Safety rope switches with reset for emergency stop

Similar documents
Safety rope switch with reset for emergency stop

Safety rope switch without reset for simple stop

Safety switches for hinges

FL series position switches

Safety switches with separate actuator

Safety switches with separate actuator

Safety switches with solenoid and separate actuator

Safety switches for hinged doors

Safety switches with solenoid and separate actuator

Position switches FD series

Switches with manual reset

Rope safety switches with reset for emergency stop

Safety switches for hinged doors

Position switches FC series

Position switches FR series

Microswitches MK series

Position switches FR series

Single foot switches - PX and PA series

LK Position Switches TECHNICAL DATASHEET.

LR-LX-LK-LW Safety Switches with separate actuator

SFS-UFS Single Foot Switches

Microswitches M series

Prewired position switches FF series

Single foot switches PX and PA series

Prewired position switches FF series

Microswitches MK series

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive

Safety switches with solenoid and separate actuator

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Single foot switches PX and PA series

Microswitches MK Series

Safety Limit Switches

Key selector switches

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

AF40... AF96 3-pole contactors Technical data

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

EA series housings. Selection diagram. 125 General Catalogue HMI ACTUATORS ACCESSORIES COVERS. emergency button Ø 40 push-pull, windowed

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Miniaturized limit switches

Manual Reset Limit Switch

Safety Limit Switch

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Limit Switches - Limit Type (PS21L) Metal Body IP66

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Limit Switches - Limit Type Plastic Body IP65

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Automation - Lift - Handling System - Atex

Safety switches with solenoid and separate actuator

Standard Interlock Safety Switches

Hinged Safety Door Switch

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Limit Switches - Limit Type Plastic Body IP65

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Limit Switches with Positive Opening Mechanism

Safety switches with solenoid and separate actuator

XACA871 pendant control station XAC-A - 8 pushbuttons

Limit Switches - Limit Type (PS31L) Plastic Body IP65

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Safety switches with solenoid and separate actuator

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

FOOT SWITCHES

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

XACA871 pendant control station XAC-A - 8 pushbuttons

Cylindrical fuse-link

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Safety detection solutions

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

General Catalogue Detection

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Safety-door Switch. Ordering Information

Limit switches 3. Page 92. Page 92

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

HS5D Miniature Interlock Switches

Industrial Contactors CTX 3 3P 185A - 800A

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Cable (Rope) Pull Switches Lifeline 4

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

BETA Switching Switches and Light Indicators

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

XACA871 pendant control station XAC-A - 8 pushbuttons

Compact plastic limit switches with positive opening mechanism

Electronic overload relay EF65, EF96 and EF146

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

Position Switches Series 8070/2

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Rotary limit switches FCR FGR series

AZM 161SK 12/12RKED/TU 024

SIRIUS 3RU2 Thermal Overload Relays

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Transcription:

Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available signal lamps, see page 312 Red Yellow Threaded conduit entry (standard) With cable gland With M12 plastic connector With M12 metal connector product option accessory sold separately 9 General Catalogue Safety 1-18

Code structure Housing FD metal, one conduit entry FL metal, three conduit entries FP technopolymer, one conduit entry 18, 9, 1NO+, 21, 22, 33, 34, Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options options FD 188-EGM2K50T6 Ambient temperature T6-25 C +80 C (standard) - C +80 C Pre-installed cable glands or connectors no cable gland or connector (standard) K23 cable gland for cables Ø 6 12 mm K50 M12 metal connector, 5-pole For the complete list of possible combinations please contact our technical department. Actuating head 8 longitudinal head 83 left transversal head (FD-FL housing only) right transversal head (FD-FL housing only) standard E initial N...final N (only head 8) E9 initial 13 N...final 5 N (only head 83 ) Threaded conduit entry M2 Contact type Mx1.5 (standard) PG 13.5 silver contacts (standard) G silver contacts with 1 µm gold coating Silver contacts, 2.5 µm gold coating G1 (not for contact blocks, 21, 22, 33, 34) article options options FC 338-EGM2K50T6 Housing FC metal, one conduit entry Ambient temperature -25 C +80 C (standard) T6 - C +80 C 33, 34, Pre-installed cable glands or connectors no cable gland (standard) K23 cable gland for cables Ø 6 12 mm K50 M12 metal connector, 5-pole Actuating head 8 longitudinal head 83 left transversal head right transversal head Threaded conduit entry M2 Mx1.5 (standard) PG 11 standard E initial N...final N (only head 8) E9 initial 13 N...final 5 N (only head 83 ) Contact type silver contacts (standard) G silver contacts with 1 µm gold coating General Catalogue Safety 1-18 10

Safety rope switches with reset for emergency stop Technical data Housing FP series housing made of glass fibre reinforced technopolymer, self-extinguishing, shock-proof and with double insulation: FD, FL and FC series: metal housing, baked powder coating. FD, FP, FC series: one threaded conduit entry: Mx1.5 (standard) FL series: three threaded conduit entries: Mx1.5 (standard) Protection degree: IP6 acc. to EN 529 with cable gland of equal or higher protection degree Main features Metal or plastic housing, from one to three conduit entries Protection degree IP6 In compliance with EN ISO 13850 contact blocks available Versions with vertical or horizontal actuation Versions with assembled M12 connector Versions with gold-plated silver contacts General data For safety applications up to: SIL 3 acc. to EN 661 PL e acc. to EN ISO 139 1 Safety parameters: B 10D : 2,000,000 for NC contacts Service life: years Ambient temperature: -25 C +80 C Max. actuation frequency: 1 cycle / 6 s Mechanical endurance: 1 million operating cycles Max. actuation speed: 0.5 m/s Min. actuation speed: 1 mm/s Tightening torques for installation: see page 313 324 Max. cable cross section (flexible copper strands) s, 21, 22, 33, 34: min. 1 x 0.34 mm 2 (1 x AWG 22) max. 2 x 1.5 mm 2 (2 x AWG ) s 18, 9: min. 1 x 0.5 mm 2 (1 x AWG ) max. 2 x 2.5 mm 2 (2 x AWG 14) Quality marks: IMQ approval: EG5 UL approval: E1318 CCC approval: 0010500 (FD-FL-FC series) 0010514 (FP series) EAC approval: RU C-IT.AД35.В.00454 In compliance with standards: IEC 94 5-1, EN 94 5-1, EN 94 1, IEC 4 1, EN 4 1, EN ISO 14119, EN ISO 12100, IEC 529, EN 529, EN ISO 13850, EN 418, UL 508, CSA 22.2 No.14. Approvals: IEC 94 5-1, UL 508, CSA 22.2 No.14, GB148.5 01. Compliance with the requirements of: Machinery Directive 06/42/EC and EMC Directive 04/122/EC. Positive contact opening in conformity with standards: IEC 94 5-1, EN 94 5-1. If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 313 to page 324. Electrical data without connector Thermal current (I th 10 A Rated insulation voltage (U i 500 Vac 0 Vdc 0 Vac 500 Vdc (contact blocks, 21, 22, 33, 34) Rated impulse withstand voltage (U imp 6 kv 4 kv (contact blocks, 21, 22, 33, 34) Conditional short circuit current: 1000 A acc. to EN 94 5 1 Protection against short circuits: type am fuse 10 A 500 V Pollution degree: 3 Utilization category Alternating current: AC (50 Hz) (V) 250 0 500 (A) 6 4 1 Direct current: DC13 (V) 24 125 250 (A) 6 1.1 0.4 with M12 connector 4 and 5-pole Thermal current (I th 4 A Rated insulation voltage (U i 250 Vac 0 Vdc Protection against short circuits: type gg fuse 4 A 500 V Pollution degree: 3 Alternating current: AC (50 Hz) (V) 24 1 250 (A) 4 4 4 Direct current: DC13 (V) 24 125 250 (A) 4 1.1 0.4 with M12 connector 8-pole Thermal current (I th 2 A Rated insulation voltage (U i Vac 36 Vdc Protection against short circuits: type gg fuse 2 A 500 V Pollution degree: 3 Alternating current: AC (50 Hz) (V) 24 (A) 2 Direct current: DC13 (V) 24 (A) 2 11 General Catalogue Safety 1-18

Description These rope-operated safety switches are installed on machines or conveyor belts and allow the machine to be brought to an emergency stop from any point and with any pull on the rope. This means significant cost savings for medium and large machines, since multiple emergency-stop buttons can be replaced with a single switch. They are equipped with a self-control function that constantly checks the correct function and signals a possible loosening or breaking of the rope through the opening of the contacts. These safety switches keep the contacts open after activation until the reset is performed, even if the rope is released. Head with variable orientation For all switches, the head can be adjusted in 90 steps after removing the four fastening screws. Extended temperature range These devices are also available in a special version suitable for an ambient operating temperature range from -ºC up to +80 C. They can therefore be used for applications in cold stores, sterilisers and other equipment with low temperature environments. The special materials used to produce these versions retain their characteristics even under these conditions, thereby expanding the installation possibilities. Indicator for rope adjustment Area of correct rope tightening Tension indicator All switches are provided with a green ring that shows the area of the correct tightening of the rope. The installer has only to tighten the rope until the black indicator will be in the middle of the green area. With this setting, the switch can be reset by pulling the blue knob to close the electrical safety contacts. If the tension (or loosening) on the rope is so high that the black indicator exits the green area, the electrical safety contacts will open and the reset device will trigger. Laser engraving Protection degree IP6 These devices are designed to be used in the toughest environmental conditions and they pass the IP6 immersion test acc. to EN 529. They can therefore be used in all environments where maximum protection degree of the housing is required. Reduced actuating force Indicator for the state of the reset Armed reset All devices are marked using a dedicated indelible laser system. These engravings are therefore suitable for extreme environments too. Thanks to this system that does not use labels, the loss of plate data is prevented and a greater resistance of the marking is achieved over time. These switches can be supplied with reduced hardness internal springs on request. The force required to actuate the switch can thereby be reduced without changing the actuating path of the electrical contacts. This is particularly advantageous for smaller spans, but must, however, always make use of rope pulleys. Released reset If the tension indicator is in the green area, the electrical safety contacts can be closed by pulling the blue knob. The reset status can be identified quickly by the green ring under the blue knob. Features approved by IMQ Rated insulation voltage (Ui 500 Vac 0 Vac (for contact blocks, 21, 22, 33, 34) Conventional free air thermal current (Ith 10 A Protection against short circuits: type am fuse 10 A 500 V Rated impulse withstand voltage (Uimp 6 kv 4 kv (for contact blocks, 21, 22, 33, 34) Protection degree of the housing: IP6 MV terminals (screw terminals) Pollution degree: 3 Utilization category: AC Operating voltage (Ue 0 Vac (50 Hz) Operating current (Ie 3 A Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X Positive opening contacts on contact blocks 18, 9,, 21, 22, 33, 34 In compliance with standards: EN 94 1, EN 94 5 1+ A1:09, fundamental requirements of the Low Voltage Directive 14/35/EU. Please contact our technical department for the list of approved products. General Catalogue Safety 1-18 Features approved by UL Utilization categories Q0 (69 VA, 125 250 Vdc) A0 ( VA, 1 0 Vac) Housing features type 1, 4X indoor use only, 12, 13 For all contact blocks use or 5 C copper (Cu) conductor, rigid or flexible, wire size 12, 14 AWG. Tightening torque for terminal screws of.1 lb in (0.8 Nm). In compliance with standard: UL 508, CSA 22.2 No.14 Please contact our technical department for the list of approved products. 12

Safety rope switches with reset for emergency stop Dimensional drawings All values in the drawings are in mm Contact type: L =.8-34.3.8-34.3 65 28 28. -.2 65 28 28. -.2 5.4 18 L 9 L L 21 L 22 L 33 L 34 L.8-34.3.8-34.3 65 28 28. -.2 6.5 6.5 6.5 18 18 18 5 5 5.2 5.9 5.4x.4.2.4 38.6 6.2 x.3.4 36.5 6.2 x.3.4 36.5 6.2 x.3.4 36.5 FP 188-M2 FP 98-M2 FP 8-M2 FP 218-M2 FP 228-M2 FP 338-M2 FP 348-M2 1NO+ FD 188-M2 FD 98-M2 FD 8-M2 FD 218-M2 FD 228-M2 FD 338-M2 FD 348-M2 1NO+ FD 1883-M2 FD 983-M2 FD 83-M2 FD 2183-M2 FD 2283-M2 FD 3383-M2 FD 3483-M2 1NO+ FD 18-M2 FD 9-M2 FD -M2 FD 21-M2 FD 22-M2 FD 33-M2 FD 34-M2 1NO+ Travel diagrams Initial 63 N final 83 N (90 N ) page 14 - group 1 Initial 63 N final 83 N (90 N ) page 14 - group 1 Initial 14 N final 235 N (250 N ) page 14 - group 2 Initial 14 N final 235 N (250 N ) page 14 - group 2 56 31.5 56 31.5 56 31.5 18 L 9 L L 21 L 22 L 33 L 34 L FL 188-M2 FL 98-M2 FL 8-M2 FL 218-M2 FL 228-M2 FL 338-M2 FL 348-M2 1NO+ FL 1883-M2 FL 983-M2 FL 83-M2 FL 2183-M2 FL 2283-M2 FL 3383-M2 FL 3483-M2 1NO+ FL 18-M2 FL 9-M2 FL -M2 FL 21-M2 FL 22-M2 FL 33-M2 FL 34-M2 1NO+ Travel diagrams Initial 63 N final 83 N (90 N ) page 14 - group 1 Initial 14 N final 235 N (250 N ) page 14 - group 2 Initial 14 N final 235 N (250 N ) page 14 - group 2 Items with code on green background are stock items Accessories See page 299 The 2D and 3D files are available at www.pizzato.com 13 General Catalogue Safety 1-18

Contact type: L = 65 28 28. -.2.8-34.3.8-34.3 45.5 45.5 45.5 33 L 34 L Travel diagrams 33.4 FC 338-M2 FC 348-M2 Initial 63 N final 83 N (90 N ) page 14 - group 1 33.4 FC 3383-M2 FC 3483-M2 Initial 14 N final 235 N (250 N ) page 14 - group 2 33.4 FC 33-M2 FC 34-M2 Initial 14 N final 235 N (250 N ) page 14 - group 2 How to read travel diagrams All values in the diagrams are in mm NC opening NO closing Reset actuated 0 4 8.5 Ideal rope tension (middle of green area) Maximum travel 23-24 diagram Closed contact 8 11-12 Open contact Cut of the rope Traction of the rope NC opening NO closing Reset actuated Positive opening travel Travel diagrams table 18 9 1NO+ 21 22 Group 1 Group 2 0 4 8.5 0 8 14 8 0 4 8.5 0 8 14 8 0 4 8 8.5 0 8 14 0 4 8 8.5 0 8 14 0 4 88.5 14 0 8 R1.5 S R6.5 R4.5 S R12 IMPORTANT: In safety applications, actuate the switch at least up to the positive opening travel shown in the travel diagrams with symbol. Actuate the switch at least with the positive opening force, reported in brackets below each article, next to the actuating force value. 33 1NC+1NO 34 8 0 4 8.5 0 8 14 0 4 8.5 0 8 14 8 Accessories See page 299 The 2D and 3D files are available at www.pizzato.com General Catalogue Safety 1-18 14

Safety rope switches with reset for emergency stop Application examples and max. rope length for switches with longitudinal head A FD 188-M2 FD 188-M2 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 24 m MAX B FD 188-M2 VF AF-ME8 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 2 3 m 18 m MAX E VF F05 C FD 188-M2 VF AF-CA10 2 3 m 2 3 m 2 3 m 12 m MAX D VF F05 FD 188-M2 VF AF-TR8 FD 188-M2 6 m MAX 3 m max 3 m max Application examples and max. rope length for switches with transversal head F G H FD 18-M2 FD 18-M2 FD 18-M2 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 0 m MAX 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 3 5 m 35 m MAX 50 m MAX 3 5 m 3 5 m 3 5 m VF AF-ME80 VF AF-CA10 FD 1883-M2 J VF F05 VF F05 FD 1880-M2 1883-M2 VF AF-TR8 I FD 18-M2 m MAX 35 m max 35 m max 15 General Catalogue Safety 1-18

Maximum spans Max. rope length (m) 25 10 Maximum spans for switches with longitudinal head example A example B example C-E example D The max. recommended spans are indicated in the diagram as a function of the temperature fluctuations (temperature differences) to which the switch may be exposed at the point of use. For instance, with installation of type C and a temperature difference of C, the max. recommended rope length is 10 metres. 5 0 0 10 50 0 80 90 100 Temperature difference ( C) 80 Maximum spans for switches with transversal head Max. rope length (m) 0 50 example F example G example H-J example I 10 0 0 10 50 0 80 90 100 Adjustment of the switching point Temperature difference ( C) Important: The above data are guaranteed only using original rope and accessories. See page 185. Tighten the rope connected to the switch, until the end of the indicator (1) reaches about the middle of the green ring (2). Pull the knob (3) in order to close the safety contacts inside the switch. Below the knob a green ring (4) will be disclosed. General Catalogue Safety 1-18 16