its ability to endure the high currents of a shortcircuit event may also result in disastrous consequences similar to that of a misapplied fuse or breaker: arc blast, flying debris, shock and fire hazard. These devices must also be properly applied with the specified overcurrent protective device. To see a video of what can happen when panels are applied where their SCCR is inadequate, go to www.eaton.com/bussmannseries/sccr. The overcurrent protective devices interrupting rating and the components SCCR are then considered in determining the overall short-circuit current rating of the industrial control panel of the equipment. However, many equipment manufacturers struggle with this determination process. Conceptually, equipment SCCR evaluation seems simple, as it uses a weakest link approach that defines the equipment s overall SCCR value to be equal to the lowest rated component value. However, many engineers struggle when and where to apply the current-limiting rules that raise SCCR values, and a single mistake can result in an incorrect panel rating. Engineers also struggle with locating component SCCR information, which makes it difficult to find suitable substitutions to address low SCCR without requiring significant changes to the panel layout and/or overall material costs. The last major challenge to achieving SCCR compliance is the limited information about the available short-circuit current (also known as the available fault current) at the location in the electrical system where the equipment is being installed. The NEC requires that the equipment not be installed where the available short-circuit current exceeds its short-circuit current rating (NEC 409.22). These challenges not only increase the effort to design the compliant electrical controls for equipment and machinery, but they can also result in larger panels and increased material costs if a suitable solution cannot be found. Availability of the requisite component rating information, experience in solving SCCR, and access to knowledgeable resources are key to achieving a compliant SCCR solution in a timely manner while maintaining a competitive design. It is important to also note that 2017 NEC code changes will impact how engineers address SCCR. The new code will require the available short-circuit current be marked on the panel or documented at the time of installation. For more information about the specific code changes and their impact on equipment design and approach, see publication number 10508 at www.eaton.com/bussmannseries. All requierments as specified in the marking must be met to acheive higher component SCCR. THE PROBLEM Many OEMs are faced with the seemingly daunting challenge of designing and manufacturing equipment with SCCR sufficient to comply with NEC articles 110.10 and 409.22. The equipment SCCR must be equal to or greater than the available shortcircuit current at the location where that equipment is installed. Additionally, NEC article 110.9 requires that all overcurrent protective devices have a sufficient interrupting rating for the available short-circuit current including those inside the control panel s power circuit. 2

Solving SCCR issues White Paper 10600 Effective September 2015 A significant challenge for any OEM is to understand, interpret and correctly apply the guidelines in the UL 508A standard for industrial control panels. UL 508A Supplement SB contains an approved method for determining equipment SCCR along with an accepted and recognized evaluation process. However, this is often misunderstood or misinterpreted, and results in determining an incorrect equipment SCCR. In a recent survey, over 50 percent of OEMs acknowledged that they struggle with properly applying UL 508A. Another challenge facing OEMs is finding components with the right SCCR to fix the weak links limiting equipment SCCR. Finding the right component solution is the most significant factor regarding the impact on the design, layout and material cost adjustments. Most often, the OEM does not have the part in their hands to check its component SCCR marking and has to rely upon information from the manufacturer. Even today, with all that the internet offers, issues with finding SCCR information persist. Nearly eight out of ten OEMs surveyed expressed difficulty in finding this information. Manufacturer Viking Masek approached Eaton s Bussmann Division for assistance with determining the SCCR of their MS400 vertical form fill seal machine, and suggestions on how it could be raised to 65 ka. The Eaton Bussmann Application Engineering team provides free SCCR analysis, and was requested to help achieve SCCR compliance. The team performed an SCCR analysis using the Eaton Bussmann series OSCAR 2.1 SCCR analysis software, and determined the panel s design possessed just a 5 ka SCCR. 30A J Disconnect Breaker 10kVA Transformer Breakers Servo Drives Type F Combination Motor Controllers Breaker Thermostat Controller Power circuit configuration 30A J Disconnect 200kA Breaker 10kA 10kVA Transformer Breakers 10kA Thermostat Controller 5kA 65kA Servo Drives 5kA Breaker 10kA Type F Combina on Motor Controllers 65kA Initial analysis from the OSCAR 2.1 SCCR analysis software reveals weak links that must be addressed to achieve the desired 65 ka. 3

White Paper 10600 Effective September 2016 Solving SCCR issues OSCAR 2.1 applied the component SCCRs based on the circuit protective devices used, as well as the impact of the current limiting devices in the circuit. The analysis revealed the following, identifying which components must be addressed to achieve the desired 65 ka equipment SCCR value: 1) The miniature circuit breakers/supplementary protectors, rated at 10 ka must be replaced with overcurrent protective devices having an interrupting rating not less than 65 ka and with comparable dimensions. 2) The Kinetix 5500 servos had a 5 ka rating as applied. The presence of the current-limiting 30 amp Class J fuse in the feeder circuit is not able to improve the 5 ka rating. This required further investigation to resolve. 3) Although the power circuit components downstream of the power transformer had SCCRs less than 65 ka, the 10 kva power transformer raised their ratings to a level sufficient to achieve the desired 65 ka equipment SCCR. THE SOLUTION The Eaton Bussmann Application Engineering team researched design solutions to address the weak links limiting the panel s SCCR below 65 ka, starting with the miniature circuit breakers/ supplementary protectors. Considering the size, functionality and costs of these existing components, the Bussmann series Compact Circuit Protector (CCP) solution, with KTK-R Class CC fuses, provided the best solution when compared with a molded case circuit breaker or a fuse and fuse block solution. This component substitution not only raised the interrupting rating to 200 ka, it did so without any significant impact on costs or the panel layout. ORIGINAL OPTION 1 OPTION 2 OPTION 3 Breaker 10kA Class CC Holder 200kA Compact Circuit Protector with CC fuses 200kA Molded Case Circuit Breaker 65kA Inadequate IR Small Size Disconnect Sufficient IR Small Size No Disconnect Sufficient IR Small Size Disconnect Sufficient IR Larger Size Disconnect 4.37 3.00 (typical) 1.60 (typical) 3.70 5.12 (typical) 1.40 1.38 The Bussmann series Compact Circuit Protector with Class CC fuses can easily substitute for miniature breakers when a higher interrupting rating solution is needed. Next, a solution was sought for the 5 ka SCCR rating determined for the Rockwell Automation Kinetix servo drives. The design consisted of the Kinetix model 2198-H040-ERS, 2198-H025-ERS, 2198-H015-ERS and 2198-H008-ERS servo drives, which have a 200 ka SCCR value when applied with a specified overcurrent protective device. As applied in the existing design, the servos being fed by a single circuit breaker resulted in a 5 ka SCCR value. Upon reviewing instruction manual 2198-UM001G-EN-P, it was determined that a 200 ka SCCR value could be applied using specified fuses as the overcurrent protection to the servos grouped by model number. As per the servo instruction manual, the circuit was reconfigured, and protected by the specified fuse. All except the 40 A servo drives were fed by UL 98 Listed Compact Circuit Protector disconnect switches using several ampacities of Bussmann series KTK-R Class CC fuses. The 40 A servo drives were fed with Bussmann series Low-Peak LPJ-35SP Class J fuses. 3.00 (typical) Rockwell Automation Kinetix 5500 Servo Drives. 4

Solving SCCR issues White Paper 10600 Effective September 2015 Excerpt from Rockwell Automation Publication 2198-UM001G-EN-P (March 2016) detailing circuit protection requirements for the Kinetix 5500 servo drives. The design also contained a 480 V:240/120 V power transformer. According to the OSCAR 2.1 analysis, the components downstream of this transformer resulted in a suitable SCCR value. This determination was made by applying the UL 508A SB4.3.1 current limitation rules, which in simple terms state that the devices (overcurrent protective devices and others) will result in an SCCR value equal to the interrupting rating of the overcurrent protection on the primary of the transformer if all the devices downstream of the transformer have a respective interrupting rating or component SCCR not less than the fault current on the transformer s secondary as defined in table SB4.3 (for single phase). Based on the transformer s voltage and size, it was determined that the amount of available fault current on the transformer secondary was less than the downstream component SCCR, allowing the lineside overcurrent protective device interrupting rating (in this case, 200 ka) to be applied to these downstream components. Excerpt from UL 508A that defines the secondary available short-circuit current on the secondary of the 10kVA transformer to be 2,980 amps. 5

White Paper 10600 Effective September 2016 Solving SCCR issues CCP with CC fuse 200kA CCP with CC fuse 200kA 10kVA Transformer 10kVA Transformer (2.98kA short-circuit current) Breakers 10kA Thermostat Controller 5kA Breakers 10kA 200kA Thermostat Controller 10kA 200kA The use of the power transformer improves the rating of the downstream devices to 200 ka. With all the device issues addressed, the revised panel design was then analyzed in the OSCAR 2.1 software, and resulted in a new, higher SCCR of 65 ka. Based on this analysis, the following improvements were realized: 1) The 10 ka rated miniature circuit breakers/supplementary protectors that prevented a 65 ka panel rating were replaced with the Compact Circuit Protector using Class CC fuses, which improved the respective devices interrupting rating to 200 ka. 2) The SCCR of the servo drives improved to 200 ka after reconfiguring the circuit and applying the specified fuses as per the instruction manual. OSCAR 2.1 SCCR analysis software calculates the SCCR, applying the component SCCRs and the transformer/current limiting rules. 6

Solving SCCR issues White Paper 10600 Effective September 2015 Name VIKING MASEK MS400 Customer Examples - Requests and Examples Designation 65kA SCCR Report Voltage Ampere Final SCCR 480 / 277 V 800 A 65 ka ID Location Part Number Device Description Volts Amps Supply - Main Supply IR SCCR Adjusted SCCR 1 194R-H30-1753 Disconnect 480 / 277 15 0.0 ka 200 ka 200 ka Supply - Main Supply 1 LPJ-30SP CLASS - J 600 30 300 ka 0.0 ka 300 ka - Wire Jumper - off Main Supply Bus Bar 2 Wire Jumper Not considered in SCCR calculation 600 0 0.0 ka 200 ka 200 ka Branch - Branch Connected to Type E/F CMC 3 140M-C2E-B25 + 100-C09 1.6-2.5A Type F CMC 480 / 277 2.1 0.0 ka 65 ka 65 ka Branch - Branch Connected to Type E/F CMC 4 140M-C2E-B25 + 100-C09 1.6-2.5A Type F CMC 480 / 277 2.1 0.0 ka 65 ka 65 ka Branch - Branch Connected to 5 CCP-3-30CC Compact Circuit Protector (CCP), 3 - Pole, 30A Class CC 600 30 0.0 ka 200 ka 200 ka Branch - Branch Connected to 5 KTK-R-6 CLASS - CC 600 6 200 ka 0.0 ka 200 ka Sub - Sub- off 6 CCP-3-30CC Compact Circuit Protector (CCP), 3 - Pole, 30A Class CC 600 30 0.0 ka 200 ka 200 ka Sub - Sub- off Transformer 7-10 KVA or Less Transformer 240 0 0.0 ka 200 ka 200 ka Sub - Sub- off 6 KTK-R-5 CLASS - CC 600 5 200 ka 0.0 ka 200 ka 8 1492-SPM1C100 Supplementary Protector 240 15 10 ka 0.0 ka 200 ka Transformer adjusts SCCR from 10kA to 200kA Non-d Disconnect (UL508) 9 Not Specified Thermostat Switch 240 15 0.0 ka 5 ka 200 ka Transformer adjusts SCCR from 5kA to 200kA 10 1492-SPM1C100 Supplementary Protector 240 15 10 ka 0.0 ka 200 ka Transformer adjusts SCCR from 10kA to 200kA 11 1492-SPM1C100 Supplementary Protector 240 15 10 ka 0.0 ka 200 ka Transformer adjusts SCCR from 10kA to 200kA 12 1492-SPM1C060 Supplementary Protector 240 15 10 ka 0.0 ka 200 ka Transformer adjusts SCCR from 10kA to 200kA Branch - Branch Connected to 13 LPJ-35SP CLASS - J 600 35 300 ka 0.0 ka 300 ka Branch - Branch Connected to Holder 13 JM60060-3CR Class J fuse block 600V 60A 3P Box Lug 600 60 0.0 ka 200 ka 200 ka 14 2198-H040-ERSx Kinetix 5500 Drive 480 12.7 0.0 ka 5 ka 200 ka Combination adjusts to 200kA with LPJ-35SP 15 2198-H040-ERSx Kinetix 5500 Drive 480 12.7 0.0 ka 5 ka 200 ka Combination adjusts to 200kA with LPJ-35SP Branch - Branch Connected to 16 CCP-3-30CC Compact Circuit Protector (CCP), 3 - Pole, 30A Class CC 600 30 0.0 ka 200 ka 200 ka Branch - Branch Connected to 16 KTK-R-20 CLASS - CC 600 20 200 ka 0.0 ka 200 ka 17 2198-H015-ERSx Kinetix 5500 Drive 480 4.9 0.0 ka 5 ka 200 ka Combination adjusts to 200kA with KTK-R-20 18 2198-H015-ERSx Kinetix 5500 Drive 480 4.9 0.0 ka 5 ka 200 ka Combination adjusts to 200kA with KTK-R-20 Branch - Branch Connected to Compact Circuit Protector (CCP), 3-19 CCP-3-30CC Pole, 30A Class CC 600 30 0.0 ka 200 ka 200 ka Branch - Branch Connected to 19 KTK-R-20 CLASS - CC 600 20 200 ka 0.0 ka 200 ka 20 2198-H025-ERSx Kinetix 5500 Drive 480 7.8 0.0 ka 5 ka 200 ka Combination adjusts to 200kA with KTK-R-20 Branc - Branc Connecte to Fee er OSCAR 2.1 SCCR analysis software documents the SCCR analysis, indicating the resulting SCCR contribution for each component, including the specific overcurrent protective device that raises the component SCCR. 7

White Paper 10601 Effective September 2016 Solving SCCR issues OSCAR 2.1 SCCR Compliance Application contains over 60,000 parts and over 25,000 combinations of SCCRs, including nearly 10,000 Rockwell Automation products and nearly 3,000 associated combinations of SCCRs. Using its vast database, OSCAR found the component SCCRs of the servos and the interrupting ratings for the overcurrent protective devices. Based on the configuration, OSCAR then applied the transformer and current-limiting rules to adjust component ratings accordingly. The overall panel SCCR was then determined, and summarized in a report. BENEFITS Safety is key for all those involved with electrical equipment, whether it be the industrial engineer or consultant specifying the equipment requirement, the engineer designing the equipment, the electrician installing the equipment, the inspector approving the equipment, the operator using the equipment, the maintenance personnel maintaining the equipment, or the owner providing a safe working environment. Although SCCR compliance may be challenging at times, proper short-circuit protection is a critical element of machine/equipment safety. For Viking Masek, their panel s SCCR was improved from 5 ka to 65 ka with just a few component changes and minimal adjustment to the servo drives circuit position. Viking Masek can now send their MS400 equipment to the customer s jobsite and be confident it is suitably designed for fault current levels up to 65 ka. Using the OSCAR 2.1 report feature, the SCCR analysis validated the panel s enhanced SCCR, component by component, to aid in the equipment s installation and verification phase during the inspection and approval process. With the right resources and tools, SCCR compliance can be more easily achieved with minimal to no impact to design layout and costs. Supporting software tools such as the Bussmann series OSCAR 2.1 SCCR analysis software, and no-cost resources, such as the Application Engineering team at Eaton s Bussmann Division, make solving SCCR challenges easier. For more information or free assistance, contact the Application Engineering team at (855) BUSSMANN or email Tech@Eaton.com, or visit www.eaton.com/bussmannseries/sccr. AUTHORS BIOS Joe Graveline is senior applications engineer with the Bussmann Division of Eaton. Joe has over 25 years of experience in the field of electrical design, automation, and application sales support. He provides application support and product information on a wide variety of products made by Bussmann to industry professionals including sales channel partners, consulting engineers, OEMs, designers, specifiers and consumers. He also coordinates training for Bussmann series product distributors, OEMs and consulting engineers. Joe has previously held positions with ABB and Mitsubishi Electric and is a member of NFPA and IAEI. Erik Barnes is the Marketing Manager for the Bussmann Division of Eaton. He has worked for Eaton for 14 years in several roles with an electrical application focus. Erik has written numerous application papers and led initiatives to create innovative application tools such as SCCR Protection Suite, Selective Coordination Designer 1.0 and others. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States For Eaton s Bussmann series product information, call 1-855-287-7626 or visit: 2016 Eaton All Rights Reserved Printed in USA Publication No. 10601 September 2016 Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. Follow us on social media to get the latest product and support information.