QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

Similar documents
QF(19) - Series Miniature Circuit Breakers

QF(13) - Series Miniature Circuit Breakers

L Frame - Series Moulded Case Circuit Breakers

Rail Mount Energy Meters. Ecolec 300 Rail Mount Energy Meters. Features. Applications. Approvals

Accessories. CBI Mini Rail (SAMR096) Mini Rail Fuchs Rail-to-Rail Adaptor Plate (SAMR101) Mini Rail Fuchs Rail-to-Rail Adaptor Plate (SAMR100)

DD Frame - Series Circuit Breakers

Wiring Accessories. low voltage. Wiring Accessories

CBI Hydraulic Magnetic Circuit Breakers

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

max pole for t=15 ms

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

F-Series. Circuit Breaker

F-Series. Circuit Breaker

FR circuit breaker - hydraulic magnetic,

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal Overload Relays

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

AR circuit breaker - Hydraulic magnetic,

G-Series. Circuit Breaker.

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Thermal-Magnetic Circuit Breaker M1-...

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

PD-Series Ground Fault Circuit Protection

Miniature Circuit Breakers

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Btdin RCBO 6000A up to 63A (2P)

up to 63 A (1 module per pole)

TMC 91H is now TMC 60 C Series

Series KTU7 UL489 Molded Case Circuit Breakers

Jtec 10kA Miniature Circuit Breaker

RX 3 M.C.B A up to 63 A

MS General Information Extended Product Type: MS

G-Series DIN-RAIL CIRCUIT BREAKER

RX 3 M.C.B A up to 63 A

L-Series. Circuit Breaker

Miniature Circuit-Breakers (MCBs)

Series KTU7 UL489 Molded Case Circuit Breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Thermal Overcurrent Circuit Breaker 3120-F...

D509E. Manual Motor - Starters

Electronic overload relays EF205 and EF370

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Magnetic and Hydraulic-Magnetic Circuit Breaker

CHINT. NM7 Moulded Case Circuit Breaker

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Low Voltage A GE Power Controls Company. General catalogue

cor Long Run Experience

Technical Section: Miniature Circuit Breakers

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Thermal-Magnetic Circuit Breaker M1-..

Magnetic and Hydraulic-Magnetic Circuit Breaker

Data Sheet Manual Motor Starter Ex9S32 Series

Thermal Overcurrent Circuit Breaker 3120-F...

Electronic overload relay EF65, EF96 and EF146

Thermal-Magnetic Circuit Breaker 201/-WA

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Thermal overload relay TF65 and TF96

1489-M Circuit Breakers

Thermal overload relay TF140DU and TF140DU-V1000

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Thermal Overcurrent Circuit Breaker 3120-F...

Control Circuit Protection

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Bulletin 1489 Circuit Breakers. Selection Guide

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Selection Guide. Control Circuit and Load Protection

J-Series CIRCUIT BREAKER

Manual Motor Starters. Meta-MEC

Essential equipment for all your requirements

Catalog Issued 3-03 (PDF Rev )

Thermal Overcurrent Circuit Breaker 3120-F...

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Miniature Circuit-Breakers (MCBs)

Technical Information

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit.

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Series L9 UL-489 Miniature Circuit Breakers

DMX 3 -I 2500 switch disconnectors

ER circuit breaker - Hydraulic magnetic,

Thermal Overcurrent Circuit Breaker 3120-F...

NB1 Miniature Circuit Breaker

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Data Sheet Manual Motor Starter Ex9S32 Series

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Jtec 489 UL489 Branch Circuit Breaker

Transcription:

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Dual Mount 1 pole Dual Mount 2 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three pole, 1+N and 3+N (VDE) VC 8036 compliant (SANS 556-1) VDE, EAC and CCC approved, CE certified Ratings 5 to 63 A (subject to certification) Precision tripping characteristics Trip indication with mid-trip position Reset immediately after overload Dual mount product in black shells Suitable to use for electrical isolation Box terminals suitable for cables up to 50 mm 2 Applications AC branch circuit protection (IEC / EN 60947-2) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Residential equipment Industrial equipment Optional Accessories Handle lock Surface mounting clips Busbar Escutcheon blank Safety blank Approvals VC 8036 (IEC / EN 60947-2) A005438 S Page 1 of 6

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Technical Data Circuit Breaker Approvals VC 8036 (SANS 556-1) Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 5 A Maximum Current Rating 63 A Specific Ratings (Verify Certification) 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 63 A Interrupting Capacity 5 ka Circuit Breaker Approvals IEC / EN 60947-2, VDE, CE, EAC Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 5 A Maximum Current Rating 63 A Specific Ratings (Verify Certification) 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 63 A Interrupting Capacity 6 ka Circuit Breaker Approvals CCC Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 5 A Maximum Current Rating 63 A Specific Ratings (Verify Certification) 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 63 A Interrupting Capacity 6 ka QF(26)LR Operating Temperature Range -40 C to +85 C Mounting Options Dual mounting (DIN & Mini), surface mount Time Delay Curves 1, 2 Endurance 00 operations - electrical at rated current and voltage (IEC 60947-2) Dielectric Strength 1480 V (single pole) / 1830 V (multi pole), 50 Hz for one minute after testing Weight 200 g per pole (unpacked) Humidity 35 to 85% relative Altitude Certification tests done at altitude 2000 metres. Will operate at higher altitudes. Shock 50 G to MIL-STD-202G, test method 213B, test condition 1 Vibration 10 G to MIL-STD-202G test method 204D, test condition A Flammability I3 - Ignition does not persist at 850 C after glow wire is withdrawn with an oxygen index of 28 Toxicity F1 - Smoke index of 20 which determines the fume class Pollution Degree PD2 - Normally only non-conductive pollution occurs. Temporary conductivity caused by condensation is to be expected. Breaker QF Wire Size mm² (IEC) Torque (IEC) Comments 1 Pole to 4 Pole 1-50 mm² 4 Nm Pozidriv #2 Combi head Page 2 of 6

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Ordering Information Example Code: QF-----3(26)-DM-2-125A------ Group 1 2 3 4 5 6 7 8 9 10 11 Requirement QF Frame Switch / Neutral Not applicable Triple pole 26 mm module width Dual Mount Medium delay curve 2 Current Rating 125 A Future use Shunt Trip Future use Long Code QF - - 3 (26) DM 2 125A - - - Group 1: Frame Type Group 2: Switch/Neutral Group 3: Auxiliary Group 4: No of Poles Group 5: Module Width Group 6: Mounting Group 7: Time Delays Group 8: Current Ratings QF 26 mm wide miniature circuit breaker - Not applicable Overload poles do not have any further coding S Switch Green handle N Neutral Green handle - Not applicable 1 Single pole 2 Double pole 2 pole or 1+N 3 Triple pole 4 Four pole 4 pole 3+N or only 3+N (26) 26 mm module width 26 mm per pole DM Dual mount 57 Dual mm mount escutcheon, black body Dual mount supplied Dual Mount in black supplied body in only black - 57 only mm escutcheon Code Description Instantaneous Trip Point (x In) Comments 1 Long time delay, high instantaneous trip 10 20 Orange handle 2 Medium time delay 5 10 White handle 3 Code Short / Description time delay 3 5 Comments White handle 9 70, 80, Long 90,, time 125 delay A 7 12 White handle Group 9: Code For future use (-) Group 10: Shunt Trip - Not applicable Use this code if no shunt trip is used Group 11 Code For future use (-) For options not listed, please contact CBI Page 3 of 6

Time Delay Curves QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) 000 OPERATING CHARACTERISTICS 00 CURVE 1 0 Tripping Time (Seconds) 10 1 0.1 0.01 Maximum 0.001 105 130 150 200 300 400 500 0 2000 2500 3000 4000 5000 Minimum % Rated Current Page 4 of 6

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Time Delay Curves 000 OPERATING CHARACTERISTICS 00 CURVE 2 0 Tripping Time (Seconds) 10 1 0.1 0.01 Maximum 0.001 105 130 150 200 300 400 500 0 2000 2500 3000 4000 5000 Minimum % Rated Current * The published time delay curves are generated at 30 o C ambient temperature with the Circuit Breaker mounted in the up-right position. The must hold, must trip and instantaneous trip current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Page 5 of 6

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A) Internal Impedance vs Current Rating 10,000 Q-Range impedance values 1,000 Impedance (mω) 10 Maximum 1 Minimum Outline Dimensions: Dual Mount 0.1 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Amp rating Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss. AUSTRALIA CBI-electric: Australia 27 Wedgewood Rd, Hallam Victoria 3803 Australia Tel: +61 3 8752 9300 Fax: +61 3 9796 5407 Email: sales@cbi-electric.com.au Website: www.cbi-electric.com.au Page 6 of 6 SOUTH AFRICA CBI-electric: Tripswitch Drive Elandsfontein Gauteng South Africa Tel: +27 11 928 2000 Fax: + 27 11 392 2354 Email: cbi@cbi-electric.com internationalsales@cbi-electric.com Website: www.cbi-lowvoltage.co.za USA CBI-electric: North America 35 E. Uwchlan Ave Suite 328 Exton PA 19341 USA Tel: +1 610 524 9949 Fax: +1 610 524 9945 E-mail: info@cbibreakers.com Website: www.cbibreakers.com A member of the Group