AquaPure Ei TM Series Replacement Kits

Similar documents
Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Installation Instructions: Read these instructions in its entirety before performing any installation work.

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Jandy Pro Series NeverLube and Backwash Valve

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation and Operation Manual

Jandy Pro Series Water Feature Pump Model WFTR INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

poollux Power plx-pw60 & plx-pw100

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Jandy FloPro (FHP) Series Pump Parts Replacement Kit Instructions

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

Electric Vehicle Charging Station

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

LEV olor. Installation and Operation Manual. Levolor II by Jandy Electronic Water Leveler Model K-2000

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

WARNING FOR YOUR SAFETY:

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL

GFK-210-C Blower System - Installation and Operating Instructions -

Underwater Pool Color-Changing LED Light

WARNING. Important Notice

IntelliTouch Pool and Spa Control System Load Center and Power Center

Diagnostic Test Kit Series P Series WARNING. for Polaris Robotic Cleaners

SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems)

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

Model (Circuit Tester) Model (GFCI Tester)

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

POOL BARON Nicheless Color Changing LED Pool Light

- Wiring Brochure Zone Manager 335

INSTALLATION INSTRUCTIONS

PVM 220 Installation Guide

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

OnCommand Troubleshooting Guide Hayward Industries

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Model 8144NC Fresh Air Ventilator

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

Powerware Vdc Extended Battery Cabinet User s Guide.

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Zodiac VS FloPro Variable-Speed Pump Series E3 INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

BRILLIANT WONDERS 1.5" LED LIGHT

WF-5110R True Sine Wave Inverter

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

MIL-24/2600Q MIL-24/3200DQ

IntelliTouch Expansion Center Kit

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation and Operation Manual. FloPro Series Pumps WARNING. Model FHPM

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

SUBMERSIBLE POND PUMP

Owner's/Installation Manual

Control Parts. AquaLink Touch Replacement Parts 2011 ZODIAC POOL SYSTEMS CATALOG 141. Control Parts

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Installation and Maintenance Manual

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

User s Manual. Automatic Switch-Mode Battery Charger

Switching DC Power Supply

INTELLIBRITE 5G COLOR POOL AND SPA LIGHTS

OpenEVSE - 40A Charging Station

- Wiring Brochure Zone Manager 336

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

INTELLIBRITE 5G WHITE AND COLOR POOL AND SPA LIGHTS

"Engineered to Ride, Built to Last "

Installation Instructions: ACCENT SYSTEM

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Operation and Installation Manual

USER GUIDE. AeroVironment EV Solutions Charging Station Model EVSE-RS Plug-in

CAUTION: Read manual carefully for proper procedures and operation.

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

MODEL D-WBG Wishbone Arm Barrier Gate Operator

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Owners Manual: - Pumps

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

G76x Direct Spark Ignition Controls

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

User Manual. Solar Charge Controller 3KW

PVM 220 Installation Guide

PowerAir Compressor Installation

1000 Watt Pure Sine Wave Power Inverter, Users Manual

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Part Number: kW 800 Incoloy Element kW 800 Incoloy Element With 4kW Titanium Element kW 800 Titanium Element

"Engineered to Ride, Built to Last "

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Installation Instructions

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

IntelliChlor Electronic Chlorine Generator Commercial System COMSYS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

WF-5100 Series True Sine Wave Inverters

Transcription:

AquaPure Ei TM Series Replacement Kits for Models APURE35/35C WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. These instructions are to be used with the following Jandy Replacement Parts: R0512100 -- R-Kit, Power PCB Assembly R0512300 -- R-Kit, Control PCB Assembly R0512400 -- R-Kit, Controller Cover Assembly R0512500 -- R-Kit, Output Cable Assembly 1. Introduction This document gives instructions for replacing various components on the Jandy AquaPure Ei chlorine generating device. The instructions were written with safety as the priority and must be followed exactly. Not following the written procedure or taking shortcuts may increase the risk of personal injury. Read through the instructions completely before starting the procedure. 2. Ordering Information To order or purchase parts for the Jandy AquaPure Ei chlorine generating device, contact your nearest Jandy dealer or distributor. If they cannot supply you with what you need, call Zodiac Pool Systems, Inc. at 1.800.822.7933. In Canada call Zodiac Pool Systems Canada, Inc. Customer Support Department at 1.888.647.4004. Before starting the procedure, use the parts list at the back of these instructions to identify the parts that are in your kit. If any parts are missing from the kit please call your local Jandy distributor for assistance. For technical assistance, please contact our Technical Support Department at 1.800.822.7933. H0342700 Rev A

Flow On/Off Output Salt Page 2 Jandy Pro Series AquaPure Ei Series Replacement Kit Instructions 3. Installing Power Pack R-Kits 3. Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals. WARNING Disconnect power to the system at the main circuit breaker before performing this procedure to avoid risk of electric shock which can result in property damage, severe injury or death. Unplug the ribbon cable from the Power PCB (see Figure 3). Control PCB Assembly (R512300) Power Pack Cover Assembly (R0512400) Power PCB Unplug the Ribbon Cable Power PCB Assembly (R512100) Figure 1. Output Cable Assembly (R512500) Power Pack R-Kits A. Replacing the Power Pack Cover Assembly, and the Control PCB Assembly Disassemble to the component that needs replacement. Figure 3. Unplug Ribbon Cable 4. Remove the power pack cover from the back plate. Turn the cover over and remove the four (4) screws attaching the Control PCB to the cover. 5. Attach the new Control PCB to the cover using the four PCB mounting screws provided in the kit (see Figure 4). 1. Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker. 2. Detach the outer dress cover from the power pack by pressing on each of the sides and lifting up (see Figure 2). Outer Dress Cover Figure 4. Control PCB Installed Figure 2. Power Pack Installed To remove the outer dress cover, press on the sides and lift up. 6. Plug the ribbon cable into the Power PCB. 7. Reattach the cover to the back plate using the four (4) mounting screws. 8. Reattach the outer dress cover. 9. Reconnect the power.

Jandy Pro Series AquaPure Ei Series Replacement Kit Instructions Page 3 B. Replacing the Power PCB Assembly 1. Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker. 2. Detach the outer dress cover from the power pack by pressing on each of the sides and lifting up (see Figure 2). 3. Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals. Unplug the ribbon cable from the Power PCB (see Figure 3). 4. Remove the power pack cover from the back plate. 5. Disconnect all the wires from the Power PCB. 6. Keeping the wires threaded through the Power PCB Bracket, detach the bracket from the back plate by removing the two (2) screws and three (3) washers (see Figure 5). IMPORTANT Do not discard the Power PCB Bracket as it will be installed on the new Power PCB Assembly. Power PCB Assembly 8. Connect the wires to the Power PCB (see Section 4: Power Pack Wiring Instructions). 9. Plug the ribbon cable into the Power PCB. 10. Reattach the cover to the back plate using the four (4) mounting screws. 11. Reattach the outer dress cover. 12. Reconnect the power. C. Replacing the Output Cable Assembly 1. Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker. 2. Remove the terminal cap from the cell and disconnect the cell leads. 3. Detach the outer dress cover from the power pack by pressing on each of the sides and lifting up (see Figure 2). 4. Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals (see Figure 3). 5. Disconnect the Output Cable from the Power PCB (see Figure 6). Power PCB Bracket Wire to AquaLink RS System (Optional) Power Cord Output Cable (to Cell) Output Cable (to Cell) Figure 6. Output Cable Assembly Detached Figure 5. Removing the Power PCB Bracket 7. Attach the Power PCB Bracket to the new Power PCB Assembly. Attach the left side of the bracket (next to fan) using one (1) screw and two (2) washers. Attach the right side of the bracket using one (1) screw and one (1) washer. The extra washer on the left side will prevent the screw from hiting the fan guard on the other side. 6. Remove the grommet and the cable from the Power PCB Bracket. 7. Thread the new Output Cable assembly through the Power PCB Bracket and secure it in place using the grommet.

Page 4 Jandy Pro Series AquaPure Ei Series Replacement Kit Instructions 8. Connect the Output Cable wires to the Power PCB (see Figure 12). 9. Securely connect the cell leads to the like colored terminals (see Figure 7). Figure 7. Red Black Connecting Cell Leads 10. Reattach the terminal cap. 11. Reattach the cover to the back plate using the four (4) mounting screws. 12. Reattach the outer dress cover. 13. Reconnect the power. Red Blue 4. Power Pack Wiring Instructions WARNING When using electrical products, basic precautions should always be followed, including the following: DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before attempting installation or service, ensure that all power to the device is disconnected/ turned off at the circuit breaker. Connect only to a circuit protected by a ground-fault circuitinterrupter (GFCI). Grounding is required. The unit should be installed by a qualified service representative and should be properly grounded and bonded (See Section 4.B, Bonding). To avoid property damage, serious injury or death, never use the chassis backplate of the power pack to ground any other equipment. Install to permit access for servicing. Please read all cautions and safety instructions in the Important Safety Instructions section of the Jandy AquaPure Ei TM Series owner s manual (H0331400). Before attempting any electrical wiring, be sure to read and follow safety instructions. Wiring should only be attempted by a qualified professional. A. Wiring the Power Pack to the Power Source 1. Wire power pack to pool pump power source using 3.3 mm 2 (12 AWG) insulated wire and conduit. The power pack should be connected to the pump motor switch or automatic timer (pool pump timer) as shown in Figure 12. 2. Attach the third wire (ground) from the electrical panel to the ground point inside the power pack. Bonding per Section 4.B must also be accomplished to ensure personal safety and safety of equipment. B. Bonding 1. The National Electrical Code (NEC ) requires pool equipment to be bonded to each other. Check your local codes to determine if the NEC and/or other local installation codes are enforced by the Authority Having Jurisdiction (AHJ). A solid, copper 8.37 mm 2 (8 AWG) wire is recommended, per the NEC, for bonding the power pack to a permanent bonding connection that is acceptable to the local AHJ. Refer to your locally enforced codes for the acceptable bonding wire gauge. Attach the bonding point located on the bottom of the chassis backplate to a common bonding point. Do not use the power pack as the common bonding point. Each piece of non-related pool equipment requiring a ground should also be bonded to the common, approved bonding point. There should be one bonding connection to the power pack. In Canada, the Canadian Electrical Code (CEC) dictates that the bonding conductor be, minimum 13.3 mm 2 (6 AWG). C. Connection to an AquaLink RS Control System or PDA (Optional) The Jandy AquaLink RS or PDA is a multi-function pool controller which can fully control the function of the Jandy AquaPure Ei chlorine generating device. Adjustment of the chlorine production rate can be controlled from the main menu of the Jandy AquaLink RS or PDA. The AquaLink RS or PDA offers individual pool and spa settings for output percentage. Refer to the AquaLink RS or PDA Owner s Manual for more information. NOTE The Jandy AquaPure Ei chlorine generating device will communicate with all AquaLink models Rev. K or later.

Jandy Pro Series AquaPure Ei Series Replacement Kit Instructions Page 5 D. Verify the Controller Type on the Power Pack is Set Correctly Before wiring to an AquaLink RS Control System, the controller type must be set to JANDY L/M to allow communication between the power pack and the AquaLink RS Control System. The default controller type setting on the power pack is Jandy L/M. Follow the instructions below to verify the controller type is set correctly. NOTE The controller type must be set correctly before making the wiring connection between the power pack and the AquaLink, otherwise the power pack may be locked out of the AquaLink. To verify the controller type is set correctly: Power PCB Assembly Blue Wire Pin #2 (120V or Neutral) Line 2 Pin #4 (120V) Line 1 Brown Wire TRI/Ei TVSS PCBA Detail White Wire Black Wire 1. Apply power to the power pack. 2. Wait for the start-up sequence to complete. 3. Press and hold the OUTPUT button for approximately four (4) seconds. After four (4) seconds, a controller type will be displayed on the screen. 4. Verify that the JANDY L/M controller type appears on the display. If the contoller type is not set to JANDY L/M, keep the OUTPUT button pressed to toggle through the list of contollers. Each controller will be displayed on the screen for two (2) seconds. Release the OUTPUT button when JANDY L/M appears on the display. E. Wiring TRI/Ei TVSS PCBA to the Power PCB 1. Wire TRI/Ei TVSS PCB Assembly to Green 4-pin connector (see Figure 8). a. Into Green 4-pin connector, insert the Blue Wire into Pin #2 (120v Or Neutral). b. Into Green 4-pin connector, insert the Brown Wire into Pin 4 (120v). 2. Wire incoming Main Power to the TRI/Ei TVSS PCB Assembly (see Figure 8). a. Into Line 2, insert LINE 2 (for 240v incoming), or NEUTRAL (for 120v incoming. Figure 8. Power PCB with TRI/Ei TVSS PCBA F. Wiring to the AquaLink RS Control System or PDA 1. Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker. 2. Detach the outer dress cover from the power pack by pressing on each of the sides and lifting up (see Figure 2). 3. Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals (see Figure 3). NOTE: Be careful not to pull the ribbon cable that is connected to the Power Supply and the Cover. 4. Remove the white cap covering the comm hole (see Figure 9). 5. Thread the controller cable through the hole. A grommet may be necessary depending on the size of the cable being used. 6. Attach a cable tie to the controller cable as shown (see Figure 9). b. Into Line 1, insert LINE 1 (for 240v incoming), or HOT (for 120v incoming).

OPTIONAL Page 6 Jandy Pro Series AquaPure Ei Series Replacement Kit Instructions AquaLink RS or PDA Power Center 240 VAC Filter Pump Relay Aux. 3 Relay To Filter Pump (240 VAC) Line 1 Load 1 Line 2 Load 2 To Breaker Panel To Power Pack (240 VAC) Comm Hole Cable Tie 120 VAC Filter Pump Relay Aux. 3 Relay Figure 9. Accessing and Wiring to the Power PCB To Filter Pump (120 VAC) 7. In the AquaLink RS or PDA power center, wire the power pack directly to the LOAD SIDE of the filter pump relay (see Figure 10 and 12). 8. The AquaLink RS or PDA and power pack use a four (4) wire connection to communicate and can be wired up to 500 feet apart. Any outdoor rated four conductor cable, minimum 22 AWG, can be used. Locate the appropriate screw terminals on the circuit board and wire the power pack to the AquaLink RS or PDA red 4-pin terminal bar (see Figure 11). Figure 10. Line 1 Load1 Neutral To Breaker Panel To Power Pack (120 VAC) Wiring Power Pack to an AquaLink RS or PDA Power Center (240 VAC and 120 VAC) Power Pack NOTE The screw terminals on the AquaLink RS or PDA are removable to aid in installation. Red, 4-Pin Terminal Bar GRN YEL 4321 0V POS B A Jandy Power Center GRN YEL Figure 11. Communication Wiring between Power Pack and AquaLink RS Control System or PDA Network

G. Testing the Connection Jandy Pro Series AquaPure Ei Series Once the power pack has been wired to the AquaLink RS Control System or PDA, follow these steps to test the connection: 1. Apply power to the power pack and the AquaLink RS Control System or PDA. 2. Wait about 20 seconds. If the connection was successful, a Ŧ symbol will appear in the top right corner of the power pack display. Replacement Kit Instructions Page 7 NOTE If the power pack does not connect to the controller, turn the power off to both devices and repeat steps 1 and 2. If the power pack still does not connect to the controller, re-check the wiring connections (see Figure 10) and the controller setting on the power pack (see Section 4.D). 5. Parts List The following table is for your reference. To order additional parts, please contact your local Jandy Distributor. R0512100 R0512300 R0512400 R0512500 Description Power PCB Assembly 1 -- -- -- Controller PCB Assembly -- 1 -- -- Output Cable Assembly -- -- -- 1 Power Pack Covers -- -- 1 -- Control PCB Mounting Screws -- 1 -- -- Power Supply Cover Screws 1 -- -- --

Page 8 Jandy Pro Series AquaPure Ei Series Replacement Kit Instructions Use Copper Conductors Only Rated for 90 C Minimum Power PCB* Factory Wired for 240 VAC or 120 VAC ~ POOL PUMP TIMER CIRCUIT BREAKER PANEL 9 12 3 TO EI CELL 240 VAC or 120 VAC 50/60 Hz 3 wire LINE 1 LINE 2 GROUND 6 TO FAN BLUE NOT USED BLUE 0V NOT USED OPTIONAL CONNECTION TO AQUALINK RS OR PDA GRN YEL 0V POS B A RIBBON CABLE FROM CONTROL PCB Pool Pump GROUND (CHASSIS) NOT USED Line 2 120V TO EARTH BONDING POINT NOT USED Pump Line 4 NEUTRAL TO EARTH BONDING POINT TRI/Ei TVSS PCBA BRN BLUE LOAD 2 LOAD 1 WHT *The Power PCB auto-detects voltage Figure 12. 240 VAC or 120 VAC Wiring Diagram Zodiac Pool Systems Canada, Inc. 2115 South Service Road West, Unit 3 Oakville (ON) L6L 5W2 + 1 (888) 647-4004 www.zodiacpoolsystems.ca Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 www.jandy.com 2017 Zodiac Pool Systems, Inc. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks referenced herein are the property of their respective owners. ETL Listed Conforms To UL STD 1081 Certified to CAN/CSA C22.2 NO. 218.1 H0342700 Rev A