I. Pendant Mount Installation

Similar documents
MEDMASTER DOWNLIGHT Luminaires for MRI Applications

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

HBDBM High Bay Series

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Spun Bay Installation Standard Version (non dimmable), Hook Mount

High Bay Luminaire Series

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

MaxLite LED Linear HighBay Fixtures

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

MOONRING 1.5 MOONRING 3

When using electrical equipment, basic safety precautions should always be followed including the following:

ASSEMBLY AND INSTALLATION INSTRUCTIONS

HBDB High Bay Fixture with Occupancy Sensor

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

RSA-MRZ Installation Instructions

RSA-MRZ Installation Instructions

MODELS 2 & 4 Top Conduit Linears

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Installation Instructions CRAFT M/L

ZIP LIGHT LED LUMINAIRE

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION Bollard Light 12V

LAL SERIES LED LUMINAIRE

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

LED VAPOR PROOF FIXTURE

LED IMPORTANT SAFETY INSTRUCTIONS

General Installation Instructions LED

Installation Instructions

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

Specification Grade Contemporary Wall Mount/Technical Installation Data

poollux Power plx-pw60 & plx-pw100

MODELS. 2 & 4 Low Profile Linears

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

Circa Ambient Interior Luminaire

MAXLITE RKT LED Retrofit Kit

SAVE THESE INSTRUCTIONS

Operating Instructions

LED VaporProof Fixture

PROJECT INFORMATION. Catalog No.

LED IMPORTANT SAFETY INSTRUCTIONS

M Remote Mounting Kit

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

INSTALLATION INSTRUCTIONS

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

LHBC Commercial-Grade High or Low Bay Luminaire

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

WASP-P PRESSURE SENSOR

Installation Instructions Shaper 1800 aircraft cable installation

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting

Installation Instructions for Appleton Mercmaster LED Luminaire

INSTALLATION INSTRUCTION MANUAL

WARNING / AVERTISSEMENT

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

Verax 75 and Verax VPA Installation Manual

NT-300 Series Single Circuit Track System & Accessories

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

ALL W INSTALLATION INSTRUCTIONS

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design

PDMHB Watt LED I-Beam High Bay

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instruction ALG Series LED Area Light Version: 3.1

UB-2 2 Universal Button

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

FOURNISSEUR : CE MANUEL DOIT ÊTRE REMIS À L UTILISATEUR DE CE PRODUIT.

M Remote Mounting Kit

ALL200RM/ALL200RM-CM

IMPORTANT SAFETY INSTRUCTIONS

FOR PROPER AND SAFE INSTALLATION OF THIS PRODUCT, PLEASE READ THE FOLLOWING INSTRUCTIONS.

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Elle Surface Mounting Instructions

TSM 610A. Installation Manual. Ver 2.4, 2014

Options AMF Antimicrobial Finish (All Exposed Surfaces) BLK Black Doorframe. Accessory

Standard Grade 14 Inch Reflector. Ordering Information

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

Lighting Systems Argus-7

Installation Instructions: Eco Linear High Bay

ALL700RM-230V INSTALLATION INSTRUCTIONS

Highbay Fluorescent - Six Lamp Flat Profile Design

LED UFO High Bay with j-box Installation Instruction

Captivate Illuminated Mirror Light

Transcription:

LED HIGH BAY MAX Luminaires for High Bay Applications HBM SERIES IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: 1 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS. SAVE THESE INSTRUCTIONS I. Pendant Mount Installation Cover Nut 1. Remove cover by removing nut from fixture. Nut and washer Hub Cover 2. Slide the nut, washer and cover over the stem (stem supplied by others). 3. Fasten the hub to the stem.

2 Fixture Bracket Loop Bracket Adjustment Screw 4. Hook loop bracket to fixture hanger bracket. NOTE: Slide Adjustment Screw to level the fixture. Nut 5. Make electrical connection, then slide cover down. 6. Fasten nut tightly over hub for water-tight seal. III. Trunnion Kit Installation Trunnion Bracket 1. Remove the two (2) nuts holding the cover. 2. Remove the four (4) bolts holding trunnion bracket together.

3 Sealed hub (by others) 3. Fasten the top bracket to the surface, using two (2) 5/16" bolts (supplied by others). 4. Attach 3/4" sealed hub (supplied by others) and conduit. 5. Make electrical connections. 6. Fasten cover down. 7. Reattach the four (4) bolts to the trunnion bracket.

LOOP HANGER INSTALLATION HL (ATTACHED AT FACTORY) 1. Wire cord leads to power supply leads using connectors suitable for the gauge and number of wires being used. Black fixture lead connects to the supply conductor, white fixture lead connects to the neutral supply conductor, and the grounding wire must be connected to a suitable ground. 2. Hang luminaire by attaching to user supplied chain or cables. 3. Connect power cord. 4. As a safety recommendation, an additional aircraft cable (not included) should be used to attach the loop hanger and supporting structure. LOOP HANGER CORD WITH QUICK-DISCONNECT 4 SAFETY RECOMMENDATION Aircraft cable (not included) is recommended for attaching the fixture structural to the upper structural. II. Safety Cable Option 1. Remove screws and lift cover of fixture. Loop safety cable under center support. 2. Send straight end through loop end of the safety cable. 3. Replace cover and secure the cable to the super-structure.

LED HIGH BAY MAX Luminaires for High Bay Applications Optic HBM SERIES Alignment Key Fixture align arrow aimed in this position will yield these patterns. (See fixture label for type ordered) BIRD GUARD INSTALLATION 1. Bird Guard lays on top of casting. Detail A Scale 2:1 PENDANT MOUNT & TRUNNION KIT Type 2 Type 3 Type 5 Square L'INSTALLATION PAR UNE PERSONNE QUI Aisleconnaît BIEN LA CONSTRUCTION ET DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION B OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS A MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS. Fixture Align Arrow Label Detail Top View IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE Type 4 INSTALLATION CODE BY A PERSON Type 5 FAMILIAR WITH THE CONSTRUCTION AND Narrow OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. CE PRODUIT DOIT ÊTRE INSTALLÉ EN CONFORMITÉ AVEC LE CODE DE LE FONCTIONNEMENT DU PRODUIT ET LES RISQUES ENCOURUS. SAVE THESE INSTRUCTIONS 51 (For Trunnion Kit use slots) Pendant Mount 2. Attach both sides with (4) screws provided. Trunnion Kit F-5406_073014

6 CUSTOMER SERVICE For technical assistance, call 1-800-4KENALL (1-800-453-6255). WARRANTY For warranty information visit www.kenall.com/resources/certified-performance-warranties