V5422L / V5422E ACTUATED BUTTERFLY VALVES. FEATURES With factory-mounted electric actuator. SPECIFICATIONS Valves

Similar documents
V5422L / V5422E ACTUATED BUTTERFLY VALVES. FEATURES With factory-mounted electric actuator

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

V5422L / V5422E ACTUATED BUTTERFLY VALVES. SPECIFICATIONS Valves

Motorized Butterfly Valve

Motorized Butterfly Valve Actuated Wafer type butterfly valves

Motorized Butterfly Valve

V4(V7)-ABFW-EPN16 Actuated Wafer type butterfly valves

Motorized Butterfly Valve

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

S1024-2POS / S POS S2024-2POS / S POS

ML7420A/ML7425A,B. Honeywell. Electric Linear Valve Actuator FEATURES SPECIFICATIONS GENERAL SPECIFICATION DATA

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Concentric butterfly valves

Installation Operation Maintenance

BUTTERFLY VALVE 17 SERIES Gearbox

BUTTERFLY VALVE VF-7 Series

BUTTERFLY VALVE 1234P SERIES

Control shut-off butterfly valves DN 25 DN 200 PN

BUTTERFLY VALVES + NA ELECTRIC ACTUATOR

Butterfly valves for high temperature series GD(H) - LDK

VALVE WITH SA ELECTRIC ACTUATOR

Series A Electric Linear Actuators

VALVES WITH NA ELECTRIC ACTUATOR

BALL VALVE - 10 SERIES Electric actuator - El-O-Matic

ML6420A/ML6425A,B. Electric Linear Valve Actuators

BUTTERFLY VALVE - WAFER FAF 3500

VALVES WITH SA ELECTRIC ACTUATOR

BUTTERFLY VALVE - N1234 SERIES Pneumatic actuator - Actreg

Diaphragm Valve, Metal

Greater Cairo Foundries. Concentric Rubber Lined Butterfly Valves

BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic

CV-SFS4-PN16 SERIES SLIENT CHECK VALVE, GLOBE TYPE FEATURES SPECIFICATIONS PRODUCT IDENTIFICATION SYSTEM PRODUCT DATA

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

Pneumatic Butterfly Valve Type 3335 / AT

AWWA C 504 Type - Butterfly Valves AWWA C 504 BUTTERFLY VALVES

R o L. BUTTERFLY VALVE of carbon steel with flanges series BLUE LINE. Operation. Edition

ALC-3 BUTTERFLY VALVES NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS DESIGN. ANSI Class PN DN

Control Valve, Metal. Options Versions according to ATEX for manual and pneumatic operation on request

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe

STEVI 440 / 441. Straight through control valve DN

Diaphragm Valve, Plastic

R o L. BUTTERFLY VALVE of carbon steel with welded ends 313 -series BLUE LINE. Description

Butterfly valve, Metal

TRF.. series spring return rotary actuators for CCV

Quarter turn actuators Index

Butterfly valves ARI-ZIVA -Z / ARI-ZIVA -G. with notch lever. with worm gear. with electric rotary actuator rotork

BALL VALVE SERIES Electric actuator - El-O-matic

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

Page 6. Page 6. Page 6. Page 7. Page 8. Page 9. Page 10 / 11

VG9000 Flanged Valves

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Electric actuators type EA25-250

Butterfly valves Plastic and Metal

ARI-ZESA / ARI-GESA / THEA Butterfly valves

VF6000/VA300/VA200 Series VF6000 Series Butterfly Valve and VA300/VA200 Actuator

ISO-DE Double Eccentric Butterfly Valves

BR 11e Centric Control and Shut-off Butterfly Valve

Wafer Check Valve Type 012 PVC-U

Butterfly valve Series K

The ParaSeal range features a proven disc shaft and seat arrangement, to be used in high pressure and high velocity applications.

Type / Material code Body* Disc Stem Lining**

Butterfly valves. ARI-ZIVA -Z - Fig Free of maintenance wafer pattern butterfly valve - soft sealed - industrial range

OPTIMAL VALVE SOLUTIONS PRODUCT PROGRAM

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Type 145. Electrically Actuated Wafer Butterfly Valve

Control shut-off butterfly valves DN 25 DN 200 PN

Butterfly Valve. Product Training Presentation Danfoss Flomatic Corporation

710, 717, 723. Ball Valve, Plastic

INSTRUCTION MANUAL ACTUATOR CLASSE II TYPE MAS4

Motor Valve GS 1 series, DN 15 up to DN 150

with electric and pneumatic actuators Control valve in 3-way-form (3-way mixing valve) DN 300 ARI-STEVI 423 Electric actuator ARI-PREMIO

STEVI 450 / way control valve in mixing and diverting design DN

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Installation, Operation and Maintenance Manual for the HE Series

Pneumatic Shut-off Butterfly Valve Type 3335/BR 31a

Rate B standard. Rate A Rate A option. max +260 C/ min -40 C

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

Mounting and Operating Instructions EB 5868/5869 EN

BUTTERFLY VALVES KENNEDY 140 YEARS AWWA C504 CLASS 150B & 250B CERTIFICATIONS ISO 9001 ISO BS OHSAS

Dura Water Wafer Butterfly Valve

BALL VALVE SERIES Electric actuator - El-O-matic

15100 VALVES. E. Section Building Automation and Control System Guidelines

Wafer and lug types, with or without gearbox

The BL10000 Tight sealing 2-way lug butterfly valve

SAFETY SHUT-OFF VALVE HON

BR 10a Control and Shut-off Butterfly valve

FE DN PVC-U. Butterfly valve

BUTTERFLY VALVES + SA ACTUATOR

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Tilting-disc Check Valves Short Body

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

ERHARD is a company of. Datasheet ERHARD ERK tilting-disc check valve

Type 147. Electrically Actuated Lug Butterfly Valve

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Transcription:

V5422L / V5422E ACTUATED BUTTERFLY VALVES FEATURES With factory-mounted electric actuator SPECIFICATION DATA Centric butterfly valve with elastomer liner Wide DN range (DN250 through DN600) For heating water containing up to 50 glycol Wafer body For modulating and floating control maintenance-free control drive mechanical setting indicator includes manual operation ample reserve torque sizable terminal compartment for cabling long unit lifetime GENERAL The V5422L and V5422E Actuated Butterfly Valves are suitable for heating and cooling applications as well as in boiler management systems. They can also be employed for general services, water treatment, etc. The V5422L series is equipped with floating-control actuators (230 V, three-point). The V5422E series is equipped with modulating-control actuators with a standard control signal of 0...10 V (2...10 V, 0...20 ma, and 4...20 ma also possible). The actuators and valves are provided factory-mounted. The position control and the end stops are completely justified. SPECIFICATIONS Valves Sizes Nominal pressure rating Shut-off pressure Tightness Temperature of medium Body DN250...DN600 PN10 10 bar bubble-tight -10...+110 C Wafer, ductile iron GG25 Rilsan/epoxy-coated EPDM EW (max. 130 C) GGG40, epoxy-coated Liner Disc Shaft Stainless steel 1.4028 (AISI 420) Actuators Motor voltage 230 Vac ( 10%), 50 to 60 Hz Current, running time See Table 1 Angle of rotation 90 Duty cycles max. 30% (class S4 IEC60034) Running noise 65 dba Ambient temperature -20...+70 C Motor insulation class F according to VDE 0530 Protection class IP67 as per DIN 40050 Cable gland PG16, cable 9...16 mm Copyright 2004 Honeywell Inc. All rights reserved

floating version Table 1. Type list for different valve sizes and corresponding data modulating actuator current (A) run time actuator valve size version nominal start (sec) torque (Nm) (DN) Kvs (m 3 /h) V5422L1006 V5422E1001 1.2 1.7 30 600 250 4800 39.2 V5422L1014 V5422E1019 1.2 1.7 30 600 300 7000 48 V5422L1022 V5422E1027 2.0 3.0 30 800 350 8300 60 V5422L1030 V5422E1035 1.2 1.7 60 1200 400 11000 87 V5422L1048 V5422E1043 2.5 3.5 60 1500 450 14000 127 V5422L1055 V5422E1050 2.5 3.5 105 2500 500 000 193 V5422L1063 V5422E1068 2.5 3.5 120 4000 600 25000 250 weight (kg) GENERAL CHARACTERISTICS Position Indication and Running Status The actuator's position is indicated by a mechanical pointer located behind a window on the actuator's cover. The actuator's running status is indicated by three LED's located on the printed circuit board: The green LED (Op) is lit when the valve has been opened. The red LED (Cl) is lit when the valve has been closed. Angle Limitation The angle at the drive shaft can be adjusted to between 0 and 90. Emergency Manual Operation The end position is limited both electrically and mechanically. The electrical limitation can be adjusted by pressing and turning (with a screwdriver) the adjustment screws situated on the white and black cams. The end position is factory-set to -2 and +92. As a rule, it is not necessary to alter this value. CAUTION Before manually adjusting the valve, you must first disconnect the power supply. It is possible to adjust the valve using the full-disk manual safety wheel. Actuators with a valve size of DN500 and DN600 are equipped with a manual safety wheel which is declutched automatically when the motor is running. Prior to using the manual safety wheel, it must be re-engaged using the declutch button. In the case of actuators with a valve size of DN250 and DN300, the motor can be disengaged using the motor declutch lever. Motor and Gear Protection The actuator motor is protected against overheating by a bimetal temperature monitor. The motor and gear train are also protected against mechanical overload by a torque limiter switch. The yellow LED (Tq) is lit when the torque limiter has been activated. Maintenance The actuators are maintenance-free. They are lubricated for a minimum of 100,000 operations. If it becomes necessary to renew the grease completely, use a lubricant complying with the following specifications: temperature range: -30...+135 C penetration: ASTM 265/295 at 25 C drop point: 0 C E.g. ELF Expecta 250, TOTAL Multis EP2, SHELL alvania EP2, MOBIL Mobilux EP2, or ESSO Beacon EP2. 2

Flow Rate and Pressure Drop Floating Control (V5422L) The V5422L series is equipped with a printed circuit board (see Fig. 2). This board is situated under the cover, where the angle indicator is likewise located. To access the printed circuit board, remove the cover. 1 2 16 4 9 feedback jacks Dead P1Band Tr1 Tr2 microswitches A B 7 6 5 4 3 2 1 15 12 14 11 10 Tr1 R2 R1 27 26 41 40 1 2 3 3 Cl Op Tq 70 71 72 73 31 32 51 53 L N PE Ful red/green/yellow LED input output power supply Fig. 2. Printed circuit board of the V5422L Microswitch Positions For floating control, the microswitches located on the printed circuit board (see Fig. 2) must be positioned as shown in Fig. 3. Fig. 1. Flow rate and valve pressure drop Fig. 3. Microswitch settings for V5422L Input Terminals An external floating controller controls the actuator of the V5422L. This controller transmits the phase to input 31 (for closing the valve) or to input 32 (for opening the valve). See also Fig. 8. Output Terminals In the "closed" end position, output 51 transmits the phase to an external indicator. In the "opened" end position, output 52 transmits the phase to an external indicator. 3

Modulating Control (V5422E) The V5422E series is equipped with a printed circuit board (see Fig. 4). This board (together with a feedback potentiometer) is situated under the cover, where the angle indicator is likewise located. To access the printed circuit board, remove the cover. P1 P2 offset adjustment 1 2 16 4 9 feedback jacks Dead Band Cl Op Tq A B Tr1 microswitches 7 6 5 4 3 2 1 red/green/yellow analog LED input/output Tr2 15 12 14 11 10 Tr1 R2 R1 27 26 41 40 1 2 3 3 70 71 72 73 31 32 51 53 L N PE end position output power supply Fig. 4. Printed circuit board of the V5422E Ful Terminals for Input/Output Signals An external modulating controller controls the actuator of the V5422E by means of an analog signal provided at terminal 70/71. An analog output signal for position indication is provided at terminal 71/72. Adjusting the Input/Output Signal Offset The offset of modulating actuators is adjusted at the factory and should not be changed. If you wish to change the offset (using offset potentiometer P2; see Fig. 4), note that a excessively small offset will result in oscillation of the actuator. Reversing Rotation Direction In the case of the V5422E, it is possible to reverse the direction of rotation of the valve by adjusting the feedback signals. The feedback signals are adjusted by resetting the microswitches and replugging the feedback potentiometer's cables. To do this, proceed as follows: 1. Turn the power off. 2. Reset the microswitches as shown in Table 2, but with microswitch 7 in position B. 3. Replug the feedback potentiometer's cables as shown in Fig. 6. Microswitch Positions Fig. 5 shows the settings of the microswitches located on the printed circuit board (see Fig. 4) at delivery-time. Fig. 6. Replugging the feedback potentiometer's cables Fig. 5. Microswitch settings for the V5422E at delivery Microswitches 1, 2, 3, and 4 are used to set the input signal range (0/2...10 V or 0/4...20 ma) and the corresponding output signal (see Table 2). Table 2. Resetting microswitches input/output signal microswitch positions 7 6 5 4 3 2 1 0...10 V A A A B B B B 2...10 V A A A A B B B 4...20 ma A A A A A A A 0...20 ma A A A B A A A 4. Apply the desired control signal (10 V or 20 ma, as the case may be) for the closing position. 5. Turn the power back on. 6. Using a small screwdriver, adjust the potentiometer P1 (located on the printed circuit board; see Fig. 4) until the valve closes completely. Valve Mounting Install the actuated valve in the pipe according the following steps (see also Fig. 7). 1. Spread the valve's flanges to facilitate installation. The valve's disc must be partially open. 2. Set all stay-bolts while keeping the valve's disc slightly open and without tightening the nuts. 3. Open the valve's disc completely. Ensure that the piping is aligned. Tighten diagonally opposite the nuts until the flanges are in contact with the body of the valve. Never use gaskets or grease. Never weld the flanges after the valve has been installed. 4

WIRING DIAGRAMS Floating Control (V5422L) Fig. 7. Remounting the valve Bolting The following table lists the number (n) of bolts and nuts required for mounting. The number (n) is dependent upon the size (DN). Fig. 8. Wiring diagram, V5422L Modulating Control (V5422E) Table 3. Bolts and nuts required for installation DN PN10 bolts (M x length) n 250 M20x150 12 300 M20x160 12 350 M20x160 16 400 M24x190 16 450 M24x240 16 500 M24x260 16 600 M27x300 16 Fig. 9. Wiring diagram, V5422E 5

ACTUATED VALVE DIMENSIONS Fig. 10. Actuated butterfly valve (side view) valve Table 5. Valve dimensions and weight valve dimensions (mm) weight size (DN) A B C D H (kg) 250 280 196 68 324 243.5 22.2 300 315 232 78 378 292.5 30.8 350 330 257 78 425 329.5 41.5 400 365 292 102 475 375.5 57.2 450 400 359 114 ^538 426 95.0 500 440 397 127 595 577 125 600 525 467 154 695 572 0 Fig. 11. Actuated butterfly valve (top view) Fig. 12. Actuated butterfly valve (cross-sectional view) valve Table 4. Actuator dimensions and weight actuator dimensions (mm) weight size (DN) A B C D E (kg) 250 509 169 315 89 7 300 509 169 315 89 7 350 509 169 315 89 7 400 564 2 4 133 167 30 450 564 2 4 133 167 30 500 754 566 442 109 281 68 600 645 497 442 154 28 70 Automation and Control Solutions Honeywell GmbH Böblinger Straϒe D-71101 Schönaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://europe.hbc.honeywell.com Subject to change without notice. Printed in Germany Manufacturing location certified to