Door Interlock Switches

Similar documents
Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

HS5E Series Miniature Solenoid Locking Switches

Door Interlock Switches

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Door Interlock Switches

HS6B Series Subminiature Interlock Switch

Door Interlock Switches

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1E Series Full Size Solenoid Locking Switches

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS6E - L 4 4 B 01 - G

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS5E Miniature Interlock Switches with Solenoid

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

HS1C Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches

HS1E-K Interlock Switches with Solenoid (3-circuit)

Section. Safety Products Selection Guide...B-2

HS5E Miniature Interlock Switches with Solenoid

Head Removal Detection Function for Safer Performance

HS5E Miniature Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

Door Interlock Switches

HS1L Interlock Switches with Solenoid

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

HS1E Interlock Swithes with Solenoid

Standard Interlock Safety Switches

HS1C-P Interlock Plug Unit with Door Lock

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

HS6E Subminiture Interlock Switches with Solenoid

SG-B1 SERIES / SG-A1 SERIES

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Solenoid Locking Safety Switches

Solenoid Locking Safety Switches

Standard Interlock Safety Switches

HS6B Subminiature Interlock Switches

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Interlock Switches Interlock Plugs

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Hinged Safety Door Switch

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

2 Specifications and Ratings. Applicable Standards. Operating Condition. Thermal Current Ith 10A Contact Ratings. Operating Speed

Door Handle Gate System

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Manual Reset Limit Switch

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Safety Limit Switch

D4GS-N CSM_D4GS-N_DS_E_7_2

Door Handle Gate System

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

Oiltight Switches & Pilot Devices

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

2NC (slow-action) Direct. Model. opening

Safety-door Switch. Ordering Information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Think Automation and beyond... IDEC Safety Interlock Switches

22mm XW E-Stops. UL File #E68961 CCC No Specifications

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

Miniature Switches & Pilot Devices

RU Series Universal Relays

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

HL (AZH) Limit Switches

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

Switches & Pilot Devices

Enabling Switches. Safety. Selection Guide

HL (AZH) LIMIT SWITCHES

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

HS7A-DMC Non-contact Interlock Switches

2NC (slow-action) Direct. Model. opening

Safety Control HR1S-AC. Safety Relay HR1S-AC

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

ø8 A8 Series Miniature Control Units

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

PRODUCT SPECIFICATION. Stack Lights. Series.

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

ø12 A2 Series Miniature Control Units

D4BL. Guard Lock Safety-door Switch

XA Series Emergency Stop Switches (w/removable Contact Block)

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

HL (AZH) Limit Switches

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4BS CSM_D4BS_DS_E_8_4

Safety switches with separate actuator

LK Position Switches TECHNICAL DATASHEET.

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Transcription:

HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x 40 x 146 mm) Four contacts Gold-plated contacts Spring lock type (unlocks when the solenoid is energized) and solenoid lock type (locks when solenoid is energized) are available Flexible installation - the head can rotate, allowing 8 different actuator entries Metal actuator entry slot ensures long life Actuator locking strength is 1000N minimum (GS-ET-19) Integral molded cable reduces wiring time LED pilot light indicates the solenoid status RoHS Directive Compliant Contacts are IP67 (IEC6029) NC contacts are direct opening (IEC/EN60947--1) Only proprietary actuators can be used, preventing unauthorized access (ISO149, EN1088) Double insulation structure - no grounding required Spring Lock Type Automatically locks the actuator without power to the solenoid After the machine stops, unlocking is accomplished by energizing the solenoid, providing a high level of safety Manual unlocking is possible in the event of power failure or maintenance Solenoid Lock Type The actuator is locked when energized The actuator is unlocked when deenergized EN1088 EN60947--1 IEC60947--1 GS-ET-1 BG standard in Germany Direct Opening Action Double Insulation Enabling Switches 2 Actuator Entry Slots Straight Actuator (mainly for sliding doors Right-angle Actuator Manual Unlocking Actuator Slot Barriers Integrated Cable Green LED Indicator AS-Interface Safety at Work Adjustable Actuator (mainly for hinged doors) L-shapted Actuator (mainly for hinged doors) Metallic Head 376 Spec Tech Industrial 3 Vest Ave. www.idec.com Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com

HSE Series Body Lock Mechanism Spring Lock Solenoid Lock Part Numbers Circuit Number Contact Arrangement Pilot Light Cable Length Part Number A B D A B D 1NC+1NC, 1NO, 1NO 1NC+1NC, 1NO, 1NC 1NC+1NC, 1NC, 1NC 1NC+1NC, 1NO, 1NO 1NC+1NC, 1NO, 1NC 1NC+1NC, 1NC, 1NC Contact configuration shows the contact status when actuator is inserted and solenoid off for for spring lock or solenoid on for solenoid lock. Actuator Keys Item Part Number Description HS9Z-A1 HS9Z-A2 HS9Z-A The actuator tensile strength is 00N minimum. Straight Right-angle Horizontal/vertical operation (for hinged doors) (see note below) 3 4 21 22 Without With Without With Without With Without With Without With Without With HSE-A4001 HSE-A4003 HSE-A400 HSE-A4401-G HSE-A4403-G HSE-A440-G HSE-B4001 HSE-B4003 HSE-B400 HSE-B4401-G HSE-B4403-G HSE-B440-G HSE-D4001 HSE-D4003 HSE-D400 HSE-D4401-G HSE-D4403-G HSE-D440-G HSE-A7Y001 HSE-A7Y003 HSE-A7Y00 HSE-A7Y401-G HSE-A7Y403-G HSE-A7Y40-G HSE-B7Y001 HSE-B7Y003 HSE-B7Y00 HSE-B7Y401-G HSE-B7Y403-G HSE-B7Y40-G HSE-D7Y001 HSE-D7Y003 HSE-D7Y00 HSE-D7Y401-G HSE-D7Y403-G HSE-D7Y40-G Accessories Appearance Description Part Number Weight Part Number HS9Z-SP1 HS9Z-T3 (+) ( ) A2 A1 1 2 1 2 3 4 21 22 1 2 1 2 HSB/HSE Plug Actuator (allows switch to be used as interlock plug unit) HSB/HSE Padlock Hasp (prevents unauthorized insertion of actuator) Description Mounting Plate Manual unlock key (long type) HS9Z-AP HS9Z-PH 3g 3g Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-262-IDEC Canada: 888-317-IDEC 377

HSE Series Circuit Diagrams Overview Interlock Switch Status Status 1 Status 2 Status 3 Status 4 Door closed Door opened Machine ready to Machine cannot be operate operated Solenoid de-energized Solenoid energized Door open Machine cannot be operated Solenoid energized Door open Machine cannot be operated Solenoid de-energized Unlocking Using Manual Unlock Key Door closed Machine cannot be operated Solenoid de-energized Door Status Locked Unlocked Manual Unlocking X Series E-Stops Circuit Diagram (Example: HSE-A4) (+) A2 3 ( ) A1 4 (+) A2 ( ) A1 3 4 Door Closed (locked) Closed (unlocked) Open Open Closed (unlocked) (+) A2 3 ( ) A1 4 (+) A2 3 ( ) A1 4 HSE-A4 Main Circuit - ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) AS-Interface Safety at Work Barriers Enabling Switches Spring Lock Type Safety Switch HSE-B4 HSE-D4 (+) ( ) A2 A1 3 4 21 22 1 2 1 2 (door open) - OFF (open) OFF (open) ON (closed) ON (closed) OFF (open) (unlocked) 3-4 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed) Main Circuit - ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) (door open) - OFF (open) OFF (open) ON (closed) ON (closed) OFF (open) (unlocked) 1-2 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Main Circuit - ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) (door open) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed) (unlocked) 1-2 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Solenoid Power A1-A2 (all types) OFF (de-energized) ON (energized) ON (energized) OFF (de-energized) OFF (de-energized) Door Closed (locked) Closed (unlocked) Open Open Closed (unlocked) Solenoid Lock Safety Switch HSE-A7Y HSE-B7Y HSE-D7Y (+) ( ) A2 A1 3 4 21 22 1 2 1 2 Main Circuit - ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) (door open) - OFF (open) OFF (open) ON (closed) ON (closed) OFF (open) (unlocked) 3-4 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed) Main Circuit - ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) (door open) - OFF (open) OFF (open) ON (closed) ON (closed) OFF (open) (locked) 1-2 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Main Circuit - ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) (door open) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed) (locked) 1-2 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Solenoid Power A1-A2 (all types) ON (energized) OFF (de-energized) OFF (de-energized) ON (energized) (note 4) 1. Main circuit: Connected to the control circuit of machine drive part, sending the interlock signals to the protective door. 2. Monitor circuit: Sends ON/OFF signals of main circuit and monitoring signals of open/closed status of protective door. 3. Do not attempt manual unlock when energized. 4. Do not energize the solenoid for a prolonged period of time when the door is open and when unlocking the door manually. Operating Characteristics (reference) Main Circuit (door open, NO) (door closed, NC) (Unlocked, NO) (Locked, NC) 0 (Key Insertion Position) 3.3 (Locked position).3 6.9 26.4 (stroke in mm) Contacts ON (closed) Contacts OFF (open) OFF (de-energized) to ON (energized) (see note 3) (see note 4) The characteristics shown in the chart above are of the HS9Z-A61, -A62, -A6, and -A66 actuators. For the HS9Z-A62S actuator, subtract 0.6 mm. The characteristics show the contact status when the actuator enters an entry slot of an interlock switch. 378 www.idec.com

HSE Series Specifications Conforming Standards ISO149, IEC60947--1, EN60947--1 (TÜV approval), EN1088, GS-ET-19 (BG approval), UL08 (UL recognized), CSA C22.2, No. 14 (c-ul recognized) Application Standards IEC604-1/EN604-1 Operating Temperature 2 to 0 C (no freezing) Relative Humidity 4 to 8% (no condensation) Storage Temperature 40 to +80 C (no freezing) Operating Environment Degree of pollution: 3 Impulse Withstand Voltage 2. kv (between LED, solenoid and grounding: 0. kv) Insulation Resistance (DC megger) Electric Shock Protection Class Degree of Protection Shock Resistance Vibration Resistance Actuator Operating Speed Positive Opening Travel Positive Opening Force Tensile Strength when Locked Operating Frequency Mechanical Life Electrical Life Conditional Short-circuit Current Cable Cable Diameter Weight (approx.) Specifications Between live and dead metal parts: 100 MΩ minimum Between live metal part and ground: 100 MΩ minimum Between live metal parts: 100 MΩ minimum Between Terminals of the same pole: 100 MΩ minimum Class II (IEC640) IP67 (IEC6029) Operating extremes: 100 m/s 2 (10 G) Damage limits: 1000 m/s 2 (100 G) Operating extremes: 10 to H, amplitude 0.3 mm minimum Damage limits: 30 Hz, amplitude 1. mm minimum 0.0 to 1.0 m/s Actuator HS9Z-A1: 1m minimum Actuator HS9Z-A2/A: mm minimum 80N minimum 1000 N minimum (GS-ET-19) 900 operations per hour 1,000,000 operations minimum (GS-ET-19) 100,000 operations minimum (operating frequency 900 operations per hour, rated load AC-, 20V, 1A) 0A (20V) (Note: Use 20V/10A fast acting type fuse for short circuit protection.) UL64, No. 21 AWG (8-core: 0. mm 2 or equivalent/core) ø7.6 mm 400 g (HSE-***01) Part Number Key HSE - A 4 4 01 - G Pilot Light Pilot Light Color G (Green) Cable Length 01: 1m 03: 0: Pilot Light Voltage 4: V DC 0: without pilot light Solenoid Unit Voltage/ Lock Mechanism 4: V DC/Spring Lock 7Y: V DC/Solenoid Lock Circuit Code Door Monitor Circuit Lock Monitor Circuit A: 1NC + 1NC 1NO + 1NO B: 1NC + 1NC 1NO + 1NC D: 1NC + 1NC 1NC + 1NC Locking Mechanism Spring Lock/Solenoid Lock Rated Voltage V DC Rated Voltage V DC Current 10 ma Current 266 ma Light Source LED Coil Resistance 90Ω (at C) Light Color Green Operating Voltage Rated voltage x 8% or less (at C) Return Voltage Rated voltage x 10% or more (at C) Maximum Continuous Applying Voltage Rated voltage x 0% Maximum Continuous Applying Time Continuous Insulation Class Class F Current Ratings Rated Insulation Voltage (Ui) (see note 2) 20V (between LED, solenoid and grounding: 30V) Current (Ith) 2.A Rated Voltage (Ue) 30V V 20V Rated Current (Ie) (see note 3) AC DC Resistive load (AC) 2A 1A Inductive Load (AC1) 1A 0.A Resistive load (DC) 2A 0.4A 0.2A Inductive Load (DC13) 1A 0.22A 0.1A 1. Minimum applicable load (reference value): 3V AC/DC, ma 2. UL rating: V 3. TUV, BG rating: AC-1, 0.A/20V, DC-13, 0.22A/V UL, c-ul rating: Pilot duty AC 0.A/V, Pilot duty DC 0.22A/V Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-262-IDEC Canada: 888-317-IDEC 379

HSE Series Dimensions (mm) and Mounting Hole Layouts Actuator Keys Overview HSE-**4*G (w/pilot light) Horizontal Mounting/Straight Actuator (HS9Z-A1) RP 26.4.2 6.2.2 32.9 13.4 R2.2 1.2 RP 26.4 6.2 32.9 13.4 R2.2 30 28 3 28 3 1 X Series E-Stops Slot Plug (Note) Actuator 61.6 ±1 36.2 106 14.7 (6.3) 1 Actuator 4-M4 Screws to 22 33 40 106 61.6 Mounting Hole Layout 36.2 6 ±1 106 14.7 1 (6.3) 33 40 Vertical Mounting/Right-angle Actuator (HS9Z-A2) 30 Slot Plug (Note) 29.6 Actuator Cover Actuator 61.6.6 ±1 RP 27.7. 36.2 32.9 RP 40.3 27.7 32.9 13.4 13.4 106 14.7 R2.2 1 3 1Actuator (6.3) Actuator Cover 4-M4 Screws to 22 33 40 29.6 106 61.6 36.2 7.6 ±1 R2.2 1 1 3 106 14.7 (6.3) 33 40 Enabling Switches Barriers Plug the unused actuator entry slot using the slot plug supplied with the actuators. Actuator Key Mounting Reference Position As shown in the figure on the right, the mounting reference position of the actuator when inserted in the safety switch is: HS9Z-A1: The actuator lightly touches the actuator stop placed on the safety switch. HS9Z-A2: The actuator cover lightly touches the actuator stop placed on the safety switch. After mounting the actuator, remove the actuator stop from the safety switch. Straight (HS9Z-A1) 6.2 32.4 (6).2 0.8 Mounting Hole Layout Safety Switch Key Stop HS9Z-A1 Actuator Right-angle type (HS9Z-A2) 33 2 7.2 7.2 Door Stop Door Stop Safety Switch Actuator Cover HS9Z-A2 Actuator 28 AS-Interface Safety at Work 1 26 30 28 1 4-R 2.2 6.4 4. 0.8 (Note) (Note) 10 2 2 Actuator Mounting Hole Layout (Straight, L-shaped) 2-M4 Screw 2-ø4.4 1.6 380 www.idec.com

HSE Series Vertically/Horizontally Movable Actuator (HS9Z-A) Horizontal Swing 49 1 Orienting Insert Vertical Swing Orienting Insert Actuator Type Mounting Plate Manual Unlocking Key (long) Angle Adjustment 3 (M3 Hexagon Socket Head Screw) 7 18. 29 (Note) (Note) 0.8 Manual Unlocking Key (plastic, supplied with the switch, non-replaceable) Manual Unlocking Actuator HS9Z-AP 2. () Handle: Aluminum Thickness: 2 3 1 9 Rivet: Stainless Steel 36 Washer: Steel 2. 10 R46 18 (.) 46 43 6 2 10 Area HSE Interlock (3) Switch (40) Dimensions and Mounting Hole Layouts, continued Angle Adjustment (M3 Hexagon Socket Head Screw) ø10 6. Spacer: Steel 22 40 6. (36.2) (106) 2 1 Part Number HS9Z-SP1 HS9Z-T3 (146) (6.3) Thickness: 2. Area Coating: Orange 26 38 (M4 Holes) 3.6 R2.1 HS9Z-T3 Manual Unlocking Key (metal, long-shaped) 1 130 Actuator Orientation The orientation of the actuator operation (horizontal/vertical) can be changed with the orientation part (white plastic part) installed on the back of the actuator. Do not loose the orientation part, otherwise the actuator will not operate properly. The actuator stop fi lm and actuator stop are used when adjusting the actuator position, and must be removed after adjustment. Actuator Mounting Hole Layout (horizontal/vertical swing) 2-M4 Screw 38 Accessory Dimensions (mm) 4 ø4 HS9Z-PH (3) 2. 28 16. 7. 7. Rivet: Stainless Steel 2-R4 ø4 Mounting Plate (HS9Z-SP1) 170 10. 2-.8 2-6.6 4-M4 40 21 22 6 10 4-R3.3.2 0.7 106 187 4-R6.4 4-C3 Material: Anonized A6063 Weight: approx. 180 g 8 27 33. 43 60 HSE Interlock Switch 2-ø8 27. (40) Material: SPCC Thickness: 1.6 9 (106) (36.2) (146) (6.3) Material: SPCC Thickness: 2.0 Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-262-IDEC Canada: 888-317-IDEC 381

HSE Series Operating Instructions of Hinged Door Actuator Angle Adjustment Overview When using the safety switch for a hinged door, refer to the minimum radius of doors as shown below. For doors with small minimum radius, use adjustable actuators (HS9Z-A). Using the angle adjustment screw, the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: 0 to Because deviation or dislocation of a hinged door may occur, make sure of correct operation of the actual application before installation. The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. X Series E-Stops HS9Z-A2 Actuator (When the center of the hinged door is on the extension line of the actuator mounting surface.) Minimum Radius 170 mm (36.2) 190 mm (3) Safety Switch Mounting Holes (When the center of the hinged door is on the extension line of the contact surface of actuator and safety switch. Minimum Radius 0 mm 260 mm (.) (40.3) (161) Safety Switch Mounting Holes (1) After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. After adjusting the actuator angle, apply loctite to the adjustment screw so that the screw will not loosen. When using the HS9Z-A horizontally-movable actuator When the center of the hinged door is on the extension line of the contact surface of actuator and safety switch: 0 mm When the center of the hinged door is on the extension line of the actuator mounting surface: 70 mm Horizontal Operation 0 mm Door Hinge (36.2) 70 mm Changing the Orientation of the Head Vertical Operation (.) Enabling Switches The head of the HSE can be mounted in four ways by removing the four screws from the corners of the HSE head and reinstalling the head in the desired orientation. Before wiring the HSE, replace the head. Before replacing the head, turn the manual unlock part to the UNLOCK position using the manual unlock key. When reinstalling the head, make sure that no foreign objects enter the safety switch. Tighten the screws, without leaving space between the head and body, otherwise the safety switch may malfunction. 0 mm Door Hinge (36.2) Safety Switch Mounting Hole (38) 70 mm Safety Switch Mounting Hole (8) Recommended tightening torque: 1.0 ±0.1 N m (.) Factory Setting Head can be rotated. Mounting Examples Barriers Slide Door Application Door HS9Z-A1 Keys AS-Interface Safety at Work Safety Precautions HSE Safety Switches Latch Door Stop Before manually unlocking the safety switch, make sure the machine has come to a complete stop. Manual unlocking during operation may unlock the switch before the machine stops, and the protection of the safety switch with solenoid is lost. While the solenoid is energized, do not unlock the actuator manually (solenoid lock type). 382 www.idec.com

HSE Series Instructions, continued For Manual Unlocking Spring lock type The HSE allows manual unlocking of the actuator to pre-check proper door operation before wiring or turning power on, as well as for an emergency or a power failure. Solenoid lock type If the actuator is not unlocked although the solenoid is de-energized, the actuator can be unlocked manually. LOCK UNLOCK Locked Unlocked Locked Position Locked Unlocked Manual Unlocked Position To change from the locked to the manual unlocked position as shown above, turn the actuator fully 90 using the proprietary actuator supplied with the switch. Using the safety switch with the actuator not fully turned (less than 90 ) may cause damage to the switch or errors (when manually unlocked, the switch will keep the main circuit disconnected and the door unlocked). Do not apply excessive force (0.4 N m or more) to the manual unlock part, otherwise the manual unlock part will be damaged. Do not leave the manual unlock key attached to the switch during operation. This is dangerous because the switch can be unlocked while the machine is in operation. Recommended Tightening Torque of Mounting Screws Safety Switch: 2.0 ± 0.2 N m (two M4 screws) Actuators HS9Z-A1: HS9Z-A2: HS9Z-A: 2.0 ± 0.2 N m (two M4 screws) 1.0 ± 0.2 N m (two M4 Phillips screws) 1.0 ± 1. N m (two M4 screws) The above recommended tightening torques of the mounting screws are the values confirmed with hex socket head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not become loose after mounting. Mounting bolts must be provided by the users. Manual Unlocking Key (supplied with the switch) To avoid unauthorized or unintended removal of safety switch and the actuator, it is recommended that the safety switch and the actuator are installed in an unremovable manner, for example using special screws or welding the screws. Cables Do not fasten or loosen the gland at the bottom of the safety switch. When bending the cable during wiring, make sure that the cable radius is kept at least 30mm. When wiring, make sure that water or oil does not enter the cable. Do not open the lid of the safety switch. Otherwise the switch may become damaged. Solenoid has polarity. Observe the correct polarity when wiring. Wire Identification Gland Wires can be identifi ed by the color and white line printed on the wire. No. Insulator Color No Insulator Color 1 white brown/white 2 black 6 orange 3 brown 7 blue/white 4 blue 8 orange/white Lid 30 mm min. Colored Insulator 8 1 2 7 3 6 4 Jacket Dummy Insulator (white) Terminal Number Identification When wiring, identify the terminal number of each contact with the color of insulator. The following table shows the identifi cation of terminal numbers. When wiring, cut unnecessary wires such as dummy insulator (white) and/or unused wires to avoid incorrect wiring. Type HSE-A HSE-B Blue HSE-D Orange Blue Orange Blue Orange Circuit Diagram (+) White A2 Orange/White Brown 3 4 Orange/White Brown 1 2 ( ) A1 Black Blue/White Brown/White Blue/White Brown/White Blue/White 21 22 Orange/White Brown 1 2 Brown/White Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-262-IDEC Canada: 888-317-IDEC 383

Precautions Safety Precautions In order to avoid electric shock or a fi re, turn the power off before installation, removal, wire connection, maintenance, or inspection of the switch. If relays are used in the circuit between the safety switch and the load, consider degrees of the danger and use safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the safety switch. Regardless of door types, do not use the safety switch as a door stop. Install a mechanical door stop at the end of the door to protect the safety switch against excessive force. Do not apply excessive shock to the switch when opening or closing the door. A shock to the door exceeding 1,000 m/sec 2 (approx. 100G) may cause the contacts of the switch to chatter, and a malfunction of the switch may occur. For connection of wires, unscrew the cover. Unnecessary loosening of other screws may cause a malfunction of the switch. For Rotating Head Directions The heads of the HSE/HSB can be rotated in 90 increments after removing the 4 screws on the corners of the head. Prevent entry of foreign objects into the switch during removal of the head. Tighten these screws with torque designated in the instruction sheet. Improper torque may cause errors. Factory Setting Head can be rotated. of Hinged Doors When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A). Wire Connection The HS2B has 3 conduit ports, which are closed as a part of the molded switch housing. Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. When breaking the conduit port, take care not to damage the contact block or other parts inside the switch. Operation Precautions - for all series HSE/HSB Precautions Do not place a PLC in the circuit between the safety switch and the load. The safety security can be endangered in the event of a malfunction of the PLC. Do not disassemble or modify the switch. It may cause a breakdown or an accident. Prevent foreign objects such as dust and liquids from entering the switch while connecting conduit or wiring. If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the switch may affect the mechanism of the switch and cause a breakdown. Do not store the switches in a dusty, humid, or organic-gas atmosphere. Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A2 Actuator When the door hinge is on the extension line of the interlock switch surface: 170 mm 190 mm When door hinge is on the extension line of the actuator mounting surface: 0 mm HS2B Precautions 260 mm Cracks or burrs on the conduit entry may deteriorate the housing protection against water. When changing to another conduit port, close the unused opening with an optional plug (Part No. HS9Z-P1). Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-262-IDEC Canada: 888-317-IDEC 397

Precautions HS1E Precautions Overview Wire Connection Make an opening for wire connection by breaking one of the conduit-port knockouts on the switch housing using a screwdriver. Before breaking the knockout, temporarily remove the connector-fi xing lock nut from the switch. 1. This unlocking method is intended for an escape from a machine when a person is locked in. For access to the unlocking entry, an access hole should be opened on the mounting panel. When opening the hole, apply proper protection against water or other foreign objects. 2. Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. When breaking the knockout, take care not to damage the contact block or other parts inside the switch. Cracks or burrs on the conduit entry may deteriorate the housing protection. X Series E-Stops When changing to the other conduit port, close the unused opening with an optional plug (accessory). Plug Type No. HS9Z-P1 Screwdriver Unlock Normal Position Unlock Manual Unlocking Position Manual Unlocking Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Insert a small screwdriver into the elliptical hole on the back of the switch, then push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). M. 26 89 Enabling Switches Regardless of door type, do not use the safety switch as a locking device. Install a locking device independently, for example, using a metal latch (also applicable to HS1E). The safety switch cover can be only removed with the special key wrench supplied with the switch or with the optional screwdriver (also applicable to HS1B and HS1E). Barriers AS-Interface Safety at Work HS1C Precautions Remove the screw located on the unlocking entry at the side of the switch using the key wrench included with the switch. Then insert a small screwdriver into the switch to push the lever inside of the switch toward the indicator until the actuator is unlocked (refer to the diagram on the right). Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. Screwdriver 398 www.idec.com

Precautions Operation Precautions Applicable Crimping Terminals Applicable Connectors (As shown below) (Refer to the Crimping Terminal 1 or 2 shown in the drawing below.) HS1C Terminals No. 1 to 6: Use solid or stranded wires only (crimping terminals not applicable). Terminals No. 7 and 8: Crimping Terminal 1 Ground Terminal: Crimping Terminal 2 HS1B Ground Terminal: Crimping Terminal 2 Other Terminals: Crimping Terminal 1 HS2B, HSB, and HS1E Crimping Terminal 1 3.6 min. 3. max. ø3.6 min. 6.9 max. Crimping Terminal 1 Use an insulation tube on the crimping terminal. Wire Approx. 4mm Insulation Tube 3. min. 3.8 max. ø4.in. 7.6 max. Crimping Terminal 2 Crimping Terminal Installation Examples (see the diagrams below) Mounting on Sliding Doors Door HS9Z-A1 Actuator Door Stop Mounting on Hinged Doors HS9Z-A2 Actuator Latch HS9Z-A1 Actuator Use connectors which maintain the IP67 protection. Applicable Connector Dimensions Flex Conduit: VF03 (Japan Flex) www.nipolex.co.jp Steel Connector (G1/2): ALC-103 (PF13.): RBC-103PG13. 9 mm max. G1/2 Recommended Screw Tightening Torque HS1C:.0±0. N-m (approx. 0± kgf-cm) (4 or 6 pcs of M hex socket head cap screws) HS1B:.0±0. N-m (approx. 0± kgf-cm) (2 or 4 pcs. of M hex socket head cap screws) HS2B:.0±0. N-m (approx. 0± kgf-cm) (2 pcs of M hex socket head cap screws) HSB: 4.0±0.4 N-m (approx. 40±4 kgf-cm) (2 pcs of M4 hex socket head cap screws) HS1E:.0±0. N-m (approx. 0± kgf-cm) (4 or 6 pcs of M hex socket head cap screws) Actuator (HS9Z-A1/A2).0±0. N-m (approx. 0± kgf cm) (2 pcs. of M6 hex socket head cap screws) Actuator (HS9Z-A1/A2) 2.0±0.2 N-m (approx. ±2 kgf cm) (2 pcs of M4 hex socket head cap screws) 1.0±0.2 N-m (approx. 10±2 kgf cm) (2 pcs of M4 Phillips screws) The screws are supplied by the user. Applicable Wire Size 30 mm max. HS1C: 0. to 0.7 mm 2 (Terminals No.1, 2, to 8) 1.0 to 1.2 mm 2 (Terminals No.3, 4, and grounding terminal) HSB: 0. to 1.2 mm 2 HS1E: 0. to 1.2 mm 2 Overview X Series E-Stops Enabling Switches Barriers AS-Interface Safety at Work USA: 800-262-IDEC Canada: 888-317-IDEC 399

Precautions Overview Actuator Angle Adjustment Using the screw (M3 hex socket head screw), the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: (0 ) to The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the entry slot of the safety switch. Recommended tightening torque: 0.8 N-m (approx. 8.0 kgf-cm) After adjusting the actuator angle, apply loctite or the like to the adjustment screw so as to prevent its loosening. X Series E-Stops of Hinged Door When using the interlock switch on hinged doors, refer to the minimum radius of doors shown below. When using on doors with small minimum radius, use the angle adjustable actuator (HS9Z-A). Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. When using the HS9Z-A2 Actuator When the door hinge is on the extension line of the interlock switch surface: Horizontal Swing 0 mm Vertical Swing 70 mm 190 mm Enabling Switches 170 mm When door hinge is on the extension line of the actuator mounting surface: 0 mm 260 mm When using the HS9Z-A Angle Adjustable Actuator When door hinge is on the extension line of the interlock switch surface: 0 mm When door hinge is on the extension line of the actuator mounting surface: 70 mm 0 mm 70 mm Actuator Angle Adjustment for the HS9Z-A Using the angle adjustment screw, the actuator angle can be adjusted (see fi gures on page 370. Adjustable angle: 0 to The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not loosen. Barriers AS-Interface Safety at Work Use a cable gland with a degree of protection IP67 G1/2, PG13., M 9 max. When Using Flexible Conduits (Example) Flexible conduit example: VF-03 (Nihon Flex) 30 max. Applicable Cable Glands When Using Multi-core Cables (Example) all dimensions in mm Conduit Port Size Plastic Cable Gland Metal Cable Gland G1/2 RLC-103 (Nihon Flex) PG13. RBC-103PG13. (Nihon Flex) M RLC-103EC (Nihon Flex) Conduit Port Size Plastic Cable Gland Metal Cable Gland G1/2 SCS-10* (Seiwa Electric) PG13. ST13. (K-MECS) M ST-MX1. (K-MECS) ALS-16** (Nihon Flex) ABS-**PG13. (Nihon Flex) ALS-**EC (Nihon Flex) Different cable glands are used depending on the cable sheath outside diameter. When purchasing a cable gland, confirm that the cable gland is applicable to the cable sheath outside diameter. When using a 1/2-14NPT cable gland, use the HSB interlock switch with M conduit port (Part No.: HSB-***BM) together with an adapter (Part No.: MA-M/NPT X1. 402-00, K-MECS) and a gasket (Part No.: GP M, K-MECS). Install a gasket between the interlock switch and the adapter. Apply sealing tape between the cable gland and the adapter to make sure of IP67 protection for the enclosure. 400 www.idec.com