Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Similar documents
Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

RP40- _FR/ Package (4) CTRL Logic (3)

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

Package (3) CTRL Logic (2)

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

Load (2) Single or Dual

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

RUZ- _/_ Protection (3) Isolation Option (4)

Packaging (1) Package

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. Non Isolated Power Module ROF-78E ROF-78E - SMD-R. DC/DC Converter

Features. Unregulated Converters. 2 Watt SIP7 Single and Dual Output RKZE. RKZE- _/_ Protection (4) Isolation Option (3) Single or Dual

UL Certified RP30-FW

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

(typ.) (Range) Load

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

RCD15W Series PART NUMBER STRUCTURE

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

DH50 SERIES. DATASHEET Rev. A

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

C B. Operating up to 5000m altitude 5 year product warranty Models

(typ.) (Range) ±18 330# 89 MPW MPW

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

S24SP series 40W Single Output DC/DC Converter

R-78AA-0.5 INNOLINE. Features. 0.5 AMP SMD Single Output. Derating-Graph (Ambient Temperature) DC/DC-Converter

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

S24SP15004 series 60W Single Output DC/DC Converter

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

RPR40. Features ICE Technology* POWERLINE+ 40 Watt Single & Dual Output. Railway-Converter with 3 year Warranty

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

RPP50-S. Features ICE Technology* POWERLINE+ 50 Watt 2:1 Single Output. DC/DC-Converter with 3 year Warranty

FEATURES. Input Voltage (VDC) 3.3

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

DCMCW60 SERIES FEATURES

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

APPLICATIONS: AVAILABLE OPTIONS

Maximum Input Current Vin=18V, 100% Load A Vin=24V ma No-Load Input Current

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A

DC/DC Converter URA(B)_LD-15WR2 & URA(B)_LD-20WR2 Series

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

DC/DC Converter URB1D_LMD-10WR3 Series

Switching Power Supplies

LSS-T/10-W12. Adjustable Output 10 Amp SIP-mount DC/DC Converter. PRODUCT OVERVIEW FEATURES

PG02S Series 2W DC/DC CONVERTER, SIP-Package

DC/DC Converter URF48_QB-75W(F/H)R3 Series

Open Frame Power Supplies

Input Voltage Range ±10% Output Voltage Accuracy Line Voltage Regulation RSS, RSS8, RSD, RSD10 1.2%/1% of Vin typ.

2W, Low Cost DIP, Dual Output DC/DC Converters

Series AM2F-Z 2 Watt DC-DC Converter

Description. Operational Features. Mechanical Features. Safety & EMC. Control Features. Protection Features

1000 WATT 24S12.84FXM DC/DC CONVERTER

OSR03-24 S 05 A Series Name Input Output Output Assembly Voltage Quantity Voltage Option PART NUMBER STRUCTURE

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output

GB60S 60W Single Output General Purpose Series

DC/DC Converter URF48_QB-200W(F/H)R3 Series

Very high efficiency up to 93% Adjustable output voltage

Features. Description. Table of Contents

DEWS SERIES 25W-30W WIDE INPUT RANGE

WATT MBH SERIES DC/DC CONVERTERS

LW SERIES 5W WIDE INPUT RANGE

Transcription:

Features Regulated Converters : Wide input voltage range.6kvdc Isolation UL, IEC/EN69 and EN certified Efficiency up to 88% OVP, OCP & OTP + C max. case temperature Description The RPA-AW series are high power density, wide input voltage range W DC/DC converters in an industry standard x case size. Despite their small size, the RPA-AW converters are fully specified devices with output currents up to 6Amps, up to 88% efficiency, no minimum load, 6VDC isolation, tight regulation and low ripple/noise figures. The outputs are also fully protected against over-temperature, short circuits, overcurrent and overvoltage and the single output version offers a ±% trim range. A heatsink option is available to extend the operating temperature range. The converters are UL and EN certified and will find many uses in railway and industrial applications where board space is at a premium. DC/DC Converter RPA-AW Watt x Single & Dual Output YEAR w a r r a n t y Selection Guide Part Number Input Output Output Input () Efficiency () Max. Capacitive Voltage Range Voltage Current Current typ. Load [VDC] [VDC] [ma] [ma] [%] [µf] RPA-.SAW (,) 9-6. 6 98 87 RPA-SAW (,) 9-6 97 88 RPA-SAW (,) 9-6 67 99 88 RPA-SAW (,) 9-6 9 88 RPA-DAW (,) 9-6 ± ±8 99 88 ± RPA-DAW (,) 9-6 ± ±67 9 88 ±68 Model Numbering Note: tested at nominal Vin, full load and at + C ambient UL69- certified IEC/EN69 certified EN certified E76 RPA- _AW/ Input Voltage Output Voltage Single or Dual Package () CTRL Logic () Ordering Examples RPA-.SAW = V Input,.V Output, Single, no CTRL pin RPA-DAW/P = V Input, V Output, Dual, Pos. CTRL function RPA-SAW-HC = V Input, V Output, Single, no CTRL pin, glued Heat-sink RPA-DAW/N-HC = V Input, V Output, Dual, Neg. CTRL function, glued Heat-sink Note: part without suffixes is without CTRL pin, trim pin fitted add suffix P for positive CTRL function (=ON, =OFF), trim pin fitted add suffix N for negative CTRL function (=ON, =OFF), trim pin fitted trim pin is only available for single outputs Note: add suffix -HC for glued Heat-sink (compatible with all other suffixes) REV.: 6/8 PD-

RPA-AW Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range 9VDC VDC 6VDC Input Surge Voltage ms max. VDC Quiescent Current ma ma Start-up time Internal Operating Frequency Power up CTRL ON/OFF Minimum Load % 8ms khz Ripple and Noise MHz BW, µf tantalum capacitor and µf ceramic capacitor mvp-p Under Voltage Lockout (UVLO) ON/OFF Control Input current of CTRL pin Positive Logic Negative Logic DC-DC ON DC-DC OFF DC-DC ON DC-DC OFF DC-DC ON DC-DC OFF 8VDC 7VDC 8.VDC 7.VDC Pi-Type 6ms 9VDC 8VDC Open or. < Vr < VDC Short or < Vr <.8VDC Short or < Vr <.8VDC Open or. < Vr < VDC Output Voltage Trimming Single Outputs -% +% RPA-.SAW 6mA. 9 8 7 6.... 6 7 8 9 6 RPA-SAW 9 8 7 6 6 7 8 9.......... PD- REV.: 6/8

Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted RPA-AW RPA-SAW 9 8 7 6 6 7 8 9.........7.9....67 RPA-SAW 9 8 7 6 6 7 8 9.........7.9.. RPA-DAW 9 8 7 6 6 7 8 9............6.7.8 REV.: 6/8 PD-

Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted RPA-AW RPA-DAW 9 8 7 6 6 7 8 9............6.67 OUTPUT TRIM Output Voltage Trimming RPA-AW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may slightly vary. TRIM UP TRIM DOWN R R 6 RPA-.SAW Trim up 6 7 8 9 % Vout =..6.9..6.9..6.9.6 Volts R U = 69 7 7..8 6. 7.8. 8.6 kohms Trim down 6 7 8 9 % Vout =.7...7...7...97 Volts R D = 9 7. 9. 6.7. 8.6 kohms RPA-SAW Trim up 6 7 8 9 % Vout =.......... Volts R U = 6 7 9. 68. 9..8. 8.6 kohms Trim down 6 7 8 9 % Vout =.9.9.8.8.7.7.6.6.. Volts R D = 6 87 69 78.7.9 9.. kohms RPA-SAW Trim up 6 7 8 9 % Vout =...6.8.6.7.8.96.8. Volts R U = 6 67 6 7 99..9 8. kohms Trim down 6 7 8 9 % Vout =.88.76.6...8.6..9.8 Volts R D = 7 9 9.9 6.9... kohms PD- REV.: 6/8

Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted RPA-AW RPA-SAW Trim up 6 7 8 9 % Vout =....6.7.9 6. 6. 6. 6. Volts R U = 9.9 6.9...9 kohms Trim down 6 7 8 9 % Vout =.8.7.....9.8.6. Volts R D = 8 9. 68... 8. 8.6 kohms REGULATION Parameter Condition Value Output Accuracy Single & Dual ±.% typ., ±.% max. Line Regulation Load Regulation PROTECTION Parameter Condition Value Short Circuit Protection (SCP) below mω continuous, auto recovery Over Voltage Protection (OVP) Over Current Protection (OCP) Over Temperature Protection (OTP) %-% Output Voltage, Hiccup, auto recovery %-6% Output Current, Hiccup C ± C Isolation Voltage () I/P to O/P tested for minute.6kvdc Isolation Resistance Isolation Capacitance Insulation Grade low line to high line Single Dual.Vout Vout Vout, Vout ±Vout, ±Vout Note: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: A slow blow type Note: For repeat Hi-Pot testing, reduce the time and/or the test voltage ±.% typ., ±.% max. ±.% typ., ±.% max. Cross Regulation asymmetrical %<>% load ±.% typ., ±.% max. Transient Response ±.% ±.% ±.% ±.% -7%, full load,.a/µs ±.% typ. % load step change µs typ. MΩ min. pf typ. basic ENVIRONMENTAL Parameter Condition Value Operating Temperature Range (6) - C to [refer to thermal calculation] Maximum Case Temperature + C Temperature Coefficient.%/ C Thermal Impedance please refer to table Operating Altitude m Operating Humidity 9% RH Shock G, ms, times along X,Y and Z axis Vibration -Hz,.G, mins along X,Y and Z axis MTBF according to Telcordia SR, + C 8 x hours REV.: 6/8 PD-

Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted Table : Thermal Impedance RPA-AW airflow [m/s] without Heatsink Rth without PCB [ C/W] Rth with PCB (6) [ C/W] Rth without PCB [ C/W] Thermal Calculation choose your model: RPA-SAW (with PCB (6) ) Load conditions in application (e.g. %) Airflow conditions in application (e.g..m/s) use Rth from Table (9.7 C/W) with Heatsink Rth with PCB (6) [ C/W]. 7.8. 6... 6...... 9.7.6 8.7.. 7. 9. 6.. 8..8 7... 6...7. Calculation: Iout = % R th = 9.7 C/W P DISS =.8W T CASEmax = C Note6: Test PCB:6xmmµm (Eurocard), double layer choose your model: RPA-SAW-HC (with PCB (6) ) Load conditions in application (e.g. %) Airflow conditions in application (e.g..m/s) use Rth from Table (8.7 C/W) Calculation: Iout = % R th = 8.7 C/W P DISS =.8W T CASEmax = C T OVER = R th x P Dis = 9.7 C/W x.8w = 7. C T OVER = R th x P Dis = 8.7 C/W x.8w =. C T AMBmax = T CASEmax - T OVER = C - 7. C = 77.8 C T AMBmax = T CASEmax - T OVER = C -. C = 8.6 C Output Power [%] 9 8 7 6 RPA-xxSAW Nature Convection (.m/s).m/s.m/s.m/s.m/s.m/s - 6 8 77.8 Ambient Temperature [ C] Output Power [%] RPA-xxSAW-HC 9 8 7 6 Nature Convection (.m/s).m/s.m/s.m/s.m/s.m/s - 6 8 8.6 Ambient Temperature [ C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety E76-A9 + A UL69-, nd Edition, CSA C. No. 69, nd Edition, IEC/EN Information Technology Equipment - General Requirments for Safety (CB Scheme) E76-A9-CB + A-CB IEC69-, nd Edition, + AM, EN69-, st Edition, 6 + AM, Railway Applications - Electrical Equipment used on rolling stock 7, 76 EN, st Edition, 7, Clause. and. RoHs + RoHS /, /6/EU + AM-/86 PD-6 REV.: 6/8

RPA-AW Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted EMC Compliance (designed to meet) Condition Standard / Criterion Information technology equipment - Radio disturbance characteristics Limits and methods of measurement Railway applications - Electromagnetic compatibility Part -: Rolling stock - Apparatus Specification for radio disturbance and immunity measuring apparatus and methods Part -: Methods of measurement of disturbances and immunity Conducted disturbance measurements Specification for radio disturbance and immunity measuring apparatus and methods Part -: Methods of measurement of disturbances and immunity Radiated disturbance measurements with external filter EN, Class A, EN--, EN6--, 9 EN6--, ESD Electrostatic discharge immunity test Air ±8kV, Contact ±6kV EN6--, 9; Criteria A Radiated, radio-frequency, electromagnetic field immunity test V/m, 8-MHz V/m,.-.GHz V/m,.-.7GHz V/m,.-6.GHz EN6--, 6; Criteria A Fast Transient and Burst Immunity ±kv IEC6--, ; Criteria A Surge Immunity ±kv EN6--, 6; Criteria A Immunity to conducted disturbances, induced by radio-frequency fields V EN6--6, 9; Criteria A EMI Filtering according to EN-- and EN Class A +VIN Fuse L D 7 C LOAD LOAD -VIN Note7: Diode is only needed for EN C 7µF/V electrolyt capacitor L µh Choke DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Type Value Material Package Dimensions (LxWxH) Package Weight case baseplate potting without Heat-sink with Heat-sink without -Heat-sink with Heat-sink Al Alloy, anodize black non-conductive FR Silicone (UL9-V). x. x.mm. x. x 6.8mm 7g typ. g typ. continued next page REV.: 6/8 PD-7

Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted Dimension Drawing (mm) RPA-AW...8. Ø.. Bottom View 6 recommended Layout: Top View.6 6...6.7 6 Heat-sink Dimension Drawing (mm). 6.8.. 6 x Ø. Pin Connections Pin # Single Dual +Vin +Vin -Vin -Vin. Top View Heat-sink CTRL () CTRL () -Vout -Vout Trim Com 6 +Vout +Vout Pin Pitch Tolerance ±.mm Pin dimension tolerance ±.mm XX.X ±.mm XX.XX ±.mm. PD-8 REV.: 6/8

RPA-AW Specifications measured @ta = C, resistive load, nominal Vin and rated Iout unless otherwise noted PACKAGING INFORMATION Parameter Type Value Packaging Dimensions (LxWxH) Packaging Quantity Storage Temperature Range Storage Humidity without Heat-sink with Heat-sink tube 8. x 7.6 x 9.mm 8. x 7.6 x.8mm pcs - C to + C % - 9% RH The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. REV.: 6/8 PD-9